INSTALLATION MANUAL
IP INTERFACE MODULE SX-200IP
Thank you for purchasing TOA’s IP Interface Module.
Please carefully follow the instructions in this manual to ensure long, trouble-free use of your equipment.
1. SAFETY PRECAUTIONS
• Beforeinstallation oruse,besuretocarefully readalltheinstructions inthis section forcorrect andsafe
operation.
• Besuretofollowalltheprecautionaryinstructionsinthissection,whichcontainimportantwarningsand/or
cautions regarding safety.
• Afterreading,keepthismanualhandyforfuturereference.
2. GENERAL DESCRIPTION
The SX-200IP, designed to be installed in the SX-2100AI Audio input unit of the SX-2000 series, is an Interface
module for connection to the N-8000 series.
ByconnectingtheSX-200IPtoanetwork(LANorWAN),pagingannouncementscanbemadetotheSX-2000
systemusingtheN-8000seriesstation(s)(N-8600MSandN-8610RM)employingthepacketaudiotechnology.
Each function is set by the dedicated setting software on a PC.
3. FEATURES
• Upto8SX-200IPscanbeusedperSX-2000System.
• Pagingannouncementscanbemadetoupto8SX-2000systemsusingtheSX-200IPs.
4. SPECIFICATIONS
Network Section NetworkI/F: 10BASE-T/100BASE-TX(Automatic-Negotiation)
Networkprotocol: TCP/IP,UDP,HTTP,RTP,ARP,ICMP,IGMP
Connector: RJ45connector forLAN
Voicesamplingfrequency: 16kHz,8kHz(controllableonthesoftware)
48kHzsamplerateisusedforSX-2000systemonly.
Quantifyingbitnumber: 16bits
Voiceencodingmethod: Sub-bandADPCM,Cryptosystem
Voicepacketlossrecovery: Silenceinsertion
Audiodelaytime: 80ms,320ms(controllableonthesoftware)
Indicator Operationindicator(RUN)
Operating Temperature 0to40ºC
OperatingHumidity 90%RHorless(nocondensation)
Finish Panel:Pre-coatedsteelplate,black,30%gloss
Dimensions 35(w)x119.5(h)x178.4(d)mm
Weight 150g
Note: Thedesignandspecicationsaresubjecttochangewithoutnoticeforimprovement.
Indicatesapotentiallyhazardoussituationwhich,
if mishandled, could result in death or serious
personalinjury.
WARNING
• Do not expose the unit to rain or an environment
where it may be splashed by water or other liquids,
asdoingsomayresultinreorelectricshock.
• Should the following irregularity be found during
use, immediately turn off the power supply to the
SX-2100AI Audio Input Unit where the SX-200IP
is installed and contact your nearest TOA dealer.
Make no further attempt to operate the unit in this
conditionasthismaycausereorelectricshock.
· If you detect smoke or a strange smell coming
from the unit
· Ifwaterormetallicobjectgetsonthecircuitboard
· If the unit falls or breaks
· Ifitismalfunctioning(notonesounds.)
5. MODULE INSTALLATION
Notes
• MakesurethatthepowerisswitchedOFFbeforeattachingordetachingSX-200IPs.
• Toavoidfailuresduetostaticelectricity,donottouchthepartsontheSX-200IPcircuitboard.
• EnsurethattheSX-200IPisinstalledandsecuredwithscrewsinthecorrectposition.
• Twosilverslottedscrewsattheleftandrightsidesofthefrontpanelarehandlesusedformoduledetachment.
Never rotate them because they do not function as screws.
Step 1. Removetheblankpanelattached
to the SX-2100AI’s slot.
Step 2. Mount the SX-200IP.
Insert the SX-200IP and x it in
place using the screws (Machine
screwsM3x6)removedinStep1.
2
1
Blank panel
SX-2100AI
Machine screw M3 x 6
(screw removed in Step 1)
Handle
SX-200IP
6. CONNECTION
Note
UsableLANcableisaSTPCategory5orgreaterstraightthrough
cable only.
AUTPcablecannotbeused.
RJ-45 connector
LAN cable
SX-200IP
To network
LINK/ACT 10/100M
LAN
RESET RUN
IP INTERFACE MODULE
model SX-200IP
FOR SX-2000 SERIES ONLY
7. NOTES ON SETTING
It is necessary to perform SX-200IP setting using both the SX-2000 Setting software and N-8000 Setting
software.
7.1. SX-2000 Setting Software
TheSX-200IPisrecognizedasthe“D-922E/F”intheSX-2000system.SettheSX-200IPasthe“D-922E/F”on
theSX-2000Settingsoftware.Forthesettings,readtheSX-2000Softwareinstructionmanual.
7.2. N-8000 Setting Software
Forthesettings,readchapter5oftheN-8000seriesinstructionmanual.
URL:http://www.toa.jp/
133-22-400-10
Traceability Information for Europe
Manufacturer:
TOA Corporation
7-2-1,Minatojima-Nakamachi,Chuo-ku,Kobe,Hyogo,Japan
Authorizedrepresentative:
TOAElectronicsEuropeGmbH
Suederstrasse282,20537Hamburg,Germany
8. SX-200IP OPERATING REQUIREMENTS IN THE SX-2000 SYSTEM
•TheSX-2000SettingSoftwareusedforSX-2000systemsettingsshouldbeVersion3.10orlater.
•TheSX-2000systemcomponentsshouldbeofthefollowingrmwareversions.
SX-2000SM, SX-2100AI, SX-2000AO, SX-2100AO Version3.10orlater
SX-2000CI, SX-2000CO Version 2.01 or later
/