SAFETY INSTRUCTIONS
ImportantSafetyInstructionsand
Warnings
Readthisentiremanualbefore
proceedingtoinstallthecooler.
Failuretoobservethesewarnings
andinstructionswillvoid
manufacturer'swarrantiesandwill
dischargethemanufacturerofall
liability.
!
ALWAYSdisconnectthecooler
fromthepowersupplybefore
commencingmaintenance
procedures.
AvoidDangerousSituations:
Protectthecoolerfromall
sourcesofignitionbecause
polymersandcoolingpadswill
burn.
WARNING: Thewarningsandsafety
instructionsinthismanualmustbe
followedtoreducetheriskoffire,
electricshockorinjury,andtoprovide
reasonablesafetyandefficiencyin
usingthisEvaporative AirCooler. The
operatorisresponsibleforfollowingthe
warningsandinstructionsinthis
manualandonthecooler.
Duringmaintenanceprocedures,
NEVERuseanakedflameforany
inspectionorcleaningpurposeas
afirecouldbecausedbyaflame
comingintocontactwiththecooler
materials.
NEVERuseawaterhosetosquirtthe
interiorofthecoolerforcleaningas
residualwatercoulddamageelectrical
componentsandcreatetheriskoffire
and/orelectricshocktotheuserafter
re-assembly.
CAUTION
Thisapplianceisnotintendedfor
usebypersons(includingchildren)
withreducedphysical,sensoryor
mentalcapabilities,orlackof
experienceandknowledge,unless
theyhavebeengivensupervisionor
instructionconcerninguseofthe
appliancebyapersonresponsible
fortheirsafety.
Safety
WATERPUMP
Undernocircumstancesare
"PowerClean"styletimedpumps
tobeusedinanyBreezair
evaporativeaircooler.
Failuretofollowthis
instructionwillVOID ALL
WARRANTY andmaycreatesevere
riskofelectricshockandfire!
FAN MOTOR
Failuretofollowthisinstructionwill
VOID ALL WARRANTY andmay
createsevereriskofelectricshock
andfire!
CIRCUITBREAKERPROTECTION
Thewaterpumpissuppliedwiththis
coolerandisfactoryfittedintoits
correctlocation.
Ensurethatitisproperlysecuredand
uprightasintended.
Thereisnoneedtoadjustthewater
flowsincethecoolerisdesignedto
operatewithmaximumcoolingatlow
airvelocities.
Factoryauthorizedpumpsarefitted
withthermaloverloadprotection.
Waterpumpsmayseizeupand
overheat,creatingafirerisk.Pumps
thathavethermaloverloadprotection
aredesignedtoshutoffthepumpif
themotoroverheats.
Seeley"Tornado"pump(partno.
095851)
Useofthese
devicesoranyothernon-approved
devicewillcauseseriousdamageto
thespecialsafetycircuitsofthis
cooler.
Thiscoolerissuppliedwithafan
motormadebythecooler
manufacturer.USEONLY THE
AUTHORIZEDFANMOTOR
SUPPLIED.
Seeley Variable Speed motors:
550W (3/4HP) motorpart # 095118
750W (1HP) motor part # 095125
Thefanmotorisequippedwithinbuilt
overheatingprotectionthatwillreset
automaticallyoncool-downtoasafe
temperature. Thismaytakeupto45
minutes.
Thiscoolerisfittedwithcircuitbreaker
protectionforthefanmotorandpump.
Waterpumpreplacement
Factory Authorizedwaterpump
“PowerClean"StyleTimedPumps
FactoryAuthorized Fan Motor
INSTALLATION,REPAIR AND
OPERATION
!
!
!
!
!
!
!
!
!
!
!
!
!
!
Disconnectelectricalpoweratthefuseor
circuitbreakerboxbeforeinstallation
commences. ALWAYSturnOFFtheisolating
switch(disconnect)locatedontheelectronic
moduleinsidethecoolerBEFORE
commencinganymaintenanceprocedures
Keepchildren,bystandersandanimalsat
asafedistance,aminimumof30ft(10m)
awayfromworkingareas.
Dresssafely.Wearnon-skidshoeswhen
workingathighlevelsandroofs.Donot
wearlooseclothingorpersonalaccessories
whileinstallingorservicingtheaircooleras
theymaybecomecaughtinmovingparts.
Keeploosehair,looseclothing,fingers
andallotherpartsofthebodyawayfrom
openingsandmovingparts.
Checkthecoolerforworn,loose,missing,
ordamagedpartsbeforeoperation.
Ifyouworkwithpowertools,wear
protectiveeyewearandgloves.
Takecarewhenliftingorraisingtheair
coolertoitsfinallocation.Usesafe
equipmentandneverattempttoliftthe
cooleralone. Alwayshaveassistance.
Otherwiseyoumightdamagethecooleror
thebuildingorinjureyourself.
GroundFaultCircuitInterrupter(GFCI)
protectionshouldbeprovidedonthecircuit
supplyingthisaircooler.Receptaclesare
availablewithbuilt-inGFCIprotection.
Aircoolersinstalledonroofsmustnot
havethewastewaterdirectedontotheroof
asstainswilloccur.Connectthecoolerdrain
outlettoagutterordrainpipeusinga
suitablehose.
Alwaysusethecorrecttools.
thepackagingplasticonthis
coolercanbeasafetyhazard.Disposeof
carefully.
Neverdrillholesinthepanorwallsofthe
cooler.
Avoiddangeroussituations.Donotuse
thecoolerinthepresenceofflammable
liquidsorgassestoavoidcreatingfireor
explosion. ThisaircoolerisNOT flame
retardant. A firemayresultfromcontactwith
aflameorfromanelectricalshort.
Useofwrongreplacementpartscreates
riskofsevereelectricshockandfirewhich
mayresultinseriouspropertydamage,
personalinjuryordeath.
Useonlythepowersupplyvoltageshown
onthemotor/cabinetnameplate.
Donotinstallorservicetheaircooler
duringrain,highwindorsevereweather
conditions.
!
!
!WARNING
!
!
Allinstallationandrepairworkmust
conformtolocalelectrical,watersupply
andenvironmentalcodes,rulesand
regulationsandapplicablenational
standards.
Allinstallation,maintenanceand
repairworkmustbedonebya
licensedandqualifiedelectrician
and/oraqualified,experienced
heating,ventilating,airconditioning
technician. Allsuchworkmustbe
effectedwithfactoryauthorized
sparepartsonly.
SEELEY INTERNATIONAL – INSTALLATION&OPERATIONMANUAL
2