Package content:
There are additional accessories inserted with mounting material inside the ashtray. Remove it for completing the
installation. Amount and types of additional parts can vary depending on the type of the boiler.
ï‚· 3pcs of cleaning tools (brush, brush handle,
scraper) – for cleaning the internal parts of
the boiler.
 Filling valve – for filling water inside the boiler
and drainig if necessary.
 2pcs of burner screws – installed on the
burner outlet to hold the burner at right
position.
 Ash container – in the bottom part of the
boiler. There could be one or two section
ashtray.
 Burner flange – installed on the boiler opening
for the burner attachement.
ï‚· Burner flange gasket - installed between the
burner opening on the boiler and burner
flange.
ï‚· 4 screws of the burner flange - for mounting
flange on the boiler opening for the burner
attachement.
ï‚· 2 pieces of wing nuts for burner attachement -
to ensure the tightness between the flange
and the burner. Mounted on the burner
screws.
 2 washers – placed on the burner screws,
under the wing nuts.
4.3. Biopel 100 - 200kW
These boilers include a two-tier heat exchanger located in the upper part of the boiler. Exchanger pipes are located in a
horizontal position above the opening for the burner installation. Exchanger tubes have 2 diameter sizes for better air flow
in the boiler. In each of the tubes are turbulators, which are designed to reduce the temperature in the flue path so that the
resulting boiler efficiency is maximized. Turbulators are removable for easier access to the heat exchanger during cleaning.
For cleaning of heat exchanger tubes use the handle and plug brush, with which you can clean each of the exchanger tubes.
Be sure to place the turbulators back into each of the tubes after cleaning. The purity of the heat exchanger is critical to
ensure maximal heat transfer from the heated air into the water in the boiler and heating system.
Biopel 100 to 200 kW is equipped with two horizontal multilevel tube heat exchanger.
Biopel 100-200 kW is equipped with two main doors, front and rear. Pellet burner is attached in to the opening which is on
the front doors. Burner flange is attached to this opening as well. The burner is fitted into the hole with two burner screws
and two wing nuts. Proper tightness is important for preventing leackage of air in the boiler or to prevent leackage of fumes
from the boiler out. The door can be opened together with the burner for inspecting the inner parts of the boiler and burner
grate without having to remove the burner of the boiler. To open the door with the burner you must dismantle the PVC
hose between the burner and the feeder so that the external feeder doesn’t stay in the way of door opening.
Caution: Never open the front door with a burner when the flame is in the boiler. For the
flame inspection use always rear door.
Front and rear doors are attached to the boiler using solid hinges and on the other side by closing handles. The tightness of
the closure can be adjusted. Ensure tight closing of both doors and the correct adjustment of closing handles to prevent
accidental opening of the door or leakage of smoke into the room through leaky doors closing. The front and rear doors are
filled with flowing heating system water. Water is pumped through the door through the cooling hoses. Each hose is fitted
with a ball valve. Doors can be separated from system water in the body of the boiler, if need of doors removal, repair etc.
In the upper part of the boiler are water inlet and outlet for connection of the boiler into the heating system. Smaller is inlet
water to the boiler, bigger is outlet water from the boiler. Furthermore, the upper section provides outlet for flue gases.
You can find an opening for connecting the Lambda sensor (optional) on the flue gas outlet.
Boiler handling is provided in two ways, either by increased base in the bottom of the boiler,
or using a hoks in the upper part of the boiler.
Inlet for filling valve is located on the side of the boiler, bottom part. When filling the boiler, chack that all connections are
sealed properly so water cannot leak out of the connections anywhere on the boiler. Especially check cooling hoses
connections and do not forget to open all ball valves on each cooling hose so water can flow inside and outside the frontal
and rear doors.
Electrical parts are installed in the front of the boiler (control unit v9 and connection board). There are also two outlets for
temperature sensor installation (CH and Termik sensor) on the side of the boiler. All cables must be positioned so nothing
can damage cables during operation of the boiler or when opening front or rear doors. It is also important that cables
doesn’t touch metal surface of boiler body (surface under the boiler covers) and that cables do not lay down on the ground
without fixing. Hot ash can permanently damage electrical cabeling. Make sure that cables are fixed on the position and
cannot fall or move into the boiler when doors are opened. Bottom of the boiler is shaped so you can clean inside of the
boiler easily. Use cleaning tools to remove all ash out of the bottom surface of the boiler. Clean all parts of the boiler