NOMA THM301M is a programmable thermostat that provides automatic temperature control for heating or air-conditioning systems. It features a large LCD display with backlight, real-time clock, and separate weekday/weekend programs with 4 programs per day. The thermostat allows you to set different temperatures for different times of the day, ensuring a comfortable indoor environment while saving energy. Additionally, it offers temporary override, hold function, fan control, and pre-comfort recovery system for added convenience and efficiency.

NOMA THM301M is a programmable thermostat that provides automatic temperature control for heating or air-conditioning systems. It features a large LCD display with backlight, real-time clock, and separate weekday/weekend programs with 4 programs per day. The thermostat allows you to set different temperatures for different times of the day, ensuring a comfortable indoor environment while saving energy. Additionally, it offers temporary override, hold function, fan control, and pre-comfort recovery system for added convenience and efficiency.

MODEL: THM301M - USER’S MANUAL (ENGLISH)
DATE: Oct 2, 2003
THM301M
Programmable
Thermostat
http://waterheatertimer.org/Woods-timers-and-manuals.html#Noma-Garrison
2
26
1
++
++
++
++
++
--
--
Back-Cover
Thermostat
A) ATTACH THERMOSTAT
SNAP HINGES AT
BOTTOM EDGE
B) ATTACH COVER
THM301M
- This thermostat requires two AA size batteries (included) to operate. Ensure the batteries
are installed.
- Select °C or °F before clock setting and programming. (Refer to page 24).
- The time and day must be set before use. Flip the protective cover to access the function
keys and switches.
- The backlight only comes ON in the dark. Any key press will turn the backlight ON for 8
seconds in the dark.
Features:
Large LCD display with backlight
Real-time clock showing day, hour and minute - in selectable 12 or 24 hour display format
Separate Weekday/Weekend programs with 4 programs per day
Separate Heat/Cool programs with built-in protection for the air-conditioner compressor
Display and set temperature in °C or °F
Interface with heating or air-conditioning systems for automatic temperature control
Protective Cover
Pull down the Protective Cover
SET
HEAT
COOL
HO
LD
AM
PM
Temperature
Weekday
AM/PM mode
Hour/Minute Setting
Program 1
Program 2
Program 3
Program 4
3
4
24
HEAT/COOL CONTROL
LCD DISPLAY
DISPLAY
UP
DOWN
FAN CONTROL
SET CLOCK
PROGRAM
AHEAD
RESET
HOLD
BACK
CURRENT
Function Key Descriptions
LCD Display
Set Time and Day
! Press SET CLOCK to start time setting. Only time will be shown. (Figure 1)
! Use AHEAD or BACK to set the current time.
! Press SET CLOCK again. Weekday will be shown. (Figure 2)
! Use AHEAD or BACK to set the current day.
! Press SET CLOCK again to exit.
25
Back-CoverBack-Cover
++ ++
++
++
--
--
+
+
+
+
5
6
22
23
+
+
-
-
HE
H
G
G
R
Y
W
+
_
Programs
This thermostat is equipped with separate programming for weekdays and weekends, with four
programs each.
Program 1: this is typically for the morning when you may prefer a warmer temperature.
Program 2: this is an energy-savings mode, for the time you are away from home. The setting can be
adjusted to minimize energy consumption.
Program 3: this is for the time you return home and want the house at a comfortable temperature,
typically warmer settings during winter and cooler settings during summer.
Program 4: this is a sleep mode. You may choose to set temperature for energy savings or comfort
as desired.
Note:
! The 4 programs for weekdays and the 4 programs for weekends are independent. You may set
them to the same or different time/temperature combination.
! Heating and Cooling modes also have separate programs.
HE AT COOL
WEEK DAY WEEK DAYWEEK END WEEK END
P1
P1
P2 P2
P3 P3
P4
P4
23
27
22
23
23
27
22
23
7:40a.m.
9:00a.m.
4:30p.m.
11:00p.m.
9:30a.m.
10:40a.m.
10:20p.m.
11:30p.m.
Below Is An Example Of A Programming Schedule :
P1 P122 22
7:30a.m.
9:00a.m.
P2
P2
16 16 9:00a.m. 11:30a.m.
P3
P3
21
18
4:30p.m.
4:00p.m.
P4 P4
21 20
10:40p.m.
8:00p.m.
7
8
Press the tabs to open
the thermostat.
20
21
Back-Cover
Wall
Through Hole
Wires
Wall
AM
SET
SET
HE AT
AM
SET
HE AT
AM
Wires
++
++
+ +
++
++
Back-Cover
Te r min a l s
Heating Program
! Slide the system switch to the HEAT position and press the PROGRAM key once, the P1 and
SET symbols will appear on the display. MO to FR symbol is shown indicating Weekday program
is being displayed. (Figure 3)
! Use AHEAD or BACK to select the desired start time for weekday program 1.
! Use UP or DOWN (on extreme right) to set the desired temperature.
! Temperature can be set in increments of 0.5°.
! Program time can be set in increments of 10 minutes.
! After setting correct time and temperature for program 1, press PROGRAM again to display
weekday program 2. Use same method to set the desired time and temperature for program 2.
! Repeat the procedures for weekday program 3 and 4, and weekend programs 1-4. (Figure 4)
! After complete setting of all 8 programs, press PROGRAM to return to normal display (SET
symbol will disappear). Leaving the thermostat without any keys pressed for 16 seconds while
setting will also return the display to normal.
Note:
! The PROGRAM key can also be used anytime to review all the set programs.
! To terminate the programming sequence at anytime, press DISPLAY key.
Mounting The Thermostat Back-Cover
! The back-cover should be mounted horizontally
with the terminals on the left side.
! Thread the existing wiring through the big center
hole from the back and set the back-cover
horizontally on the wall.
! Select two appropriate mounting holes and mark
the locations with a pencil. If necessary, use a level
to make sure the thermostat is leveled.
! Remove the back-cover from the wall and drill two
3/16 inch holes in the marked screw positions.
Insert the wall-anchors into the holes completely. If
necessary, use a hammer to tap-in lightly.
! Mount the back-cover with the two screws to the
wall. Make sure the metal terminals are on the left
side.
Connecting The Wires To The Terminals
Tip: Press and hold the AHEAD/BACK or UP/DOWN key to move the numbers quickly.
Figure 3
Weekday
Hour/Minute Setting
Temperature
Temperature
Program 1
Figure 4
Weekend
Hour/Minute Setting
Program 1
Figure 2
SET
Figure 1
LEVEL
+
+
+
+
+
+
+
+
+
+
Mark the locations
with a pencil
Back-Cover
10
18
19
9
Replacing Old Thermostat
Note: Do not operate the cooling system when outside temperature is below 10 C (50 F) to avoid
damaging the compressor.
! Test the system to make sure that your heating and cooling are working properly before
installation. If either does not work, contact your local heating/air-conditioning dealer to fix the
problem before installation.
! TURN OFF POWER to system at the furnace, or at the fuse/circuit breaker panel.
! Carefully unpack your new thermostat and mounting plate; save package of screws, instructions
and receipt.
! Remove cover from old thermostat. If it does not snap off when pulled firmly from the bottom,
check for a screw used to secure the cover.
! Loosen screws holding thermostat to the wall and lift away the thermostat.
! Disconnect wires from old thermostat or sub-base. As you disconnect each wire, use masking
tape to label it with the old terminal designation. If there are only two wires, they don't need to be
labeled. If there is an extra wire that is not connected to your old thermostat, then you won't need
to connect it to the new thermostat.
! Take care not to let the wires fall back into the wall or let the ends of the wires touch one another.
! The wires are usually designated 'R', 'G', 'Y', 'W', 'Rc', 'C'.
°°
Cooling Programs
Slide the system switch to the COOL position and repeat the programming as you would for the
Heating Programs.
Temporary Override
To change the temperature temporarily, press UP or DOWN to set the desired temperature. The
thermostat will return to the regular program at the next scheduled program time.
Note: The thermostat has an automatic delay function to protect the heating and cooling systems
from undesired on/off sequences. Sometimes there will be a delay of several minutes before the
thermostat will activate the system.
Hold
! This feature is to hold the thermostat at a constant temperature and disable the set programs.
! Press HOLD once and use UP or DOWN button to set the desired hold temperature. HOLD
symbol will appear to indicate that the Hold function is active.
! To cancel Hold function, press HOLD again. The current scheduled program number (P1 ~ P4).
will appear on the screen and the HOLD symbol will disappear. The thermostat will return to the
programmed temperature.
Check Current Programs
Press either UP or DOWN once to check the current programmed temperature setting without
changing it. You may also use the CURRENT key for this function.
Room Temperature
! Press DISPLAY anytime to check the current temperature.
Fan Control Switch
! If your heating/cooling system is equipped with a fan, it will be turned on automatically when
heating or cooling is activated.
! To turn on the fan manually, set the Fan ON/AUTO switch to the ON position, the fan will run
Choosing Location For New Thermostat
Thermostat should be mounted:
! Approximately 5 ft (1.5m) from floor.
! Near or in a frequently used room, preferably on an inside partitioning wall.
! On a section of wall without pipes or duct-work
Thermostat should NOT be mounted:
! Near a window, on an outside wall, or next to a door leading outside.
! Exposed to direct light or heat from a lamp, sun, fireplace, or other temperature-radiating
objects which may cause false readings.
! Near or in direct airflow from supply registers and return-air grilles.
! Near concealed pipes and chimneys
! In areas with poor air circulation, such as behind a door or in an alcove.
After choosing a location for the new thermostat, you may arrange to have a heating contractor
install the control wiring for you.
11
12
16
17
- AA SIZE +
- AA SIZE +
System Type
Gas - Standing Pilot
Gas - Electronic Ignition
Gas - Fire Boiler
Gas - Millivolt System
Oil - Fire Boilers
Oil - Fire Furnace
Electric Furnace
Electric Air Conditioner
Baseboard Electric Heater (120/240V)
Heat Pump/Multi- Stage equipment
Compatibility
Generally, equipment with low voltage control is compatible with the THM301M thermostat. For
details on compatibility of your particular equipment, please call our technical assistance line.
continuously to improve air ventilation. To return to automatic control, set the switch to the AUTO
position.
Heat/Cool Control Switch
! If this switch is on the OFF position, both the heating and cooling systems are turned off, and all
programs and settings will be disabled.
! Slide the switch to HEAT or COOL to control the heating or air-conditioning system.
! The symbols HEAT or COOL on the display will be flashing when heating or cooling is activated.
Pre-Comfort Recovery
This thermostat is equipped with a ‘Pre-Comfort Recovery’ system that will activate the heating or
cooling in advance of the actual set program time so that the room will be at the desired temperature
at the start of the comfort program time.
It is normal for the system to be activated earlier (up to ½ hour for heating and one hour for cooling)
than the actual set program time.
12/24 Hour Display Format
Press both AHEAD and BACK keys together at the same time to change the time display from 12
hour format to 24 hour format (e.g. 8:00pm / 20:00) and vice versa.
Changing Batteries
When all digits on the LCD display flashes, it indicates that the batteries are running low and have to
be replaced. However, it is recommended for the batteries to be replaced every year even if display is
not flashing yet. To replace batteries:
! Set the thermostat system switch to the OFF position and have the new batteries on-hand.
! Open the thermostat by pressing on the 2 tabs on the top.
! Remove the old batteries and install new ones quickly.
! Close the thermostat to its original position.
If new batteries are inserted within 20 seconds of removing the old ones, the existing time and
programs will not be cleared. Otherwise, the display will show 9:00a.m. and the thermostat will have
to be re-programmed.
Installation
The following tools may be required for installation:
See below to select a suitable place for the new thermostat installation. And refer to "Replacing Old
Thermostat" section to replace old thermostat.
Compatible with THM301M
Yes
Yes
Yes
Yes
Yes
Some models
Some models
No
No
Two AA size batteries (included)
Wire Stripper/Cutter
(If necessary, to strip the wires)
Level
(If necessary, to level the thermostat)
Masking Tape
(To wrap the exposed wires temporarily and labeling
the disconnected wires)
Hand Power Drill with a 3/16 inch bit
( If necessary, to drill holes on the wall )
Cross (Phillips) screwdriver
Yes
* Not compatible with any 120/240 volt circuit
14
15
13
Installation
Manual
Reset
If the thermostat shows an abnormal display or if you want to clear all existing programs, use a
pointed object to press the ‘R’ key. Time and programs will need to be set again after a Reset.
IF…. THEN….
Display will not come on Check if batteries are installed correctly.
Check if batteries are fresh and of correct type.
Press the RESET key.
Entire display flashes Batteries are low. Replace with new batteries.
Air-conditioning will not come on System switch is on the HEAT or OFF position.
(symbol COOL not flashing) Current temperature is lower than set temperature. Press CURRENT to check current program.
Air-conditioning has been turned off within 5 minutes, and automatic delay has been activated to
protect the compressor.
Air-conditioning will not come on Check if the air-conditioning main switch is turned on;
(symbol COOL flashing) it may have been turned off.
Heating will not come on System switch is on the COOL or OFF position.
(HEAT symbol not flashing) Current temperature is higher than set temperature. Press CURRENT to check current program.
Heating will not come on Check if the furnace switch and/or pilot flame is turned on; it may have been turned off.
(HEAT symbol flashing) Allow some time for the heater to heat up and the fan to activate. Most heaters will heat up the
system for a short while before warm air can be ventilated by the fan.
HE/HG jumper inside the thermostat is not set correctly. Check installation manual.
The current temperature is It is common for the setting and the displayed temperature to differ occasionally. The thermostat
different from the scheduled will be activated if this difference persists.
temperature There is a temporary override by the user.
The system is on HOLD. Press HOLD once to resume normal setting.
TROUBLESHOOTING GUIDE
THM301M Installation Manual
Introduction
This thermostat can replace common residential thermostats and it is designed for use with most
electric, oil or gas heating and air-conditioning systems that use low voltage control. Please see
compatibility chart for more details.
! 4 weekday programs and 4 weekend programs
! Display temperature with 0.5° resolution
! Only two AA size batteries required (included)
! Built-in protection timing for the air-condition compressor
If you have any questions concerning the installation or programming of the thermostat, please call
1-888-468-6876 for our technical assistance.
Specification
Model: THM301M
Number of Programs: Weekly 5/2 day programs with 4 programs per day
Temperature measurement range: 1
Program setting range: 5
Storage temperature range: -20 to 50°C (-4
Battery: 2 x AA size batteries
°C - 37.5°C (34°F - 99.5°F)
°C - 35°C (41°F - 95°F)
°C °F - 122°F)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

NOMA THM301M User manual

Category
Thermostats
Type
User manual

NOMA THM301M is a programmable thermostat that provides automatic temperature control for heating or air-conditioning systems. It features a large LCD display with backlight, real-time clock, and separate weekday/weekend programs with 4 programs per day. The thermostat allows you to set different temperatures for different times of the day, ensuring a comfortable indoor environment while saving energy. Additionally, it offers temporary override, hold function, fan control, and pre-comfort recovery system for added convenience and efficiency.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI