The hold-time adjustment varies the time duration that the load will remain ON when it’s actived by movement detections. The load will automatically be
switched off when the hold-time period elapse if there is no new movements detected prior; should a new movement be detected before the hold-time
elapses, the load will remain ON, another duration of hold-time will be added from the time of detection.
Rotate the dial anti-clockwise toward “+” to increase the hold-time, when the adjustment is fully anti-clockwise, the hold-time setting is 30 minutes. Rotate the
dial clockwise toward “-“ to decrease the hold-time setting, when the adjustment is fully clockwise, the hold-time setting is 10 seconds.