POWERTEX PC316 Operating instructions

  • I have reviewed the fitting instructions for the POWERTEX Wire Rope U-bolt Clip PC316. This document explains how to properly mount the clips, including the placement of the first clip and the U-bolt, as well as the minimum distance between clips. I am ready to answer any questions you may have about this product.
  • Where should the first clip be mounted?
    Where should the U-bolt be positioned?
    What is the minimum distance between other clips?
Fitting instruction for use Wire Rope U-bolt Clip PC316
First clip to be mounted as close to the pointed thimble as possible.
The U-bolt to be positioned on the rope’s free end.
The other clips are to be mounted with a minimum distance equal to
the width of the clip (c).
Size of clip (mm) Min. number of clips needed acc. to DIN 741
Up to 7 3
Over 7 up to 16 5
Over 16 up to 20 6
Over 20 up to 25 7
c
/