6
After having switched the appliance off and isolated it from the electric mains via the isolating
switch positioned in the rear panel on the appliance, eliminate the jumpers indicated by a
dotted line in the gure and distinguished by the letter A.
Take the external power supply necessary for the liquid soap dispensing pumps functioning to
the two initial clamps.After the previous operation they have a side that is not connected and
are indicated by B1 and B2 in the gure. The external power supply must be:
• 5 ÷ 24Vdc. Phase in clamp B1 and neutral in clamp B2.
• 5 ÷ 24Vdc. Positive in clamp B1 and negative in clamp B2.
Any other value is not allowed.
The table states the activation times of the soap pumps in the standard washing cycles.
Pumps activation time on the relative washing cycles (Firmware 3.29 G400 and G400M version) in
seconds.
Washing
cycle
1 & 11 2 & 12 3 & 13 4 & 14 5 & 15 6 & 16 7 & 17 8 & 18 9 & 19 10
Dis-
pensing
pumps
envi-
sioned
and ac-
tivation
time.
PS1 x
15”
PS1 x
15”
PS1 x
15”
PS1 x
15”
PS1 x
15”
PS1 x
15”
PS1 x
15”
PS1 x
15”
PS1 x
15”
PS3 x
15”
PS2 x
15”
PS1 x
15”
PS2 x
15”
PS2 x
15”
PS2 x
15”
PS2 x
15”
PS1 x
15”
PS1 x
15”
PS2 x
15”
PS3 x
15”
PS3 x
15”
PS3 x
15”
PS3 x
15”
PS3 x
15”
PS3 x
15”
PS2 x
15”
PS2 x
15”
PS3 x
15”
PS3 x
15”
PS3 x
15”
The appliance can be ordered with liquid soap pumps and depending on the number of pumps and
the capacity of the same a kit is supplied with specic instructions. For assembly of the liquid soap
dispensing pumps, refer to the instructions supplied with the pumps themselves.
The appliance has the soap dispensing drawer with set-ups for connection of the liquid soap
loading pipes connection.
To access the connection area remove the lid from the appliance as per instructions stated in
the previous chapters (see details relative to installation).
With the lid removed or raised, it is possible to display the plastic connections on the soap
dispensing drawer.
They are positioned on the lower-rear part of the soap dispensing drawer.
8.4 LIQUID SOAP PUMPS OPTION
8.4.1 WF8G400, WF11G400, WF18G400 LIQUID SOAP INLET
Attention!
• KG 8 G400, KG 11 G400, KG 18 G400.
• The connections have an external diameter of 10 mm. Refer to
the image to identify the 5 holes.
• The connections are all plugged.
• Drill with maximum diameter of 5mm.
• Only make the holes necessary.
• Only drill the rst thin membrane using an electric or battery
operated drill with 5 mm diameter bit.