Prodex-hk PEV-165E User manual

Category
Personal scales
Type
User manual
Deluxe Electronic
Body Fat Analyzer
Body Weight Scale
Instruction Manual Model No.: PEV-165E
Important:
This Body Fat Analyzer/Scale (PEV-165E) will provide body fat readings for a majority of
people, but it is not made for use by the following groups:
Pregnant women/Persons under the age of 18 years (the Body Fat Analyzer/Scale
(PEV-165E) cannot provide accurate body fat readings).
BIA (Bioelectrical Impedance Analysis) mode determines your body fat proportion by
transferring a harmless signal all the way through your body. Do not use this scale if you
have a pacemaker or other internal medial device. When in hesitation, consult with
your physician.
Error (Err) on the L.C.D. Display – You may be able to fix the Err by removing and
re-inserting the batteries. Then follow the How to use the Body Fat + Water + Muscle
Analyzer” (page 4)..
Please see “User Personal Data programming details” (Page 10).
IMPORTANT SAFETY INSTRUCTIONS:
When using this Body Fat Analyzer/Scale PEV-165E, basic precautions should
always be observed, including the following.
1. User must read and understand this manual prior to using this product. Use as described in
this manual. Use manufacturers original accessories and attachments ONLY.
2. Do not use the PEV-165E on Carpet or Rug.
3. Place the PEV-165E on NON-SKID hard, dry and smooth floor/surface.
4. Do not place the PEV-165E on wet surface. Personal Injury Risk!
5. Always put the PEV-165E on the exact same smooth and hard floor/surface to ensure accuracy
of analyser and weight readings. It will ensure the consistency and precise accuracy of the
PEV-165E.
6. Be very careful!. The scale may tilt when you step on it. You should place your left foot or right
foot on the glass platform with an underneath bar supported section, at least with a distant of 1”
from the edge of the glass platform. Once the position is secured and safe, place the other foot
onto the glass section with the supporting bar underneath it..
7. For your safety. Please centre your body weight toward the mid section of the scale before
stepping on / off the scale. Otherwise, the scale may tilt. Personal Injury Risk!
8. Watch your steps and use extra care while using the PEV-165E..
9. Follow all label and marking instructions on your scale.
10. To reduce the risk of electric shock, do not use the scale outdoors.
11. Do not use in area where dangerous items are stored.
12. Do not continue to use this scale if it appears to be malfunctioned.
13. Be very careful! Do you use the Body Fat Analyzer, if the (4) metal plates on top of the glass
platform are loose or not flatly attached onto the glass platform..
14. Do not use this scale if it appears to be uneven, or quaking, while you are on the scale.
15. Do not use this scale if cracks or chips appeared on the glass platform. Personal Injury Risk!
16. If unit is not working as it should, has been damaged, dropped, left out-door, or dropped into
water, bring it to a licensed electrician or shop for service and repair.
17. Do not disassemble the scale. There are no serviceable parts inside the scale.
18. Always bring the damaged appliance to a licensed electrician or shop for service or repair.
19. Never jump on, or jump off the scale. Personal Injury Risk!
20. Observe the battery precautions and battery disposal instructions listed in this manual
21. Do not remove the batteries from the scale. Other than replacing the batteries, or storing your
scale for a long time. The batteries are small parts, and they are extremely danger for children to
swallow. Personal Injury Risk!
22. This scale is not a toy. Do not let children to operate or play with the scale. Please keep it
away from children.
23. Do not use this scale if you have a pacemaker or other internal medial device. When in
hesitation, consult with your physician.
(SAVE THESE INSTRUCTIONS)
Page: 1
Know your Produex Body Fat analyzer / Body weight Scale
Model No.: PEV-165E Diagram (Fig. A)
1. Metal Contact Plates ( 4 plates) 6.
Key
2. L.C.D. Display 7. Glass Platform
3. Plastic
Bars (Left Bar & Right
Bar)
8. Battery Compartment Cover
4.
Key 9. Non Skip Stoppers (4 Stoppers)
5. Set Button 10.
KG / LB / ST Switch
Reset your Body Fat Analyzer / Scale (PEV-165E)
You can easily reset the PEV-165E by removing and re-inserting the batteries (see Fig. A Item
# 8).
Page: 2
Be very careful! When you are stepping on or
off the glass platform. Personal Injury Risk!
Do not stand on the edge of the glass
platform. Personal Injury Risk!
Your left toes section must touch the metal
contact plate on the left side of the LCD
display.
Your right toes section must touch the metal
contact plate on the right side of the LCD
display.
How to measure your Body Weight:
It is not necessary to select user (user 01~ user 10). No programming user date
(Age, Gender and Height) into the scale is needed.
1. Select (lb / in) or (kg / cm) or (st). The Switch is located at the bottom of the scale, on the
backside of the L.C.D. Display (see Fig. AItem #10). (Example: turn switch to lb / in)
2. Place the PEV-165E on a smooth, firm, flat surface to achieve the precise accuracy (do not
use the PEV-165E on Carpet or Rug).
3. Turn-on the PEV-165E: Use foot to tap and press (with a little pressure) the center of the
glass platform to turn on the scale (See Fig. B)
(Fig. B)
4. Remove foot from the glass platform, and within seconds the L.C.D. Display will change to
a zero reading -“ready to use mode”. (See Fig. C)
(Fig. C)
Ready to use mode
5. Step onto the glass platform carefully and stand still to measure your body weight. Once the
“H” is appeared at the top left corner of the L.C.D. Display, the weighing of your body is
completed. (See Fig. D)
(Fig. D)
Example
6. The PEV-165E shuts off by itself after each use.
Page: 3
How to use the Body Fat + Water + Muscle Analyzer (PEV-165E):
Using it for the First Time:
User must select user (user 01 ~ 10) and input user’s personal data (Age, Gender and
Height) prior using the PEV-165E.
Using it for the Second Time and After:
Please see Page 10 for User Personal Data programming details.
1. Select (lb / in) or (kg / cm) or (st). The Switch is located at the bottom of the scale, on the
backside of the L.C.D. Display (see Fig. AItem #10). (Example: turn switch to lb / in)
2. Place the PEV-165E on a smooth, firm, flat surface to achieve the precise accuracy (do not
use the PEV-165E on Carpet or Rug).
3. Turn-on the PEV-165E: Use hand or foot to tap and press (with a little pressure) the center
of the glass platform to turn on the scale. (See Fig. 1)
(Fig. 1)
4. Remove hand or foot from the glass platform and within seconds, the L.C.D. Display will
change to a zero reading -“ready to use mode”. (See Fig. 2)
(Fig. 2)
Ready to set mode
5. Press the Set Button once ((see Fig. AItem #10)). A blinking user 01 will appear on the
L.C.D. Display (See Fig 3.).
(Fig 3)
Blinking User 01
6. Press the
" or " key
(see Fig. A Item # 4 and # 6) to select user; choose from 01 to
user 10
7. Example: If user 01 is selected, press the Set Button (see Fig. A – Item # 5) once to stop the
Blinking of user 01 on the L.C.D. Display. User 01 is now selected.
8. The following L.C.D. Display will come on with the blink Male and Female on the left side
of the display panel (See Fig. 4).
(Fig. 4)
Blinking Male & Female
Page: 4
How to use the Body Fat Analyzer to measure your Body Fat + Body Water +
Muscle + Body Weight:
(continue)
9. Press the
" or " key
(see Fig. A – Item # 4 and # 6) to select Male or Female.
10. Example: Press the
" or " key
(see Fig. A Item # 4 and # 6) to select Female. (See
Fig. 5)
(Fig. 5)
Female is selected
Using the Body Weight Function only: It is not necessary to input user
data (Age, Gender and Height) into the DJ165.
Using the Electronic Body Fat, Body Water, and Muscle Function: It is a
must for the user to select a user setting (user 01~user 10) and input user
data (Age, Gender and Height) into the scale prior using the PEV-165E.
Please see Page 10 for User Personal Data programming details
11. Press the Set Button once (see Fig. A Item # 5) to confirm the selection of Female. The
following L.C.D. Display of blinking “Height” selection will come on. (See Fig. 6)
Pre-set
(Fig. 6)
Blinking Height
12. Press the
" or " key
(see Fig. A – Item # 4 and # 6) to input your Height.
Example: Input 5’9”
13. Press the Set Button once (see Fig. AItem # 5) to confirm the input of your Height. The
following L.C.D. Display of blinking “Age” selection will come on. (See Fig. 7)
Pre-set
(Fig. 7)
Blinking Age
Important: (using the body fat, body water and muscle function)
Data Input - please see Page 10 for User Personal Data programming details.
Page: 5
How to use the Body Fat Analyzer to measure your Body Fat + Body Water +
Muscle + Body Weight
: (continue)
14. Press the
" or " key
(see Fig. A – Item # 4 and # 6) to input your Age.
Example: Input 38
(Fig. 8).
15. Press the Set Button once (see Fig. A Item # 5) to confirm the input of Age. The
following L.C.D. Display will come on (See Fig. 9)
(Fig. 9).
16. Press the Set Button once (see Fig. A Item # 5) to view the following displays to
reconfirm the input of your data (Gender, Height and Age) are programmed correctly.
17. If the numbers are right. Please be-careful and be quick to step on the scale while the LCD
Display is show 0.0 lb. (See Fig 10).
(Fig. 10)
18. Please STAND STILL once you are on the glass platform, the displays will come on as
follows: -
Your weight
(follow with 1 2 3 4 indicating that the PEV-165E is now computing your Body Fat)
19. Please keep stand still on the glass platform. The readings of Body Fat / Body Water /
Muscle
Body Fat Body Water Muscle
The Displays of Body Weight Body Fat Body Water- Muscle will repeat twice and then shut
off automatically to conserve the energy of the batteries (Finished).
Page: 6
Important Note:
This is a high precision electronic PEV-165E. Please handle the unit with care. Do not drop
or throw the unit on floor.
Note:
This Electronic Scale should be used in consistent manner for the precise reading of your body
fat, water, muscle and weight. The readings may very between this analyzer and other methods
of measurement.
The changing in body fat percentage shown by this Electronic Scale will be reflected precisely.
Note:
Drinking coffee, beer, wine, alcohol, and taking diuretic medications or workouts. These all
affect your level of hydration and the accuracy of this analyzer. Please wait a few hours before
taking a body fat reading
Important:
Err: Your feet are not making good contact with the four metal plates on top of the glass
platform.
Monitoring Total Body Water percentage in the body:
Water is an important component of the body. Water combines up approx. 51-69% of the total
body’s weight. It is there partly added in lean tissue compared to fat tissue. Water is a standard for
biochemical reactions that normalize body functions. Waste products are passed in water from
cells for flow in sweat and urine. Water helps to keep body temperature; provides moisture and
lubricates body. The level of water in the body changes with the hydration level of the body.
Watching the level of body water is necessary for one’s health maintenance. The likely Total
Body Water percentage may differ according to your hydration stage. The amount of water you
have drunk or how much you have sweated straight away before to the measurement will affect
the readings. It is recommended that to avoid fluctuation in hydration level before using the scale.
This Electronic Scale uses bioelectrical impedance Analysis, which is one of the most precise
ways of measuring body fat, water and muscle. It sends a harmless signal through the fat and
muscle in your body. It calculates your personal weight, body fat, body water and muscle almost
at the same time. It gives you a more precise reading of your on the whole health and fitness.
Trouble Shooting:
1.
Read and understand this manual completely.
2.
Clean your feet with a clean slightly dampened cloth.
3.
Clean the glass platform and the 4 metal contact plates with a lightly dampened cloth.
4.
Place your unit on the same hard, dry and smooth and flat surface for better performance.
Page: 7
Measure Your Body Fat:
Watching your body fat is important to your health and fitness. Healthy body levels can help
reduce your chances of developing serious health related problems. High blood pressure, high
cholesterol, heart disease, diabetes, and cancer, to name a few are no fun to deal with. Body fat is
also a main factor in athletic performance. It used to be, you would have to see a medical or
professional to obtain information of your body fat. Now, with the Produex’s body Fat Analyzer
and Scale, simply enter your personal data and step onto the scale to obtain the readings by you.
Battery Removal:
Step 1 (Remove Screw)
Step 2 (Remove Cover)
Step 3 (Remove Batteries)
Battery Installation: Reverse the above mentioned 3 steps to install (2) batteries.
Battery Installation:
See Fig. A – Item # 8 (Battery Compartment Cover)
The Electronic Scale uses 2 X 3-Volt Lithium (CR 2032) Cells.
1. Remove Battery compartment cover at the bottom of the scale (see Fig. A Item #8 ) and
insert the 2 X 3-Volt Lithium Cells into battery snap. (Fig. 1)
2. The scale needs to be initialized before first use or after battery replacement: Press lightly on
the scale platform. The display will show “ 8888 “. Then the scale will automatically turn off.
Your scale is now ready for use.
3. Replace the battery when “ Low Battery Warning “ is displayed.
4. Remove the cells if the product is to be stored for a long time.
Battery disposal:
DO NOT DISPOSE OF BATTERIES IN FIRE. BATTERIES MAY EPLODE OR LEAK”
Warning:
“Do not Mix Old and New Batteries. Do not Mix Alkaline, Standard (Carbon-
Zinc.) or
Rechargeable (Nickel Cadmium) Batteries.”
When trashing the batteries -
The batteries must be separated from the regular household
trash. Please consult with your local authorities for batteries disposal instructions.
Page: 8
Battery – First-Aid:
Battery may leaks in extreme weather and conditions. If leaks get on skin and eyes, flush area
with cold water and seek medical attention immediately.
Suggestion:
Suggestion of Body Fat Levels
Age in Years 19-28 yrs. 29-38 yrs. 39-48 yrs. 49-58 yrs 59 plus
Men 14% 15% 17% 18% 19%
Women 19% 20% 21% 22% 23%
** American College of Sports Medicine
1. The percentage total body water of an individual differs according to age and gender. The
table as follows may be used as a suggestion.
Male Female
Age Fat Water Age Fat Water
19-28 8-20% 59 19-28 19-29% 49%
29-38 10-21% 29-38 21-31%
39-48 12-22% 54 39-48 23-33% 48%
49-58 14-24% 49-58 25-35%
59-70 16-28% 49 59-70 27-37% 44%
2. Do measure body fat, body water, or weigh at the same time each day.
3. It is recommended to use the scale without clothing for accurate readings. Clothes can affect
the percentage calculation.
4. Slightly damp Feet must be bard and clean to result accurate readings.
Hydration Level:
This electronic scale computes your weight, the electrical impedance of your body, and adds
those readings with the data of your input (Age, Height, Gender,). The scale will calculate your
body fat percentage accurately. The ideal time for use of this scale is in the evening. Female will
have more difference in water content then male and require watching their reading over a longer
period of time to set up a personal average. You must decide this as a reference only before
calculating progress in a health program. The stage of hydration differs throughout the day and
affects the impedance calculating. If a person is dehydrated, there is a good chance for difference
in the body fat percentage displayed by this electronic scale than when the person is fully
hydrated.
Page: 9
User Personal Data programming details:
Important:
USING IT FOR THE FIRST TIME --
USER MUST NEED to follow
the following instructions to SELECT USER (user 01 ~ user 10) and input user date (Age,
Gender and Height), when using the Body Fat Analyzer to measure your Body Fat, Body Water
and Muscle.
Important:
USING IT FOR THE SECOND TIME AN ON--
After you
done programming your personal data (Age, Gender, Height) into the scale, DO NOT
use the
"SET" button an
y more. Instead, use ONLY the "" or "" key to scroll to the set number (01,
02...10, etc.) before you step onto the scale.
Please follow the following procedures:-
1.
Carefully step onto the glass platform – shoe and socks off (see attached photo)
2.
STEP DOWN from the glass platform immediately, when LCD display shows “8888”.
3.
When the “00” reading appears on the LCD display.
4.
Press "" or "" key to scroll to the set user number (total of 10
users: user 01 ~ user
10).
5.
The readings of your Age, Gender, and Height will appear on the LCD display.
6.
Lastly, the “00” will appear on the LCD display.
7.
ONE SECOND AFTER THE “00” APPEARED ON THE LCD DISPLAY
IMMEDIATELY. STEP ONTO the glass platform and stand still--------.
1. Stand still - Your body weight will come on.
2. Stand still - 1----2----3----4 will come on, showing the monitor is
calculating your
Input data.
3. Stand still - Body Fat reading will come on to the display.
4. Stand still - Hydration reading will come on to the display.
5. Stand still - Muscle reading will come on to the display.
6. Stand still - Body Weight reading will come on to the display.
7. Stand still -
The readings of Body Fat + Hydration + Muscle + Body Weight will
come on twice before the scale turning off itself.
8. Step down from the glass platform (finished).
Precautions:
1. OVERLOAD WARNING: remove the weight immediately when the scale displays “FFFF”.
Otherwise, permanent damage to the scale will occur.
2. This Electronic Body Fat Analyzer/Scale is made for normal home use only; it is not
designed for use in commercial or medical fields.
3. Clean after use with a damp cloth only. Do not use chemical cleaning agents or immerse the
unit into water. Do not let your Analyzer/Scale to turn into saturated with water as it may
damage the electronic components.
4. Precision electronic product. Please handle with care.
Page: 10
Specifications:
Bioelectrical Impedance Analysis to check body fat and total body water percentage.
Weight capacity: 396lbs or 180kg
Weight Graduation: 0.2lb or 100g
Body Fat Graduation: 0.2% (in the range from 3% -55%)
Body water Graduation: 0.2% (in the range from 25-75%)
Muscle Graduation 0.2% (in the range from 25-65%)
Height Range: 3’3” – 7’3” (100 – 220cm)
Age range: 10-100 years
Measures weight, body fat, and body water simultaneously
Weight-only feature with automatic step on
Can be use for up to 10 individuals
User selectable units of measure (lb/in) or (kg/cm) or (st)
Lower battery indicator
Operates on one 2 X 3-Volt (CR2032) Lithium button cells.
Warning:
Changes or modifications to t
his unit not expressly approved by the party responsible for
compliance could void the users authority to operate the equipment.
NOTE:
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of
the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions
,
may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, whic
h can be determined by turning the equipment
off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
-
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
Consult the dealer or an experienced radio TV technician for help.
Page: 11
Important:
When measuring body fat ratio, water ratio and muscle ratio, stand on the platform’s left
and right metal electronic board separately with bare feet.
Clean your feet with a clean slightly dampened cloth.
Place your unit on the same hard, smooth and flat surface for better performance.
Do not put this product under direct sunlight, high temperature or high humidity areas.
After using the scale, do not place any items or objects on the scale for a long period of
time, as it will deplete the batteries.
Clean the glass platform and the 4 metal contact plates with a lightly dampened cloth
Errors Indicator:
When Err is displayed on the LCD Display–Your feet are not making good contact with
the four metal plates on top of the glass platform.
If body fat ratio, water ratio muscle ratio exceeds the range of display because of incorrect
operation, “ERR” will be shown and the scale will be turned off automatically.
Overloading: If the weight exceeds 180.9kg, the screen will display “FFFF”.
Low Battery - Low voltage alert: Change the batteries immediately.
As inner code is too low or too high by the reason that the load cell has been damaged, the
scale will displays ERR), ERR1
Page: 12
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13

Prodex-hk PEV-165E User manual

Category
Personal scales
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI