luminii PS-UNI-PR-96-24 Installation guide

  • I have reviewed the installation instructions for the Luminii PS-UNI-PR-96-24 power supply. This document outlines the installation procedures for the unit, with a focus on safety and proper mounting, including requirements for ventilation and distance from pools. I'm ready to assist you with any questions you have about this device.
  • What is the required clearance around the power supply for air circulation?
    How far from the pool is it required to mount the power supply?
    What should be checked before installing the power supply?
Pure DC® Universal Power Supply - Installation Instructions
Model: PS-UNI-PR-96-24
Please read all instructions prior to installation and keep for future reference!
This LED Driver is to be installed in accordance with Article 450 of the National Electrical Code. The LED Driver must be installed in a well
ventilated area and free from explosive gases and vapors. Proper operation requires the free flow of air as this LED Driver is hardwired, it
should only be installed by a qualified electrician. Suitable For Pool and Spa Rated Locations. Installation must also comply with provisions of
the National Electric Code, ANSI/NFPA 70, including those in Article 680 - Swimming Pools, Fountains, and Similar Installations.
7777 Merrimac Ave
Niles, IL 60714
T 224.333.6033
F 224.757.7557
www.luminii.com
REV0.2
12 012 0 2 3
1 / 2
A
B
C
MODELS PS-UNI-PR-96-24
MAX Load 96 watts
A. Length 8.71”
B. Width 4.56”
C. Depth 1.86”
Net Weight 3.5 lbs
*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE
2” min 2” min
2” min
1
3
1.1 Power supply can be mounted vertically or horizontally. With a
minimum of 2” clearance around power supply to provide proper air
circulation.
1.2 Power supply must be placed 5 feet horizontally away from the inside
walls of the pool unless separated from the pool by a solid fence, wall,
or other permanent barrier.
3.1 Insert the 120-277 VAC power into the driver housing from the
electrical panel. Followed by bringing the 24V DC low voltage wires
from the LEDs into the driver housing. In addition bring the controller
wire if applicable. Refer to diagram on page 2 to make all the proper
wiring connecitons.
Before installing, check the label and ensure the LED
Driver has the proper input voltage, output voltage,
and wattage for the job. Check the wire markings to
ensure they match the wiring diagram below. Refer to
table above for the maximum loads!
3.1
2
2.1 Remove the two Phillips screws from the top of the driver housing and
pull the cover off to expose the driver wires.
cover
screw
driver housing
driver housing
24VDC
conduit
120-277 VAC
conduit Controller
2.1
Less than 5’ if there is a solid fence,
wall or permanent barreir in between
Junction box
power supply
Junction box
power supply
Junction box
power supply
Min 5’
Pool
Wall or Barrier
Min 5’
1
Pure DC® Universal Power Supply - Installation Instructions
Model: PS-UNI-PR-96-24
Please read all instructions prior to installation and keep for future reference!
This LED Driver is to be installed in accordance with Article 450 of the National Electrical Code. The LED Driver must be installed in a well
ventilated area and free from explosive gases and vapors. Proper operation requires the free flow of air as this LED Driver is hardwired, it
should only be installed by a qualified electrician. Suitable For Pool and Spa Rated Locations. Installation must also comply with provisions of
the National Electric Code, ANSI/NFPA 70, including those in Article 680 - Swimming Pools, Fountains, and Similar Installations.
7777 Merrimac Ave
Niles, IL 60714
T 224.333.6033
F 224.757.7557
www.luminii.com
REV0.2
12 012 0 2 3
2 / 2
*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE
24V DC+
24V DC-
LineLED
Load
Ground
Neutral
PDCU-PR
DIM +
DIM -
To 0-10V Dimmer
(if applicable)
driver
housing
cover
Note: Over the white, green and
black wires, connect to ELV and
MLV dimmer
5
5.1 Insert the wire nut connections in the driver housing using waterproof
wire nuts and close housing cover. Secure by tightening the two
screws.
5.1
5.1
4
4
4.1 Make sure that all knockouts and openings are properly sealed or
closed with acceptable plugs.
all openings
must be sealed
4.1
PS-UNI-PR-96-24
/