KUSSMAUL AUTO ISOLATOR I User manual

Type
User manual
FILE: 091-139-002
DATE: 04-23-01
REV.A: 2/24/04
INSTRUCTION MANUAL
AUTO ISOLATOR I
AN AUTOMATIC LOSSLESS BATTERY ISOLATOR
FOR DUAL BATTERY SYSTEMS
MODEL# 091-139-2-12
BATTERY VOLTAGE: 12 VDC
OUTPUT: 12 VOLTS, 3 AMPS
BATTERY PARALLELING SOLENOID: 200 AMPS
3 YEAR WARRANTY
INTRODUCTION
The Model 091-139-2-12 AUTO ISOLATOR I system is a lossless isolator
replacement for the conventional diode isolator. Designed to be installed in a
vehicle with one or more Main batteries that must be isolated from one or more
auxiliary batteries. The system consists of a voltage detector and controller
Model 091-139-CONT-12 and a separate 200-ampere rated solenoid, Model
091-139-SOL-12HO for switching the batteries. In addition to maintaining battery
isolation the AUTO ISOLATOR I may parallel the batteries on engine starting if
the auxiliary battery has sufficient charge to assist in the cranking. A block
diagram of the system appears in figure 1.
ALTERNATOR
MAIN
BATTERY
AUXILIARY
BATTERY
PARALLELING
SOLENOID
STARTER
SOLENOID
STARTER
PUSH BUTTON
MAIN
BATTERY
VOLTAGE
DETECTOR
AUX.
BATTERY
VOLTAGE
DETECTOR
STARTER
ISOLATOR SOLENOID
DRIVER
POWER
IGNITION
SWITCH
TIMER
Figure 1
Block Diagram
MAIN BATTERY SENSE
AUXILIARY BATTERY SENSE
SYSTEM OPERATION
The system receives its power from the ignition switch. With the switch “OFF” all
the power is removed from the system and the solenoid is deenergized.
As soon as the operator turns the ignition “ON”, the system is powered and
detects the voltage of the main and auxiliary batteries. If the auxiliary battery
voltage is 12.4 volts or greater, (indicating sufficient charge) cranking the engine
will cause the paralleling solenoid to be energized. A 10-second timer will
maintain the paralleling solenoid if the engine doesn’t start immediately and must
be cranked a second time. When the engine starts the alternator output raises
the battery voltage. This increase in voltage is detected and the paralleling
solenoid is held energized charging both batteries.
If when the engine is started the auxiliary battery voltage is below 12.0 volts the
paralleling solenoid is not energized while cranking. As soon as the engine
starts, the alternator raises the main battery voltage and the solenoid is
energized charging both batteries.
Upon engine shutdown the ignition switch is placed in the “OFF” position. Power
is removed from the Auto Isolator and the solenoid is deenergized.
INSTALLATION
Install the 091-139-CONT-12 Controller is a suitable location protected from the
weather and engine heat. The 091-139-SOL-12HO Solenoid may be mounted in
the engine compartment or at a location to minimize the length of the battery
cables. Install wiring per figure 2.
MAIN
BATTERY AUXILIARY
BATTERY
PARALLELING
SOLENOID
1 2 3 4 5 6 7 8
+12VOLT
FROM
STARTE
R
+
12VOLT
F
RO
M
GNITION
S
WITC
H
Model 091-139-12
AUTO ISOLATOR I
INSTALLATION WIRING
Figure 2
THIS LINE SUPPLIES
THE POWER TO OPERATE
THE SYSTEM
SENSE LINE, CONNECT
DIRECTLY TO BATTERY
SENSE LINE, CONNECT
DIRECTLY TO BATTERY
THIS LINE ENERGIZES THE
SOLENOID AT ENGINE START
IF THE AUXILIARY BATTERY
HAS SUFFICIENT VOLTAGE
TO PROVIDE A BOOST
NOTE POLARITY OF
FLYBACK DIODE
ALL WIRES #16 AWG EXCEPT AS NOTED
#2 AWG MIN.
091-139-CONT-12
AUTO ISOLATOR I CONTROLLER
Note: Red Dot
CALIBRATION
The voltage setpoints may be altered in the field to suit particular customer
requirements. Adjustments are provided to adjust the main battery voltage at
which the paralleling solenoid is energized. An additional adjustment permits
adjusting the voltage below which the auxiliary battery will not be paralleled for
starting boost.
MAIN BATTERY VOLTAGE ADJUST
AUXILIARY BATTERY VOLTAGE ADJUST
INDICATOR ILLUMINATED WHEN MAIN
BATTERY VOLTAGE IS ABOVE SETPOINT
13.3 VOLTS
INDICATOR ILLUMINATED WHEN
AUXILIARY BATTERY VOLTAGE IS
ABOVE SETPOINT, 12.0 VOLTS
MEASURE AUX. BAT. VOLTAGE HERE
MEASURE MAIN BAT. VOLTAGE HERE
ILLUMINATES DURING
ENGINE CRANKING
CW INCREASES VOLTAGE
Figure 3
VOLTAGE ADJUSTMENTS
AUTO ISOLATOR 1
R20
CR3
CR4
R16
I3
U5
U2
I4
87654321
C4
U4
R2
R21R1
R3
U3
+
C5
C3
C2
+
R11
R12
R9
I2
CR2
CR1
J1
R7 R18
R8
R15
STARTER
MAIN
BAT.
OK
AUX.
BAT.
OK
OUTPUT
MAIN AUX.
CI1 R10
KUSSMAUL ELECTRONICS CO
B091-139-002
R6
C6
R13
C7
I1
R4
R19
R17
Q1
GND
VCC+
C1
U1
AUX
MAIN
SPECIFICATION AND OUTLINE
CONTROLLER, Model 091-139-CONT12
Volts to parallel: 13.3 volts, field adjustable
Battery load: .000125 amps.
Output current: 3 amps
Weight: .4 lbs.
SOLENOID, Model 091-139-SOL-12HO
Volts: 12 volts D.C.
Coil current: .65 amps
Contact rating: 200 amps
OUTLINE, AUTO ISOLATOR I CONTROLLER, 091-139-CONT12
3.30
3.60
2.80
OUTLINE, AUTO ISOLATOR I SOLENOID, 091-139-SOL-12HO
3/16" DIA.
4,50 1.55
2.95
5.10
INSTALLATION RECORD & WARRANTY
Date Installed________________________________________
Installed By___________________________________________
Vehicle Identification_________________________________
Vehicle Owner________________________________________
WARRANTY
All products of Kussmaul Electronics Company Inc. are warranted to be free of
defects of material or workmanship. Liability is limited to repairing or replacing at
our factory, without charge, any material or defects which become apparent in
normal use within 3 years from the date the equipment was shipped. Equipment
is to be returned, shipping charges prepaid and will be returned, after repair,
shipping charges paid.
Kussmaul Electronics Company, Inc. shall have no liability for damages of any
kind to associated equipment arising from the installation and /or use of the
Kussmaul Electronics Company, Inc. products. The purchaser, by the
acceptance of the equipment, assumes all liability for any damages which may
result from its installation, use or misuse, by the purchaser, his or its employees
or others.