1171250101

Brennenstuhl 1171250101 Datasheet

  • Hello! I am an AI chatbot trained to assist you with the Brennenstuhl 1171250101 Datasheet. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
2
1
2
3
5-10 mm
L N
5-10 mm
L N
BA_Chip_Leuchte_Stationaer_130701.indd 2 01.07.13 10:56
8
D
Operating Instructions
Chip LED Light
Please note: Please read these instructions carefully prior to mounting
the light and store them in a safe location afterwards!
SPECIFICATIONS
Protection class: I
Nominal voltage: 220 – 240V~ 50Hz
Model: Output: Type of Motion Protective cover
protec- detector: dimensions:
tion:
L CN 110 IP65 10W (1 x 10W) IP65 no 110.5 x 83 x 4mm
L CN 110 PIR IP44 10W (1 x 10W) IP44 yes 110.5 x 83 x 4mm
L CN 130 IP65 30W (1 x 30W) IP65 no 220.5 x 180.5 x 4mm
L CN 130 PIR IP44 30W (1 x 30W) IP44 yes 220.5 x 180.5 x 4mm
L CN 150 IP65 50W (1 x 50W) IP65 no 281.5 x 231 x 4mm
L CN 150 PIR IP44 50W (1 x 50W) IP44 yes 281.5 x 231 x 4mm
L CN 180 IP65 80W (1 x 80W) IP65 no 303.5 x 225.5 x 5mm
The heavy-duty LED light is suitable for indoor and outdoor lighting
applications and is designed for permanent installation. Do not use
this light for any other purposes.
BA_Chip_Leuchte_Stationaer_130701.indd 8 01.07.13 10:56
9
D
Chip LED Light Operating Instructions
SAFETY NOTES
1. The light must be installed and serviced by a qualied technician.
2. Always turn o the power supply before installing or servicing the
light.
3. The light must be properly earthed.
4. Do not use this light without properly attached gaskets!
5. LED lights are extremely bright! Avoid looking straight into an LED
light beam, as doing so could result in irreversible eye damage.
6. Damaged protective covers must be replaced with an original
Brennenstuhl protective cover before the light can be used again.
7. If the mains supply cable of the light is damaged it must be replaced
by a qualied technician in order to avoid risks.
MOUNTING AND CONNECTION TO THE POWER SUPPLY
1. Do not attach the light to a surface that is subject to vibrations.
2. Mounting position: If possible the light should be mounted using
the wall bracket. Lights with a motion detector must be mounted
as shown in Fig. 1.
3. Mark the position of the bore-holes that are needed to attach the
wall bracket and drill the required holes in the wall. Attach the
bracket to the wall using suitable screws.
4. Open the light’s terminal box.
BA_Chip_Leuchte_Stationaer_130701.indd 9 01.07.13 10:56
10
D
Operating Instructions Chip LED Light
5. Guide the connecting cable through the cable gland and connect
it to the light’s lustre terminal as shown in Fig. 2 (left image shows
10W version, right image shows 30W version and higher. N = blue
cable, earthing symbol = green / yellow cable, L = brown cable).
6. Make sure the cable is securely fastened in the cable gland.
7. Replace the cover of the terminal box. Make sure the gasket is
seated correctly.
8. Fasten the light to the wall bracket using the screws and nuts
included with the package. Set the light to the desired position
and tighten the screws.
DESCRIPTION OF OPERATION
(For Versions with a Motion Detector)
The light is equipped with an infrared sensor. It turns on automatically
whenever the sensor detects movement in its vicinity
Try not to aim the motion detector in the direction of swimming pools,
heater vents, air conditioners or objects which are subject to large
variations in temperature. Avoid pointing the motion detector at trees
or shrubs and at areas where pets like to move about.
Make sure when mounting the light that the motion detector is most
sensitive to things that move through its detection range from side
to side and least sensitive to things that move straight at the device.
ADJUSTING THE MOTION DETECTOR
There are three knobs on the underside of the light (see Fig. 3).
Setting the time (TIME):
Use the TIME knob to set how long the light remains on after the last
movement (between 10 seconds and 4minutes). Turn the TIME knob
clockwise to increase the time span.
BA_Chip_Leuchte_Stationaer_130701.indd 10 01.07.13 10:56
11
D
Chip LED Light Operating Instructions
Sensitivity (SENS):
This knob can be used to adjust the sensitivity of the sensor. Turn the
SENS knob clockwise to increase sensitivity.
Light Setting (LUX):
The LUX setting determines how dark it must be before the sensor
turns on the light. The sun symbol () shows that the sensor is active
during the day and at night. If the knob is set to moon (), the sensor
only works at night. To adjust the sensor, wait until the desired level
of ambient light has been reached. Turn the knob all the way to the
moon symbol (), then turn the knob slowly towards the sun symbol
() until the light turns on if movement is detected.
The light will thereafter turn on automatically at the preset level of
darkness whenever a movement is detected.
Motion detector: passive infrared sensor
Detection range: up to 12m / up to 180 ° (horizontal)
Time setting: approx. 10 sec–4min
MAINTENANCE AND CLEANING
All maintenance work must be carried out by a qualied electrician.
PLEASE NOTE: The LED light does not contain parts that need servicing.
The LED light source cannot be replaced. If necessary, replace the
entire light.
Do not use solvents, corrosive cleaners or the like. Use a dry or slightly
moist cloth for cleaning ONLY.
BA_Chip_Leuchte_Stationaer_130701.indd 11 01.07.13 10:56
12
D
Operating Instructions Chip LED Light
Dispose of electrical devices in an environmentally
responsible manner!
Do not dispose of electrical devices with household
rubbish!
In accordance with Directive 2012/19/EU on waste electrical
and electronic equipment, used electrical equipment
must be collected separately and reused or recycled in an
environmentally responsible manner.
Please contact your local authorities for available disposal
options for your worn-out device.
Addresses
Hugo Brennenstuhl GmbH & Co. KG
Seestraße 1 3 ∙ 72074 Tübingen ∙ Germany
H. Brennenstuhl S.A.S.
F-67460 Souelweyersheim
lectra-t ag
Blegistrasse 13 ∙ CH-6340 Baar
www.brennenstuhl.com
BA_Chip_Leuchte_Stationaer_130701.indd 12 01.07.13 10:56
BA_Chip_Leuchte_Stationaer_130701.indd 103 01.07.13 10:56
Hugo Brennenstuhl GmbH & Co. KG
Seestraße 1 3 · D-72074 Tübingen · Germany
H. Brennenstuhl S.A.S.
F-67460 Souelweyersheim
lectra-t ag
Blegistrasse 13 · CH-6340 Baar
www.brennenstuhl.com
0472362/613
BA_Chip_Leuchte_Stationaer_130701.indd 104 01.07.13 10:56
/