Hunter Fan 53349 Owner's manual

Category
Household fans
Type
Owner's manual

This manual is also suitable for

Hunter Fan 53349 can be used with ceilings that range from 8 feet to 30 inches and angled ceilings of 34 degrees or less. It comes with a standard downrod but you can alternatively mount it with a shorter downrod for ceilings close to the ceiling or a longer downrod for ceilings that are 10 feet or higher. The fan's blades come with pre-drilled holes for easy mounting.

Hunter Fan 53349 can be used with ceilings that range from 8 feet to 30 inches and angled ceilings of 34 degrees or less. It comes with a standard downrod but you can alternatively mount it with a shorter downrod for ceilings close to the ceiling or a longer downrod for ceilings that are 10 feet or higher. The fan's blades come with pre-drilled holes for easy mounting.

www.HunterFan.com
1.866.268.1936
PAGE
7
PAGE
14
PAGE
15
PAGE
5
PAGE
18
PAGE
6
30 inches
7 feet
PAGE
2
What to Expect with
Your Installation
Ceiling Bracket
Ladder
PAGE
3
Tools Needed
PAGE
11
Wiring
Maintenance
& Cleaning
Blades Troubleshooting
Downrod
Switch Housing Light Kit
Preparation
Table of Contents
?
?
?
PAGE
17
Mounting Options
Canopy
PAGE
12
PAGE
13
PAGE
4
Congratulations on purchasing
your new Hunter® ceiling fan! It will
provide comfort and performance
in your home or ofce for many
years. This installation and operation
manual contains complete
instructions for installing and
operating your fan.
We are proud of our work and
appreciate the opportunity to
supply you with the best ceiling fan
available anywhere in the world.
To register your fan, please visit:
www.HunterFan.com/register
Save your receipt for proof of purchase.
PAGE
10
Secondary Hanging
System
1
M3646-01 • 02/07/17 • © 2017 Hunter Fan Company
www.HunterFan.com
2
M3646-01 • 02/07/17 • © 2017 Hunter Fan Company
1.866.268.1936
What to Expect with Your Installation
Know your wiring
If you are unfamiliar
with wiring, use a
qualied electrician.
You may need a
friend to help you.
Check box to see
fan weight
Assess location
30 inches
from blade tip
to nearest wall
or obstruction
7 feet
from bottom
edge of blade
to the oor
Select a downrod length
w.1 - To reduce the risk of re, electrical shock, or
personal injury, mount fan directly from building
structure and/or an outlet box marked acceptable for
fan support of 70 lbs (31.8 kg) and use the mounting
screws provided with the outlet box.
w.2 - To avoid possible electrical shock, before installing
or servicing your fan, disconnect the power by turning
off the circuit breakers to the outlet box and associated
wall switch location. If you cannot lock the circuit
breakers in the off position, securely fasten a prominent
warning device, such as a tag, to the service panel.
w.3 - To reduce the risk of re, electrical shock, or motor
damage, use only Hunter Solid State Speed Controls.
w.4 - To reduce the risk of personal injury, do not bend the
blade brackets when installing the blade brackets, balancing
the blades, or cleaning the fan. Do not insert foreign objects
in between rotating fan blades.
c.1 - All wiring must be in accordance with national and
local electrical codes ANSI/NFPA 70. If you are unfamiliar
with wiring, use a qualied electrician.
c.2 - Use only Hunter replacement parts.
Assess ceiling angle
Read and Save These Instructions
This product conforms to UL Standard 507.
WARNINGS
CAUTIONS
Must be able to
secure the fan to
building structure or
fan-rated outlet box
1
2
3
Standard Downrod
for ceilings 8-10 feet high
Shorter Downrod
for fans installed close to ceiling
Longer Downrod
for ceilings 10 feet or higher
Ceiling angles greater
than 34° will require an
Angled Mounting Kit.
See page 4 for details.
www.HunterFan.com
1.866.268.1936
Tools Needed
Ladder
Power Drill
(optional)
9/64” Drill Bit
(optional)
Screwdrivers
Pliers Wire Strippers
If mounting to a support structure, you will also need these tools.
3
M3646-01 • 02/07/17 • © 2017 Hunter Fan Company
www.HunterFan.com
4
M3646-01 • 02/07/17 • © 2017 Hunter Fan Company
1.866.268.1936
If you have an angled ceiling:
1. You will need a longer downrod (sold separately).
2. If your ceiling angle is greater than 34°, you will
also need an Angled Mounting Kit (sold separately).
Guide Touches
BOTH Ceiling & Wall
S
I
T
U
A
T
I
O
N
1
Guide Touches
Wall
but
NOT Ceiling
S
I
T
U
A
T
I
O
N
2
You need BOTH
a Longer
Downrod &
an Angled
Mounting Kit
You need ONLY
a Longer
Downrod
*most common
If you have a at ceiling:
Hang your fan by a standard downrod (included).
Mounting Options
Use Standard Mounting
or Low-Prole Mounting
to hang the fan from a at ceiling.
Use Angled Mounting
to hang the fan from a
vaulted or angled ceiling.
34
O
CEILING
WALL
OPTION
1
Standard
Mounting
OPTION
2
Angled
Mounting
2 3
SLIDE
toward ceiling
PLACE
against wall
1
FOLD
on dotted line
34°
Use the three steps below to determine if your ceiling angle is greater than 34°
Support
Structure
Ceiling
Outlet Box
(required)
Angled
Mounting
Style
Standard
Mounting
Style
Support
Structure
Ceiling
Outlet Box
(required)
www.HunterFan.com
1.866.268.1936
Ceiling Bracket
OFF
Make sure all four bumpers are
still attached.
For angled ceilings, point
opening toward peak.
Refer to warning w.1 on pg. 2
To avoid possible electrical shock, before
installing your fan, disconnect the power by
turning off the circuit breakers to the outlet
box associated with the wall switch location.
If you are unable to do this,
call Technical Support at
1-888-830-1326.
Use wood screws
(included) when securing
to support structure with
approved electrical outlet
box. Drill 9/64” pilot holes
in support structure to aid
in securing ceiling bracket
with hardware found in
the hardware bag.
Use machine screws
(provided with outlet
box) when securing to
existing ceiling fan-rated
outlet box. Make sure
it is securely installed
and is acceptable for fan
support of 31.8 kg (70 lbs)
or less.
Turn Power
5
M3646-01 • 02/07/17 • © 2017 Hunter Fan Company
www.HunterFan.com
1.866.268.1936
Ceiling Bracket (continued)
Preparation
D
I
S
C
A
R
D
K
E
E
P
!
Remove the shipping blocks from the
motor. Save the screws. They will be
needed for blade iron installation.
Note: Some fans will have a shipping
ring instead of shipping blocks. Please
remove the ring and save the screws.
Time Saver Tip: Get a helper
to insert grommets, found in
the hardware bag, into the
blades while you’re doing the
next couple of steps.
6
M3646-01 • 02/07/17 • © 2017 Hunter Fan Company
www.HunterFan.com
1.866.268.1936
Downrod
Slide
Slide
1 2 3 4 5
678910
Sold Separately
Included
Longer
Downrod
for angled
ceilings or
ceilings 10’ or
higher
Shorter
Downrod
for fans installed
close to ceiling
Standard
Downrod
for ceilings 8-10’ high
Option 1Option 2
Option 3
skip to next page
If you need a different downrod length follow these steps:
Steps 1-5 to remove standard downrod pipe
Steps 6-10 to reassemble with new pipe
Included
(pre-assembled)
7
M3646-01 • 02/07/17 • © 2017 Hunter Fan Company
www.HunterFan.com
1.866.268.1936
KEEP!
8”
3/8”
C
U
T
&
S
T
R
I
P
(not to scale)
Remove the pre-installed
setscrew so that the downrod
can be inserted.
Hand tighten the downrod (at
least 4-5 full turns) until it stops.
The wires can be cut, but
leave at least 8” extending
from the top of the downrod.
Downrod (continued)
8”
3/8”
Tighten the setscrew
with pliers. DO NOT
HAND TIGHTEN.
If the setscrew is not tightened
securely, the fan may fall.
K
E
E
P
!
8
M3646-01 • 02/07/17 • © 2017 Hunter Fan Company
www.HunterFan.com
1.866.268.1936
Downrod (continued)
Put the wires and downrod through
the canopy. Let the canopy sit loosely
on top of the fan.
DO NOT PICK THE FAN UP BY THE
CANOPY OR WIRES. Place the downrod
ball into the slot in the ceiling bracket.
9
M3646-01 • 02/07/17 • © 2017 Hunter Fan Company
www.HunterFan.com
1.866.268.1936
Secondary Hanging System
3mm (1/8")
Insert the looped end of the
braided cable through the ceiling
bracket and one of the holes in the
outlet box into the ceiling. Access
the support brace in the ceiling.
You may not be able to do this from
below the ceiling depending on
your installation site.
Drive the wood screw and
washer found in the bag
into the side of the support
brace that holds the outlet box.
Leave 3 mm (1/8”) of space
between the support brace
and the washer.
Wrap the braided cable around
the support brace once creating
a complete circle. Hook the
looped end of the cable over the
wood screw so that the cable
lies between the washer and the
support brace.
Tighten the loop and secure the
screw and washer all the way
down to the support brace. Coil
up the excess cable.
Outlet Box
Ceiling
Support
Brace
Braided
Cable
10
M3646-01 • 02/07/17 • © 2017 Hunter Fan Company
www.HunterFan.com
1.866.268.1936
Wiring
F
R
O
M
F
A
N
F
R
O
M
C
E
I
L
I
N
G
B
R
A
C
K
E
T
F
R
O
M
F
A
N
Using an orange wire
connector from
the hardware bag,
connect the 3 grounding
wires (green, green/
yellow stripe, or bare
copper) coming from the
ceiling, downrod, and
hanging bracket.
(Grounding)
Green/Yellow
Stripe
Green/Yellow
Stripe
White
Black
(Grounded)
Note: To connect the wires,
hold the bare metal leads
together and place a wire
connector over them, then twist
clockwise until tight.
Using the orange wire
connectors from
the hardware bag, connect
the black wire (ungrounded)
from the ceiling to the black
and the blue wires from the
fan. Connect the white wire
(grounded) from the ceiling to
the white wire from the fan.
Using the orange wire
connectors from
the hardware bag,
connect the white wire
(grounded) from the
ceiling to the white wire
from the fan.
Connect the black wire
(ungrounded) from the
ceiling to the black wire
from the fan. Connect the
second (ungrounded) wire
from the ceiling to the blue
wire from the fan.
F
R
O
M
F
A
N
White
(Ungrounded)
Black
Blue
(Grounded)
F
R
O
M
C
E
I
L
I
N
G
(Ungrounded)
Blue
For Dual Switches
For a Single Switch
F
R
O
M
C
E
I
L
I
N
G
F
R
O
M
C
E
I
L
I
N
G
Turn the splices upward and push them carefully back through the hanger bracket
into the outlet box. Spread the wires apart, with the grounded wires on one side of
the outlet box and the ungrounded wires on the other side of the outlet box.
Refer to CAUTION c.1 on pg. 2
11
M3646-01 • 02/07/17 • © 2017 Hunter Fan Company
(Ungrounded)
www.HunterFan.com
1.866.268.1936
Canopy
Lift the canopy into place so that
the screw holes are aligned.
Position the canopy so that, when
lifted into place, the canopy ts into
the hanging bracket as shown.
Screw
Holes
Insert the two canopy screws
found in the hardware bag.
12
M3646-01 • 02/07/17 • © 2017 Hunter Fan Company
www.HunterFan.com
1.866.268.1936
Blades
13
Insert grommets found in the hardware
bag into the holes in the blades, then
secure each blade to a blade iron with
screws found in the hardware bag.
Remember the screws that
you kept after removing the
shipping blocks (page 6)? You
need them for this step.
Lightly attach each blade iron to the
motor housing with the blade iron
armature screws. Securely tighten after
both screws are attached.
13
M3646-01 • 02/07/17 • © 2017 Hunter Fan Company
www.HunterFan.com
1.866.268.1936
Feed the wire plug through the center
hole of the upper switch housing, then
wrap keyhole slots around the screws and
twist counterclockwise.
Screw two housing assembly screws
from the hardware bag halfway into
the motor housing. It does not matter
which two screw holes you choose.
Insert the third screw, found in
the hardware bag, into place and
then tighten all three screws.
Make sure the upper switch housing is securely
attached to the mounting plate. Failure to properly
secure all three assembly screws could result in the
switch housing xture falling.
Switch Housing
14
M3646-01 • 02/07/17 • © 2017 Hunter Fan Company
www.HunterFan.com
1.866.268.1936
Light Kit
Make sure the lower switch housing is securely attached to
the upper switch housing. Failure to properly secure all three
assembly screws could result in the light xture falling.
Want to install your fan without a light kit?
Go to www.HunterFan.com/FAQs and click
“How do I install my fan without the light kit?”
Connect the plugs from the upper and lower
switch housings. Make sure to line up the
colored markings on the connectors.
Partially install two of the switch housing
screws found in the hardware bag. Align
the notches in the sides of the lower switch
housing with the screws on the upper switch
housing. Twist the lower switch housing
clockwise to lock into place.
Install the third switch housing screw.
Tighten all three screws securely.
Switch
Housing
Screw
Notch
15
M3646-01 • 02/07/17 • © 2017 Hunter Fan Company
www.HunterFan.com
1.866.268.1936
Light Kit (continued)
CONGRATULATIONS!
YOU’RE DONE!
Install a bulb into each of
the sockets. When necessary,
replace with bulbs of the same
type and wattage.
See next page for fan
operation instructions.
Connect the appropriate pull
chain pendant to each of the
short chains coming from the
switch housing.
Note: In compliance with US federal energy regulations, this ceiling fan
contains a device that restricts its light output. Exceeding the wattage
limit marked on the MAX wattage sticker afxed to the light socket(s)
may result in re hazard or improper operation.
Fan
Pull
Chain
Light
Pull
Chain
Bulb
To install each shade, rst loosen
the thumbscrews. Carefully raise
the shade to the light xture and
tighten all thumbscrews securely.
Shade
Thumbscrew
16
M3646-01 • 02/07/17 • © 2017 Hunter Fan Company
www.HunterFan.com
1.866.268.1936
Maintenance & Cleaning
The fan pull chain controls the
speed: from high to off.
The light pull chain controls the
light xture: on and off.
To switch the direction of air
ow, move the reverse switch to
the opposite position.
ON
Turn Power
For cleaning the fan, use soft
brushes or cloths to prevent
scratching. Cleaning products
may damage the nishes.
Reverse
Switch
17
M3646-01 • 02/07/17 • © 2017 Hunter Fan Company
For questions regarding removing a light kit, call
customer service 1-888-830-1326.
www.HunterFan.com
1.866.268.1936
Troubleshooting
Excessive wobbling
Tighten all of the blade and
blade iron screws until they
are snug.
Turn the power off, support
the fan carefully, and check
that the hanger ball is
properly seated.
Use the provided balancing
kit and instructions to balance
the fan.
Noisy Operation
Tighten the blade and blade
iron screws until they are snug.
Check to see if any of the
blades are cracked. If so, replace
all of the blades.
Fan doesn’t work
Make sure power switch is on.
Pull the pull chain to make sure
it is on.
Push the motor reversing switch
rmly left or right to ensure that
it is engaged.
Check the circuit breaker to
ensure the power is turned on.
Make sure the blades spin freely.
Turn off power from the circuit
breaker, then loosen the canopy
and check all the connections
according to the wiring diagram
on page 11.
Check the plug connection in
the switch housing.
Lights dim when turned on or
do not turn on at all.
Make sure the wattage of the
light bulbs installed matches
the specications on the light
sockets.
18
M3646-01 • 02/07/17 • © 2017 Hunter Fan Company
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18

Hunter Fan 53349 Owner's manual

Category
Household fans
Type
Owner's manual
This manual is also suitable for

Hunter Fan 53349 can be used with ceilings that range from 8 feet to 30 inches and angled ceilings of 34 degrees or less. It comes with a standard downrod but you can alternatively mount it with a shorter downrod for ceilings close to the ceiling or a longer downrod for ceilings that are 10 feet or higher. The fan's blades come with pre-drilled holes for easy mounting.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI