Digital Linear Scale User Manual
Part No: AE-MAN-DS
Doc V: 1.0
Digital Linear Scales
•Beforeusingthelinearscaleforthersttime,wipewithacleanclothideallysoakedwithcleaningoil.
•Thescaleisaprecisionmeasuringinstrument.Avoidusingexcessiveforce,andtreatwithcare.
•Thettedbatteryisintendedforthefactorytestprocedureandthereforemaynotmeetthespeciedbatterylife.
•Avoidexposuretoallliquids,excessivehumidityortemperature.
•Avoidexposuretobrightsunlight.
•Neverapplyvoltageonanypartofthislinearscaleorelectricengrave.
•Removethebatteryifthescaleisnotbeingusedforalongperiodoftime.
•Neverusesolventstoclean.Onlyuseasoftclothwithcleaningoil.
•Ensurethelinearencoderismountedparallelandcorrectalignmentofthereadinghead.
Precautions
Battery Replacement
2
3
6
1
5
7
1
5
4
3
6
2
8
8
0
5
10
15
20
25
30
35
40
45
7
4
Linear Digital Scale
1. Slide open the battery cover.
8. Insert the two lugs on the
cover.
9. Gently lower battery cover.
2. Lift battery cover front edge.
3. Remove cover.
4. Remove battery
(a magnet tip
tool can be used).
5. Locate side spring contact.
6. Insert replacement battery
edge against side contact.
7. Press down on other edge.
1
2
3
4
5
6
7
8
9
10
11
12
1
2
3
4
5
6
7
8
9
10
11
12
1
2
3
4
5
6
7
8
9
10
11
12
1
2
3
4
5
6
7
8
9
10
11
12
1
2
3
4
5
6
7
8
9
10
11
12
10. Pull battery cover outward
sightly
11. Fully lower cover
12. Slide battery cover fully
closed.
1
2
3
4
5
6
7
8
9
10
11
12
Magnet
tipped
tool
Positive (+)
side up
2
3
6
1
5
7
1
5
4
3
6
2
8
8
0
5
10
15
20
25
30
35
40
45
7
4
TheLinearscalemustbealigned
paralleltothemachinetravel.Usea
dialgaugeorDTItosetparallel.
Thetravelofthereadingheadmust
alsobealignedcorrectlytothescale
beam,otherwisedamagewilloccur.
1.Beamclamp.
2.Beam.
3.Readinghead.
4.LCDdisplay.
5.Functionbutton.
6.Batterycover.
7.Dataoutputcover.
8.Readingheadxing.
Horizontal Type
Vertical Type
© Allendale Group
© Allendale Group © Allendale Group
© Allendale Group
© Allendale Group
© Allendale Group © Allendale Group
© Allendale Group
machine-dro.co.uk
www.machine-dro.co.uk - Allendale Electronics Ltd, Pindar Road, Hoddesdon, Hertfordshire. EN11 0BZ.
Images & Content ©2010 Allendale Electronics Limited. E&OE - Specifi cations subject to change without prior notice.
Digital Linear Scale User Manual
Trouble Shooting
Metric/Inch conversion
25.40
mm
mm/inch
Pressmm/inchtoconvert
frommetrictoinchdisplay.
1.000
Thedisplaywillindicate
whichunitsarebeing
displayed.
mm/inch
in
Scale with ABS Function (not available on all models)
0.00
mm
Zero
PressZERObutton.
30.00
mm
Travelthereadinghead,for
example 30mm
20.00
mm
ABS
PressABSbuttontoswitchto
incremental.Travelthereading
headfor example 20mm.
50.00
mm
ABS
PressABStoswitchback
toAbsolutedisplay.Total
distance traveled from zero.
mm
Scale with Preset Function (not available on all models)
0.00
mm
SET
PressandholdtheSET
button.(IfnoSETbuttonpress
andholdZERO)
SET
20.00
mm
pre+
Pressarrowbuttonsto
increase&decreasevalue.
ReleaseSETbutton.Press
SETdisplaytothepreset.
SET
20.00
mm
Pressupordownarrow
buttonstoincrease&
decreasedisplayvalue.
Zero Display
0.00
mm
ZERO
Press zero to clear
Problem PossibleCause Solution
Flashingdisplay Lowvoltage
Poor contact
Replace battery
Clean contact
Nodisplay Deadorweakbattery
Poor contact
Replace battery
Clean contact
Nochangetodisplay Internalerror
"H"shownondisplay
Remove battery for 1 hour
Remove battery for 5 minutes
Can't zero Holdfunctionactive
Tolerancefunctionactive
Switch off function
Switch off function
Erraticorfrozendisplay Contaminationbetweenbeam&head
lowvoltage
Wipe clean
Replace battery
Erroneousreading Lowvoltage
Contaminationbetweenbeam&head
Scalenotparalleltotravel
Lowambienttemperature
Replace battery
Wipe clean
Adjust parallel with dial gauge/DTI
Store at normal room temperature
INC
Vertical Scale Preset Function
19.80
mm
1
2
3
5
4
6
1
2
3
5
4
6
1
2
3
5
4
6
Positive (+)
side up
Magnet
tipped
tool
Side Type Cover
1. Slide open the battery cover.
2. Remove battery. (a magnet tip
tool can be used).
3. Locate side spring contact.
4. Insert replacement battery
edge against side contact.
5. Press down on other edge.
6. Slide battery cover closed.
Releasearrowbuttonwhen
desiredvalueisdisplayed.
© Allendale Group © Allendale Group © Allendale Group
  • Page 1 1
  • Page 2 2

Allendale Electronics AE-MAN-DS User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI