Datalogic ULYXE FAMILY User manual

Type
User manual

This manual is also suitable for

USER’S MANUAL
>Ulyxe PL
TM
ii
Datalogic S.r.l.
Via S. Vitalino 13
40012 Calderara di Reno
Italy
Ulyxe PL
TM
User’s Manual
Ed.: 06/2017
© 2009 - 2017 Datalogic S.p.A. and/or its affiliates ALL RIGHTS RESERVED. Without
limiting the rights under copyright, no part of this documentation may be reproduced,
stored in or introduced into a retrieval system, or transmitted in any form or by any means,
or for any purpose, without the express written permission of Datalogic S.p.A. and/or its
affiliates. Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in
many countries, including the U.S.A. and the E.U.
Ulyxe, Ulyxe PL, Lighter Suite are trademarks of Datalogic S.p.A. and/or affiliates. All other
trademarks and brands are property of their respective owners.
Datalogic reserves the right to make modifications and improvements without prior
notification.
Datalogic shall not be liable for technical or editorial errors or omissions contained herein,
nor for incidental or consequential damages resulting from the use of this material.
821002094 rev. E
iii
SYMBOLS
Symbols used in this manual along with their meaning are shown below. Symbols and signs are repeated
within the chapters and/or sections and have the following meaning:
Generic Warning:
This symbol indicates the need to read the manual carefully or the necessity of an important
maneuver or maintenance operation
.
Electricity Warning:
This symbol indicates dangerous voltage associated with the laser product, or powerful enough to
constitute an electrical risk. This symbol may also appear on the marking system at the risk area
.
Laser Warning:
This symbol indicates the danger of exposure to visible or invisible laser radiation. This symbol may
also appear on the marking system at the risk area
.
Fire Warning:
This symbol indicates the danger of a fire when processing flammable materials. Because there is a
danger of fire, it is indispensable to follow the instructions provided by the manufacturer when
commissioning the marking system
.
Notice:
Notes, usage tips, or additional information.
Note:
Carefully read the user’s manual before using the marking system.
iv
REVISION INDEX
Revision Date Number of added or edited pages
A 03-03-2009
Complete Revision for
Ulyxe PL2.0
B 15-10-2009 Datalogic Automation format
C 12-03-2010 Standards References
D 27-09-2010
Environmental Declaration
Windows
®
7 compatibility
821002090 rev. A 02-05-2012
Power supply plug and connector;
Prerequisites for installation
821002091 rev. B 20-06-2012 General Review
821002092 rev. C 10-04-2014 12, 23, 48, 49 Appendix E
821002093 rev. D 13-06-2016
General Review
821002094 rev. E 06-06-2017
ii
NOTE:
We sometimes update the documentation after original publication. Therefore, you should also
review the documentation on www.datalogic.com for any updates.
v
FOREWORD
Information included in this manual is intended for a qualified installer able to integrate the marking
system into a system, complying with all the protection features required by international rules and
local legislations. Refer to the Appendices for further information.
Following manual refers to an Ulyxe
TM
1PWX-T15 marking system in Class 4 configuration.
In addition to being professionally trained in their role, personnel assigned to work on the marking system
must be informed and made acquainted with the risks inherent to invisible and visible laser radiation. The
operator is required to carefully read the section of the manual concerning safety instructions as well as the
sections related to matters falling under her/his responsibility.
The workers assigned to the marking system can be identified as:
OPERATOR
responsible for loading elements to be processed, visually checking the work cycle, removing the
finished product and cleaning the marking system.
MAINTENANCE PERSONNEL
responsible for the electrical, mechanical and optical maintenance and adjustment of the marking
system.
WARNING!
Datalogic shall not be held responsible for any non-conforming use of marking system of its
manufacture
.
NOTE:
BEFORE INSTALLING AND USING THE LASER, READ CAREFULLY THE APPENDICES.
PATENTS
See www.patents.datalogic.com for patent list.
This product is covered by one or more of the following patents:
Utility patents: IT1366132, US7480318
vi
OVERVIEW
We are satisfied of your choice for a Datalogic product and especially for an “ALL IN ONE” compact system
made from experience years in laser marking field.
The marking system Ulyxe PL
TM
belongs to a Diode Pumped Solid State (DPSS) Q-switched side pumped
laser category.
Its simple and compact design conveys a versatile, intuitive and easy product to integrate due to its
advanced technology.
Easy to use, it can be the best investment to entry in the laser world without compromises about
performance and to obtain excellent markings.
Ulyxe PL
TM
system includes all necessary to operate, a laser source DPSS Q-switched, a galvanometer
scanning head, digital power controls, cooling system and monitoring functions. The entire unit and its
mechanical base are covered with a metal casing that makes it more resistant to external agents.
The user can easily interacts and monitors laser status and its functions with an easy use of an external LCD
Touch Screen control display (optional).
Figure 1:Overview.
WARNING!
Marking system installation in secure environment is responsibility of the system integrator!
vii
IMPORTANT WARNING
Access to the internal parts of the marking system is allowed only to authorized personnel, duly qualified and
trained with regards to risks of optical and electrical nature.
Datalogic declines any and all responsibility for work carried out on live parts by untrained or unauthorized
personnel.
WARNING!
It’s not allowed modify destination use of the marking system in different way of its functions.
Datalogic declines any responsibility and liability for irregular and improper use of the marking
system which it manufactures.
WARNING!
These marking system actuation is demanded to the system integrator.
viii
USB 2.0 ADVICE
Ulyxe PLexclusively works via USB 2.0 Full Speed only. Certain hardware configurations and certain
operative systems do not fully support the requested connection.
It is suggested to perform the following checks:
Use only USB cables certified “ HIGH SPEED” or quality “USB2.0” cable, not longer than 2 meters.
Avoid using any kind of extension cable or any HUB on the cable path.
Verify the compatibility of the operative system.
Some computers support only one USB2.0 at a time. On those systems, the use of other devices
(USB memories, external HD, etc.) can disconnect the Ulyxe PLperipheral devices (in particular it
is observed that any USB 2.0 peripheral connected for last in temporal order isn’t recognized from
O.S.).
ix
TABLE OF CONTENTS
SYMBOLS III
REVISION INDEX IV
FOREWORD V
PATENTS v
OVERVIEW VI
IMPORTANT WARNING vii
USB 2.0 ADVICE VIII
TABLE OF CONTENTS IX
1. CONTENTS OF THE PACKAGING 11
1.1 UNPACKING 11
1.2 MAIN HARDWARE 12
1.3 CABLE AND ACCESSORIES 12
1.4 TRANSPORT 13
1.5 ON MOISTURE CONDENSATION 13
1.6 FIXING AND POSITIONING 14
1.7 INSTALLATION ENVIRONMENT 15
1.8 FUME / DUST EXTRACTOR 15
2. TECHNICAL SPECIFICATIONS 16
2.1 TECHNICAL SPECIFICATION 16
2.2 DESCRIPTION OF THE LASER
MODULES 18
2.3 MARKING AREA SPECIFICATION 19
2.4 CONNECTORS SPECIFICATIONS 21
2.4.1 AUX INTERLOCK CONNECTOR (SW LEVEL) 21
2.4.2 CONTROL BOX CONNECTOR (LASER CONTROL) 22
2.4.3 POWER SUPPLY CONNECTOR 24
2.4.4 POWER SUPPLY CABLE 24
2.4.5 RS232 CONNECTOR 24
2.5 INPUT/OUTPUT SIGNAL SPECIFICATIONS 25
2.6 CONNECTION EXAMPLE 26
3. INSTALLATION AND SET UP 28
3.1 LIGHTER SUITE INSTALLATION 28
3.2 CONNECTIONS 33
3.2.1 CONTROL BOX CONNECTOR CONNECTION 33
3.2.2 AUX INTERLOCK CONNECTION 34
3.2.3 POWER SUPPLY CABLE CONNECTION 34
3.2.4 USB CONNECTION 35
3.2.5 F-THETA LENS PROTECTION CAP REMOVAL 36
4. USE AND OPERATIONS 37
4.1 TURNING ON SEQUENCE 37
x
5. ACCESSORIES 41
5.1 CONTROL BOX 41
5.2 POWER SUPPLY ULYXE™ FAMILY 42
5.3 REMOTE CAN DISPLAY 43
6. TECHNICAL SUPPORT 47
6.1 SEALS 47
6.2 MAINTENANCE 48
6.2.1 F-THETA SCAN LENS CLEANING PROCEDURE 48
6.3 TROUBLESHOOTING 49
6.3.1 LIST OF POSSIBLE MALFUNCTIONS 49
6.3.2 ERROR MESSAGES 51
6.4 PRODUCT SUPPORT AND CUSTOMER SERVICE 54
APPENDIX A: LABELS IDENTIFICATION 55
LABELS LOCATION 56
APPENDIX B: STANDARDS 57
LASER STANDARDS 57
CE COMPLIANCE 57
FCC COMPLIANCE 57
APPENDIX C: NOTE ABOUT LASER 58
LASER SAFETY 58
LASER RADIATION 59
ABSORPTION OF LASER RADIATION 60
CLASSIFICATION AND DANGER LEVEL 60
RADIATION VIEWING CONDITIONS 61
DIRECT VIEWING OF THE LASER BEAM 61
DIRECT VIEWING OF THE BEAM AFTER MIRROR REFLECTION 61
DIRECT VIEWING OF THE BEAM OUTPUT BY AN OPTICAL FIBER 61
DIRECT VIEWING OF THE BEAM AFTER FOCUSING 61
SCATTERED VIEWING OF THE BEAM AFTER FOCUSING 61
REAL O.R.N.D. DETERMINATION AND O.D. OF PROTECTION GOGGLES 62
EYES AND SKIN RISKS 64
GENERAL SAFETY REGULATIONS 64
COLLATERAL RISKS 64
APPENDIX D: MECHANICAL DRAWINGS 66
FIGURES 67
CONTENTS OF THE PACKAGING
11
1
1. CONTENTS OF THE PACKAGING
1.1 UNPACKING
When unpacking the marking system from the shipping carton you should:
Remove the documentation from the top of the marking system
Remove the box containing the accessories
Carefully remove the marking system from the packaging using both hands
Figure 2: Unpacking.
Before installing or operating the marking system, you should:
Inspect the shipping container for damage
Inspect the marking system for signs of damage
Confirm that the shipping carton contains all items on the shipping inventory list including any
accessories
Retain all packaging materials until the marking system has been inspected for completeness and damage,
and you have checked the operating performance. If anything is missing or defective, see chapter 6 for
contact details.
Ulyxe PL
TM
12
1
1.2 MAIN HARDWARE
Ulyxe PL F-Theta (except 1PWX-T0SV)
1.3 CABLE AND ACCESSORIES
Power supply cable
USB cable
RS232 cable
Aux Interlock connector
gold (*)
USB key
Control Box connector
User Manual
Test Report
Sample Test
* If this connector is used, the marking system works in DANGEROUS condition (MUTING DEVICE).
CONTENTS OF THE PACKAGING
13
1
1.4 TRANSPORT
The marking system can be easily lifted up and moved by a single person thanks to its compact size and
reduced weight.
Figure 3: Transport.
WARNING!
The Ulyxe PLis a delicate optical marking system, avoid damaging it with shock and vibrations.
1.5 ON MOISTURE CONDENSATION
If the marking system is brought directly from a cold to a warm location, moisture may condense inside or
outside the marking system. This moisture condensation may cause a malfunction of the marking system.
If moisture condensation occurs
Turn off the marking system and wait about 1 hour for the moisture to evaporate.
Note on moisture condensation
Moisture may condense when you bring the marking system from a cold place into a warm place (or vice
versa) or when you use the marking system in a humid place as shown below.
How to avoid moisture condensation
When you bring the marking system from a cold place into a warm place, put it in a plastic bag and seal it
tightly. Remove the bag when the air temperature inside the plastic bag has reached the ambient
temperature (after about 1 hour).
Ulyxe PL
TM
14
1
1.6 FIXING AND POSITIONING
The marking system need to be positioned in safety mode and fixed on an appropriate plan absolutely with
no vibrations.
Ulyxe PL
TM
is equipped with 4 threaded
holes and 2 fixing pins.
Screws M6
Fixing pins Ø5 H7
Figure 4: Fixing points.
Figure 5: Measures, distance threaded holes and fixing pins drivers.
WARNING!
It is very important to secure the marking system before you start marking the piece since improper
securing or positioning may cause serious damage. Do not secure the marking system in a way
other than the one described in the figure.
NOTE:
In order to prevent marking distortions, check for the absence of vibrations between marking system
and piece to be marked.
NOTE:
It is recommended to install the marking system on a micrometer positioning Z-axis system!
CONTENTS OF THE PACKAGING
15
1
1.7 INSTALLATION ENVIRONMENT
The marking system must be installed in a suitable environment in order to allow proper air flow passage and
correct housing of the cables.
Ulyxe PL
TM
is an air cooled marking system, an adequate air flow is necessary to guarantee its correct
cooling. Installation must not slow or stop the flow of air cooling. Moreover, do not install a heat source near.
Figure 6: Installation environment.
To obtain a good marking quality, and not to decrease life time, we recommended a ventilation or vacuum
system in a protection box to limit dust due to marking phase.
1.8 FUME / DUST EXTRACTOR
During marking process, dust and/or gas may be produced. It is important to use adequate fume extractor
and/or air filtration.
WARNING!
Marking PVC (or other plastic material) can cause the release of chlorine gas which can be harmful
to the laser operator and to the marking system itself. Always use adequate fume extractor during
PVC and plastic marking.
Ulyxe PL
TM
16
2
2. TECHNICAL SPECIFICATIONS
NOTE:
BEFORE INSTALLING AND USING THE LASER, READ CAREFULLY THE APPENDIXES.
WARNING!
Ulyxe PL
TM
is a CLASS 4 LASER PRODUCT and it is the responsibility of the OEM/system
integrator to provide the safety completeness to be ready-to-use.
2.1 TECHNICAL SPECIFICATION
MECHANICAL CHARACTERISTICS
Weight 7.8 Kg
Height * 123.5 mm
Width 145.6 mm
Depth 410 mm
IP Rating ** 21
* without F-Theta scan lens
** in horizontal position only
NOTE:
Refer to Datalogic’s website for detailed drawings.
TECHNICAL SPECIFICATIONS
17
2
STORAGE AND TRASPORTATION CONDITIONS
Storage temperature
-5° to 55°C (23° to 131°F)
Shock and vibrations The components are not designed to withstand shocks and vibrations
WARNING!
This product includes precision optical parts; avoid vibration and shocks: marking quality may deteriorate.
ENVIRONMENTAL OPERATING CONDITIONS
Environmental temperature
15°C to 35°C (59° to 95°F)
Humidity
< 90% without condensation
Altitude
< 1000 m
Suspended matter
< 3 mg/m
3
Pollution Degree
2
Overvoltage Category
II
ELECTRICAL POWER SUPPLY
Input Voltage
24V DC
Input Current 13 A max
Max Power
300 W
PERFORMANCE
LASER MARKER SOURCE (typical values @ 25°C)
Laser Type
Class 4 DPSSL (Diode Pumped Solid State Laser)
Average Power @ reference
Rep Rate (50kHz)
1
W 6.5
Pulse energy (max) @
reference Rep Rate (15kHz)
mJ 0.30
Central emission wavelength nm 1064
Repetition Rate
kHz
15 ÷ 200
Laser aiming beam
Class 2 <1mW @ 630-670nm
Focus aiming beam Class 2 <1mW @ 630-670nm
Cooling
Forced Air
Noise
dB(A)
< 70 @ 1 meter
OTHER
Marking Speed mm/s Up to 5000 mm/s
Char Marking Speed
2
char/s
Up to 275 char/s @ 2000 mm/s
Software Control
Lighter Suite
Communication 1x USB (type B), RS232, digital I/O
1
Without F-Theta
2
h char=1mm in Roman-S Level100% f=40kHz F-Theta160S on TESA label
Ulyxe PL
TM
18
2
2.2 DESCRIPTION OF THE LASER
MODULES
A description of the main parts of the marking system is provided here below:
Figure 7: Marking system view.
1) Status LED bar 7) Control Box connector
2) LED indicators 8) Aux Interlock connector
3) Main Switch with LED 9) USB port (type B)
4) Power supply connector 10) F-Theta Scan Lens
5) CAN connector 11) Focusing beam
6) RS232 port
TECHNICAL SPECIFICATIONS
19
2
2.3 MARKING AREA SPECIFICATION
Datalogic provides a wide range of F-Theta scan lenses to be attached to the scanning head to focus the
laser beam in flat Marking Field, in order to achieve high-resolution marking results.
These F-Theta scan lenses are available to best-match the object (i.e.: logo; string; 2D matrix; etc.) to be
marked with customer need, over the material processing, and fit the standard Datalogic Scanning Head;
further solutions about different models of lenses and scanning heads will be considered upon request.
The table below lists the standard F-Theta scan lenses currently available:
F-Theta Scan Lens diameter: M39
F-Theta Scan Lens
ƒ
= 100S
ƒ
= 160S
ƒ
= 254S
Working Distance (WD) mm 114 178 282
Marking Area (MA) mm
2
50 x 50 100 x 100 140 x 140
NOTE:
Definition of Marking Area: square marking field measured on black anodized aluminium plate.
WARNING!
This product was designed to use only certain configurations of F-Theta lens and marking field. If
your needs are not satisfied by current available F-Theta lens configurations please contact
Datalogic for a solution. The use of other F-Theta lenses or operation outside the specified marking
field for a certain F-Theta lens configuration can lead to damage of F-Theta lens, scanning head or
laser source. Such damage is not covered by warranty!
WARNING!
For each F-Theta lens configuration Datalogic recommends the use of certain adapter. This adapter
ensures that residual back reflections caused by F-Theta lens do not damage optics of the scanning
head. The removal of such adapter or its incorrect use (for example incomplete threading, use of
another F-Theta lens adapter, etc.) can lead to damage of the F-Theta lens, scanning head or laser
source. Such damage is not covered by warranty!
Ulyxe PL
TM
20
2
NOTE:
Working Distance is defined as the distance between the center of the marking area (defined
in the focal plane) and the last mechanical edge of the F-Theta Scan Lens. Refer to the
following figure.
WD: Working Distance
FD: Fixing Distance
MA: Marking Area
AB: Aiming beam
FB: Focusing beam
Figure 8: Marking area.
NOTE:
For systems equipped with standard F-Theta Scan Lens the focus condition is obtained by
matching the Aiming Beam with the Focusing beam.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68

Datalogic ULYXE FAMILY User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document