Kardioline KL150 User manual

Category
Blood pressure units
Type
User manual
• Introduction 1
• ImportantSafetyNotes 2
• KnowYourUnit 3
• BatteryInstallation/Replacement 4-5
• ProperWayofMeasurement 6-9
• TakeaMeasurement 10-11
• UsetheMemoryFunction 12-13
• AboutBloodPressure 14-15
• ExceptionalSituations 16-17
• CareandMaintenance 18-19
• Specications 20-21
• Statement 22
• WarrantyInformation 23
ShangHai International Holding Corp. GmbH (Europe)
Eiestrasse80|20537Hamburg|Germany
SHENZHEN KINGYIELD TECHNOLOGY CO., LTD. |SectionC1~2,FuHai
IndustrialZone,FuYongTown,BaoAnDistrict,ShenZhen,GuangDong,518103,P.R.C
Table of Contents
M
E
M
M
E
M
P
U
L
/
m
i
n
D
I
A
S
Y
S
Kardioline Swiss GmbH
Oberbüntelistrasse14|CH-9443Widnau|Switzerland
www.kardioline.com
Instruction Manual
Digital Blood Pressure Monitor
FullyAutomaticWristStyle
ModelNo.:KL150
Thankyoufor purchasing Kardioline Fully AutomaticWrist Style Digital Blood
Pressure Monitor. The unit uses the oscillometric method of blood pressure
measurement.Itmeanstheunitdetectsthemovementofyourbloodthrough
yourartery,andconvertsyourbloodpressureintoadigitalreading.Theunitis
simpletousebecauseastethoscopeisnotneededwhileusinganoscillometric
monitor.Theunitstoresautomatically60setsofmeasurementvalues.Youcan
readthestoreddataconvenientlybypressingthememorybuttons.
TypeBappliedpart
Attentionsign.Consultaccompanydocuments
Symbolforthemarkingofelectricalandelectronicsdevicesaccording
toDirective2002/96/EC.Thedevice,accessoriesandthepackaginghave
tobedisposedofwastecorrectlyattheendoftheusage.Pleasefollow
LocalOrdinancesorRegulationsfordisposal.
Introduction
1
•
Readallinformationsintheinstructionmanualandanyotherliterature
includedintheboxbeforeusingtheunit.
•
Contactyourphysicianforspecicinformationaboutyourbloodpressure.
Followtheinstructionsofyourhealthcareprovider.
•
Operatetheunitonlyasintended.Don‘tuseforanyotherpurpose.
•
Theunitisintendedtouseinmeasuringbloodpressureandpulseratefor
adultonly,notrecommendedforneonatalbaby.
•
Donotuseacellularphoneneartheunit.Itmayresultinoperationalfailure.
•
Pleaseavoidusinginhighradiantareainordertomakeyourmeasuringdata
correctly.
•
Donotdisassembleorattempttorepairtheunitorcomponents.
•
Donotusetheequipmentwhereammablegas(suchasanestheticgas,
oxygenorhydrogen)orammableliquid(suchasalcohol)arepresent.
• Usetwoidentical1.5ValkalinebatteriestypeAAALR03.
• Replaceallofthebatteriesifthesymboloflowbattery
appearsonthedisplay.
• Neverleaveanylowbatteryinthebatterycompartment
sincetheymayleakandcausedamagetotheunit.
1.Removethebatterycover
fromthebatterycompartment.
3.Replacethebatterycover
2.InserttwoAAApowerfulbatteries
intothecompartmentandensure
eachbatteryisintheproperdirection.
To assure the correct use of the product basic safety measures should
always be followed including the precautions listed below:
Battery Installation / Replacement Battery Installation / Replacement
Important Safety Notes Know Your Unit
M
E
M
M
E
M
P
U
L
/m
in
D
I
A
S
Y
S
Body&Cu
Power
2xAAAAlkaline
Batteries
Display
Display
Start/StopButton
MemoryButtons
BatteryCompartment
WristCu
LowBatterySymbol
Ination/DeationSymbol
orWHOindication
SystolicBloodPressure
DiastolicBloodPressure
UnitIndication
PulseDisplay
HeartbeatSymbol
Memory&Times
ArrhythmiaSymbol
Each of Components
How to Install Battery
MEM
MEM
P
U
L
/
m
i
n
D
I
A
S
Y
S
MEM
MEM
P
U
L
/
m
i
n
D
I
A
S
Y
S
P
U
L
/
m
i
n
D
I
A
S
Y
S
MEM
MEM
Caution!
Warning:donotuse
rechargeablebatteries
2
4
3
5
Proper Way of Measurement
Proper Way of Measurement
Proper Way of Measurement
Proper Way of Measurement
1.Removeallclothesfromyourarmallowing
thecutotdirectlyontheskin.
2.Wrapthecutightlyaroundyourwristby
usingtheVelcrostrip.
M
E
M
M
E
M
P
U
L
/
m
i
n
D
I
A
S
Y
S
1cm
Fingers pose Wrist’s pose
Not good Not good
Good Good
Not Good Not Good
1. Turnyourpalmupwards,stretchyourngersandwristnaturally.
2. UseasoftstubelowtheBPmonitortosupportyourarmasthegureshown
below.
3. Keepyourwristatthesamelevelofyourheart.
4. Situprightinachair,andtakeabout10timesdeepbreathtorelaxyourentire
body,especiallybetweenyourelbowandngers.Thenturnontheunitand
starttomeasure.
6
8
7
9
Take a Measurement
Use the Memory Function
Take a Measurement
Use the Memory Function
How to Use the Memory Function To read the memory values
To clean out the memory values
1.PresstheSTART/STOPbutton.
3.Thebloodpressureandpulseratearedisplayedwhenthemeasurement
completed.
4.PresstheSTART/STOPbuttontoturnotheunit.
2.Measurementstartswhileinating.
Alldisplaysymbolsappearonthescreen.Thecustartstoinateautomatically.
Thecuisdeatedautomatically,and
themeasurementresultsarestoredin
thememory.Thesymbolwillbe
displayedifarrhythmiaisdetected.
Theunitwillautomaticallyturnoafter
two minutes if you have forgotten to
turnoit.Pleasehavearestforabout
30~60secondsbeforetakingyournext
measurement.
Theheartbeatsymbolashesonceapulseisdetected.
How to Take a Measurement
MEM
MEM
PUL
/min
DIA
SYS
Allsymbolsdisplay Deatingautomatically Starttoinate
Starttoinate
Inating
Heartbeatappear
ContinueInating Toatpressure
“IHB“display“mmHg“display“kPa“display
OROR
MEM
MEM
PUL
/min
DIA
SYS
• Theunitstoresthebloodpressureandpulserateinthememoryaftercompleting
ameasurementeverytime.Itcanautomaticallystore60setsmeasurement
values.Theearliest recordis deleted to savethe latestmeasurement value
whenmorethan60sets.
• Theunitalsocalculatesanaveragereadingbasedonthevaluesofthelatest3
timesmeasurementtaken.
• Thesymbol„M“andtherelativetimeswillappearatthesametimeafteryou
pressthememorybuttons.
• To read the average value - Pressthememorybutton.Theaveragevalue
willdisplayonthescreenwiththeaveragereading.
• Pressthememorybuttontoviewthelatestmeasurementvalue.
• Pressthememorybuttontoviewtheearliestmeasurementvalue.
• Pressthebuttonsrepeatedlytodisplaythenext/previousvalue.
• When reading the measurement
values,pressandholdthememory
button, then press START/STOP
buttonfor3~4seconds.
MEM
MEM
PUL
/min
DIA
SYS
TheAverage
measurementvalue
The1stlatest
measurementvalue
Turntonext
Backward
Forward
The60thlatest
measurementvalue
The2ndlatest
measurementvalue
The1stlatest
measurementvalue
MEM
MEM
PUL
/min
DIA
SYS
MEM
MEM
PUL
/min
DIA
SYS
10
12
11
13
About Blood Pressure
Exceptional Situations
About Blood Pressure
Exceptional Situations
Error Indicators Eliminate Fault
Thebloodcirculationisresponsibleforsupplyingthebodywithoxygen.Blood
pressureisthepressureexertedonthearteries.
Thesystolicbloodpressurevalue(higherpressureortopvalue)representsthe
bloodpressureproducedbycontractionoftheheartmuscle.
Thediastolicbloodpressurevalue(lowerpressureorlowervalue)representsthe
bloodpressureproducedbyrelaxationoftheheartmuscle.
Note:Whenaperson’ssystolicanddiastolicpressuresfallintodierentcategories,thehighercategory
shouldapply.
Aftereachmeasurementiscompleted,theLCDdisplaywillshowyourposition
automaticallyonthesixsegmentsofthebarindicatorwhichcorrespondsto
WHOBloodPressureIndicator.
Blood Circulation Classification of Blood Pressure
The following symbol will appear on the display when measuring abnormal.
Systolic Blood Pressure
Diastolic Blood Pressure
Contractionof
theheartmuscle
Relaxationof
theheartmuscle
Extrudeblood
Bloodreturnheart
Pressuredecreasedto
thebloodvessel
Pressureincreased
tothebloodvessel
Higherpressure
Lowpressure
Symbol
Problem
Cause Correction
Causes and Solutions
Thecourseof
inatingappears
error.
Replaceallthewornbatterieswithtwonew
ones.
Check the battery installation for proper
placementofthebatteriespolarities.
Nopower.
No display appears on the
displayscreen.
Measurementvalues
appeartoohighortoolow.
Bloodpressurevariesconstantly.Manyfactors
includingstress,timeofday,howyouwrapthe
cu, mayaect yourbloodpressure.Review
the sections„Proper Way of Measurement“
and„TakeaMeasurement.
When
measurementfails.
Wrapthecucorrectlyandtightly.
Inateoveragainafterensuring.
Do not move your arm and body,
andkeepquiet.
Measure over again according to
correctway.
Replace all of the worn batteries
withtwonewones.
Whenthe
batteriespower
aretoolow.
DiastolicBloodPressur(mmHg)
SystolicBloodPressure(mmHg)
Green
Yellow
Red
WHO
Optimalblood
pressure
(targetvalue)
Normalbloodpressure
Normalsystolicvalue
Mildhypertension
Moderatehypertension
Severehypertension
14
16
15
17
Care and Maintenance
Specifications
Care and Maintenance
Specifications
• Keeptheunitinthestoragecasewhennotinuse.
• Cleantheunitwitha soft dry cloth. Do not useanyabrasive or volatile
cleaners.
• Neverimmersetheunitoranycomponentsinwater.
Care Maintenance
Donotcleanthebodyandcuwithnaphtha,thinner
orgasolineetc.
Store the unit in a clean and dry location. Do not
subjecttheunittoextremehotorcoldtemperature,
humidityanddirectsunlight.
Removethebatteriesiftheunitwillnotbeusedfor3
months or longer. Always replace all of the batteries
withnewonesatthesametime.
Donotwetthecuorattempttocleanthecuwith
water.
M
E
M
M
E
M
P
U
L
/
m
i
n
D
I
A
S
Y
S
B
P
2
0
4
Note:Usetheunitconsistent
with the instructions pro-
vided in this manual. Use
only authorized parts and
accessories.
M
E
M
M
E
M
P
U
L
/
m
i
n
D
I
A
S
Y
S
B
P
2
0
4
M
E
M
M
E
M
P
U
L
/
m
i
n
D
I
A
S
Y
S
B
P
2
0
4
M
E
M
M
E
M
P
U
L
/
m
i
n
D
I
A
S
Y
S
B
P
2
0
4
naphtha
thinner
gasoline
Model No.
Inflation
Power Source
Display
Rapid Air Release
Automatic Power-Off
Measuring Principle
Memory Function
Gross Weight
Measurement Localization
Cuff
Measurement
Range
Operating
Environment
Storage
Environment
Accuracy
LCD
Indication
Pressure
Temperature
KL150
AutomaticbyInternalPump
10~40°C(50~104°F)
15~90%RH(Noncondensing)
105~80kPa
-20~60°C(-4~140°F)
10~95%RH(Noncondensing)
2AAAAlkalineBatteries;D.C.3V
Pressure
OscillometricMethod
Memory60SetsMeasurementValues
Approx.100g(Batteriesnotincluded)
Pressure
SoftWristCu
Pulse
Humidity
Humidity
BarometricPressure
Temperature
LCDDigitalDisplay
AutomaticbyAirValve
In2Minutes
Pulse
Wrist
Pulse
0to299mmHg(0~39.9kPa)
3mmHg(0.4kPa)
Symbol
40to180Pulses/min
5%ofreading
3DigitsDisplayofmmHgorkPa
3DigitsDisplay
Memory/IHB/Heartbeat/LowBattery,etc.
InternalpowersupplyappliancetypeB
Electric Shock
Protection:
18
20
19
21
• Theintendeduse:Theunitisintendedtobeusedbyadultsathomeormedical
centretomeasurebloodpressureandpulserate.
• TheunitsatisestherequirementsofIEC60601-1Medicalelectricalequipment,
EN1060-1: Non-invasive sphygmomanometer, EN1060-3: Non-invasive
sphygmomanometer.
• TheunithaspassedtheEMCTest.
• Bloodpressuremeasurementsdeterminedwiththisdeviceareequivalentto
thoseobtainedbyatrainedobserverusingthecu/stethoscopeauscultatory
method, within the limits prescribed by the American National Standard,
Manual,electronic,orautomatedsphygmomanometers.
• Theriskofpatientandusercanbeloweredtoacceptablelevel.
• Substitutionofacudierentfromthatsuppliedmightresultinmeasurement
error.
• Pleasecontactusifyouneedthecircuitdiagrams,componentpartlistsetc.
• Specicationsaresubjecttochangewithoutnoticeduetoimprovementsin
performance.
• Federallawrestrictsthisdevicetosalebyorontheorderofaphysician.
• Theunitisguaranteedtobefreeofdefectsinworkmanshipandmaterialsundernormalusefor
aperiodofTwoYearsfromthedatelistedonthepurchaserecord.
• Forrepairunderthiswarranty.Ourauthorizedserviceagentmustbeadvisedofthefaultwithin
theperiodofthewarranty.Thiswarrantycoverspartsandlaboronlyundernormaloperations.
Atransportationfeeorfreightfeethatmaybeincurredwillbetheownersresponsibility.Any
defectresultingfromnaturalcauses,e.g.,ood,hurricaneetc.,isnotwithinthisguarantee.
Thisguarantydoesnotcoverdamageincurredby:useoftheunitnotinaccordancewiththe
instructions,accidentaldamage,orbeingtamperedwithorservicedbyunauthorizedservice
agents.
• Monitorsubjectedtomisuse,abuse,andneglectofthesemanualcontent,non-instructional
purposes; unauthorized repair or modications will be excluded from this warranty. This
guarantee specically excludes expendables and consumables, for example batteries. All
warrantyclaimsmustbedirectedtothedistributorresponsibleforthesaleofthedevice.The
contentofthiswarrantyissubjecttochangewithoutfurthernotice.
• Periodicalcheck:
• Sensitivemeasuringdevicesmustbecheckedfromtimetotimeforaccuracyandleakage,we
thereforerecommendthattheperformanceshouldbecheckedevery2years.
• Checkandmaintenanceandrepairfortheunit,pleasecontactthelocaldistributorfordetails
Statement Warranty Information
Kardioline Swiss Polska|ul.Kasprzaka54A|41-303DąbrowaGórnicza
Tel.(0-32)268-39-84|Fax.(0-32)268-39-83|E-mail:biuro@kardioline.pl
22
23
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7

Kardioline KL150 User manual

Category
Blood pressure units
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI