ASO Safety Solutions GF Series Assembly Instructions

Type
Assembly Instructions

The ASO Safety Solutions GF Series is a safety contact edge system designed to enhance safety measures in various industrial and commercial applications. It features precise cutting capabilities, allowing for customization to specific dimensions. The system includes water drain plugs for installations exposed to moisture, ensuring reliable performance in wet environments. With the option to choose the cable exit, users can tailor the installation to their specific needs.

The ASO Safety Solutions GF Series is a safety contact edge system designed to enhance safety measures in various industrial and commercial applications. It features precise cutting capabilities, allowing for customization to specific dimensions. The system includes water drain plugs for installations exposed to moisture, ensuring reliable performance in wet environments. With the option to choose the cable exit, users can tailor the installation to their specific needs.

Safety Contact Edge GF Series
1
Assembly Instructions
Safety-contact-edges may only be manufactured and installed by authorised persons.
1. Cutting the safety-contact-edge
The safety-contact-edge is cut 24mm shorter than the nal length dimension to allow for the length of
the end caps on each end. Make sure that the edge is cut clean and straight using the approved LOWE
cutting tool ONLY.
3. Insert lock cap
Push in the lock cap including the held plug into the hollow spaces surrounding the switching chamber
and push it tight to the cut surface of the safety-contact-edge.
4. Insert the contact plug
Insert the plug (held by the lock cap) into the electrical switching chamber of the safety-contact-edge.
Make sure that the plug is pressed in tightly until the upper notch of the plug ts closely to the lock cap
5. Put on end caps
Place the end cap onto the edge and fasten it, by pushing the xation clip into the given space until it
clicks into place. For bigger contact edges an additional xation clip is used to fasten the caps.
6. Electrical testing of the safety-contact-edge
Measure the contact edge with a multimeter. In rest position, the resistance value has to be 8,2 ±
500 Ω (7,7 - 8,7 kΩ). When edge is activated, the resistance should not exceed 500 KΩ.
7. Cutting the mounting rail
The aluminium mounting rail has to be as long as the nal dimension of the contact edge.
ASO GmbH & EasyGates exclude all liability for damage caused by incorrect installation of contact edges!
2. Preparing end caps
a) Water drain pipes
For installations in contact with water,
it is necessary to remove water drain
plugs. If the edge is to be mounted
horizontally, remove drain plugs from
both ends. If the edge is mounted
vertically, just remove the lower drain
plug.
b) Notch for the sealing lip
For TTLL & TTLA proles, remove a
notch from the end cap to allow the
sealing aps to protrude through the
cap.
c) Connection cable.
Choose desired cable exit of end cap.
Cut out the appropriate mark using a
small cutting tool.
2
a
2
b
2
c
Technical Document Ver 1.0
As of 01.03.2016
Web: www.easygatesdirect.co.uk Phone: 0845 054 50 70
E-Mail: info@easygatesdirect.co.uk Address: Easygates Ltd, Unit 16 James Scott Rd B63 2QT
  • Page 1 1

ASO Safety Solutions GF Series Assembly Instructions

Type
Assembly Instructions

The ASO Safety Solutions GF Series is a safety contact edge system designed to enhance safety measures in various industrial and commercial applications. It features precise cutting capabilities, allowing for customization to specific dimensions. The system includes water drain plugs for installations exposed to moisture, ensuring reliable performance in wet environments. With the option to choose the cable exit, users can tailor the installation to their specific needs.