Daniel Turbine Flow Meters-Mini Gas Meter Sizes 1"-3" Owner's manual

Type
Owner's manual

Daniel Turbine Flow Meters-Mini Gas Meter Sizes 1"-3" are best-in-class turbine flow meters designed to provide accurate and reliable measurement of gas flow. They are ideal for use in a wide range of applications, including custody transfer, allocation measurement, and process control. With their compact size and lightweight design, these meters are easy to install and maintain, making them a great choice for space-constrained applications.

Key features and benefits of Daniel Turbine Flow Meters-Mini Gas Meter Sizes 1"-3" include:

  • Accurate and reliable measurement of gas flow
  • Wide flow range and high turndown ratio

Daniel Turbine Flow Meters-Mini Gas Meter Sizes 1"-3" are best-in-class turbine flow meters designed to provide accurate and reliable measurement of gas flow. They are ideal for use in a wide range of applications, including custody transfer, allocation measurement, and process control. With their compact size and lightweight design, these meters are easy to install and maintain, making them a great choice for space-constrained applications.

Key features and benefits of Daniel Turbine Flow Meters-Mini Gas Meter Sizes 1"-3" include:

  • Accurate and reliable measurement of gas flow
  • Wide flow range and high turndown ratio
DANIEL MINI GAS
TURBINE METERS
1", 2", AND 3" SIZES
__________________________________________
INSTALLATION AND MAINTENANCE INSTRUCTIONS
DANIEL MEASUREMENT AND CONTROL, INC.
AN EMERSON PROCESS MANAGEMENT COMPANY
HOUSTON, TEXAS
Part Number 3-9008-018
Revision A
MAY 2005
IMPORTANT INSTRUCTIONS
Daniel Measurement and Control, Inc. (Daniel) designs, manufactures and tests its products to meet
many national and international standards. Because these instruments are sophisticated technical
products, you must properly install, use and maintain them to ensure they continue to operate within
their normal specifications. The following instructions must be adhered to and integrated into your
safety program when installing, using and maintaining Daniel products.
Read all instructions prior to installing, operating and servicing the product. If this
instruction manual is not the correct manual, call 1-713-467-6000 (24-hour response number
for both Service and Sales Support) and the requested manual will be provided. Save this
instruction manual for future reference.
If you do not understand any of the instructions, contact your Daniel representative for
clarification.
Follow all warnings, cautions and instructions marked on and supplied with the product.
Inform and educate your personnel in the proper installation, operation and maintenance of
the product.
Install your equipment as specified in the installation instructions of the appropriate
instruction manual and per applicable local and national codes. Connect all products to the
proper electrical and pressure sources.
To ensure proper performance, use qualified personnel to install, operate, update, program
and maintain the product.
When replacement parts are required, ensure that qualified people use replacement parts
specified by the manufacturer. Unauthorized parts and procedures can affect the product's
performance and place the safe operation of your process at risk. Look-alike substitutions
may result in fire, electrical hazards or improper operation.
Ensure that all equipment doors are closed and protective covers are in place, except when
maintenance is being performed by qualified persons, to prevent personal injury.
ALWAYS READ AND FOLLOW THE DANIEL MINI GAS TURBINE METERS
MANUAL AND ALL PRODUCT WARNINGS AND INSTRUCTIONS.
Use of this equipment for any purpose other than its intended purpose may result in property
damage and/or serious personal injury or death.
Before opening the flameproof enclosure in a flammable atmosphere, the electrical circuits
must be interrupted.
DANIEL MINI GAS TURBINE METERS MAY 2005
i
PREFACE
DANIEL
MINI GAS TURBINE METERS
INSTALLATION AND MAINTENANCE INSTRUCTIONS
NOTICE
DANIEL MEASUREMENT AND CONTROL, INC. ("DANIEL") SHALL NOT BE LIABLE FOR TECHNICAL OR
EDITORIAL ERRORS IN THIS MANUAL OR OMISSIONS FROM THIS MANUAL. DANIEL MAKES NO
WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT TO THIS
MANUAL AND, IN NO EVENT, SHALL DANIEL BE LIABLE FOR ANY SPECIAL OR CONSEQUENTIAL
DAMAGES INCLUDING, BUT NOT LIMITED TO, LOSS OF PRODUCTION, LOSS OF PROFITS, ETC.
PRODUCT NAMES USED HEREIN ARE FOR MANUFACTURER OR SUPPLIER IDENTIFICATION ONLY
AND MAY BE TRADEMARKS/REGISTERED TRADEMARKS OF THESE COMPANIES.
THE CONTENTS OF THIS PUBLICATION ARE PRESENTED FOR INFORMATIONAL PURPOSES ONLY, AND
WHILE EVERY EFFORT HAS BEEN MADE TO ENSURE THEIR ACCURACY, THEY ARE NOT TO BE
CONSTRUED AS WARRANTIES OR GUARANTEES, EXPRESSED OR IMPLIED, REGARDING THE
PRODUCTS OR SERVICES DESCRIBED HEREIN OR THEIR USE OR APPLICABILITY. WE RESERVE THE
RIGHT TO MODIFY OR IMPROVE THE DESIGNS OR SPECIFICATIONS OF SUCH PRODUCTS AT ANY TIME.
DANIEL DOES NOT ASSUME RESPONSIBILITY FOR THE SELECTION, USE OR MAINTENANCE OF ANY
PRODUCT. RESPONSIBILITY FOR PROPER SELECTION, USE AND MAINTENANCE OF ANY DANIEL
PRODUCT REMAINS SOLELY WITH THE PURCHASER AND END-USER.
DANIEL AND THE DANIEL LOGO ARE REGISTERED TRADEMARKS OF DANIEL INDUSTRIES, INC. THE
EMERSON LOGO IS A TRADEMARK AND SERVICE MARK OF EMERSON ELECTRIC CO.
COPYRIGHT © 2005
BY DANIEL MEASUREMENT AND CONTROL, INC.
HOUSTON, TEXAS, U.S.A.
All rights reserved. No part of this work may be reproduced or
copied in any form or by any means - graphic, electronic or
mechanical - without first receiving the written permission of
Daniel Measurement and Control, Inc., Houston, Texas, U.S.A.
MAY 2005 DANIEL MINI GAS TURBINE METERS
ii
PREFACE
WARRANTY
1. LIMITED WARRANTY: Subject to the limitations contained in Section 2 herein and except as otherwise expressly
provided herein, Daniel Measurement and Control, Inc. ("Daniel") warrants that the firmware will execute the
programming instructions provided by Daniel, and that the Goods manufactured or Services provided by Daniel will be
free from defects in materials or workmanship under normal use and care until the expiration of the applicable warranty
period. Goods are warranted for twelve (12) months from the date of initial installation or eighteen (18) months from
the date of shipment by Daniel, whichever period expires first. Consumables and Services are warranted for a period
of 90 days from the date of shipment or completion of the Services. Products purchased by Daniel from a third party for
resale to Buyer ("Resale Products") shall carry only the warranty extended by the original manufacturer. Buyer agrees
that Daniel has no liability for Resale Products beyond making a reasonable commercial effort to arrange for procurement
and shipping of the Resale Products. If Buyer discovers any warranty defects and notifies Daniel thereof in writing during
the applicable warranty period, Daniel shall, at its option, promptly correct any errors that are found by Daniel in the
firmware or Services, or repair or replace F.O.B. point of manufacture that portion of the Goods or firmware found by
Daniel to be defective, or refund the purchase price of the defective portion of the Goods/Services. All replacements or
repairs necessitated by inadequate maintenance, normal wear and usage, unsuitable power sources, unsuitable
environmental conditions, accident, misuse, improper installation, modification, repair, storage or handling, or any other
cause not the fault of Daniel are not covered by this limited warranty, and shall be at Buyer's expense. Daniel shall not
be obligated to pay any costs or charges incurred by Buyer or any other party except as may be agreed upon in writing
in advance by an authorized Daniel representative. All costs of dismantling, reinstallation and freight and the time and
expenses of Daniel's personnel for site travel and diagnosis under this warranty clause shall be borne by Buyer unless
accepted in writing by Daniel. Goods repaired and parts replaced during the warranty period shall be in warranty for the
remainder of the original warranty period or ninety (90) days, whichever is longer. This limited warranty is the only
warranty made by Daniel and can be amended only in a writing signed by an authorized representative of Daniel. Except
as otherwise expressly provided in the Agreement, THERE ARE NO REPRESENTATIONS OR WARRANTIES OF
ANY KIND, EXPRESSED OR IMPLIED, AS TO MERCHANTABILITY, FITNESS FOR PARTICULAR PURPOSE,
OR ANY OTHER MATTER WITH RESPECT TO ANY OF THE GOODS OR SERVICES. It is understood that
corrosion or erosion of materials is not covered by our guarantee.
2. LIMITATION OF REMEDY AND LIABILITY: DANIEL SHALL NOT BE LIABLE FOR DAMAGES
CAUSED BY DELAY IN PERFORMANCE. THE SOLE AND EXCLUSIVE REMEDY FOR BREACH OF
WARRANTY HEREUNDER SHALL BE LIMITED TO REPAIR, CORRECTION, REPLACEMENT OR REFUND
OF PURCHASE PRICE UNDER THE LIMITED WARRANTY CLAUSE IN SECTION 1 HEREIN. IN NO EVENT,
REGARDLESS OF THE FORM OF THE CLAIM OR CAUSE OF ACTION (WHETHER BASED IN CONTRACT,
INFRINGEMENT, NEGLIGENCE, STRICT LIABILITY, OTHER TORT OR OTHERWISE), SHALL DANIEL'S
LIABILITY TO BUYER AND/OR ITS CUSTOMERS EXCEED THE PRICE TO BUYER OF THE SPECIFIC
GOODS MANUFACTURED OR SERVICES PROVIDED BY DANIEL GIVING RISE TO THE CLAIM OR CAUSE
OF ACTION. BUYER AGREES THAT IN NO EVENT SHALL DANIEL'S LIABILITY TO BUYER AND/OR ITS
CUSTOMERS EXTEND TO INCLUDE INCIDENTAL, CONSEQUENTIAL OR PUNITIVE DAMAGES. THE
TERM "CONSEQUENTIAL DAMAGES" SHALL INCLUDE, BUT NOT BE LIMITED TO, LOSS OF
ANTICIPATED PROFITS, LOSS OF USE, LOSS OF REVENUE AND COST OF CAPITAL.
DANIEL MINI GAS TURBINE METERS MAY 2005
iii
TABLE OF CONTENTS
TABLE OF CONTENTS
1.0 SPECIFICATIONS AND DIMENSIONS................................... 1-1
1.1 1838 PREAMPLIFIER ........................................... 1-3
2.0 1" INSTALLATION AND MAINTENANCE - WAFER STYLE . . . . . . . . . . . . . . . . 2-1
3.0 2" INSTALLATION AND MAINTENANCE - WAFER STYLE . . . . . . . . . . . . . . . . 3-1
4.0 2" INSTALLATION AND MAINTENANCE - FLANGE STYLE . . . . . . . . . . . . . . . 4-1
5.0 3" INSTALLATION AND MAINTENANCE - FLANGE STYLE . . . . . . . . . . . . . . . 5-1
6.0 PERFORMANCE DATA TABLES ....................................... 6-1
7.0 DRAWINGS ......................................................... 7-1
MAY 2005 DANIEL MINI GAS TURBINE METERS
iv
TABLE OF CONTENTS
This page intentionally left blank.
DANIEL MINI GAS TURBINE METERS MAY 2005
SECTION 1
1-1
1.0 SPECIFICATIONS AND DIMENSIONS
Specifications
Temperature Limits:
Meter: Operational : -29° to +200°F
Storage: -50° to +200°F
Preamplifier: Operational : -40° to +185°F
Linearity:
Over stated range: ±1%
Limited range: ±0.5%
Repeatability at any point in stated range: ±0.1%
Overrange:
10% over maximum flow for short periods only
Figure 1-1. Unit Part Nomenclature
Materials:
Meter body: Stainless steel
Flanges: Carbon steel
Rotor: Stainless steel
Ball bearings: Stainless steel
Pickup Coil: 1500 - 1700 ohms inductance, in SS housing
Preamplifier Stand: Daniel 1838 Preamplifier
MAY 2005 DANIEL MINI GAS TURBINE METERS
SPECIFICATIONS AND DIMENSIONS
1-2
TOTALIZERS
MRT 97 Battery powered flow rate indicator/totalizer
2482 Solar powered pressure, temperature, and supercompressibility totalizer,
audit trail
2500 AC powered pressure, temperature, and supercompressibility totalizer,
audit trail
Mercury mini PT Battery powered pressure, temperature, and supercompressibility
totalizer
Mercury ECAT Battery powered pressure, temperature, and supercompressibility
totalizer, audit trail
Reynolds RECOR Battery powered pressure, temperature, and supercompressibility
totalizer, audit trail
METER CHARACTERISTICS
METER
SIZE
PULSES/ACTUAL
CUBIC FEET
PULSES/ACTUAL
CUBIC METER
FREQUENCY AT
MAX FLOW (HZ)
SPIN TIME
1" 10,400 367,250 4,333 15 sec.
2" 2,300 82,955 3,850 35 sec.
3" 625 22,063 2,425 55 sec.
DANIEL MINI GAS TURBINE METERS MAY 2005
SECTION 1
1-3
1.1 MODEL 1838 PREAMPLIFIER
Product Description
The 1838 noise-canceling preamplifier is designed for long-term use in turbine meters. On-line meter
proving is accomplished via the optional independent terminal II connection without causing
interruption or interference to the main signal transmission. Maintenance and calibration technicians
can plug into terminal block II and connect mobile readout instruments or prover electronics.
The 1838 preamplifier is available in two options:
1. Basic preamplifier: Model Number 1-504-05-500
2. Preamplifier and prover (or readout instrument) pulse output: Model Number 1-504-05-501
The Daniel 1838 preamplifier provides noise rejection features and offers output configuration
flexibility to readily interface with most instruments including PLCs. The amplifier offers normal
operation from 5 to 40 Vdc, with load-dump protection to 60 Vdc and reverse battery protection.
Brief periods of short circuited outputs can be tolerated, and normal output currents up to 250 mA
are possible. Sensitive amplifier inputs are protected from high frequency Electromagnetic
Interference (EMI) as well as static discharge, and normal operating signals up to 200 V peak to
peak. All power and output connections are protected from modest local lightning discharges.
MAY 2005 DANIEL MINI GAS TURBINE METERS
SPECIFICATIONS AND DIMENSIONS
1-4
Specifications:
Supply Voltage 5 to 40 Vdc
Supply Current < 4 mA @ 5 Vdc
< 8.5 mA @ 12 Vdc
< 17 mA @ 24 Vdc
Non-isolated
Output Voltage Vout 1 0-5 V NPN TTL
Vout 2 0-Vsupply NPN OC (current < 250 mA) or 20 mA current loop
Vout 3 0-5 V NPN, TTL (0-Vsupply) (1-504-05-501 only)
Input Sensitivity: 40 mV peak to peak
Input Single 2-wire pick-off (compatible with all Daniel pick-offs)
Frequency Range: < 10 kHz
Rise/Fall Time: < 2 microseconds
Operating Temp: - 40/ F to 185/ F
DANIEL MINI GAS TURBINE METERS MAY 2005
SECTION 1
1-5
Protection Features:
C 60 V Load Dump
C reverse battery
C output shorted to ground
C lightning protected
C inputs protected to 200 V peak to peak
C Input EMI rejection
C Thermal shutdown
Connections
Terminal I Connector: 6 terminals
Terminal II Connector: 3 terminals (optional prover or readout instrument output)
Terminal Block I
Non-Isolated Output:
1. Power, 5 to 40 Vdc
2. Common
3. Signal Out Vout 1, 0-5 V
4. Signal Out Vout 2, 0-Vsupply, OC or 20 mA current loop
5. Pickoff
6. Pickoff
Terminal Block II (optional)
Mobile Prover Hook-Up:
9. Common
10. Signal Out Vout 3
11. Not used
A pull-up resistor of 2KO should be used in 0-Vsupply powered pulse applications.
(See Figure 1-2).
MAY 2005 DANIEL MINI GAS TURBINE METERS
SPECIFICATIONS AND DIMENSIONS
1-6
Figure 1-2. Typical Preamp Configuration
DANIEL MINI GAS TURBINE METERS MAY 2005
SECTION 1
1-7
DIMENSIONS: FLANGED
Size ANSI
Class
Work
Pres A B
Bolt Circle
Diameter
Flange Bolt Holes
Approx.
Weight
No. Diameter
2 150
300
600
285
740
1,480
6 1/2
6 1/2
6 1/2
6
6 12
6 1/2
4 3/4
5
5
4
8
8
3/4
3/4
3/4
16
20
25
3 150
30
600
285
740
1.480
10
10
10
7 1/2
8 1/4
8 1/4
6
6 5/8
6 5/8
4
8
8
3/4
7/8
7/8
28
30
42
DIMENSIONS: WAFER
1 150/600 285/1480 3.5 2.62 6
2 150/600 285/1480 3.0 3.62 6
3 150/600 285/1480 6.5 5.0 N/A
Figure 1-3. Meter Dimensions
MAY 2005 DANIEL MINI GAS TURBINE METERS
SPECIFICATIONS AND DIMENSIONS
1-8
This page intentionally left blank.
DANIEL MINI GAS TURBINE METERS MAY 2005
SECTION 2
2-1
2.0 1" INSTALLATION AND MAINTENANCE - WAFER STYLE
Spin Test
A spin test is an indication of the meter bearing condition and should be carried out if there is a
reduction in meter accuracy. The test is carried out before meter disassembly by simultaneously
activating a stop watch while giving the rotor a quick spin. The time it takes the rotor to coast to a
complete stop is the “spin down time”.
A spin test is conducted on each turbine meter prior to calibration and shipment. The spin down time
will be indicated on the calibration curve supplied with each meter.
The typical spin down time for the 1" Mini Gas Turbine Meter is 15 seconds.
Meter Disassembly:
1. Remove diffuser retaining ring from downstream side of housing.
2. Pull out downstream hanger/shaft assembly.
3. Remove rotor nut.
4. The rotor assembly should now be easily removed.
5. Check rotor blades for signs of damage. Replacement rotor assemblies are available (P/N
390-01-212).
6. Remove bearings and bearing spacers.
7. Replace bearings, P/N 504-53-145 and 504-53-115, if necessary.
Meter Assembly:
1. Replace larger bearing (504-53-115) and bearing spacer on the rotor shaft.
2. Slide on rotor assembly.
3. Place upstream bearing (504-53-145) and bearing shield (rounded side out).
4. Replace and tighten rotor shaft nut.
5. Slide hanger/rotor assembly into downstream side of meter body.
6. Replace downstream retaining ring.
Installation kits for the wafer type meters are available on request.
MAY 2005 DANIEL MINI GAS TURBINE METERS
1" INSTALLATION AND MAINTENANCE - WAFER STYLE
2-2
Figure 2-1. Wafer Style 1" Mini Gas Turbine Meter
DANIEL MINI GAS TURBINE METERS MAY 2005
SECTION 3
3-1
3.0 2" INSTALLATION AND MAINTENANCE - WAFER STYLE
Spin Test
A spin test is an indication of the meter bearing condition and should be carried out if there is a
reduction in meter accuracy. The test is carried out before meter disassembly by simultaneously
activating a stop watch while giving the rotor a quick spin. The time it takes the rotor to coast to a
complete stop is the “spin down time”.
A spin test is conducted on each turbine meter prior to calibration and shipment. The spin down time
will be indicated on the calibration curve supplied with each meter.
The typical spin down time for the 2" Mini Gas Turbine Meter is 35 seconds.
Meter Disassembly:
1. Remove diffuser retaining ring from downstream side of housing.
2. Pull out downstream hanger/shaft assembly.
3. Remove rotor nut.
4. The rotor assembly should now be easily removed.
5. Check rotor blades for signs of damage. Replacement rotor assemblies are available (P/N
390-01-228).
6. Remove bearings and bearing spacers.
7. Replace bearings, P/N 504-53-145 and 504-53-115, if necessary.
Meter Assembly:
1. Replace larger bearing (504-53-115) and bearing spacer on the rotor shaft.
2. Slide on rotor assembly.
3. Place upstream bearing (504-53-145) and bearing shield (rounded side out).
4. Replace and tighten rotor shaft nut.
5. Slide hanger/rotor assembly into downstream side of meter body.
6. Replace downstream retaining ring.
Installation kits for the wafer type meters are available on request.
MAY 2005 DANIEL MINI GAS TURBINE METERS
2" INSTALLATION AND MAINTENANCE - WAFER STYLE
3-2
Figure 3-1. Wafer Style 2" Mini Gas Turbine Meter
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44

Daniel Turbine Flow Meters-Mini Gas Meter Sizes 1"-3" Owner's manual

Type
Owner's manual

Daniel Turbine Flow Meters-Mini Gas Meter Sizes 1"-3" are best-in-class turbine flow meters designed to provide accurate and reliable measurement of gas flow. They are ideal for use in a wide range of applications, including custody transfer, allocation measurement, and process control. With their compact size and lightweight design, these meters are easy to install and maintain, making them a great choice for space-constrained applications.

Key features and benefits of Daniel Turbine Flow Meters-Mini Gas Meter Sizes 1"-3" include:

  • Accurate and reliable measurement of gas flow
  • Wide flow range and high turndown ratio

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI