  • Hello! I am an AI chatbot trained to assist you with the Eurotech Catalyst TC Owner's manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Catalyst TC Development Kit Quick Start
for WRL LiveUSB
110125-9002A September-2011
What’s in the Box?
The development kit includes the following components:
Catalyst TC Development Kit carrier board
with industrial temperature Catalyst TC (CTTC5400)
or commercial temperature Catalyst TC (CTTC5401)
Catalyst Module Display Adapter
10.4-inch SVGA TFT LCD
with touch screen and backlight inverter
Black DB9FF cable (for maintenance port P2 only)
Null modem cable (6 foot, DB9FF)
12 VDC adapter and AC cord
Wind River Linux LiveUSB Run-Time preinstalled on
the Catalyst TC eMMC embedded flash drive
Utiliboot USB flash drive (4 GB) and FreeDOS USB
flash drive (2 GB) for booting the development Kit
Wind River Linux LiveUSB flash drive (16 GB)
for booting a development PC
Three Target Run-Time Options
Your kit can be configured to boot any of the following
three Linux distributions:
Wind River Linux LiveUSB Image (as shipped)
Eurotech Product Run-time
(WRL BSP + product layers)
Eurotech Product Run-time with Everyware Software
Framework (WRL BSP + product layers + ESF)
Running the LiveUSB Evaluation
As initially shipped, your Catalyst TC Development Kit
boots the LiveUSB run-time evaluation, which is quick to
set up.
To begin, connect both the Catalyst TC Development Kit
and the development PC to an Ethernet network that is
connected to the Internet. Standard kits are preinstalled
with the run-time images. If your system uses an external
Wind River Linux LiveUSB Run-Time drive, install it prior to
boot. Boot the Catalyst TC and the PC with the LiveUSB
flash drive.
For full details, see the Wind River Linux and Eurotech
Catalyst TC LiveUSB Evaluation Getting Started Guide.
The Wind River Linux LiveUSB flash drive includes:
Instructions to set up your Wind River evaluation on
the Catalyst TC Development Kit
Details about how to activate your free, 30-day license
for the Wind River Workbench development suite
Audio-visual guides that lead you through the Wind
River Linux evaluation
All the source code for Wind River Linux and the
Eurotech Product layers
Hardware documentation in the “Eurotech Catalyst TC
Documents” folder on the desktop
Reset Switch (SW1)
Power LEDs
On/Off Button (SW2)
DC Power Input (J29)
PCIe (J12, J14, J15)
SDVO Socket (J10)
Display Adapter in J11
CTTC5400
CTTC5401
Status Display (D36)
PS/2 Keyboard, Mouse (J34)
Serial 0 and 3 (P1)
SD/MMC (J51)
Ethernet (J63)
USB 0 to 3 (J3, J4)
110125-9002A September-2011
Using the Eurotech Product Run-Times
The Eurotech Product Run-Times are customized Wind
River Linux images that have been configured to include
additional features not present in the Catalyst TC BSP:
Ethernet is automatically configured using DHCP.
sshd is started automatically.
X Windows is included. Use “startx” to start it.
Device drivers and network features have been
enabled to support Wi-Fi, Bluetooth and wireless
modem devices, NAT, NTP, etc.
The root account password is “IsiTech”.
This run-time image is ready for deployment as a product
platform and is the base run-time used by Eurotech’s ESF.
Installation
1. Insert the bootable Utiliboot USB flash drive, attach a
keyboard, and power on the system.
2. Log in on the console using the root account with the
password “IsiTech”.
3. To install to on-board media, continue with the next
step. Otherwise, insert your removable media now
and allow the system to detect the drive. You may use
your own media, however Eurotech only provides
support for media we supply.
4. Install the Eurotech Product Run-Time by following the
instructions in the README.txt file. The install
process normally takes four to ten minutes. There are
a number of options not used in the README.txt file.
To display all the options, run “make-media.sh –h”.
5. Use the “poweroff” command to safely shut down.
Updating Your Development System
To install the Eurotech Product Run-Time, use the
Utiliboot USB flash drive as described previously.
To re-install the Wind River Linux LiveUSB run-time
evaluation, follow the instructions in Appendix A of the
getting started guide.
To update the BIOS, contact Eurotech Support for
BIOS update files and utilities. You will install these
files on the bootable FreeDOS USB flash drive.
Hardware Features
For details about the hardware features, see the
Catalyst TC Development Kit User Manual, #110125-9000.
Module Compatibility
The Catalyst TC does not support all connectors on the
carrier board. For details, see the Catalyst TC
Development Kit User Manual.
Note that the Catalyst TC will not boot in designs for the
Catalyst Module, Catalyst XL, or Catalyst LP. The
Catalyst TC Compatibility Technical Bulletin,
#110125-5002 describes these compatibility options.
Troubleshooting
If you are directed to use Maintenance port P2 while
working with Eurotech staff, use the black DB9FF cable
supplied in this kit. P2 is not for application use and does
not follow the EIA-232C standard.
See the support forums for additional tips.
Everyware
Software Framework
Information about Eurotech’s ESF is available at
http://esf.eurotech.com/
Eurotech Technical Support
For hardware support and issues relating to the Eurotech
Product Run-Time, use the Eurotech support site. The site
includes errata reports, user documents, and developer’s
forums. It is available to registered developers at:
http://support.eurotech-inc.com/
Next Steps
For additional information about the Catalyst TC, download
the Catalyst TC documents from the Eurotech support site
or contact your local sales representative.
Wind River Technical Support
For Wind River Workbench licensing issues, see
Appendix B of the getting started guide. For Wind River
Linux and LiveUSB support, contact
http://www.windriver.com/support/
Contact Us
EUROTECH
Toll-free +1 888.941.2224
Tel. +1 301.490.4007
Fax +1 301.490.4582
E-mail: sales.us@eurotech.com
E-mail: support.us@eurotech.com
Web: www.eurotech-inc.com
/