Marshall Air KK6 User manual

Type
User manual

This manual is also suitable for

Marshall Air KK6A is a multi-product holding unit with Lexan® doors on three sides and a digital display for precise temperature control, ideal for holding and serving food at optimal temperatures in various catering and foodservice establishments.

Marshall Air KK6A is a multi-product holding unit with Lexan® doors on three sides and a digital display for precise temperature control, ideal for holding and serving food at optimal temperatures in various catering and foodservice establishments.

OWNER'S MANUAL
MODEL KK6 - MULTI-PRODUCT HOLDING UNIT
Supplier Name: MARSHALL AIR SYSTEMS, INC.
Address: 419 Peachtree Drive South
Charlotte, NC 28217
Serial #: __________________
Date Received: ______________ ___
Date Installed: __________________
Telephone #: 704-525-6230
Toll Free #: 800-722-3474 Customer Service
Fax #: 704-525-6229
Service Referral #: 800-722-3474
Local Service: ________________ _
Local Service #: __________________
MANUFACTURER'S INTRODUCTION
The Model KK6 Series Multi-Product Holding Unit
features Marshall's own ThermoGlo™ heating
technology. Heat radiates from every square inch of the
upper and lower flat plate heating surfaces. This
eliminates the need to clean intricate calrod, wire and
reflector assemblies. This unit is equipped with Lexan®
doors on three sides to prevent drafts and provide easy
access. A precision digital display and digital "set point"
temperature controller maintain consistent product
temperature.
GENERAL SPECIFICATIONS
Height: 15 1/2"
Width: 14 3/8"
Depth: 23 5/8"
Electrical: 110/120 volts AC 605 watts
60 Hz/6 amps
Power Cord: 6 ft. 3 wire grounding type UL
rating
Weight: 45 Ibs.
Note: Illumination with (2) 40 watt
food grade coated bulbs
Accessories: (1) Stacking kit (optional)
KK6A - W/(3) Pans, Lids &
Stack Unit
KK6B - W/(3) Pans, and
Stainless Steel Grates
Approvals: UL and NSF
Shipping Dimensions:
Height: 17 1/2"
Width: 16 1/4"
Depth: 25 3/4"
Weight: 54 Ibs.
110047KK6 RV082799
Copyright © 1999 Marshall Air Systems, Inc.
All Rights Reserved.
MODEL KK6 - MULTI-PRODUCT HOLDING UNIT
TABLE OF CONTENTS
INSTALLATION............................................................................................................... 1
DAILY CHECKLIST AND CLEANING GUIDE............................................................ 1 -2
MONTHLY MAINTENANCE............................................................................................2
TROUBLESHOOTING CHART.......................................................................................3
REPLACEMENT PARTS LIST AND ILLUSTRATION..............................................…4-5
COMPLETE STACKING KIT P/N 110057......................................................................6
THERMOGLO™& HEATED HOLDING CABINET LIMITED WARRANTY................... 7
THERMOGLO™ & HEATED HOLDING CABINET WARRANTY RETURN
PROCEDURES............................................................................................................. 8
ILLUSTRATIONS
REPLACEMENT PARTS ILLUSTRATION.........................................FIGURE 1, PAGE 5
WIRING SCHEMATIC (KK6, KK6A, KK6B) 120V....................................... DWG 112620
110047KK6 RV082799
Copyright © 1999 Marshall Air Systems, Inc.
All Rights Reserved
MODEL KK6 - MULTI-PRODUCT HOLDING UNIT
INSTALLATION
PRE-INSTALLATION
The Multi-Product Holding Unit is packaged to minimize the risk of shipping damage. Immediately upon receipt,
make certain to inspect the unit for damage. FILE ALL CLAIMS WITH THE FREIGHT CARRIER.
FINAL INSTALLATION
1. Unpack unit and remove all protective paper or plastic covering from metal parts and Lexan® doors. NOTE: THE
SCREWS HOLDING THE LEXAN® DOORS ARE TO BE LOOSE TO ALLOW FOR HEAT EXPANSION.
2. Place holding unit on stable base. Make sure louvers at back of unit, next to power cord, are not blocked.
3. If unit is to be stacked, see Stacking Kit Installation Instructions, Page 5
4. Plug unit into an AC 120V receptacle.
DAILY CHECKLIST AND CLEANING GUIDE
TO USE THE MULTI-PRODUCT HOLDING UNIT
1. Turn on the power switch. The unit is ready to use after a 20-minute preheat period.
2. The temperature controller on the front of the unit is factory set for 175°F. With the control "ON", the
actual temperature is displayed. The range of set points available is from 140°F to 200°F.
CHANGING THE SET POINT
CAUTION: PRESS ONLY WITH SOFT PART OF FINGER - DO NOT PUSH WITH SHARP OBJECT.
FOR UNITS WITH SERIAL NO. 89021859 AND HIGHER:
The faceplate of the control is either black or gray. The set point may be verified or changed as follows:
IF BLACK: depress the set button to view the set point. To change set point, use Up/Down arrow to select new
set point while holding set button down.
IF GRAY: depress the set button and RELEASE to view set point. To change set point, push "set" and within
three seconds, use Up/Down arrow to select new set point.
FOR UNITS WITH SERIAL NO. 89021858 AND LOWER:
The "set point" can be checked by depressing the set button on the controller. The setting is adjustable and
may be changed by turning the small screw on the face of the controller while holding the red button down.
When the button is released the actual temperature is displayed.
110047KK6 RV082799
Copyright 1999 Marshall Air Systems, Inc.
All Rights Reserved
1
MODEL KK6 - MULTI-PRODUCT HOLDING UNIT
3. If pans are to be used, place them in unit.
4. Wait one hour to stabilize the temperature.
5. Check the surface temperature on the unit digital display to see if it is 175°F ± 10°F.
6. If the digital display temperature is outside of the specified range, remove the pans, wait two
minutes, then check the actual surface temperature 6" from the front in the center. This should be
185°F ± 10°F. Note that the surface temperature is higher when the pans are removed.
CLEANING CHECKLIST
1. Turn off the unit and allow it to cool for 20 minutes.
2. Pans, lids and wire grates should be removed, washed in mild multi-purpose detergent, rinsed and
sanitized.
3. Clean unit and base with a damp cloth or non-abrasive cleaner. DO NOT IMMERSE UNIT IN
WATER! DO NOT USE CAUSTIC CLEANING SOLUTIONS!
4. Allow sufficient drying time before attempting to use.
MONTHLY MAINTENANCE
1. Follow the daily cleaning checklist; there are no periodic adjustments.
2. Check the condition of the two light bulbs located under the top cover. If these fail, do the following:
A. Unplug the unit.
B. Remove the bulb(s) by carefully unscrewing them from their sockets.
C. Replace the bulb(s) with a manufacturer's approved replacement part. (See parts list page 4.)
3. Check airflow through unit by feeling air at louvers on back of unit or checking for air draw at slots on
front on each side of temperature controller. If no movement felt, cooling fan is not working. Call a
qualified service technician to make repair.
4. Observe condition of Lexan® side panels. If excessively scratched and/or cracked, replace.
5. Inspect condition of cord/plug. If damaged, have it replaced.
110047KK6 RV082799
Copyright 1999 Marshall Air Systems, Inc.
All Rights Reserved
2
MODEL KK6 - MULTI-PRODUCT HOLDING UNIT
TROUBLE SHOOTING CHART
** DISASSEMBLING HEATER VOIDS WARRANTY **
Identify problem in the left-hand column and look for probable cause and solution in right-hand column. Probable
causes listed in the order they are most likely to happen. This sequence should be used to isolate the problem.
PROBLEM PROBABLE CAUSE SOLUTION
1. No Light/No Heat Unplugged Circuit breaker is tripped
Plug in Reset breaker - call
electrician if tripped twice
Cord/plug defective Replace cord/plug
2. No Light/With Heat Light bulbs burned out Unplug unit and replace bulbs
3. Light/No Heat Defective heating unit assembly Replace heating unit assembly
4. No Heat at Base Defective wiring/temperature controller
Replace Wiring/temperature
controller
5. Low Product Temperature Set point too low Excessive air draft Reset to 175°F Move unit
6. Heat at Base too High Defective temperature controller
Replace defective temperature
controller
7. Heat at Base too Low
Defective sensor, temperature controller
or heating element
Replace sensor, temperature
controller or heating element
8. Display reads "EEE" Disconnected or defective sensor Reconnect or replace sensor
110047KK6 RV082799
Copyright © 1999 Marshall Air Systems, Inc.
All Rights Reserved
3
MODEL KK6 - MULTI-PRODUCT HOLDING UNIT
REPLACEMENT PARTS LIST (See Figure 1 for Diagram)
ITEM PART# DESCRIPTION
1 501867 Rubber Feet
2 114542 Temperature Controller *See Note)
3 502248 Transformer 120V to 12V
4 501864 Rocker Switch
5 110042 Fan
6
501882
501957
Lower Heating Element 120V
Lower Heating Element 220V
7 502169 Sensor
8 111894 Bumper Pin Replacement Set (see Page 6)
9 109872 ThermoGlo™
10 501865 Lampholder
11 502239 Coated Bulb
12
119892
109797
Optional Right Lexan® Side Panel With Stiffener Angle (KK6C Model)
Lexan® Side Panel (no stiffener angle)
13 501069 Hinge
14
119893
109798
Optional Lexan® Rear Panel With Stiffener Angle (KK6C Model)
Lexan® Rear Panel (no stiffener angle)
15 501193 Cord Strain Relief
16 109868 6 Ft. Cord w/Plug
17 109845 Lexan® panel, front (Optional)
18 501930 Hinge screws, 10-32 x 1/2"
19 501355 Nut 10-32
20
120918
109797
Optional Left Lexan® Side Panel With Stiffener Angle (KK6C Model)
Lexan® Side Panel (no stiffener angle)
21 109782 Platen Surface
22 117038 Temperature Controller Conversion (See Note Below)
Not Shown 503413 Kit, Temp. Control Faceplate REF:132574 Centigrade to Fahrenheit
Note: If Temperature Controller Face looks like controller "A", order #114542. (See Figure 1)
If Temperature Controller Face looks like controller "B", order #117038. (See Figure 1)
110047KK6 RV082799
Copyright © 1999 Marshall Air Systems, Inc.
All Rights Reserved
4
MODEL KK6 - MULTI-PRODUCT HOLDING UNIT
REPLACEMENT PARTS ILLUSTRATION
110047KK6 RV082799
Copyright © 1999 Marshall Air Systems, Inc.
All Rights Reserved
FIGURE
1
REPLACEMENT
PARTS
ILLUSTRATION
5
MODEL KK6 - MULTI-PRODUCT HOLDING UNIT
STACKING KIT INSTALLATION INSTRUCTIONS
1. When mounting units, be sure the rubber feet of the top unit are securely placed in the notches on the
brackets.
2. After stacking the two units, remove the two screws located on the rear side.
3. Mount the cord clamps and route the cord along the rear leg, as shown.
110047KK6 RV082799
Copyright1999 Marshall Air Systems, Inc.
All Rights Reserved
6
MODEL KK6 - MULTI-PRODUCT HOLDING UNIT
THERMOGLO™ AND HEATED HOLDING CABINET LIMITED WARRANTY
MARSHALL AIR SYSTEMS, INC., ("Marshall") warrants to the first purchaser ("Purchaser") all new equipment of its manufacture to be
free of defects in material and factory workmanship for a period of one year from date of shipment provided that (i) the equipment is installed
in the Continental United States, Canada or Hawaii and operated according to the Owner's Manual while located at the original address of
installation, (ii) the warranty registration card has been completed and returned to the factory within fifteen (15) days after installation.
Marshall's obligation under this warranty is limited to the repair or replacement at its option of any defective part. It is understood that
Marshall's obligation with respect to equipment located outside the Continental United States, Canada or Hawaii is limited to replacement
parts only.
Because Marshall does not and cannot control Purchaser's installation, use, and maintenance of equipment manufactured by Marshall,
this warranty DOES NOT COVER:
1. Any equipment calibration.
2. Switches.
3. Plugs and cords.
4. Blown fuses or bulbs.
5. Any component disassembled in the field or that has broken seals.
6. Any replacement parts used on the equipment which are not purchased from Marshall.
7. Accessory components not installed and/or manufactured by Marshall.
8. Water or grease accumulation, which will cause electrical failures.
9. Labor, except that provided at Marshall's factory.
10. Damage due to improper or lack of cleaning, abuse and/or service.
SHIPPING DAMAGE must be reported to the carrier and is not covered under this warranty. Marshall will not be liable for damage as a
result of improper installation, misuse, abuse, alteration of original design, incorrect voltage, unauthorized service, breakage of fragile items,
or any other damage caused by an act out of Marshall's control.
The effect of corrosion, fire, and normal wear on the equipment or component parts is not covered by this warranty. This warranty does
not cover cooking performance, smoke capture or holding temperatures which is a function of food types, textures, temperatures, equipment
line ups and other variables chosen by the Purchaser and over which Marshall has no control. This warranty does not apply to damage
caused by accident or to damage caused by the negligence of Purchaser or the employees of Purchaser or to damage caused by lightning
generated electrical current or any other Act of God whatsoever. This warranty does not apply to any equipment bearing a serial number
which has been tampered with or altered. Marshall reserves the right to accept or reject any such claim in whole or in part. Marshall will not
accept the return of any product without prior written approval from Marshall, and all such approved returns shall be made at Purchaser's
sole expense.
THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE IMPLIED WARRANTY OF
MERCHANTABILITY AND THE IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, OR PATENT OR OTHER
INTELLECTUAL PROPERTY RIGHT INFRINGEMENT, AND EXCEPT FOR THE EXPRESS WARRANTY CONTAINED HEREIN, THE
EQUIPMENT IS SOLD "AS IS." REMEDIES UNDER THIS WARRANTY AND UNDER ANY WARRANTY THAT MAY SURVIVE THE
DISCLAIMER OF WARRANTIES ARE LIMITED EXCLUSIVELY TO THOSE REMEDIES DESCRIBED ABOVE. NO OTHER REMEDY IS
AVAILABLE UNDER THIS WARRANTY OR ANY OTHER WARRANTY. NEITHER THIS WARRANTY NOR ANY OTHER WARRANTY
COVERS, AND MARSHALL WILL NOT BE RESPONSIBLE FOR, ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES, INCLUDING
BUT NOT LIMITED TO THE COST OF DISASSEMBLY AND SHIPMENT OF THE EQUIPMENT, PRODUCTION OR PRODUCT LOSSES,
INJURY TO OTHER PROPERTY, OR LOST PROFITS RESULTING FROM THE USE OF OR INABILITY TO USE THE PRODUCTS OR
FROM THE PRODUCTS BEING INCORPORATED IN OR BECOMING A COMPONENT OF ANY OTHER PRODUCT OR GOODS, OR
OTHER LOSSES. WHERE, DUE TO OPERATION OF LAW, CONSEQUENTIAL AND INCIDENTAL DAMAGES CANNOT BE
EXCLUDED, THEY ARE EXPRESSLY LIMITED IN AMOUNT TO THE PURCHASE PRICE OF THE EQUIPMENT.
FOR INTERNATIONAL INSTALLATIONS - PLEASE CONTACT YOUR LOCAL MARSHALL AIR
SYSTEMS RECOGNIZED DISTRIBUTOR.
110047KK6 RV082799
Copyright 1999 Marshall Air Systems, Inc.
All Rights Reserved
7
MODEL KK6 - MULTI-PRODUCT HOLDING UNIT
THERMOGLO™AND HEATED HOLDING CABINET WARRANTY
RETURN PROCEDURES
I. RETURN GOODS AUTHORIZATION FOR PARTS:
For prompt warranty parts replacement and RGA processing, please call Marshall's Customer
Service Department at 800-722-3474 or 704-525-6230 for assistance. In all cases, a Return Goods
Authorization (RGA) number must be issued by Marshall Air Systems, Inc. Unauthorized returns will
not be processed.
Option #1: Purchaser to return part(s) prepaid to Factory, Marshall to repair or replace at own
expense if defective, and ship part(s) back to Purchaser prepaid.
Option #2: Marshall to furnish replacement part(s) freight prepaid with or without requesting
return of the defective part(s).
Option #3: Purchaser may obtain replacement part(s) from recognized service agency.
II. NON-WARRANTY RETURNS:
All items returned for customer cancellations are subject to a 20% restocking fee. In the event of an
error by Marshall Air Systems, Inc., a Returned Goods Authorization will be issued for full credit.
Custom fabricated parts are not returnable.
FOR INTERNATIONAL INSTALLATIONS -- PLEASE CONTACT YOUR LOCAL
MARSHALL AIR SYSTEMS RECOGNIZED DISTRIBUTOR.
110047KK6 RV082799
Copyright © 1999 Marshall Air Systems. Inc.
All Rights Reserved
8
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11

Marshall Air KK6 User manual

Type
User manual
This manual is also suitable for

Marshall Air KK6A is a multi-product holding unit with Lexan® doors on three sides and a digital display for precise temperature control, ideal for holding and serving food at optimal temperatures in various catering and foodservice establishments.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI