Danfoss MP08V Receiver User guide

Type
User guide

Danfoss MP08V Receiver is a device designed to receive and process signals from a remote control transmitter. It features 8 digital outputs, 4 analog outputs, and an analog input that can be configured for either voltage or current input. The receiver also has a built-in stop function with Category 3 PLd safety rating, making it suitable for use in safety-critical applications. Additionally, the MP08V Receiver has a compact and rugged design, making it ideal for use in harsh environments.

Danfoss MP08V Receiver is a device designed to receive and process signals from a remote control transmitter. It features 8 digital outputs, 4 analog outputs, and an analog input that can be configured for either voltage or current input. The receiver also has a built-in stop function with Category 3 PLd safety rating, making it suitable for use in safety-critical applications. Additionally, the MP08V Receiver has a compact and rugged design, making it ideal for use in harsh environments.

User Manual
Remote Control
MP08V Receiver
www.danfoss.com
Revision history Table of revisions
Date Changed Rev
January 2019 Rebranded to Danfoss Power Solutions 0101
User Manual
MP08V Receiver
2 |
©
Danfoss | January 2019 BC292480424603en-000101
Safety instructions
General safety....................................................................................................................................................................................4
Safety warnings.................................................................................................................................................................................4
Technical description
Dimensions and identification.....................................................................................................................................................6
Installation
Receiver installation........................................................................................................................................................................ 7
Input and output configuration..................................................................................................................................................8
Digital outputs............................................................................................................................................................................. 8
Analog outputs............................................................................................................................................................................8
MP08V stop category 3 PLd.....................................................................................................................................................8
Pinout............................................................................................................................................................................................10
Troubleshooting
Receiver troubleshooting........................................................................................................................................................... 11
User Manual
MP08V Receiver
Contents
©
Danfoss | January 2019 BC292480424603en-000101 | 3
MP08V general safety
The following safety instructions must be read carefully in order to install and use the product properly
and to keep it in perfect working condition and to reduce the risk of misuse.
Potential damage to operator and product.
Do not use this product on machines in potentially explosive atmospheres unless the model is ATEX/
RATEX certified to do so.
Strictly adhere to the installation instructions contained in this document.
Make sure that professional and competent personnel carry out the installation.
Ensure that all site and prevailing safety regulations are fully respected.
Make sure that this document is permanently available to the operator and maintenance personnel.
Keep the transmission key when the set is not in use.
On starting each working day, check to make sure that the STOP button and other safety measures
are working.
When in doubt, press the STOP button.
Whenever several sets have been installed, make sure the transmitter is the right one. Identify the
machine controlled on the label for this purpose on the transmitter or by using the display (in case it
has one).
Service the equipment periodically.
When carrying out repairs, only use spare parts from Danfoss.
MP08V safety warnings
Potential damage to operator and product.
Follow the guidelines below to reduce risk of injury to the operator and the product.
Use the device with the manufacturer's battery and battery charger (if applicable).
Only allow qualified personnel to operate the equipment.
Always set the STOP button in the off position when not in use.
Always press STOP before plugging in tether cable (if applicable).
Do not operate product when visibility is limited.
Make sure product is compatible with the machine.
Avoid knocking or dropping the product.
Do not use the product if a failure is detected.
Changes or modifications not approved by Danfoss can void the user's authority to operate this product.
User Manual
MP08V Receiver
Safety instructions
4 |
©
Danfoss | January 2019 BC292480424603en-000101
Quick reference precautions
User Manual
MP08V Receiver
Safety instructions
©
Danfoss | January 2019 BC292480424603en-000101 | 5
MP08V dimensions and identification
Dimensions in mm
A
B
1
2
3
4
5
6
6
7
8
35.99
29.20
92.25
101.60
R 3.70
133.03
15.75
42.27
118.73
R 3.70
1. Fixing slots (fixed assembly or anti-vibration)
2. DEUTSCH connector
3. External antenna A60 (433) or A70 (870)
4. Removable internal EEPROM
5. TR800-CE MCX radio
6. External signaling LEDs
7. DEUTSCH connector pinout
8. Switches for the control of voltage options
User Manual
MP08V Receiver
Technical description
6 |
©
Danfoss | January 2019 BC292480424603en-000101
MP08V receiver installation
The below information describes hazards to be aware of during installation and steps to locate the
receiver.
Risk of shock
Completely shut down the machine when installing the receiver.
Check the power supply and shut off the main switch to disconnect the interface cable between the
receiver and the machine's electrical box.
1. Find an easily accessible and clear location with a direct vision between the receiver's antenna and
the transmitter's working area.
2. Optional: If it is difficult to achieve direct vision between the receiver's antenna and the transmitter's
working area, it is recommended to use an extended antenna in a clear location (only for models that
allow an antenna).
In areas of high vibration, the use of dampers is advised.
3. Proceed to connect the power supply. Use the connection block diagram provided with the system,
where the correspondence between the transmitter maneuvers and the receiver's outputs are
detailed.
7
IN2
8
IN1
9
MANUAL
10
GND
11
K3
12
K1
6
IN3
5
IN4
4 3
IN 0-10V
2
K4
1
K2
IN 0-20mA
1
PW
2
1SA4
3
1SA3
4
1SA2
5
1SA1
6
GND
12
STOP
11
+12/24V
10
9
8 7
K1-4
1SA-4 1SA-3
1SA-2 1SA-1
A
B
4. Check if the electrical installation and verify if there's an option to connect the neutral or the ground
cable. In that case, don't forget to connect the ground cable.
The use of fireproof or flame retardant cables are recommended for the connection.
User Manual
MP08V Receiver
Installation
©
Danfoss | January 2019 BC292480424603en-000101 | 7
MP08 input and output configuration
This receiver has one analog input IN 0-10V (without isolation) or IN 0-20mA (without isolation). These
inputs share the same hardware/pins and each one is selected by an internal jumper.
The two inputs cannot be live together at the same time.
The MP08 includes a 7.5A internal fuse.
MP08V digital outputs
The digital outputs k1-k8 have a common contact at pin A1 of the connector. Maximum 2A per output. It
is recommended to use K1 for by-pass valve.
DEUTSCH connector
K1
K2
K3
K4
K5
K6
K7
K8
Pin A1
Pin A12
Pin A2
Pin A11
Pin A3
Pin A10
Pin A4
Pin A9
Pin A5
Pin B2
external connection
Emergency Stop Output
MP08V analog outputs
This receiver allows to choose the control voltage to set up the output power, throughout the selection
of 1 switch.
Control voltage options: 0-5V, 0-10V, 0-Vcc
Analog 1 B7
Analog 2 B5
Analog 3 B8
Analog 4 B4
MP08V stop category 3 PLd
Stop function is performed with 2 relays in serie or in parallel.
B1 and B2 pines should not be connected directly to GND.
User Manual
MP08V Receiver
Installation
8 |
©
Danfoss | January 2019 BC292480424603en-000101
Serie
03.1.3- STOP Category 3 PLd (only in MP08V):
B
B
B
B
C M
NO
1-8
NO
A1
B6 GND
12
2
11
S TO P1
S TO P2
C M
B10 Vdc
C M
NO
1-8
NO
A1
B6 GND
1
S TO P1
S TO P2
C M
B10
SERIE
PARALELO
External
connection
STOP
+IN
STOP
+OUT
C M
NO
1-8
NO
A1
B6
S TO P1
S TO P2
C M
B10
Vdc
C M
NO
1-8
NO
A1
B6
GND
S TO P1
S TO P2
B10
alimentación
salidas digitales
B
B
B
B
12
2
11
1
STOP 1
+OUT
STOP 2
+IN
STOP 2
+OUT
STOP 1
+IN
conexión
externa
03- RECEIVER INSTALLATION
B
B
B
B
C M
NO
1-8
NO
A1
B6 GND
12
2
11
S TO P1
S TO P2
C M
B10 Vdc
C M
NO
1-8
NO
A1
B6 GND
1
S TO P1
S TO P2
C M
B10
SERIE
PARALELO
conexión
externa
STO P
+IN
STO P
+OUT
alimentación
salidas digitales
C M
NO
1-8
NO
A1
B6
S TO P1
S TO P2
C M
B10
Vdc
C M
NO
1-8
NO
A1
B6
GND
S TO P1
S TO P2
B10
B
B
B
B
12
2
11
1
STOP 1
+OUT
STOP 2
+IN
STOP 2
+OUT
STOP 1
+IN
conexión
externa
03.1.4- PINOUT
7
IN2
8
IN1
9
MANUAL
10
GND
11
K3
12
K1
6
IN3
5
IN4
4 3
IN 0-10V
2
K4
1
K2
IN 0-20mA
1
PW
2
1SA4
3
1SA3
4
1SA2
5
1SA1
6
GND
12
STOP
11
+12/24V
10
9
8 7
K1-4
1SA-4 1SA-3
1SA-2 1SA-1
A7
IN2
A8
IN1
A9
K7
A10
K5
A11
K3
A12
K1
A6
In 0-10
A5
K8
A4
A3
A2
K4
A1
K2
B1 B2 B3
CANL
B4
SA4
B5
SA2
B6
GND
B12
B11
+12/24V
B10
B9
B8 B7
CANH
SA3 SA1
K6
Power
K1-8
KSTOP2.1 KSTOP1.1
KSTOP2.2 KSTOP1.2
PINOUT MP08 A
PINOUT MP08 V
A
B
A
B
Diferencias entre MP08A y MP08V
Parallel
03.1.3- STOP Category 3 PLd (only in MP08V):
B
B
B
B
C M
NO
1-8
NO
A1
B6 GND
12
2
11
S TO P1
S TO P2
C M
B10 Vdc
C M
NO
1-8
NO
A1
B6 GND
1
S TO P1
S TO P2
C M
B10
SERIE
PARALELO
External
connection
STOP
+IN
STOP
+OUT
C M
NO
1-8
NO
A1
B6
S TO P1
S TO P2
C M
B10
Vdc
C M
NO
1-8
NO
A1
B6
GND
S TO P1
S TO P2
B10
alimentación
salidas digitales
B
B
B
B
12
2
11
1
STOP 1
+OUT
STOP 2
+IN
STOP 2
+OUT
STOP 1
+IN
conexión
externa
03- RECEIVER INSTALLATION
B
B
B
B
C M
NO
1-8
NO
A1
B6 GND
12
2
11
S TO P1
S TO P2
C M
B10 Vdc
C M
NO
1-8
NO
A1
B6 GND
1
S TO P1
S TO P2
C M
B10
SERIE
PARALELO
conexión
externa
STO P
+IN
STO P
+OUT
alimentación
salidas digitales
C M
NO
1-8
NO
A1
B6
S TO P1
S TO P2
C M
B10
Vdc
C M
NO
1-8
NO
A1
B6
GND
S TO P1
S TO P2
B10
B
B
B
B
12
2
11
1
STOP 1
+OUT
STOP 2
+IN
STOP 2
+OUT
STOP 1
+IN
External
connection
03.1.4- PINOUT
7
IN2
8
IN1
9
MANUAL
10
GND
11
K3
12
K1
6
IN3
5
IN4
4 3
IN 0-10V
2
K4
1
K2
IN 0-20mA
1
PW
2
1SA4
3
1SA3
4
1SA2
5
1SA1
6
GND
12
STOP
11
+12/24V
10
9
8 7
K1-4
1SA-4 1SA-3
1SA-2 1SA-1
A7
IN2
A8
IN1
A9
K7
A10
K5
A11
K3
A12
K1
A6
In 0-10
A5
K8
A4
A3
A2
K4
A1
K2
B1 B2 B3
CANL
B4
SA4
B5
SA2
B6
GND
B12
B11
+12/24V
B10
B9
B8 B7
CANH
SA3 SA1
K6
Power
K1-8
KSTOP2.1 KSTOP1.1
KSTOP2.2 KSTOP1.2
PINOUT MP08 A
PINOUT MP08 V
A
B
A
B
Diferencias entre MP08A y MP08V
User Manual
MP08V Receiver
Installation
©
Danfoss | January 2019 BC292480424603en-000101 | 9
MP08V pinout
Diferencias entre MP08A y MP08V
Pin A Description Pin B Description
1 Power; K1-8 1 KSTOP2.1
2 K2 2 KSTOP1.1
3 K4 3 CANL
4 A6 4 SA4
5 K8 5 SA2
6 In 0-10 6 GND
7 IN2 7 KSTOP2.2
8 IN1 8 KSTOP1.2
9 K7 9 +12/24V
10 K5 10 CANH
11 K3 11 SA3
12 K1 12 SA1
User Manual
MP08V Receiver
Installation
10 |
©
Danfoss | January 2019 BC292480424603en-000101
Receiver troubleshooting
LED Characteristic Description Action
POWER Green; pulsing Receiver is starting up Wait until start-up process is
finished
HARDOK Green; continuous Receiver hardware OK Operate
Red; pulsing EEPROM error; data corruption; CAN bus error (if CANERR
activates)
Reprogram EEPROM
Red; other Electronic board hardware breakdown Replace device
SIGNAL LED off No radio signal detected -
LED on + transmitter switched
off
Radio channel occupied Change transmitter's frequency
channel
LED on + DATA switched off Radio channel occupied by non Danfoss system Change transmitter's frequency
channel
DATA LED off + SINGAL LED on Radio error Replace radio
Green; pulse Receiving good frames OK
ID LED off + DATA LED on No valid ID; Danfoss system nearby If channel not occupied, check
chosen ID in the transmitter or
reset the receiver
LED on + SIGNAL LED on +
DATA LED on
Valid frames received from the transmitter; correct link OK
RELAY Green STOP relay activated -
ORDER Green - -
User Manual
MP08V Receiver
Troubleshooting
©
Danfoss | January 2019 BC292480424603en-000101 | 11
Danfoss Power Solutions is a global manufacturer and supplier of high-quality hydraulic and
electric components. We specialize in providing state-of-the-art technology and solutions
that excel in the harsh operating conditions of the mobile off-highway market as well as the
marine sector. Building on our extensive applications expertise, we work closely with you to
ensure exceptional performance for a broad range of applications. We help you and other
customers around the world speed up system development, reduce costs and bring vehicles
and vessels to market faster.
Danfoss Power Solutions – your strongest partner in mobile hydraulics and mobile
electrification.
Go to www.danfoss.com for further product information.
We offer you expert worldwide support for ensuring the best possible solutions for
outstanding performance. And with an extensive network of Global Service Partners, we also
provide you with comprehensive global service for all of our components.
Local address:
Danfoss
Power Solutions GmbH & Co. OHG
Krokamp 35
D-24539 Neumünster, Germany
Phone: +49 4321 871 0
Danfoss
Power Solutions ApS
Nordborgvej 81
DK-6430 Nordborg, Denmark
Phone: +45 7488 2222
Danfoss
Power Solutions (US) Company
2800 East 13th Street
Ames, IA 50010, USA
Phone: +1 515 239 6000
Danfoss
Power Solutions Trading
(Shanghai) Co., Ltd.
Building #22, No. 1000 Jin Hai Rd
Jin Qiao, Pudong New District
Shanghai, China 201206
Phone: +86 21 3418 5200
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
already on order provided that such alterations can be made without subsequent changes being necessary in specifications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
©
Danfoss | January 2019 BC292480424603en-000101
Products we offer:
DCV directional control
valves
Electric converters
Electric machines
Electric motors
Hydrostatic motors
Hydrostatic pumps
Orbital motors
PLUS+1
®
controllers
PLUS+1
®
displays
PLUS+1
®
joysticks and
pedals
PLUS+1
®
operator
interfaces
PLUS+1
®
sensors
PLUS+1
®
software
PLUS+1
®
software services,
support and training
Position controls and
sensors
PVG proportional valves
Steering components and
systems
Telematics
Comatrol
www.comatrol.com
Turolla
www.turollaocg.com
Hydro-Gear
www.hydro-gear.com
Daikin-Sauer-Danfoss
www.daikin-sauer-danfoss.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Danfoss MP08V Receiver User guide

Type
User guide

Danfoss MP08V Receiver is a device designed to receive and process signals from a remote control transmitter. It features 8 digital outputs, 4 analog outputs, and an analog input that can be configured for either voltage or current input. The receiver also has a built-in stop function with Category 3 PLd safety rating, making it suitable for use in safety-critical applications. Additionally, the MP08V Receiver has a compact and rugged design, making it ideal for use in harsh environments.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI