Smithco TeeJet® Radion 8140 Reference guide

Type
Reference guide
www.teejet.com
REFERENCE GUIDE
1) Change Units
1. From the Operations Screen, press the GREEN ARROW
2. Press the HOME button .
3. From the Home screen, press the CONSOLE button .
4. Press Cultural .
5. Press on the Units selection.
6. Choose US Turf
Figure 1: Navigation Steps to Changing Units
0%
Man
reg
5%
5%
US Turf
English - US
20180603
Imperial
US
Turf
US
Metric
2) Personalize Selectable Information
1. Press either the left or right Selectable Information section.
2. Select one (1) of six (6) available options to display for each side
(options depend upon equipment in use).
Volume Applied – displays volume applied for the current job
number
Flow Rate – displays current ow rate
Flow Pressure – displays current ow pressure
Speed – displays vehicle speed
Area Applied – displays applied area for the selected job
number
Job Number – displays the current job number
To change Job Number go to Home-> Data-> Jobs-> Job
Number.
Figure 2: Selectable Information
Figure 3: Selectable Information Options
2281
gal
15.0
gal/min
52.6
psi
251.5
ac
1
Job#
5.0
mph
Flow Rate
Job Number
Volume Applied
Area Applied
Flow Pressure
Speed
RADION 8140
AUTOMATIC SPRAYER CONTROL REFERENCE GUIDE
SOFTWARE VERSION 1.06
98-01546-R0-ENUS
Radion 8140 Automatic Sprayer Control
3) Establish Target Application Rates
The selected target rate can be changed either on the Operation
screen or in Settings->Job Parameters.
Application Rate displays or give access to:
►Application Rate – while application is active, displays the
actual application rate
►Target Application Rate – while application is inactive, displays
the target rate of product to apply.
◄Automatic regulation mode – Target Application Rate symbol
will be active
Use the Boost/Step Percent Increase/Decrease
buttons
5%
/
5%
to adjust the Target Application Rate
◄Manual Regulation Mode – manual regulation symbol will
remain active
►Preset Target Application Rates Options Menu – denes
the target rate of product to apply for the selected number.
These settings will be the same for all active jobs.
Range is 0 to 700.6 gallons/acre / 6,554 litres/hectare /
16.08 gallons/1,000 square feet.
1. Press the Application Rate selectable section.
2. Select the Target Applicaiton rate to be changed.
3. Press KEYBOARD button .
4. Type the desired rate then press the ACCEPT icon .
Figure 4: Set three different Target Application Rates
40.8
psi
5.0
mph
2.00
gal/1000 sq ft
1.00
gal/1000 sq ft
1.50
gal/1000 sq ft
2.00
gal/1000 sq ft
1.00
gal/1000 sq ft
1.50
gal/1000 sq ft
2.00
gal/1000 sq ft
Application Rate (gal/1000 sq ft)
1 2 3
2.00
Clear
4 5 6 <--
7 8 9
0 . +/-
4) Chose Between Regulation Modes
Automatic Regulation Mode will automatically adjust the application
rate based on the current speed in reference to the target rate.
Manual Regulation Mode will retain an established regulation valve
setting regardless of speed.
Operation Menu Buttons
Home
Auto
reg
Man
reg
Change Between Automatic/Manual Regulation Modes
Automatic Regulation Mode
5%
Target Rate Boost Percent Increase
5%
Target Rate Boost Percent Decrease
0%
Return to Target Rate
Manual regulation mode
Regulation Valve Manual Open
Regulation Valve Manual Close
Close Menu
NOTE: The Regulation button displays the regulation mode that may
be selected not the active regulation mode.
Figure 5: Navigation to Set-up Auto/Manual Mode
0%
Man
Reg
5%
5%
Auto
Reg
www.teejet.com
TEEJET TECHNOLOGIES
5) Establish Simulated Speed
Simulated Speed establishes a speed for using the Simulated Speed
source. Range is 0 to 62.1 miles/hour / 99.9 kilometers/hour.
NOTE: An alarm will sound at start up when active.
1. From the Operations Screen, press the GREEN ARROW
2. Press the HOME button .
3. From the Home screen, press the SETTINGS button .
4. Press Machine .
5. Press Operation .
6. Press Speed Source option then select Simulated Speed .
7. Press Simulate Speed value, then select a speed.
8. Press RETURN arrow to return to the Machine screen.
Figure 6: Navigation to Set-up Simulated Speed
0%
Man
reg
5%
5%
Figure 7: Simulated Speed Source
Simulated
4.5 mph
10%
0.0 mph
Figure 8: Simulated Speed Value
Simulated
4.5 mph
10%
0.0 mph
Simulate Speed (mph)
1 2 3
0
Clear
4 5 6 <--
7 8 9
0 .
Return to Normal Operation Mode
When done operating in Simulated Speen Mode, Speed Source
needs to be returned to Implement Speed.
1. Operations Screen GREEN ARROW -> HOME button ->
SETTINGS button -> Machine -> Operation .
2. Press Speed Source option then select Implement Speed .
3. Press RETURN arrow to return to the Machine screen.
Figure 9: Implement Speed Source
98-01546-ENUS-LT R0 English-US
© TeeJet Technologies 2018
REFERENCE GUIDE
ww w.teejet.com
Copyrights
© 2018 TeeJet Technologies. All rights reserved. No part of this document or the
computer programs described in it may be reproduced, copied, photocopied,
translated, or reduced in any form or by any means, electronic or machine readable,
recording or otherwise, without prior written consent from TeeJet Technologies.
Trademarks
Unless otherwise noted, all other brand or product names are trademarks or
registered trademarks of their respective companies or organizations.
Limitation of Liability
TEEJET TECHNOLOGIES PROVIDES THIS MATERIAL “AS IS” WITHOUT
WARRANTY OF ANY KIND, EITHER EXPRESSED OR IMPLIED. NO
COPYRIGHT LIABILITY OR PATENT IS ASSUMED. IN NO EVENT SHALL
TEEJET TECHNOLOGIES BE LIABLE FOR ANY LOSS OF BUSINESS, LOSS
OF PROFIT, LOSS OF USE OR DATA, INTERRUPTION OF BUSINESS, OR
FOR INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES OF
ANY KIND, EVEN IF TEEJET TECHNOLOGIES HAS BEEN ADVISED OF SUCH
DAMAGES ARISING FROM TEEJET TECHNOLOGIES SOFTWARE.
6) Reset Maximum Tank Content
From the Operation screen, the Filling setup screen can be easly
accessed to reset the tank to the maximum tank content: Full Tank is
unavailable when Tank sensor or Fill Flow Sensor is active.
1. Press TANK
100
.
2. Press Full Tank (unavailable when Tank Sensor or Fill Flow
Sensor is active) to zero out to Actual Content.
3. Press RETURN arrow to return to the Operation screen.
Figure 10: Navigation to Tank Reset
7) Clear Counters
Steps to zero-out all counter numbers (acres and gallons sprayed)
1. From the Operations Screen, press the GREEN ARROW
2. Press the HOME button .
3. From the Home screen, press the DATA button .
Figure 11: How to Zero-out All Counter Numbers
Clear Job Counter
1. Press Job .
2. Press the TRASH CAN button .
3. Press RETURN arrow to return to the main Data screen.
Figure 12: Current Job Counter
Job Number 1
0.00 ac 0 gal
0 ft 0h 0m
Clear Campaign Counters
1. Press Campaign .
2. Press Clear .
3. Press RETURN arrow to return to the main Data screen.
Figure 13: Clear All Campaign Counters
0.00 ac
0 gal
0h 0m
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4