Kohler K-13816-CP Installation guide

Category
Sanitary ware
Type
Installation guide

This manual is also suitable for

Tools and Materials
Before You Begin
Shut off the main water supply.
Observe all local plumbing codes and building codes.
Provide sufficient reinforcement to the wall.
Select flathead screws that are long enough to secure the base of
the foot control to the finished wall.
Kohler Co. reserves the right to make revisions in the design of
products without notice, as specified in the Price Book.
Adjustable
Wrench
Various
Screwdrivers
Thread
Sealant
Plus:
Three (3) Flathead
Screws
105345-2-AC 2 Kohler Co.
Roughing-In
3/8"
Cold
3/8"
Hot
3/4"
(1.9 cm)
1-1/8"
(2.9 cm)
13-1/2"
(34.3 cm)
14"
(35.6 cm)
3/8" NPT
Inlet
3/8" NPT
Outlet
Three Mounting Holes
for 1/4" Screws
Provide backing.
1/2"
(1.3 cm)
12-1/2"
(31.8 cm)
Pedal in Raised
Position for
Floor Cleaning
3-1/4"
(8.3 cm)
7-3/4"
(19.7 cm)
7-5/8"
(19.4 cm)
2-3/16"
(5.6 cm)
5"
(12.7 cm)
2-3/4"
(7 cm)
3-7/8"
(9.8 cm)
Cover Width
2-1/4"
(5.7 cm)
Between
Hole Centers
for Inlets
5/16"
(8 mm)
14"
(35.6 cm)
This
dimension
must be
maintained.
1-1/4"
(3.2 cm)
Finished
Floor
3/8" NPT
Outlet
Kohler Co. 3 105345-2-AC
1. Install the Foot Control
Secure the Base
Securely tighten the base to the valve with three flathead screws
(provided).
Connect the lavatory or sink supply to the valve. Refer to the
instructions packed with the lavatory or sink supply.
NOTE: Before securing the base to the finished wall, make sure that
sufficient reinforcement has been added to the finished wall.
Using three (3) flathead screws (not provided), secure the base to
the finished wall.
Connect the Supplies
Apply thread sealant to both the hot and cold water supplies.
Connect the hot and cold water supplies to the valve.
Fit the cover in place over the valve and base.
NOTE: If the foot pedals make contact with the cover, the height of
the foot pedals must be adjusted. Remove the cover from the valve
Plated
Screw
Foot Pedals
Hex Nut and
Adjustment Screw
Hot and
Cold Water
Supplies
Key
Secure to wall.
Connect supply here.
Valve
Base
Cover
Flathead Screw
(provided)
Flathead Screw
(not provided)
105345-2-AC 4 Kohler Co.
Install the Foot Control (cont.)
and base. Loosen the hex nuts on the adjustment screws until the
foot pedals are even and will no longer touch the cover. Retighten
the hex nuts. Reinstall the cover over the valve and base, then
recheck the height of the pedals.
Installation Checkout
Turn on the water supply.
Using the key (provided), fully open the valve supply stops.
Check for leaks and repair as needed.
Secure the cover to the valve with the plated screw.
Kohler Co. 5 105345-2-AC
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

Kohler K-13816-CP Installation guide

Category
Sanitary ware
Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI