SPAGNA VETRO - 200 Series
IMPORTANT:
Read and save these instructions.
NOTICE:
Installer: Leave this guide with the homeowner
Homeowner: Keep this guide for future reference
www.SpagnaVetro.ca
Important Safety Notice
Read all Instructions before Installing and operating this appliance
• Theinstallationinthismanualisintendedforqualiedinstallers,servicetechniciansorpersonswith
similarqualiedbackground.Installationandelectricalwiringmustbedonebyqualiedprofession-
alsandinaccordancewithallapplicablecodesandstandards,includingre-ratedconstruction.
• DO NOTattempttoinstallthisapplianceyourself.Injurycouldresultfrominstallingtheunitdueto
lackofappropriateelectricalandtechnicalbackground.
• Rangehoodmayhaveverysharpedges;pleasewearprotectiveglovesifitisnecessarytoremoveany
partsforinstalling,cleaningorservicing.
• ActivatinganyswitchONbeforecompletinginstallationmaycauseignitionoranexplosion.
• Duetothesizeandweightofthisrangehood,twopeopleinstallationisrecommended.
To reduce the risk of re, electric shock, or injury to persons:
• Forgeneralventilatinguseonly.DO NOTusetoexhausthazardousorexplosivematerialsandva-
pors.
• Thecombustionairowneededforsafeoperationoffuel-burningequipmentmaybeaffectedbythis
unit’soperation.Followtheheatingequipmentmanufacturersguidelineandsafetystandardssuch
asthosepublishedbytheNationalFireProtectionAssociation(NFPA),andtheAmericanSocietyof
Heating,RefrigerationandAirConditioningEngineers(ASHRAE),andthelocalcodeauthorities.
• Beforeservicingorcleaningunit,switchpowerOFFatservicepanelandlockservicepaneltopre-
ventpowerfrombeingswitchedONaccidentally.
• Cleangreaseladensurfacesfrequently.Toreducetheriskofreandtodisperseairproperly,make
sure to vent air outside. DO NOTventexhaustintospacesbetweenwalls,crawlspaces,ceiling,attics
or garages.
• DuctedfansMUSTalwaysbeventedtotheoutdoors.
• UseonlymetalductworkandthisunitMUSTbegrounded.
• Sufcientairisneededforpropercombustionandexhaustingofgasesthroughtheducttoprevent
backdrafting.
• Whencuttingordrillingintowallorceiling,becarefulnottodamageelectricalwiringorotherhid-
den utilities.
• Allelectricalwiringmustbeproperlyinstalled,insulatedandgrounded.
• Oldductworkshouldbecleanedorreplacedifnecessarytoavoidthepossibilityofagreasere.
• Checkalljointsonductworktoinsureproperconnectionandalljointsshouldbeproperlytaped.
• Usethisunitonlyinthemannerintendedbythemanufacturer.Ifyouhavequestions,contactthe
vendor.
To reduce the risk of a stove top grease re:
• Keepallfan,bafe,spaces,lter,greasetunnel,oilcontainerandgrease-ladensurfacesclean.Grease
shouldnotbeallowedtoaccumulateonfan,bafe,spaces,lter,greasetunnelandoilcontainer.
• AlwaysturnrangehoodONwhencookingathighheatorwhencookingamingfoods.
• Usehighsettingsoncookingrangeonlywhennecessary.
• Neverleavesurfaceunitsunattendedathighsettings.Boiloverscausesmokingandgreasyspillovers
thatmayignite.Heatoilsslowlyonlowormediumsettings. Page1
Page2
Important Safety Notice
Read all Instructions before Installing and operating this appliance
The manufacturer and/or distributor/reseller declines all responsibility in the event of failure to ob-
serve the instructions given here for installation, maintenance and suitable use of the product.
The manufacturer and/or distributor/reseller further declines all responsibility for injury due to neg-
ligence and the warranty of the unit automatically expires due to improper maintenance.
The manufacturer and/or distributor/reseller will not be held responsible for any damages to per-
sonal property or real estate or any bodily injuries whether caused directly or indirectly by the range
hood.
• Cleanventilatingfanfrequently.
• Alwaysuseappropriatecookwareandutensilssize.
• Alwaysusecookwareappropriateforthesizeofthesurfaceelement.
To reduce the risk of injury to persons in the event of a stove top grease re:
• SMOTHERFLAMESwithaclose-ttinglid,cookiesheet,ormetaltray,thenturnOFFtheburner.
BECAREFULTOPREVENTBURNS.NEVERPICKUPAFLAMINGPAN—youmaybeburned.
KEEPFLAMMABLEORCOMBUSTIBLEMATERIALAWAYFROMFLAMES.IftheamesDO
NOTgooutimmediately,EVACUATEANDCALLTHEFIREDEPARTMENTordialyourlocal
emergencyserviceimmediately.
• DONOTUSEWATER,includingwetdishclothsortowels—aviolentsteamexplosionwillresult.
• UseanextinguisherONLYif:
• YouknowyouhaveaClassA,B,Cextinguisher,andyoualreadyknowhowtooperateit.
• Thereissmallandcontainedintheareawhereitisstarted.
• Theredepartmentisbeingcalled.
• Youcanghttherewithyourbacktoanexit.
To reduce the risk of injury to persons in the event of a gas leaks:
• Extinguishanyopename.
• DONOTturnontherangehoodfanoranytypeofventilator.
• DONOTturnonthelightsoranytypeofappliance.
• Openalldoorsandwindowstodispersethegas.Ifyoustillsmellgas,callthegascompanyandre
department,ordialyourlocalemergencyserviceimmediately.
WARNING
Yoursafetyandthesafetyofothersisveryimportant.Wehaveprovidedmanyimportantsafetymes-
sagesinthismanualandonyourappliance.Alwaysreadandobeyallsafetymessages.Allsafetymes-
sageswilltellyouwhatthepotentialhazardis,tellyouhowtoreducethechanceofinjury,andtellyou
what can happen if the instructions are not followed.
Thisisthesafetyalertsymbol.Thissymbolalertsyoutopotentialhazardsthatcanhurtyouandothers.
Allsafetymessageswillfollowthesafetyalertsymbolandtheword“WARNING”.
Tools needed:
Page3
Level
Flat-bladeand
Phillipsscrew-
drivers
Powered
screwdriver
or drill
Measuring
tape
Utilityknife
Markeror
pencil
Table of Contents
INSTALLATION
Toolsneeded....................................................3
Partssupplied...................................................4
Ventingrequirements.......................................5
Mountheights&clearance...........................5-6
Calculatingventsystemlength.......................6
Ventingmethods&ductlessconversion..........7
Charcoallters&electricalrequirements.......8
Preparation......................................................9
Installation................................................10-12
Range hood operations............................13-22
USE AND CARE
Troubleshooting...........................................23
Useandcareinformation...............................24
Specications..............................................24
MAINTENANCE
Cleaning...............................................25
Replacinglter&lightbulb....................25-26
WARRANTY
Coverage& exceptions.................................27
Disclaimer&contactinformation..................28
Page4
Air diverter
(Optionalre-circulatingkit)
CharcoalFilter
(Optionalre-circulatingkit)
Description Quantity
Toggle Bolts 2Pcs
DuctSet 1Set
BodyHook(varywithmodel) 2Pcs
ChimneyMountingBracket 1Set
ThisGuideandWarrantyCard 1Set
5mmx16mmScrewwithWasher 4Set
Optional:4mmx16mmTappingScrew 6Pcs
Optional;4mmx10mmTappingScrew 16Pcs
Optional:ToggleBoltwithTappingScrewforAirDiverter 2Set
Optional:ScrewforCharcoalFilter 3Pcs
StainlessSteelBafeor
AluminumFilter(s)
Lowerstandardchimney Upperstandardchimney
FlexibleDuctTube(Optional)
Flappers
Parts supplied: Range Hood
(varywithmodel)
MountingBracket
Page5
Max*:110”
Standard
Upper
Chimney
Extensionavailable*
Range hood
Mounting
Bracket
Standard
Lower
Chimney
Extensionavailable*
36”base
Maximum*ceilingclearance
110”at31”hoodmounting
heightabovecountertop/stove
(mayvarywithdifferent
model).Chimneyextensions
availableforhigherceiling.
*Higherceilingrequireschim-
neyextension.Availableatyour
local resellers.
Min:
28”
Max:31”
Venting Requirements Height & Clearance
• Vent system must terminate to the outside
(rooforsidewall).
• DONOTterminatetheventsysteminanat-
tic or other enclosed area.
• DONOTuse4”(10.2cm)laundry-typewall
caps.
• Usemetal/aluminumventonly.Rigidmetal/
aluminum vent is recommended.
• DO NOT use plastic vent.
• Alwayskeeptheductcleantoensureproper
airow.
• Calculatethefollowingguresbeforeinstal-
lation:
1. Distance from the oor to the ceiling.
2. Distance between the oor to the coun-
tertop/stove (recommend* 28” to 31”).
3. Distance between the countertop/stove
to the range hood.
4. Height of hood and duct cover.
For the most efcient & quiet operation:
• Adistance of 28”to31” is recommended*
betweenstove topandthebottom ofrange
hood.
• It is recommended that the range hood be
ventedverticallythroughtheroofthrough6”
(15.2cm) or bigger roundmetal/aluminum
ventwork.
• Thesizeoftheventshouldbeuniform.
• Usenomorethanthree90°elbows.
• Make sure there is a minimum of 24” (61
cm) of straight vent between the elbows if
morethanoneelbowisused.
• DONOTinstalltwoelbowstogether.
• The length of vent system and number of
elbowsshouldbekepttoaminimumtopro-
videefcientperformance.
• The vent system must have a damper. If
roof or wall cap has a damper, DO NOT
usedamper(ifsupplied)ontopoftherange
hood.
• Usesilvertapeorducttapetosealalljoints
intheventsystem.
• Use caulking to seal exterior wall or roof
opening around the cap.
*Duetodifferentceilingheightcongurations,rec-
ommendedheightmaynotbeapplicable.
Countertop/Stove
IMPORTANT:
• Aminimumof6”round(standardforthisrangehood)or3-1/4x10”rectangularduct(purchasedseparately)
mustbeusedtomaintainmaximumairowefciency.
• Flexible6”roundductprovidedforconvenience,alwaysuserigidtypemetal/aluminumductsifavailableto
maximizeairowwhenconnectingtoprovidedduct.
• PleaseuseDuct Run Calculationbelowtocomputethetotalavailableductrunwhenusingelbows,transitions
and caps.
• ALWAYS,whenpossible,reducethenumberortransitionsandturns.Iflongductrunisrequired,increase
ductsizefrom6”to7”or8”.Ifareducerisused,installalongreducerinsteadofapancakereducer.Reduc-
ingductsizewillrestrictairowanddecreaseairow,thusreduceductsizeasfarawayfromopeningaspos-
sible.
• Ifturnsortransitionsarerequired:Installasfarawayfromopeningandasfarapart,between2,aspossible.
• Minimummountheightbetweenstovetoptohoodbottomshouldbenolessthan28-inch*.
• Maximummountheightbetweenstovetoptohoodbottomshouldbenohigherthan31-inch*.
• Itisimportanttoinstallthehoodatthepropermountingheight.Hoodsmountedtoolowcouldresultinheat
damageandrehazard;whilehoodsmountedtoohighwillbehardtoreachandwilllooseitsperformance
andefciency.
• Ifavailable, alsorefer to stovetop manufacturersheight clearance requirementsand recommendedhood
mountingheightaboverange.
*Duetodifferentceilingheightcongurations,recommendedheightmaynotbeapplicable.
Minimum Duct Size:
• Round-6”minimum
• Rectangular-3-1/4x10”minimum(requiresa6”to3-1/4x10”adaptor,notsupplied)
Page6
Duct Run Calculation:
Recommendedmaximumrun
6”or3-1/4x10”duct 50ft
Ventpiecededuction
Each90ºelbowused 9ft
Each45ºelbowused 5ft
Each6”to3/14x10”transitionused 7ft
Sidewallcapwithdamper 0ft
Roof cap 0ft
Duct Run Calcuation example:
One roof cap, two 90º elbow, and one 45º elbow used:
0ft + 9ft + 9ft + 5ft = 23ft used.
Deduct 23ft from 50ft, 27ft maximum available for
straight duct run.
Tocalculatethelengthofthesystemyouneed,deducttheequivalentfeetforeachventpieceusedinthesystem
fromtherecommendedmaximumductrun.
Calculating Vent System Length
Venting Methods
Page7
• Thisrangehoodisfactorysetforventingthroughtherooforwall.Fornon-vented(re-circulating)installa-
tions,seeRecirculating (Non-Vented) KitonPage11.
• Ventworkcanterminateeitherthroughtherooforwall.Toventthroughawall,a90°elbowisneeded.
IMPORTANT:
• NEVERexhaustairorterminateductworkintospacesbetweenwalls,crawlspaces,ceiling,atticsorgarages.
Allexhaustmustbeductedtotheoutside.
• Usemetal/aluminumductworkonly.
• FastenallconnectionswithsheetmetalscrewsandtapealljointswithcertiedSilverTapeorDuctTape.
• Usecaulkingtosealexteriorwallorroofopeningaroundthecap.
Ductless Conversion
Option 2:
Sidewallcap
Vertical roof venting
Roof cap
Horizontal wall venting
Option 1:
• Ductlessconversionisintendedforapplicationswhereanexhaustductworkisnotpossibletobeinstalled.
Whenconverted,thehoodfunctionsasapurifyinghoodratherthananexhausthood.Fumesandexhaust
fromcookingisdrawnandlteredbyasetofcharcoallters.Theairisthenpuriedandre-circulatedback
within the home.
• WerecommendtoALWAYSexhaustairoutsideofthehomebyemployingexistingorinstallingnewduct
work,ifpossible.Onlywhentheexhaustoptionisnotpossibleshouldyourecoursetoconvertingthehood
intoapurifyingunit.
• Whenconvertedtobea“purifying”unit,asetofcharcoalltersandanair-diverterarerequiredinadditionto
itsstandardaluminumlterset.Availableatyourlocalresellers.Thestandardaluminumltersareintended
tocaptureresiduefromcooking,theoptionalcharcoalltershelptopurifyfumesexhaustedfromcooking,
andtheoptionalair-diverterredirectslteredcleanairbacktothehouse.
Page8
Electrical Requirements
IMPORTANT:Observeallgoverningcodesandordinances.
It is the customer’s responsibility:
Tocontactaqualiedelectricalinstaller.
ToassurethattheelectricalinstallationisadequateandinconformancewithNationalElectricalCode,ANSI/
NFPA70—latestedition*,orCSAStandardsC22.1-94,CanadianElectricalCode,Part1andC22.2No.0-M91
-latestedition**andalllocalcodesandordinances.
• Ifcodespermitandaseparategroundwireisused,itisrecommendedthataqualiedelectriciandetermine
that the ground path is adequate.
• A120-volt,60Hz,AC-only,fusedelectricalsupplyisrequiredonaseparate15-ampcircuit,fusedonboth
sides of the line.
• Do not ground to a gas pipe.
• Do not have a fuse in the neutral or ground circuit.
• RISKOFELECTRICALSHOCK.Thisrangehoodmustbeproperlygrounded.Checkwithaqualiedelec-
tricianifyouarenotsurewhethertherangehoodisproperlygrounded.
• Therangehoodshouldbeconnecteddirectlytothefuseddisconnect(orcircuitbreaker)boxthroughexible
armoredornon-metallicsheathedcoppercable.AU.L.-orC.S.A.-listedstrainreliefmustbeprovidedat
eachendofthepowersupplycable.Donotuseextensioncordoradapterplugwiththisappliance.
• Therangehoodmustbeconnectedwithcopperwire/plugonly.
• Alwaysuseplug provided.Ifnot possible, connectthreewires according toitscolor (blacktohot, white
to neutral, and green to ground)
to house wires and cap with wire
connectors:
Wire sizes (copper wire only) and
connections must conform with
the rating of the appliance as speci-
ed on the model/serial rating label. Wire sizes must conform to the requirements of the National Electrical
CodeANSI/NFPA 70 — latest edition*, or CSA Standards C22. 1-94, Canadian Electrical Code Part 1 and
C22. 2 No.  0-M91 - latest edition** and all local codes and ordinances.A U.L. - or C.S.A. - listed conduit
connectormustbeprovidedateachendofthepowersupplycable(attherangehoodandatthejunctionbox).
Copiesofthestandardslistedmaybeobtainedfrom:
*NationalFireProtectionAssociation ** CSAInternational
BatterymarchPark   8501EastPleasantValleyRoad
Quincy,Massachusetts02269  Cleveland,Ohio44131-5575
Charcoal Filter Installation
White
Green
Black
NOTE: Thecharcoalltersarepreinstalledifyoupurchasedtherangehoodwithre-circulatingkitfromus.
1. Removealuminumltersonhood.
2. Removethesafetylterunderthealuminumlterbyunscrewingtwoscrews,thenpositionthecharcoallter
andalignthescrewholes,reinstallandfastentwoscrews.
3. Reinstallthealuminumltersbacktothehood.
4. Charcoalltersmustbereplacedafter120hoursofuse(orapproximatelyevery2to3monthsbasedonthe
averageof1to2hoursofdailycookingtime).Availableatyourlocalreseller.
Page9
Advanced Preparations:
1. Readtheentireinstallationguideandusersmanualthoroughly,understandinstructionsandwarnings.
2. BefamiliarwiththecontrolsoftherangehoodbyreadingthroughRange Hood Operations,Page13.
3. Placetherangehoodonaat,stablesurface.Connecttherangehoodtoadesignatedstandardoutlet(please
refertheproductlabelforthesuitablevoltageofthisunit)andverifynodebrishasenteredtheventopenings,
thenturnontherangehood.VerifyalloperationsoftherangehoodbyreferringtoRange Hood Operations,
Page13.
4. Placeallsuppliedpartsandrequiredhardwareonaat,stablesurfaceandverifytheexistenceofallsupplied
partslistedonPage4.
5. Carefullyremovethewhiteplasticprotectivecoatfromthechimneycoversandrangehood.
Preparations:
NOTE: To avoid damage to your hood, prevent debris from entering the vent opening.
1. Determineandmarkthecenterlineontheceilingwheretherangehoodwillbeinstalled.Makesurethereis
properclearancewithintheceilingorwallforexhaustvent.
2. Duetotheweightandsizeofthisunit,pleasemakesurethatthesupportsystemorframeworkbeingusedis
stableandsecureintheceiling.
3. Putathick,protectivecoveringovercountertop,cooktoporrangetoprotectfromdamageordirt.Remove
anyhazardousobjectsaroundtheareawheninstalling.
4. Markthelocationsofthesupportmountingbracketholes,ventcutout(ifused)andpowersupplycablecutout
ontheceiling.Usedrillandsabersaworkeyholesawtocutopeningsforpowersupplycableandvent(see
Venting requirements and Electrical requirements,Pages5-8).
5. Ifventingtotheoutsideinstallventsystem(seeVenting Methods,Page7).Usecaulkingtosealexteriorwall
or roof openings.
6. Disconnectmainelectricalsupply,prepareandrunelectricalwiringthroughceiling.Leaveapproximately
12”ofelectricalcordhangingfromtheceiling.Donotrestorepoweruntilwiringiscompleted.
7. Disconnectpowercord,removethealuminumlterbypressingonthelatchandgentlypullthealuminum
lterdown.
8. Ifcharcoallterispresent,unscrewthetwoscrewsandremovethelter.
9. Setasidethealuminumltersandcharcoallteruntiltherangehoodisproperlyinstalled.
10. If the range hood comes with a glass canopy and has not already been mounted to the hood, loosen the four
canopy screws and washers from the hood top, carefully place the canopy on the hood top, and loosely tighten
the four canopy screws along with washers. DO NOT put excessive pressure against the glass.
WARNING
Severe Injury
Rotating fan can cause
severe injury. Stay clear of
fan when motor is running.
WARNING
Severe Injury
Hood may have very shape edges. Please wear
protective gloves if it is necessary to remove
any parts for installing, cleaning or servicing.
Preparation
WARNING
Excessive Weight
Require three or more person to move and
install this range hood. Spinal or other bodily
injuries could occur if it is not followed.
Page10
3. Install the Duct Set using six 4mm x 16mm Tapping
Screws,theninstallAluminumDuctTubeasshownin
Figure3Aand3B.Proceedtostep6onPage12.
Figure2
Installations(refertoPage4forparts):
Due to excessive weight, two or more person is recommended for this step.
1. Locateanoptimallocationtoplacetherangehood.Markthe
levelingpointsfortwoBodyHooks(Figure1)onthewalland
drilltwoholeswithdiameternotexceeding5/8”.Inserttwo
toggleboltsthenfastentwo4mmx16mmTappingScrews,
reserveapproximately1/8”forthebodyhooks.Besuretouseappropriateanchorsforyourwall.
2. Find an optimal loca-
tionfortheChimney
Mounting Bracket.
Thechimneymount-
ing bracket must be
placed directlyabove
and align with the
two body hooks, see
Figure 2. Drill two
more holes with di-
ameternotexceeding
5/8” and insert two
toggle bolts. Secure
the chimney mount-
ingbracket withtwo
4mmx 16mmTappingScrewsas shown
inFigure2.Besuretouseappropriatean-
chorsforyourwall.Usefoursetsof5mm
x16mmScrewwithWashertoinstallthe
bodyhooksontothehood.Thenhangthe
hood on the wall and tighten the screws.
CAUTION: MAKE SURE the range hood
is secure before releasing!
Figure3A
Figure1
DuctSet
InstalltheDuctSet
and Aluminum duct
onthebodyofhood. Figure3B
Installation
If Recirculating (Non-Vented) Kit is purchased, please skip this step and proceed to Page 11.
WARNING
Excessive Weight
Require three or more person to move and
install this range hood. Spinal or other bodily
injuries could occur if it is not followed.
DuctSet
Page11
4. Find an optimal location for the Air Diverter. The air diverter must be placed directly above and align
with the two body hooks, see Figure 4. Drill four more holes with diameter not exceeding 5/8” and in-
sert four toggle bolts. Secure the air diverter with four 4mm x 16mm Tapping Screws as shown in Fig-
ure 4. Be sure to use appropriate anchors for your wall. Use four sets of 5mm x 16mm Screw with
Washer to install the body hooks onto thehood.Then hang the hoodon thewall andtighten thescrews.
CAUTION: MAKE SURE the range hood is secure before releasing!
Figure4
5. InstallAluminumDuctTubeasshowninFigure5A.In-
stallationofcharcoallterduringthisstepisalsorecom-
mended,pleaseseeCharcoal Filter InstallationonPage
8.
Figure5B
Figure5A
Air Divertor
SafetyFilter
Charcoal
Filter
Installation (Continued)
If Recirculating (Non-Vented) Kit is NOT purchased, please go back to step 2 on Page 10.
WARNING
Excessive Weight
Require three or more person to move and
install this range hood. Spinal or other bodily
injuries could occur if it is not followed.
Page12
6. Connecttheducttubetotheexteriorexhaustsystemortheoptionalairdiverter.Makesurealljointsaresecure
and air tight. Use of duct tape is recommended.
7. PlaceUpperChimneyandLowerChimneyoverthebodyofthehoodasshowninFigure7A(orFigure7Bof
airdiverterispresent).Slideuptheupperductcovertowardsthechimneymountingbracketortheoptional
airdiverter.Usefour4mmx10mmTappingScrewstosecuretheupperchimneyontothechimneymounting
bracketortheoptionalairdiverter.Finallysecurethelowerchimneytothehoodbodybyusingtwo4mmx
10mmTappingScrews.
Page12
Figure7A
Figure7B Air Divertor
Upper
Chimney
(hasvent-
ingholes)
Lower
Chimney
ChimneyMountingBracket
Upper
Chimney
(hasvent-
ingholes)
Lower
Chimney
4x10Screw
4x10Screw
4x10Screw
4x10Screw
Installation (Continued)
WARNING
Excessive Weight
Require three or more person to move and
install this range hood. Spinal or other bodily
injuries could occur if it is not followed.
Page13
PowerSwitch
LowSpeed
MediumSpeed
HighSpeed
LightSwitch
Range Hood Operations & Wiring Diagram
TurnOn:
• Pressthespeedcontrol(LowSpeed,MediumSpeed,HighSpeed)switchtoselectthedesiredlevelofpower.
Oncebuttonispressed,thepreviousspeedmodewillcancel.
• PresstheLightSwitchtopoweronthelights.
CAUTION: DO NOT touch the lights until switched OFF and cooled.
TurnOff:
• PressthePowerSwitchtoturnoffthepower.
• PresstheLightSwitchtopoweroffthelights
SV200SeriesStandardClass(3SpeedMechanicalControl)
NOTE:WiringDiagramsshownabovewithGU10lightconguration.AtransformerisrequiredforMR16Lights.
SV200SeriesStandardClassWiringDiagram
Page14
Power
DecreaseValue
Light
IncreaseValue
BlowerPowerIndicator
BlowerSpeedIndicator
Power-OnElapsedDigitalTimer
Power-OffDelayDigitalTimer
Power-OffDelayTimerIndicator
LightPowerIndicator
Thisrangehoodisdesignedtoremovesmoke,cookingvaporsandodorsfromthecooktoparea.Forbestresults,
starttherangehoodbeforecookingandallowittooperateseveralminutesafterthecookingiscompletedtoclear
allsmokeandodorsfromthekitchen.
• Buttonfunctions:
• Power:PowerON/OFFtherangehoodandactivatepower-offdelaytimer.
• DecreaseValue:Blower(motor)speeddecrease,timervaluedecrease,andentertimermode.
• IncreaseValue:Blower(motor)speedincreasetimervalueincrease,andcumulativetimerreset.
• BlowerPowerIndicator:Lightsupwhenblower(motor)isrunning.
• BlowerSpeedIndicator:Showscurrentblower(motor)speed(1-6).
• LightPowerIndicator:Lightsupwhenlightsturnedon.
• Light:TurnsON/OFFanddimhalogenlights.
• Power-OnElapsedDigitalTimer:Indicatestheaccumulatedtimethesystemisrunning.
• Power-OffDelayDigitalTimer:Indicatesthelengthoftimeleftfordelayofffunction.
• Power-OffDelayTimerIndicator:Lightsupwhenauto-shutdowndelaytimerfunctionison.
• Controls:
• Automaticcleaningreminder:
• Thisrangehoodisequippedwithacleaningreminderthatwillactivatefollowing30hoursofuse.
Whenblower(motor)startstorotate,cumulativerunningtimewillbeshowninPower-On Elapsed
Digital Timer.Thistimericonasheswhen30hoursisupandremindsusertocleanthealuminum
lter.
• Aftercleaningthelterandwhenthemotorisnotinuse,pressandholdIncrease Valuebuttonover3
secondstoresetthetimer.PleasenotethatturningoffthesystemwillnotresetthePower-On Elapsed
Digital Timer.
• Adjustingtheblower(motor)speed:
• PressPowerbuttononcetoturnonthesystem.TheBlower Power Indicatoriconashesshowingthat
theblower(motor)isready.Decrease Valuebuttonwilldecreasethespeedoftheblower(motor)from
6to1(strongesttoquietest).Increase Valuebuttonwillincreasethespeedoftheblower(motor)from
1to6(quietesttostrongest).
• PressPowerbuttononcetoturnoffthesystem.
Note: The system saves user congurations, settings such as light, timer and blower (motor) speed will re-
main the same the next time it is turned on.
Range Hood Operations & Wiring Diagram (Continued)
SV168/198Series“E”Class(6SpeedElectronicTouchControl)
Page15
• Controls:
• Adjustingthetimerfunction:
• Whiletheblower(motor)isnotrunning,pressandholdDecrease Value buttonover3secondsto
entertimermode.AdjusttodesiredperiodofdelayofftimerbypressingIncrease Value or Decrease
Valuebutton(minimum1minutetomaximum15minutes).Thissettingwillbesavedimmediately.
• Activatingthetimerfunction:
• Whiletheblower(motor)isrunning,pressandholdPower buttonforover3secondstoactivate
delayofftimer.Power-offdelayindicatorwilllitupandpower-offdelaydigitaltimerwillbeginto
countdown,whenitreacheszero,theblower(motor)willshutdown.
• Adjustingthelight:
• PressLightbuttononcetoturnonthelights,andonceagaintoturnoffthelights.
• Whilethelightsareoff,pressandholdLightbuttonforover3secondstodimthelightsfromlowto
high.Levelofbrightnesswillbestoredinsystem’smemory.
CAUTION: DO NOT touch the lights until switched OFF and cooled.
Note: Light settings are independent from other settings (including power-off delay) and lights has to be
manually turned on or off.
Note: The system saves user congurations, settings such as light, timer and blower (motor) speed will re-
main the same the next time it is turned on.
Power
DecreaseValue
Light
IncreaseValue
BlowerPowerIndicator
BlowerSpeedIndicator
Power-OnElapsedDigitalTimer
Power-OffDelayDigitalTimer
Power-OffDelayTimerIndicator
LightPowerIndicator
Range Hood Operations & Wiring Diagram (Continued)
SV200Series“E”Class(6SpeedElectronicTouchControl)
Page16
Wiring Diagram
SV200Series“E”ClassWiringDiagram(6SpeedwithGU10Bulb)
Page17
Troubleshooting
1. Iftherangehoodorhalogenlightdoesnotoperate
afterinstallation:
• Checkiftherangehoodhasbeenpluggedin,make
surethatallpowerhasbeenturnedbackON,fused
notblownandallelectricalwiringareproperlycon-
nected.
• Swapoutlightassemblytoworkingonestodeter-
minewhetheritiscaused by defectivebulbs. See
Replacing the light bulbsonPage22-23.
2. Therangehoodvibrateswhentheblowerison: • Therangehoodmightnothavebeensecuredprop-
erlyontotheceilingorwall.Checkwithyourin-
staller
3. Theblowerorfanseemsweak: • Checkthattheductsizedusedisatleast6”or3-1/4
x10”.RangehoodWILLNOTfunctionefciently
with insufcient duct size. For example: 8” duct
over6”holeandlooselysecured.
• Checkifductiscloggedorifdamperunit(half-cir-
cularapper)isnotinstalledcorrectlyoropening
properly.Atightmeshonasidewallcapunitmight
alsocauserestrictiontotheairow.
4. Thelightsworkbuttheblowerisnotspinningatall,
isstuckorisrattling.
• Theblowermightbejammedorscrapingthebot-
tomduetoshippingdamage.Pleasecontactusim-
mediately.
5. Thehoodisnotventingoutproperly: • Makesurethedistancebetweenthestovetopand
thebottomofthehoodiswithin*28”and31”in
distance.*Due to different ceiling height congura-
tions, recommended height may not be applicable.
• Reduce the number of elbows and length of duct
work. Check if all joints are properly connected,
sealed,andtaped.
• Make sure the power is on high speed for heavy
cooking.
NOTE: For all other inquiries, please contact your SPAGNA VETRO local reseller.
6. Purposeoftheslots/holes/openingsnearthetopof
theupperchimney:
• These slots/holes/openings are used to exhaust
cleanedairwith optional re-circulatingkit.Ifyou
didnotinstallone,youdonotneedthem.
Page18
Specications*:
Body StainlessSteel/TemperedGlass
PowerRating 120V/60Hz(USA&Canadastandard)
GeneralInputPower 160W+#ofLightxVotageofLight
MotorInputPower 160W
Motor Revolution 800RPM(±10%)to1300RPM(±10%)
LevelsOfSpeedControl 3Levels
MaximumAirow 600CFM
AirPressure 150Pa(200PaMaximum)
NoiseLevel(dB/sone) Approximately35/0.7to67/6.5(LowesttohighestSpeed)
MotorType SingleChamberUltraQuiet
FanType Centrifugal/Sirocco
ControlType 3SpeedMechinicalorElectronicTouch
FiltrationType AluminumFilterorStainless
Illumination 35W(GU10)110VMax.
VentingSize Top,6inchesRound
InterferenceProtection RadioFrequencyInterferenceProtected
Specications
Use and Care Information
Operations:
• Readandunderstandallinstructionsandwarningsinthismanualbeforeoperatingtheappliance.Savethese
instructions for future reference.
• Alwaysleavesafetygrillsandltersinplace.Withoutthesecomponents,operatingblowerscouldcatchonto
hair,ngersandlooseclothing.
• NEVERdisposecigaretteashes,ignitablesubstances,oranyforeignobjectsintoblowers.
• NEVERleavecookingunattended.Whenfrying,oilinthepancaneasilyoverheatandcatchre.Theriskof
selfcombustionishigherwhentheoilhasbeenusedseveraltimes.
• NEVERcookon“open”amesundertherangehood.Checkdeep-fryersduringuse:Superheatedoilmaybe
ammable.
Cleaning:
• Thesaturationofgreasyresidueintheblowerandltersmaycauseincreasedinammability.Keepunitclean
andfreeofgreaseandresiduebuild-upatalltimestopreventpossibleres.
• Filtersmustbecleanedperiodicallyandfreefromaccumulationofcookingresidue(seecleaning instructions
onPage22).Oldandwornltersmustbereplacedimmediately.
• Donotoperateblowerswhenltersareremoved.Neverdisassemblepartstocleanwithoutproperinstruc-
tions.Disassemblyisrecommendedtobeperformedbyqualiedpersonnelonly.Readandunderstandall
instructionsandwarningsinthismanualbeforeproceeding.
*Subjecttochangewithoutnotice,pleasecontactyourlocalresellerfordetails.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26

Spagna Vetro SV190 Series Installation Manual And User's Manual

Category
Cooker hoods
Type
Installation Manual And User's Manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI