GA9200 SERIES
MANUAL ON/OFF SAFETY VALVE/PILOT KIT
For All Ramp Pan Burner
Natural and Propane/LP Gas Logs
WARNING: If the information in this manual is not fol-


      
       

    -

-



The GA9200 Series Manual On/Off Safety Valve/Pilot kit contains the following:
• Piezo Ignitor 097159-04
Manual Valve 901068-02
Pilot Burner (with natural gas
orice) 901069-01
Piezo Ignitor Electrode 901072-01
Steel Shroud - Pilot Kit 117106-01
Control Dial Instructions 901042-01
Brass 3/8 FLR x 3/8 MPT Elbow 14264
Brass Fitting 14500
Pilot Bracket 117107-01
Flex Connector 101628-01
•18"Propane/LPBrassOrice 104506-22
•24"Propane/LPBrassOrice 104506-16
•30"Propane/LPBrassOrice 104506-30
•Propane/LPPilotBurnerOrice 901070-01
•Screw1/4"#8“B”pt(6ea.) 901075-01
Pilot Valve Control Dial 901079-01
Pilot Valve Dial Extension 3" 901080-01
Propane Conversion Decal 901691-01
Brass 3/8 FLR x 3/8 FPT Elbow 14528
www.desatech.com
117422-01C2
MODEL DESCRIPTION 
Natural Gas
B

Minimum

LSLR18
SMS18
BCS18
PHK18
18" Ramp Pan 60,000
60,000
60,000
60,000
50,000
50,000
50,000
50,000
8"(20.32cm)
dia.
LSLR24
SMS24
BCS24
PHK24
24" Ramp Pan 80,000
80,000
80,000
80,000
70,000
70,000
70,000
70,000
8"(20.32cm)
dia.
PHK30
BCS30
30" Ramp Pan 90,000
90,000
80,000
80,000
8"(20.32cm)
dia.
*Add 6" if safety valve/pilot is used
**At depth indicated


Gas Min. Max.
NG 5.5"
(14cm)
10.5"
(26.6cm)
LP 11"
(27.9cm)
13"
(33cm)

 
LOG SIZE    
LSLR18, SMS18
BCS18, PHK18
0.120 31 0.086 44
LSLR24, SMS24
BCS24, PHK24
0.140 28 0.099 39
PHK30, BCS30 0.150 25 0.106 36
INSTALLATION

MODEL 
WIDTH*
BACK
WIDTH**
DEPTH HEIGHT
LSLR18
SMS18
BCS18
PHK18
28"(71.1cm)
28"(71.1cm)
28"(71.1cm)
28"(71.1cm)
18"(45.7cm)
18"(45.7cm)
18"(45.7cm)
18"(45.7cm)
16"(40.6cm)
16"(40.6cm)
16"(40.6cm)
16"(40.6cm)
18"(45.7cm)
18"(45.7cm)
18"(45.7cm)
18"(45.7cm)
LSLR24
SMS24
BCS24
PHK24
32"(81.3cm)
32"(81.3cm)
36"(91.4cm)
36"(91.4cm)
24"(61cm)
24"(61cm)
23"(58.4cm)
23"(58.4cm)
16"(40.6cm)
16"(40.6cm)
16"(40.6cm)
16"(40.6cm)
18"(45.7cm)
18"(45.7cm)
18"(45.7cm)
18"(45.7cm)
PHK30
BCS30
42"(107cm)
42"(107cm)
29"(73.6cm)
29"(73.6cm)
18"(45.7cm)
18"(45.7cm)
18"(45.7cm)
18"(45.7cm)
Figure 1 - Technical Information Charts
www.desatech.com
117422-01C 3
CHECK GAS TYPE
You must install this ON/OFF Safety Valve/
Pilot Kit if your gas type is propane/LP. For
additional convenience and safety, this ON/
OFF Safety Valve/Pilot Kit can be used with
natural gas. This pilot kit can only be installed
ontherightside(facing)ofthegaslogset.If
you are unsure of the proper application, call
dealer where you bought log set.
Ifthereplacedoesnothaveagassupply
shutoff valve, one must be installed.

  
    


-
    
     


  
    
   
   
   
   

Installation Items Needed
Before installing log set, make sure you have
the items listed below.
• piping(checklocalcodes)
• sealant(resistanttopropane/LPgas)
equipment shutoff valve*
test gauge connection*
• adjustable(crescent)wrenchorpliers
sediment trap
tee joint
pipe wrench
• exiblegasline
10 mm Deep Socket
INSTALLATION
Continued
*A CSA design-certied equipment shutoff
valve with 1/8" NPT tap is an acceptable al-
ternative to test gauge connection. Purchase
theoptionalCSAdesign-certiedequipment
shutoff valve from your dealer.
For propane/LP units, the installer must supply
an external regulator. The external regulator
will reduce incoming gas pressure. You must
reduce incoming gas pressure to between
11" and 14" of water. If you do not reduce
incoming gas pressure, appliance regulator
damage could occur. Install external regula-
tor with the vent pointing down as shown in
Figure 2. Pointing the vent down protects it
from freezing rain or sleet.
WARNING: Never connect




    
     -


     




Figure 2 - External Regulator on
Propane/LP Supply Tank with Vent
Pointing Down
External Regulator
Vent
Pointing
Down
Propane/LP
Supply Tank
www.desatech.com
117422-01C4
Installation must include an equipment shut-
off valve, union, and plugged 1/8" NPT tap.
Locate NPT tap within reach for test gauge
hook up. NPT tap must be upstream from log
set(seeFigure3).
IMPORTANT: Install equipment shutoff valve
in an accessible location. The equipment
shutoff valve is for turning on or shutting off
the gas to the appliance.
Check your building codes for any special
requirements for locating equipment shutoff
valve to appliance.
Apply pipe joint sealant lightly to male NPT
threads(notrequiredonaredttings).This
will prevent excess sealant from going into
pipe. Excess sealant in pipe could result in a
cloggedburnerorice.
    
sealant that is resistant to liquid

INSTALLATION
Continued
Natural Gas
From Gas Meter
(5" W.C.** to 10.5"
W.C.Pressure)

From External
Regulator
(11" W.C.** to 14"
W.C.Pressure)
Figure 3 - Gas Connection
*PurchasetheoptionalCSAdesign-certied
equipment shutoff valve from your dealer.
** Minimum inlet pressure for purpose of input
adjustment.
3"
(7.62cm)
Min.
Sediment Trap (Optional for
Propane/LPInstallation)
CSADesign-Certied
Equipment Shutoff Valve*
Approved Flexible Gas Hose
(ifallowedbylocalcodes)
Cap Pipe Tee
Nipple Joint
We recommend that you install a sediment
trap in supply line as shown in Figure 3.
Locate sediment trap where it is within reach
for cleaning. Install in piping system between
fuel supply and appliance. Locate sediment
trap where trapped matter is not likely to
freeze. A sediment trap traps moisture and
contaminants. This keeps them from going
into log set controls. If sediment trap is not
installed or is installed wrong, log set may
not run properly.
CHECKING GAS CONNECTIONS


 

WARNING: Never use an

-




PIPING SYSTEM


1. Disconnect log set and its individual equip-
ment shutoff valve from gas supply piping
system.
2. Cap off open end of gas pipe where equip-
ment shutoff valve was connected.
3. Pressurize supply piping system by either
opening propane/LP supply tank valve for
propane/LP gas or opening main gas valve
located on or near gas meter for natural gas,
or using compressed air.
4. Check all joints of gas supply piping system.
Applynoncorrosiveleakdetectionuidto
all joints. Bubbles forming show a leak.
5. Correct all leaks at once.
6. Reconnect log set and equipment shutoff
valve to gas supply. Check reconnected
ttingsforleaks.
www.desatech.com
117422-01C 5
Test Pressures Equal To or Less Than

1. Close equipment shutoff valve (see
Figure4).
2. Pressurize supply piping system by either
opening propane/LP supply tank valve
for propane/LP gas or opening main gas
valve located on or near gas meter for
natural gas, or using compressed air.
3. Check all joints from gas meter for natural
gas(Figure5)orpropane/LPsupply(Fig-
ure6)toequipmentshutoffvalve.Apply
noncorrosive leak detection uid to all
joints. Bubbles forming show a leak.
4. Correct all leaks at once.
INSTALLATION
Continued
Figure 4 - Equipment Shutoff Valve
Open
Closed
Equipment
Shutoff Valve
Figure 5 - Checking Gas Joints
(Natural Gas Only)
Gas Meter
Equipment Shutoff Valve
Propane/LP
Supply Tank
Equipment Shutoff
Valve
Figure 6 - Checking Gas Joints
(Propane/LP Gas Only)


Natural Gas Installation
1. Locate air shutter at end of venturi tube
wheretheoriceismounted(seeFigure
7).Loosenscrewandadjustairshutterto
3/16" open position.
2.  Attach burner inlet
ttingtooricebeforereconnectingexline
(seeFigure7).Besuretouseadaptert-
ting from this kit, do not use original adapter
ttingthatcamewithyourappliance.
3. Connectthebrassttingtogasconnector
tubefromthepanburner(seeFigure8).
Be careful not to cause kinks in the tube.
Usethreadsealantonthemalepipetting
and tighten using a wrench.
4. Install the valve/pilot assembly to the
burner pan using the screws provided
(seeFigure8).
5. Push the control rod extension onto the
“D” shaped control rod through the bottom
leftholeinthecover(seeFigure8).Install
piezo ignitor through cover.
Figure 8 - Installing Valve Kit
Piezo Ignitor
Burner
Control Rod
Extension
Valve/Pilot
Assembly
Gas Connector
Tube to Brass
Fitting
Figure 7 - Installing Burner Inlet Fitting
Burner Inlet
Fitting
Burner
Orice
Air Shutter
Underside of
Ramp Burner
Pan
www.desatech.com
117422-01C6
INSTALLATION
Continued
Figure 10 - Installing Propane/LP Pilot
Orice
O
F
F
P
I
L
O
T
O
N
Pilot Injector
2. Besuretousethecorrectoriceforyour
appliance. The hardware kit contains
oricesforeachrespectivesizelogset
as indicated by the model number on
page 2.
3. Screw the propane/LP orifice into the
burner manifold and secure tightly.
4. Locate air shutter at the end of the venturi
tubewhereoriceismounted(seeFigure
9).Loosenscrewandadjustairshutterto
fullyopen(maximum)position.
5. Follow steps 1 through 11 under Natural
Gas Installation, page 5.

The pilot is provided with a natural gas ori-
ceinstalled.Forpropane/LPgasyoumust
remove it and replace it with an propane/LP
orice. The hardware kit contains an pro-
pane/LPoricewitharedstripeforconverting
the pilot.
1. Gently loosen and remove the pilot line con-
nectionfromthebracket(seeFigure10).
2. Replacetheinjector(seeFigure10)with
the propane/LP pilot injector with the red
stripe.
3. Replace and tighten the pilot line to the
bracket.
4. Continue with step 3 under Natural Gas
Installation.
Note: Follow the instructions in your hearth
kit owner’s manual under the section, Testing
Burner for Leaks.
Figure 9 - Replacing Burner Orice
Burner
Orice
Underside of
Ramp Pan
Burner
Air Shutter
6. Install the position decal and control knob
making sure to align the marks with the
correct stop positions of the gas control.
Pilot position will allow the knob to push
inabout1/2"(13mm).Alignthedecalsin
the pilot position.
7. Place the burner pan assembly in the
center of thereplace oor. Makesure
the front of the pan faces forward.
8. Thread the gas supply adaptor to the
replacegassupplypipe.Adjusttomost
convenient position.
9. Install the gas connector tube to the gas
supply adaptor. Carefully shape tube and
attachtogasinlettting.Becarefulnotto
cause kinks in tube.
10. Test for leaks following instructions in your
hearth kit owner’s manual under the sec-
tion Testing Burner for Leaks.
11. Retighten and adjust the location of the
gas control as necessary. The gas control
should be level, with the control rod to the
front.

WARNING: You must use a


To convert to propane/LP gas, the burner
oriceandpilotoricemustbereplaced.The
propane/LP burner orice aresuppliedand
pre-sized for each size log set. The propane/LP
pilotoriceisalsoincludedandcanbeusedto
convert all size log sets.

1. Removethenaturalgasoricefromthe
burner manifold under the ramp pan burner
as shown in Figure 9.
www.desatech.com
117422-01C 7
Pilot Flow
Adjustment
Screw
Figure 11 - Pilot Flow Adjustment Screw
Ignitor
Control Knob
Pilot
FROM "PILOT" POSITION
SLIGHT PUSH TO
TURN OFF
PULL PUSH
TO LIGHT
ON
ON
FROM "PILOT" POSITION
SLIGHT PUSH TO
TURN OFF
PULL PUSH
TO LIGHT
FROM "PILOT" POSITION
SLIGHT PUSH TO
TURN OFF
PULL PUSH
TO LIGHT
ON OFF
On
Off
OFF
OFF
Figure 10 - Ignitor and Control Knob
OPERATING APPLIANCE


     
in the owner's manual included with

     

 -
wise 
 


Safety information and Air For Combus-
tion And Ventilation


    



Note:
      




Pilot
Thermocouple
Figure 11 - Thermocouple and Pilot

TO APPLIANCE
  to

      

     


After installation is complete and the unit has
been ignited, it may be necessary to adjust
thepilot.Useasmallat-headscrewdriverto
turntheowadjustmentscrewonthemanual
controlvalve(seeFigure11).Turnthescrew
counterclockwisetoallowmoregastoowor
clockwisetorestrictgasow.Becarefultolimit
the turns to 2
1
/
2
from the fully closed position.
Further turning can result in gas leaking at the
adjustmentscrewandthepilotamesizewill
diminish.Theproperpilotowwillresultina
strongblueamebetween1/2"and1"long.
INSTALLATION
Continued
      





Note:
-


      
    

Note:


    

    

       

 
 

NoteTroubleshooting sec-
tion in the owner’s manual included

LIMITED WARRANTY
GA9200 SERIES MANUAL ON/OFF SAFETY VALVE/PILOT KIT
DESAHeating,LLCwarrantsthisproducttobefreefromdefectsforone(1)yearfromthedateofrst
purchase, provided that the product has been properly installed, operated and maintained in accordance
with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check
must be presented.
Thiswarrantyisextendedonlytotheoriginalretailpurchaser.Thiswarrantycoversthecostofpart(s)
required to restore this log set to proper operating condition and an allowance for labor when provided by
aDESAHeating,LLCAuthorizedServiceCenter.Warrantypart(s)MUSTbeobtainedthroughauthorized
dealers of this product and/or DESA Heating, LLC who will provide original factory replacement parts.
Failure to use original factory replacement parts voids this warranty. The log set MUST be installed by
aqualiedinstallerinaccordancewithalllocalcodesandinstructionsfurnishedwiththeunit.
This warranty does not apply to parts that are not in original condition because of normal wear and tear,
or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or
defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all
such other costs related to repairing a defective log set will be the responsibility of the owner.
TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE
OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED
WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING
WARRANTIESOFMERCHANTABILITYANDFITNESSFORAPARTICULARPURPOSETOone(1)
YEAR FROM THE DATE OF FIRST PURCHASE; AND DESA HEATING, LLC’S LIABILITY IS HEREBY
LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA HEATING, LLC SHALL NOT
BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR
CONSEQUENTIAL DAMAGES.
Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation
of incidental or consequential damages, so the above limitation on implied warranties, or exclusion or
limitation on damages may not apply to you.
Thiswarrantygivesyouspeciclegalrights,andyoumayalsohaveotherrightsthatvaryfromstate
to state.
For information about this warranty write:
DESA Heating, LLC
2701 Industrial Drive
P.O. Box 90004
Bowling Green, KY 42102-9004
www.desatech.com
WARRANTY INFORMATION
KEEP THIS WARRANTY
Model ______________________________
Serial No. ___________________________
Date Purchased ______________________
Always specify model and serial numbers when communicating with the factory.
The only warranty applicable is our standard written warranty. We make no other warranty, expressed or
implied.
117422-01
Rev. C
03/07
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

Desa Tech GA9200 Owner's manual

Category
Fireplaces
Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages