Graco 24N808 Specification

Category
Garden tools
Type
Specification

This manual is also suitable for

313034H
EN
Operation
LTS 15, LTS 17, ProLTS 17 and ProLTS 19
Airless Sprayers
- For portable spray applications of architectural paints and coatings. For professional use only-
Models 257060, 257065, 24N906, 24N808
3000 psi (21 MPa, 207 bar) Maximum Working Pressure
See page 2 for model and series information including
dispense rate, recommended hose length, guns, and
maximum working pressure.
IMPORTANT SAFETY INSTRUCTIONS.
Read all warnings and instructions in this
manual. Save these instructions.
LTS 15 & LTS 17 Models ONLY: Use water-based or min-
eral spirit-type materials only. Do not use materials having
flash points lower than 70° F (21° C). This includes, but is
not limited to, acetone, xylene, toluene, or naptha. For more
information about your material, request MSDS from distrib-
utor or retailer.
Related Manual:
313036 - Repair
ti11304a
Model: 257060
M
AGNUM LTS 15
MAGNUM LTS 17
Model: 257065
M
AGNUM PROLTS 17
Model: 24N906
M
AGNUM PROLTS 19
Model: 24N808
ti11305a
ti9369b
ti9368b
Specifications
2 313034H
Specifications
This equipment is not intended for use with flammable or combustible materials used in places such as cabinet shops
or other “factory”, or fixed locations. If you intend to use this equipment in this type of application, you must comply
with NFPA 33 and OSHA requirements for the use of flammable and combustible materials.
Model Name Series
Dispense
Rate gpm
(lpm)
Hose Length and
Diameter
Gun
Model
Maximum Working
Pressure
PSI MPa bar
M
AGNUM
LTS 15
B
0.27 gpm
(1.02 lpm)
1/4 in. x 25 ft
(6.4 mm x 7.5 m)
SG2 3000 21 207
M
AGNUM
LTS 17
B
0.31 gpm
(1.17 lpm)
1/4 in. x 25 ft
(6.4 mm x 7.5 m)
SG2 3000 21 207
M
AGNUM
ProLTS 17
A
0.34 gpm
(1.29 lpm)
1/4 in. X 50 ft
(6.4 mm x 15 m)
SG3 3000 21 207
M
AGNUM
ProLTS 19
A
0.38 gpm
(1.44 lpm)
1/4 in. X 50 ft
(6.4 mm x 15 m)
SG3 3000 21 207
Warnings
313034H 3
Warnings
The following warnings are for the setup, use, grounding, maintenance and repair of this equipment. The exclamation
point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risks. Refer back to
these warnings. Additional, product-specific warnings may be found throughout the body of this manual where appli-
cable.
WARNINGWARNINGWARNING
WARNING
GROUNDING
This product must be grounded. In the event of an electrical short circuit, grounding reduces the risk of
electric shock by providing an escape wire for the electric current. This product is equipped with a cord
having a grounding wire with an appropriate grounding plug. The plug must be plugged into an outlet that
is properly installed and grounded in accordance with all local codes and ordinances.
Improper installation of the grounding plug is able to result in a risk of electric shock.
When repair or replacement of the cord or plug is required, do not connect the grounding wire to either
flat blade terminal.
The wire with insulation having an outer surface that is green with or without yellow stripes is the
grounding wire.
Check with a qualified electrician or serviceman when the grounding instructions are not completely
understood, or when in doubt as to whether the product is properly grounded.
Do not modify the plug provided; if it does not fit the outlet, have the proper outlet installed by a quali-
fied electrician.
This product is for use on a nominal 120V circuit and has a grounding plug similar to the plug illustrated
in the figure below.
Only connect the product to an outlet having the same configuration as the plug.
Do not use an adapter with this product.
Extension Cords:
Use only a 3-wire extension cord that has a 3-blade grounding plug and a 3-slot receptacle that
accepts the plug on the product.
Make sure your extension cord is not damaged. If an extension cord is necessary, use 12 AWG (2.5
mm
2
) minimum to carry the current that the product draws. An undersized cord results in a drop in line
voltage and loss of power and overheating.
ti9164a
Warnings
4 313034H
FIRE AND EXPLOSION HAZARD
Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent
fire and explosion:
Do not spray flammable or combustible materials near an open flame or sources of ignition such as cig-
arettes, motors, and electrical equipment. For LTS 15 and LTS 17 models: only use water-based or
mineral spirit-type materials with a flash point greater than 70
° F (21° C).
Paint or solvent flowing through the equipment is able to result in static electricity. Static electricity cre-
ates a risk of fire or explosion in the presence of paint or solvent fumes. All parts of the spray system,
including the pump, hose assembly, spray gun, and objects in and around the spray area shall be prop-
erly grounded to protect against static discharge and sparks. Use Graco conductive or grounded
high-pressure airless paint sprayer hoses.
Verify that all containers and collection systems are grounded to prevent static discharge.
Connect to a grounded outlet and use grounded extensions cords. Do not use a 3-to-2 adapter.
Do not use a paint or a solvent containing halogenated hydrocarbons.
Keep spray area well-ventilated. Keep a good supply of fresh air moving through the area. Keep pump
assembly in a well ventilated area. Do not spray pump assembly.
Do not smoke in the spray area.
Do not operate light switches, engines, or similar spark producing products in the spray area.
Keep area clean and free of paint or solvent containers, rags, and other flammable materials.
Know the contents of the paints and solvents being sprayed. Read all Material Safety Data Sheets
(MSDS) and container labels provided with the paints and solvents. Follow the paint and solvents man-
ufacturer’s safety instructions.
Fire extinguisher equipment shall be present and working.
Sprayer generates sparks. When flammable liquid is used in or near the sprayer or for flushing or
cleaning, keep sprayer at least 20 feet (6 m) away from explosive vapors.
SKIN INJECTION HAZARD
High-pressure spray is able to inject toxins into the body and cause serious bodily injury. In the event that
injection occurs, get immediate surgical treatment.
Do not aim the gun at, or spray any person or animal.
Keep hands and other body parts away from the discharge. For example, do not try to stop leaks with
any part of the body.
Always use the nozzle tip guard. Do not spray without nozzle tip guard in place.
Use Graco nozzle tips.
Use caution when cleaning and changing nozzle tips. In the case where the nozzle tip clogs while
spraying, follow the Pressure Relief Procedure for turning off the unit and relieving the pressure
before removing the nozzle tip to clean.
Do not leave the unit energized or under pressure while unattended. When the unit is not in use, turn
off the unit and follow the Pressure Relief Procedure for turning off the unit.
Check hoses and parts for signs of damage. Replace any damaged hoses or parts.
This system is capable of producing 3000 psi. Use Graco replacement parts or accessories that are
rated a minimum of 3000 psi.
Always engage the trigger lock when not spraying. Verify the trigger lock is functioning properly.
Verify that all connections are secure before operating the unit.
Know how to stop the unit and bleed pressure quickly. Be thoroughly familiar with the controls.
WARNINGWARNINGWARNING
WARNING
Warnings
313034H 5
EQUIPMENT MISUSE HAZARD
Misuse can cause death or serious injury.
Do not operate the unit when fatigued or under the influence of drugs or alcohol.
Do not exceed the maximum working pressure or temperature rating of the lowest rated system com-
ponent. See Technical Data in all equipment manuals.
Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all
equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete information about
your material, request MSDS from distributor or retailer.
Do not leave the work area while equipment is energized or under pressure.
Turn off all equipment and follow the Pressure Relief Procedure when equipment is not in use.
Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manufac-
turer’s replacement parts only.
Do not alter or modify equipment. Alterations or modifications may void agency approvals and create
safety hazards.
Make sure all equipment is rated and approved for the environment in which you are using it.
Use equipment only for its intended purpose. Call your distributor for information.
Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.
Do not kink or over bend hoses or use hoses to pull equipment.
Keep children and animals away from work area.
Comply with all applicable safety regulations.
ELECTRIC SHOCK HAZARD
This equipment must be grounded. Improper grounding, setup, or usage of the system can cause electric
shock.
Turn off and disconnect power cord before servicing equipment.
Connect only to grounded electrical outlets.
Use only 3-wire extension cords.
Ensure ground prongs are intact on power and extension cords.
Do not expose to rain. Store indoors
PRESSURIZED ALUMINUM PARTS HAZARD
Use of fluids that are incompatible with aluminum in pressurized equipment can cause serious chemical
reaction and equipment rupture. Failure to follow this warning can result in death, serious injury, or prop-
erty damage.
Do not use 1,1,1-trichloroethane, methylene chloride, other halogenated hydrocarbon solvents or fluids
containing such solvents.
Many other fluids may contain chemicals that can react with aluminum. Contact your material supplier
for compatibility.
BURN HAZARD
Equipment surfaces and fluid that’s heated can become very hot during operation. To avoid severe burns:
Do not touch hot fluid or equipment.
MOVING PARTS HAZARD
Moving parts can pinch or amputate fingers and other body parts.
Keep clear of moving parts.
Do not operate equipment with protective guards or covers removed.
Pressurized equipment can start without warning. Before checking, moving, or servicing equipment,
follow the Pressure Relief Procedure in this manual. Disconnect power or air supply.
WARNINGWARNINGWARNING
WARNING
Warnings
6 313034H
TOXIC FLUID OR FUMES HAZARD
Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or swal-
lowed.
Read MSDS’s to know the specific hazards of the fluids you are using.
Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines.
PERSONAL PROTECTIVE EQUIPMENT
Wear appropriate protective equipment when in the work area to help prevent serious injury, including eye
injury, hearing loss, inhalation of toxic fumes, and burns. This protective equipment includes but is not lim-
ited to:
Protective eyewear, and hearing protection.
Respirators, protective clothing, and gloves as recommended by the fluid and solvent manufacturer.
WARNINGWARNINGWARNING
WARNING
Installation
313034H 7
Installation
Grounding and Electric
Requirements
Sprayer must be grounded. Grounding reduces the risk
of static and electric shock by providing an escape wire
for electrical current due to static build up or in the event
of a short circuit.
The 120 Vac sprayers
require a 120 Vac, 60
Hz, 15A circuit with a
grounding receptacle.
Never use an outlet
that is not grounded
or an adapter.
Do not use the
sprayer if the electrical cord has
a damaged ground prong.
Only use an extension cord with
an undamaged 3-prong plug.
Recommended extension cords
for use with this sprayer:
50 ft (15.0 m) 14 AWG (2.1 mm
2
)
100 ft (30.0 m) 12 AWG (3.3 mm
2
)
Spray gun
: ground through connection to a properly
grounded fluid hose and pump.
NOTE: Smaller gauge or longer extension cords may
reduce sprayer performance.
Fluid supply container
: follow local code.
Solvent pails used when flushing
: follow local code.
Use only conductive metal pails, placed on a grounded
surface such as concrete. Do not place the pail on a
nonconductive surface, such as paper or cardboard,
which interrupts grounding continuity.
Grounding the metal pail
: connect a ground wire to the
pail by clamping one end to pail and other end to ground
such as a water pipe.
Maintaining grounding continu-
ity when flushing or relieving
pressure: hold metal part of the
spray gun firmly to the side of a
grounded metal pail, then trigger
the gun.
Thermal Overload
Motor has a thermal overload switch to shut itself down
if overheated. If unit overheats, allow approximately 45
minutes for unit to cool. Once cool, switch will close and
unit will restart.
ti5573a
ti5572a
To reduce risk of injury from motor starting unexpect-
edly when it cools, always turn power switch OFF if
motor shuts down.
ti9207a
Component Identification
8 313034H
Component Identification
A
Airless spray gun
Dispenses fluid.
B
Power switch
Turns sprayer ON and OFF.
C
Pressure control knob
Increases (clockwise) and decreases (counter-clockwise) fluid pressure in
pump, hose, and spray gun.
C1
Setting Indicator
To select function, align symbol on pressure control knob with setting
indicator, page 10.
D
Pump fluid outlet fitting
Threaded connection for paint hose.
E
InstaClean
fluid filter
(ProLTS Sprayers only)
Filters fluid coming out of pump to reduce tip plugging and improve
finish.
Self cleans only during pressure relief.
F
Power-Piston
Pump (behind
Easy Access door, not shown)
(ProLTS Sprayers only)
Pumps and pressurizes fluid and delivers it to paint hose.
F1
Easy Access door
(ProLTS Sprayers only)
Easy Access door permits quick access to outlet valve. To remove door, insert
flat blade of screwdriver into slot on the bottom of the door (as shown on page,
7).
G
Suction tube
Draws fluid from paint pail into pump.
H
Prime tube (with diffuser)
Drains fluid in system during priming and pressure relief.
J
Prime/Spray valve
In PRIME position (pointing down) directs fluid to prime tube.
In SPRAY position (pointing forward) directs pressurized fluid to paint
hose.
Automatically relieves system pressure in overpressure situations.
L
Inlet screen
Prevents debris from entering pump.
M
Paint hose
Transports high-pressure fluid from pump to spray gun.
Q
Tip guard
Reduces risk of fluid injection injury.
R
Reversible spray tip
Atomizes fluid being sprayed, forms spray pattern and controls fluid flow
according to hole size.
Reverse unclogs plugged tips without disassembly.
S
Gun trigger safety lever (page
10)
Prevents accidental triggering of spray gun.
T
Gun fluid inlet fitting
Threaded connection for paint hose.
U
Power Flush attachment
Connects garden hose to suction tube for power flushing water-base
fluids.
V
Gun fluid filter
Filters fluid entering spray gun to reduce tip clogs.
W
Hose wrap Rack
Stows paint hose. (LTS 17, ProLTS 17, and ProLTS 19 only)
X
Pail hanger (LTS 17, ProLTS
17, and ProLTS 19 only)
For transporting pail by its handle.
Component Identification
313034H 9
J
E
D
X
B
W
F
C
G
L
H
Q
R
A
S
T
ti9669a
ti11987a
M
ti9368b
C1
ti9346a
ti9670a
F1
U
ti9724a
ti11988a
V (SG2/SG3)
Operation
10 313034H
Operation
Trigger Lock
Always engage the trigger lock when you stop spraying
to prevent the gun from being triggered accidentally by
hand or if dropped or bumped.
Pressure Relief Procedure
Follow this Pressure Relief Procedure whenever you
stop spraying and before cleaning, checking, servicing,
or transporting equipment.
1. Turn power switch OFF and unplug
power cord.
2. Turn Prime/Spray valve to
PRIME to relieve pressure.
3. Hold gun firmly to side of pail.
Trigger the gun to relieve
pressure.
4. Engage trigger lock.
NOTE: Leave Prime/Spray valve in the PRIME
position until you are ready to spray again.
If you suspect the spray tip or hose is clogged or that
pressure has not been fully relieved after following the
steps above, VERY SLOWLY loosen tip guard retaining
nut or hose end coupling to relieve pressure gradually,
then loosen completely. Clear hose or tip obstruction.
Read Unclogging Spray Tip, page 14.
NOTE: To select function, align symbol on pressure control knob with setting indicator on sprayer.
ti8908a
Trigger Locked
Trigger Unlocked
ti8909a
ti2810a
ti9346a
ti11986a
ti8908a
Pressure Control Knob Settings
High Pressure
Spray
Low Pressure
Spray
Prime/
Clean
Rolling
ti5597a
Setup
313034H 11
Setup
1. Unscrew tip and guard assembly
from gun.
2. Uncoil hose and connect one
end to gun. Use two
wrenches to tighten securely
3. Connect other
end of hose to
sprayer.
NOTE: If hose is already connected, make sure connec-
tions are tight.
4. Turn OFF power switch.
5. Turn Pressure Control Knob
all the way left (counter-clockwise)
to minimum pressure.
Prime and Flush Storage Fluid
NOTE: To spray lacquers with the ProLTS 17 and
ProLTS 19, you must purchase lacquer conversion kit
256212, and follow priming procedure for oil-based
materials. The LTS 15 and LTS 17 units are not intended
for lacquers.
Before you use your sprayer for the first time or be-
gin a new spraying project, you need to prime the
sprayer and flush the storage fluid out of the spray-
er.
Oil- or Water-based Materials
When spraying water-based materials, flush the
system thoroughly with water.
When spraying oil-based materials, flush the sys-
tem thoroughly with mineral spirits or compatible,
oil-based flushing solvent.
To spray water-based materials after spraying
oil-based materials, flush the system thoroughly
with water first. The water flowing out of prime tube
should be clear and solvent-free before you begin
spraying the water-based material.
To spray oil-based materials after spraying
water-based materials, flush the system thoroughly
with mineral spirits or a compatible oil-based flush-
ing solvent first. The solvent flowing out of the prime
tube should not contain any water.
When flushing with solvents, ground pail and gun.
Read Grounding and Electric Requirements, page
7.
To avoid fluid splashing back on your skin or into
your eyes, always aim gun at inside wall of pail.
ti11978a
ti11977a
ti9674b
(ProLTS)
ti11456a
(LTS15, LTS 17)
ti2810a
ti9344a
Setup
12 313034H
1. Make sure the power switch is OFF
and the sprayer is unplugged.
2. Separate prime tube (smaller)
from suction tube (larger).
3. Place prime tube in waste pail.
4. Submerge suction tube in
water or flushing solvent.
5. Turn Prime/Spray Valve to
PRIME.
6. Plug sprayer in a grounded out-
let.
7. Turn power switch ON.
8. Align setting indicator with
Prime/Clean setting on Pres-
sure Control knob until pump
starts, page 10.
9. When sprayer starts pumping, flushing solvent and
air bubbles will be purged from system. Allow fluid to
flow out of prime tube, into waste pail, for 30 to 60
seconds.
10. Turn power switch OFF.
11. Transfer suction tube to paint
pail and submerge suction tube
in paint.
12. Turn power switch ON.
13. When you see paint coming
out of prime tube:
a. Point gun into waste pail.
b. Unlock gun trigger lock.
c. Pull and hold gun trigger.
d. Turn Prime/Spray valve to
SPRAY.
NOTE: Some fluids may prime faster if the Power Switch
is momentarily turned off so the pump can slow and
stop. Repeat several times if necessary.
14. Continue to trigger gun into waste pail until you see
only paint coming out of gun.
15. Release trigger. Engage trig-
ger lock.
16. Transfer prime tube to paint pail
and clip prime tube to suction
tube.
Motor stopping indicates pump
and hose are primed with paint.
NOTE: If motor continues to run the sprayer is not prop-
erly primed. To reprime, turn Prime/Spray valve to
PRIME and repeat step 12.
ti2810a
ti2039a
ti9652a
ti9651a
ti9346a
ti5580a
ti9718a
ti2810a
ti9653a
ti5580a
ti9345a
ti8909a
ti8908a
Setup
313034H 13
Install Tip and Guard on Gun
1. Engage trigger lock.
2. Verify tip and guard parts are assembled in order
shown.
3. Screw tip and guard assembly on gun. Tighten
retaining nut.
4. Make sure spray tip is pointing forward in spray posi-
tion.
Spraying Techniques
Preventing Excessive Tip Wear
Spray should be atomized (evenly distributed, no
gaps at edges). Start at low pressure setting,
increase pressure a little at a time until you see a
good spray pattern, without tails.
Spray at lowest pressure that atomizes paint.
If maximum sprayer pressure is not enough for a
good spray pattern, tip is too worn. See Reversible
Spray Tip Selection Chart, page 16.
NOTE: If tails persist when spraying at the highest pres-
sure, a smaller tip is needed or the material may need to
be thinned.
Adjust Spray Pressure
This sprayer is set up for most airless spraying applica-
tions. Details on tip selection, tip wear, coat thickness,
etc. are provided on page 15.
NOTE: Motor only runs when gun is triggered. Sprayer
is designed to stop pumping when gun trigger is
released.
Align setting indicator with function symbol on Pressure
Control knob, page 10.
Turning knob to right (clockwise), increases pres-
sure at gun.
Turning it left (counter-clockwise), decreases pres-
sure.
General spraying instructions are provided in Get-
ting Started with Basic Spraying Techniques section
of this manual, page 17.
ti8908a
retaining nut
black rubber gasket and
guard
tip
ti8911a
metal seat
Use tip to align seat
Tip must be pushed
all the way into guard
in guard
ti9574a
ti5606a
ti11981a
ti9049a
ti5592a
tails-gaps
at edges
pressure
good
spray pattern
too low
Setup
14 313034H
Unclogging Spray Tip
To avoid fluid splash-back:
Never pull gun trigger when arrow-shaped handle is
between SPRAY and UNCLOG positions.
Tip must be pushed all the way into guard.
1. To UNCLOG tip obstruction,
engage trigger lock.
2. Point arrow-shaped handle
backward to UNCLOG posi-
tion.
3. Aim gun at piece of scrap or
cardboard.
4. Unlock trigger lock. Pull trig-
ger to clear clog.
5. When obstruction is
cleared, engage trigger
lock and rotate
arrow-shaped handle back
to SPRAY position.
Point the arrow-shaped
handle on the spray tip forward to SPRAY and
backward to UNCLOG obstructions.
ti8908a
ti9048a
ti8909a
ti9049a
Setup
313034H 15
Tip Selection
Selecting Tip Hole Size
Tips come in a variety of hole sizes for spraying a range
of fluids. Your sprayer includes an 0.015 in (0.38 mm) tip
for use in most spraying applications. Use the following
table to determine the range of recommended tip hole
sizes for each fluid type. If you need a tip other than the
one supplied, see the Reversible Tip Selection Chart
on page 16.
HINTS:
As you spray, the tip wears and enlarges. Starting
with a tip hole size smaller than the maximum will
allow you to spray within the rated flow capacity of
the sprayer.
Maximum tip hole sizes supported by the sprayer:
– LTS 15: 0.015 in. (0.38 mm)
– LTS 17: 0.017 in. (0.43 mm)
– ProLTS 17: 0.017 in. (0.43 mm)
– ProLTS 19: 0.019 in. (0.48 mm)
Choosing the Correct Tip
Consider coating and surface to be sprayed. Make sure
you use best tip hole size for that coating and best fan
width for that surface.
Tip Hole Size
Tip hole size controls flow rate - the amount of paint that
comes out of the gun.
HINTS:
Use larger tip hole sizes with thicker coatings and
smaller tip hole sizes with thinner coatings.
Maximum tip hole sizes supported by sprayer:
– LTS 15: 0.015 in. (0.38 mm)
– LTS 17: 0.017 in. (0.43 mm)
– ProLTS 17: 0.017 in. (0.43 mm)
– ProLTS 19: 0.019 in. (0.48 mm)
Tips wear with use and need periodic replacement.
Fan Width
Fan width is the size of the spray pattern, which deter-
mines the area covered with each stroke. Narrower fans
deliver a thicker coat, and wider fans deliver a thinner
coat.
HINTS:
Select a fan width best suited to the surface being
sprayed.
Wider fans allow provide better coverage on broad,
open surfaces.
Narrower fans provide better control on small, con-
fined surfaces.
Coatings
Tip Hole Size Stains Enamels Primers Interior Paints Exterior Paints
0.011 in. (0.28 mm)
0.013 in. (0.33 mm)
✔✔✔
0.015 in. (0.38 mm)
✔✔
0.017 in. (0.43 mm)
✔✔
0.019 in. (0.48 mm)
Setup
16 313034H
Understanding Tip Number
The last three digits of tip number (i.e.: 221413) contain
information about hole size and fan width on surface
when gun is held 12 in. (30.5 cm) from surface being
sprayed.
Reversible Tip Selection Chart
Example: For an 8 to 10 in. (203 to 254 mm) fan
width and 0.013 (0.33 mm) hole size, order Part No.
221413.
First digit when doubled
= approximate
fan width
413 tip has
8-10 in.
fan width
413 tip has
a 0.013 in
.
hole size
Last two digits = tip hole size in thousands of an inch
ti5559a
Tip
Part
No.
Fan Width 12 in.
(305 mm) from
surface Hole Size
221311 6 - 8 in.
(152 - 203 mm)
0.011 in.
(0.28 mm)
221411 8 - 10 in.
(203 - 254 mm)
0.011 in.
(0.28 mm)
221313 6 - 8 in.
(152 - 203 mm)
0.013 in.
(0.33 mm)
221413 8 - 10 in.
(203 - 254 mm)
0.013 in.
(0.33 mm)
221415 8 - 10 in.
(203 - 254 mm)
0.015 in.
(0.38 mm)
221515 10 - 12 in.
(254 - 305 mm)
0.015 in.
(0.38 mm)
221417 8 - 10 in.
(203 - 254 mm)
0.017 in.
(0.43 mm)
221517 10 - 12 in.
(254 - 305 mm)
0.017 in.
(0.43 mm)
221619 12 - 14 in.
(305 - 356 mm)
0.019 in.
(0.48 mm)
Getting Started With Basic Techniques
313034H 17
Getting Started With Basic Techniques
Use a piece of scrap cardboard to practice these basic
spraying techniques before you begin spraying the sur-
face.
Hold gun 12 in. (30 cm) from surface and aim
straight at surface. Tilting gun to direct spray angle
causes an uneven finish.
Flex wrist to keep gun pointed straight. Fanning gun
to direct spray at angle causes uneven finish.
Triggering Gun
Pull trigger after starting stroke. Release trigger before
end of stroke. Gun must be moving when trigger is
pulled and released.
Aiming Gun
Aim tip of gun at bottom edge of previous stroke, over-
lapping each stroke by half.
12 in.
(30 cm)
even
finish
thick
thin
uneven
finish
ti5585a
even finish thin thick thin
ti2036a
ti2037a
ti2038a
Shutdown and Cleaning
18 313034H
Shutdown and Cleaning
Pail Flushing
For short term shutdown periods (overnight to two
days) refer to Short Term Storage, page 23.
For flushing after spraying oil-based coatings, use
compatible oil-based flushing fluid or mineral spirits.
Read Priming and Flushing Storage Fluid, page 11.
For flushing after spraying water-based coatings,
use water. Read Priming and Flushing Storage
Fluid, page 11 or Power Flush, page 20.
1. Relieve pressure, page 10.
2. Remove tip and guard assembly from gun and place
in flushing fluid.
3. Lift suction tube and prime tube from paint pail. Let
them drain into paint pail for a while.
4. Separate prime tube (smaller) from
suction tube (larger).
5. Place empty waste and
water or solvent pails side
by side.
6. Place prime tube in waste pail.
7. Submerge suction tube in
water or flushing solvent.
8. Turn pressure control knob to
the Prime/Clean setting.
9. Turn power switch ON.
10. Flush until approximately
1/3 of the flushing fluid is emptied from the pail.
11. Turn power switch OFF.
ti2039a
ti9726a
ti9652a
ti9651a
ti9344a
ti5580a
ti2018a
Shutdown and Cleaning
313034H 19
NOTE: Step 12 is for returning paint in hose back to
paint pail. One 50-ft hose holds approximately 1-quart
(1-liter) of paint.
12. To preserve paint in hose:
a. Point gun into paint pail.
b. Unlock gun trigger lock.
c. Pull and hold gun trigger.
d. Turn Prime/Spray valve to
SPRAY.
e. Turn power switch ON.
f. Continue to hold gun trigger until you see paint
diluted with flushing fluid starting to come out of
gun.
13. While continuing to trigger
gun, quickly move gun to
redirect spray into waste
pail. Continue triggering gun
into waste pail until flushing
fluid dispensed from gun is
relatively clear.
14. Stop triggering gun. Engage the
trigger lock.
15. Turn prime/spray valve to
Prime.
16. Turn power switch OFF.
17. Clean InstaClean Fluid Filter
and gun, page 22.
18. Fill unit with Pump Armor
storage fluid. Read Long
Term Storage, page 23.
o preserve paint in hose, trigger gun into paint pail
to expel the remaining paint.
ti9345a
ti5580a
ti8909a
ti9745a
ti8908a
ti9346a
ti2018a
Shutdown and Cleaning
20 313034H
Power Flush
Power flushing is a faster method of flushing. It can only
be used after spraying water-based coatings.
1. Relieve pressure, page 10.
2. Remove tip and guard assembly from gun and place
in waste pail.
3. Place empty waste and
paint pails side by side.
4. Lift suction tube and prime
tube from paint pail. Let them drain into paint for a
while.
5. Place suction and prime tube in waste pail.
6. Turn Pressure Control knob to the
Prime/Clean setting.
7. Screw power flush attachment to
garden hose. Close valve.
8. Turn on water. Open valve. Rinse
paint off suction tube, prime tube
and inlet screen.
9. Turn lever to close power flush
attachment.
10. Unscrew inlet screen from suction
tube. Place inlet screen in waste pail.
11. Connect garden hose to suction tube
with Power Flush attachment. Leave
prime tube in waste pail.
12. Turn power switch ON.
13. Open lever on Power Flush
attachment.
14. Circulate water through
sprayer, into waste pail, for 20 seconds.
15. Turn power switch OFF.
ti9726a
ti9344a
ti9413a
ti9727a
ti2040a
ti2042a
ti5580a
OPEN
ti2043a
ti2018a
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34

Graco 24N808 Specification

Category
Garden tools
Type
Specification
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI