RIOTEC CR6300C Programming Quick Manual

Type
Programming Quick Manual
Programming Quick Guide
CR6300C/CR6320C/FS5020C
Installation
Make sure that the scanner has the correct cable to plug
into the PC as below described:
1. USB cable connection
(Please use correct cable for the interface)
Reset Configuration to Default
If you are unsure of the scanner configuration or have
scanned the incorrect codes, please read the “Default”
barcode. This will reset the scanner to its factory default.
1.
0B
2.
01802
HID Default
2. Auto-sensing setup
The auto-sensing will be activated while scanner puts on
stand. When scanner is removed from stand, it becomes
trigger mode.
OUTPUT MODE -
KEYBOARD / USB
OUTPUT
MODE
OUTPUT MODE
- RS232 (SERIAL)
Demo
.
000602
SINGLE SCAN
READING
MODE
SINGLE SCAN
NO TRIGGER
Demo
.
Demo
.
LASER TIMEOUT
- 5 SECONDS
LASER TIMEOUT
- 2 SECONDS
01111115
01111112
Keyboard Language
Scan the appropriate country code as below to program the keyboard layout
for your country or language. As a general rule, the following characters are
supported, but need special care for countries other than the United States:
@ | $ # { } [ ] = / ‘ \ < > ~
USA
FINLAND
0005000
0005006
FRANCE
GERMANY
0005007
0005008
ITALY
PORTUGAL
0005011
0005014
NETHERLANDS
NORWAY
0005012
0005013
BELGIUM
SPAIN
0005001
0005017
SWITZERLAND
RUSSIAN
0005016
0005018
SWEDEN
CZECH
0005015
0005004
CANADA
DENMARK
0005003
0005005
GREECE
HUNGARY
0005009
0005010
JAPAN
ENGLAND
0005022
0005021
TURKEY1
TURKEY2
0005019
0005020
Symbologies -1
CODE 11
- ENABLE
CODE 11
CODE 11
- DISABLE
Demo
.
www.tec-it.com
.
CODE 39
- ENABLE
CODE 39
CODE 39
- DISABLE
Demo
.
Demo
.
FULL ASCII
- ENABLE
FULL ASCII
- DISABLE
Demo
.
Demo
.
CODE 93
- ENABLE
CODE 93
CODE 93
- DISABLE
Demo
.
Demo
.
CODE 128
- ENABLE
CODE 128
CODE 128
- DISABLE
Demo
.
Demo
.
CODE 128 ISBT
- ENABLE
CODE 128 ISBT
- DISABLE
Demo
.
Demo
.
CODABAR
- ENABLE
CODABAR
CODABAR
-DISABLE
Demo
.
Demo
.
Symbologies -2
I2OF5
- ENABLE
INTERLEAVED
2 OF 5
I2OF5
- DISABLE
Demo
.
Demo
.
ID2OF5
-ENABLE
INDUSTRIAL
2 OF 5
ID2OF5
- DISABLE
Demo
.
Demo
.
MSI
- ENABLE
MSI
MSI
- DISABLE
Demo
.
Demo
.
UPC-A
- ENABLE
UPC/EAN
UPC-A
-DISABLE
Demo
.
Demo
.
UPC-E -ENABLE
UPC-E
-DISABLE
Demo
.
Demo
.
EAN-13
-ENABLE
EAN-13
-DISABLE
Demo
.
Demo
.
EAN-8
- ENABLE
EAN-8
-DISABLE
Demo
.
www.tec-it.com
.
Information in this document is subject to change without notice.
For more information, please visit:
www.riotec.com.tw