Generac 9 kW G0070301 User manual

Type
User manual
8
A
7 6 5 4 3 2 1
B
C
D
A
B
C
D
8 7 6 5 4 3 1
DRAWING CREATED FROM PRO/ENGINEER
3D FILE. ECO MODIFICATION TO BE
APPLIED TO SOLID MODEL ONLY.
635
[25.0]
733
[28.8]
648
[25.5]
218
[8.6]
345
[13.6]
COMPACTED SOIL
GRAVEL PAD/
127 [5.0]
521
[20.5]
197
[7.7]
849
[33.4]
68
[2.7]
393
[15.5]
679
[26.8]
768
[30.2]
267
[10.5]
356
[14.0]
1218
[48.0]
1232
[48.5]
914 [36.0]
MINIMUM OPEN AREA
457 [18.0]
MINIMUM OPEN AREA
914 [36.0]
MINIMUM OPEN AREA
914 [36.0]
MINIMUM OPEN AREA
SH
1/1
REV
B
WINDCHILL VERSION
B.15
FIRST USE: G0070432
ELECTRONICALLY APPROVED
INSIDE WINDCHILL
TITLE
INSTALL HSB GENERATOR WM 60HZ
ISSUE DATE: 12/19/16
SIZE CAGE NO DWG NO
10000010258
REV
B
N/A
B
SCALE
NTS
WT-KG N/A SHEET
1 of 1
AIR OUTLET
AIR INTAKE
AIR INTAKE
TOP VIEW
ALL DIMENSIONS IN:
MILLIMETERS [INCHES]
LEFT SIDE VIEW
RIGHT SIDE VIEW
REAR VIEW
RIGHT VIEW
INTAKE PANEL REMOVED
FUEL INLET : 1/2" NPT (9-11kW)
: 3/4" NPT (16-22kW)
REQUIRED FUEL PRESSURE : NATURAL GAS : 3.5-7" WATER COLUMN
LIQUID PROPANE (VAPOR) : 10-12" WATER COLUMN
MAIN AC/CONTROL WIRING HOLE FOR 3/4" CONDUIT
MAIN AC/CONTROL WIRING HOLE FOR 1 1/4" CONDUIT
"DO NOT LIFT BY ROOF"
LIFTING HOLES 4 CORNERS: 30 [ 1.2]
- MUST BE LIFTED WITH STEEL RODS
- RECOMMENDED LIFTING ROD SIZE: 25 [ 1.0]
FRONT VIEW
BOLTS RECOMMENDED
10 [3/8] DIA. MASONRY ANCHOR
HOLE (3) PLACES,
16 [5/8] DIA. CLEARANCE
A CONCRETE PAD
OPTIONAL MOUNTING TO
HOLE LOCATIONS FOR
FRONT OF UNIT
MOUNTING TO CONCRETE PAD
TRANSFER SWITCH
(IF SUPPLIED)
WIRELESS MODULE
AUXILIARY SHUTDOWN SWITCH
-REMOVE FACTORY PLUGS AND DISCARD
-CLOSE ANY UNUSED HOLE WITH A NEMA
3R RATED PLUG (FIELD SUPPLIED)
(
)
  • Page 1 1

Generac 9 kW G0070301 User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI