TOA TS-771 User manual

Category
Microphones
Type
User manual

This manual is also suitable for

OPERATING INSTRUCTIONS
CONFERENCE SYSTEM TS-770 SERIES
TS-770
TS-771 TS-772 TS-775
Thank you for purchasing TOA's Conference system.
Please carefully follow the instructions in this manual to ensure long, trouble-free use of your equipment.
TS-770 (CENTRAL UNIT)
TS-771 (CHAIRMAN UNIT)
TS-772 (DELEGATE UNIT)
TS-773 (MICROPHONE)
TS-774 (MICROPHONE)
TS-775 (REMOTE DELEGATE INTERFACE UNIT)
YR-770-2M (2 m EXTENSION CORD)
YR-770-10M (10 m EXTENSION CORD)
2
TABLE OF CONTENTS
1. IMPORTANT SAFETY INSTRUCTIONS ..................................................... 3
2. SAFETY PRECAUTIONS ................................................................................. 4
3. GENERAL DESCRIPTION .............................................................................. 6
4. FEATURES ........................................................................................................... 6
5. NOMENCLATURE AND FUNCTIONS
5.1. TS-770 Central Unit ........................................................................................... 7
5.2. TS-771 Chairman Unit and TS-772 Delegate Unit ............................................. 9
5.3. TS-775 Remote Delegate Interface Unit .......................................................... 11
6. OPERATING CHAIRMAN AND DELEGATE UNITS
6.1. Making Speech ................................................................................................ 12
6.2. Making Priority Speech (Chairman Unit TS-771 Only) ..................................... 13
7. HOLDING REMOTE CONFERENCES
7.1. Remote Conference Procedures ...................................................................... 14
7.2. Speech Operation When the Remote Delegate Interface Unit
Is Set to AUTO Mode ....................................................................................... 14
7.3. Speech Operation When the Remote Delegate Interface Unit
Is Set to MANUAL Mode .................................................................................. 15
7.4. Setting Examples ............................................................................................. 15
8. FUNCTION SETTINGS
8.1. Speaker Restriction Function
8.1.1. Setting procedure ................................................................................... 16
8.1.2. Restricted number of simultaneously operable Delegate units
and each conference unit's operation .................................................... 16
8.2. Automatic Mic-Off Function .............................................................................. 17
8.3 All Mic-On Function ........................................................................................... 17
9. RECORDING
9.1. Recording with the Central Unit ....................................................................... 18
9.2. Recording with the Chairman Unit or Delegate Unit ........................................ 18
10. INSTALLATION AND CONNECTION
10.1. Connection Example ...................................................................................... 19
10.2. Installation Procedures ................................................................................... 20
10.3. Basic System Installation and Adjustment
10.3.1. Connecting the Chairman and Delegate units to the Central unit ...... 21
10.3.2. Setting functions and adjusting Chairman and Delegate units
sound output volume .......................................................................... 23
11. IF USING MULTIPLE CENTRAL UNITS: .................................................. 25
12. WHEN HOLDING REMOTE CONFERENCES: ...................................... 26
13. BLOCK DIAGRAMS
13.1. TS-770 Central Unit ....................................................................................... 29
13.2. TS-771 Chairman Unit ................................................................................... 29
13.3. TS-772 Delegate Unit ..................................................................................... 30
13.4. TS-775 Remote Delegate Interface Unit ........................................................ 30
14. SPECIFICATIONS
14.1. TS-770 Central Unit ....................................................................................... 31
14.2. TS-771 Chairman Unit and TS-772 Delegate Unit ......................................... 31
14.3. TS-773 and TS-774 Microphones .................................................................. 32
14.4. TS-775 Remote Delegate Interface Unit ........................................................ 32
14.5. YR-770-2M 2 m Extension Cord and YR-770-10M 10 m Extension Cord ..... 32
3
1. IMPORTANT SAFETY INSTRUCTIONS
Read these instructions.
Keep these instructions.
Heed all warnings.
Follow all instructions.
Do not use this apparatus near water.
Clean only with dry cloth.
Do not block any ventilation openings. Install in accordance with the manufacturer's instructions.
Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including
amplifiers) that produce heat.
• Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades
with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide
blade or the third prong is provided for your safety. If the provided plug does not fit into your outlet, consult
an electrician for replacement of the obsolete outlet.
Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and
the point where they exit from the apparatus.
Only use attachments/accessories specified by the manufacturer.
• Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer,
or sold with the apparatus. When a cart is used, use caution when moving the
cart/apparatus combination to avoid injury from tip-over.
Unplug this apparatus during lightning storms or when unused for long periods of time.
Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been
damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have
fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or
has been dropped.
4
When Installing the Unit
Do not expose the unit to rain or an environment
where it may be splashed by water or other liquids,
as doing so may result in fire or electric shock.
• Use the unit only with the voltage specified on the
unit. Using a voltage higher than that which is
specified may result in fire or electric shock. (TS-
770 only)
• Do not cut, kink, otherwise damage nor modify the
power supply cord. In addition, avoid using the
power cord in close proximity to heaters, and never
place heavy objects -- including the unit itself -- on
the power cord, as doing so may result in fire or
electric shock. (TS-770 only)
Avoid installing or mounting the unit in unstable
locations, such as on a rickety table or a slanted
surface. Doing so may result in the unit falling
down and causing personal injury and/or property
damage.
Since the unit is designed for in-door use, do not
install it outdoors. If installed outdoors, the aging of
parts causes the unit to fall off, resulting in personal
injury. Also, when it gets wet with rain, there is a
danger of electric shock.
When the Unit is in Use
Should the following irregularity be found during
use, immediately switch off the power, disconnect
the power supply plug from the AC outlet and
contact your nearest TOA dealer. Make no further
attempt to operate the unit in this condition as this
may cause fire or electric shock.
· If you detect smoke or a strange smell coming
from the unit.
· If water or any metallic object gets into the unit
· If the unit falls, or the unit case breaks
· If the power supply cord is damaged (exposure of
the core, disconnection, etc.) (TS-770 only)
· If it is malfunctioning (no tone sounds.)
• To prevent a fire or electric shock, never open nor
remove the unit case as there are high voltage
components inside the unit. Refer all servicing to
qualified service personnel.
Do not place cups, bowls, or other containers of
liquid or metallic objects on top of the unit. If they
accidentally spill into the unit, this may cause a fire
or electric shock.
Do not insert nor drop metallic objects or
flammable materials in the ventilation slots of the
unit's cover as this may result in fire or electric
shock.
Do not touch a power supply plug during thunder
and lightning, as this may result in electric shock.
(TS-770 only)
The apparatus shall be connected to a mains
socket outlet with a protective earthing connection.
(TS-770 only)
The socket-outlet shall be installed near the
equipment and the plug (disconnecting device)
shall be easily accessible. (TS-770 only)
2. SAFETY PRECAUTIONS
Before installation or use, be sure to carefully read all the instructions in this section for correct and safe
operation.
• Be sure to follow all the precautionary instructions in this section, which contain important warnings and/or
cautions regarding safety.
After reading, keep this manual handy for future reference.
Safety Symbol and Message Conventions
Safety symbols and messages described below are used in this manual to prevent bodily injury and property
damage which could result from mishandling. Before operating your product, read this manual first and
understand the safety symbols and messages so you are thoroughly aware of the potential safety hazards.
WARNING
Indicates a potentially hazardous situation which, if mishandled, could
result in death or serious personal injury.
Indicates a potentially hazardous situation which, if mishandled, could
result in moderate or minor personal injury, and/or property damage.
WARNING
CAUTION
5
CAUTION
When Installing the Unit
Never plug in nor remove the power supply plug
with wet hands, as doing so may cause electric
shock. (TS-770 only)
When unplugging the power supply cord, be sure
to grasp the power supply plug; never pull on the
cord itself. Operating the unit with a damaged
power supply cord may cause a fire or electric
shock. (TS-770 only)
When moving the unit, be sure to remove its power
supply cord from the wall outlet. Moving the unit
with the power cord connected to the outlet may
cause damage to the power cord, resulting in fire or
electric shock. When removing the power cord, be
sure to hold its plug to pull. (TS-770 only)
Do not block the ventilation slots in the unit's cover.
Doing so may cause heat to build up inside the unit
and result in fire. Also, periodically clean the
ventilation slots of dust. (TS-770 only)
Avoid installing the unit in humid or dusty locations,
in locations exposed to the direct sunlight, near the
heaters, or in locations generating sooty smoke or
steam as doing otherwise may result in fire or
electric shock.
When the Unit is in Use
Contact your TOA dealer as to the cleaning. If dust
is allowed to accumulate in the unit over a long
period of time, a fire or damage to the unit may
result. (TS-770 only)
• If dust accumulates on the power supply plug or in
the wall AC outlet, a fire may result. Clean it
periodically. In addition, insert the plug in the wall
outlet securely. (TS-770 only)
• Switch off the power, and unplug the power supply
plug from the AC outlet for safety purposes when
cleaning or leaving the unit unused for 10 days or
more. Doing otherwise may cause a fire or electric
shock. (TS-770 only)
The lighting flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user
to the presence of uninsulated "dangerous voltage" within the product's enclosure that may be of
sufficient magnitude to constitute a risk of electric shock to persons.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of
important operation and maintenance (servicing) instruction in the literature accompanying the
appliance.
6
3. GENERAL DESCRIPTION
The TS-770 Series conference system is designed for quick and easy installation and storage.
The system can be installed by merely connecting conference units* to the TS-770 Central unit.
The use of the Remote Delegate Interface unit permits a party in remote location to participate in the
conference.
* Collective name of the following 3 models: TS-771 Chairman Unit, TS-772 Delegate Unit, and TS-775
Remote Delegate Interface Unit.
4. FEATURES
• Conference speech can be amplified by simply connecting the Chairman and Delegate units to the Central
unit.
Connecting the Remote Delegate Interface unit to the system allows conferences to be held between remote
locations via telephone lines or PCs.
Up to 70 conference units can be connected per Central unit. (35 units per line x 2 lines.)
Up to 3 Central units and up to 210 conference units can be connected per system.
Optional 2-meter and 10-meter extension cables allow wiring suitable to local installation conditions.
Either the TS-773 or TS-774 Microphone can be used with the TS-771 Chairman unit and the TS-772
Delegate unit.
• Because the microphone for both the Chairman and Delegate units is detachable, both units can be stored
without taking up much space.
Test function allows easy confirmation of connections between conference units.
The number of simultaneously operable Delegate units can be limited using the Speaker Restriction
function. (Can be set to 0, 1, 3 or 6 units.)
Even if the speaker forgets to turn off his or her microphone after speech completion, the Automatic Mic-Off
function automatically switches off the microphone after a preset interval elapses. (Can be set to OFF, 20 or
40 seconds.)
Conference contents can be recorded using a recording equipment.
All Mic-On function allows conferences to be held without requiring talk key operation. (A dedicated function
for conference recording.)
7
CENTRAL UNIT TS-770
1
2 3 4 5 6
7 8 9
10
5. NOMENCLATURE AND FUNCTIONS
5.1. TS-770 Central Unit
[Front]
1. Power indicator [POWER]
Lights when the power switch (11) on the rear
panel is set to the ON position.
2. Microphone volume control [MIC]
Adjusts the volume of the microphone connected
to the microphone input jack (7).
3. AUX volume control [AUX]
Adjusts the volume of equipment connected to
AUX input jack (8).
4. Line volume control [LINE]
Adjusts the volume of the conference unit's built-in
speaker.
5. Speaker restriction switch [MIC LIMITER]
Sets the number of delegate units that can be
used simultaneously.
6. Automatic mic-off setting switch [TIME OUT]
It is possible to set the conference unit's
microphone to be automatically turned off after
speech completion.
7. Mic input jack [MIC]
Connects to a microphone.
(600 Ω, –60 dB*, unbalanced)
8. AUX input jack [AUX]
Connects to a CD or cassette deck.
(10 kΩ, –20 dB*, unbalanced)
9. Test/All Mic-On Switch [TEST/MIC ON]
Setting this switch to the ON position turns on
the microphones of all conference units. This
switch is intended for testing purposes during
installation, as well as for open conferences in
which speech can be made freely from any
conference unit.
10. Test/All Mic-On Indicator
Lights when the Test/All Mic-On switch is set to
the ON position.
* 0 dB = 1 V
8
12 13 14 15 16 17
11 18 19 20 21
[Rear]
11. Power switch [POWER]
Power is switched on and off with each
depression of this switch.
12. Expansion Switch [EXPANSION/MAIN]
Used when expanding the Central unit.
(Equipped with a lock mechanism.) Set this
switch to the EXPANSION position if expanded.
13. Expansion IN/OUT terminals [EXT 1/2]
Connect to the Central unit(s) to be expanded.
14. LINE 1 connection terminal [LINE 1]
Connects to the conference unit. Up to 35
conference units can be connected per line.
15. LINE 2 connection terminal [LINE 2]
Connects to the conference unit. Up to 35
conference units can be connected per line.
16. Recording output terminal [REC OUT]
(Phone jack)
Connects to an Alternating cassette recorder,
etc. (10 kΩ, –20 dB*, unbalanced)
17. Recording output terminals [REC OUT]
(RCA jack)
Connect to a recording machine.
(10 kΩ, –20 dB*, unbalanced)
18. AC inlet
Connects to the supplied power cord.
19. Equalizer insertion input terminal
[EQUALIZER IN]
Connects to the output terminal of equalizer.
(10 kΩ, –20 dB*, unbalanced)
20. Equalizer insertion output terminal
[EQUALIZER OUT]
Connects to the input terminal of equalizer.
(10 kΩ, –20 dB*, unbalanced)
21. Equalizer insertion switch
[EQUALIZER ON/OFF]
Set to the ON position when using the equalizer.
* 0 dB = 1 V
9
TS-771
PRIORITY TALK
TS-772
TALK
1
2
3
4
5 6
1
2
3
4
6
5.2. TS-771 Chairman Unit and TS-772 Delegate Unit
[TS-771 Top] [TS-772 Top]
1. Line connection cord
Connect this cord to the Line Connection terminal
of the Central unit or that of the next preceding
linked conference unit.
2. Microphone connection connector
Connects to the TS-773 or TS-774 Microphone.
3. Speaker
Outputs other speakers' voices. Adjust the volume
with the TS-770 Central unit's line volume control.
The built-in speaker is temporarily disabled while
speech is made using this unit.
4. Microphone in-use indicator
Lights when the microphone can be used.
5. Priority key [PRIORITY] (TS-771 only)
While this key is pressed, the microphone in-use
indicator remains lit, allowing priority speech to go
through. In this case, no other conference units
can be used. Pressing this key causes a single
tone chime to sound at the remaining conference
units.
6. Talk key [TALK]
Press this key to speak. The microphone in-use
indicator lights. Press this key again to turn off the
microphone. The microphone in-use indicator
extinguishes.
10
[TS-771/TS-772 Side]
7 8
7. Volume control
Adjusts the sound volume from the
Recording/Headphone Output Terminal.
Note
Use the volume control of the TS-770 Central unit
to adjust the sound output volume from the
internal speaker (3).
8. Recording/Headphone output terminals
[HEADPHONES]
Connect recording equipment or headphones to
these terminals. No sound is output from the
internal speaker (3) while this terminal is in use.
[TS-771/TS-772 Rear]
9
10
9. Line connection terminal [LINE]
Connect the following linked conference unit's
line connection cord to this terminal.
10. Control output terminal
[CONTROL OUTPUT]
This terminal is an open collector output
interlocked with the Microphone in-use indicator,
and is enabled when in speech mode.
(24 V DC, Max. 50 mA)
11
5.3. TS-775 Remote Delegate Interface Unit
[Front]
1
2 3 4 5 6 7 8 9
1. Modular jack [HANDSET MODULAR]
Used to connect a telephone equipped with a
handset using modular connectors.
* Detach the handset from the telephone and
connect the Remote Delegate Interface unit to
the telephone instead.
2. Handset selector switch [HANDSET TYPE]
Set this switch to either the A or B position
depending on the type of telephone handset.
3. Microphone input terminal [INPUT –50 dBV]
Connect this terminal to the PC's headphone
output.
4. Speaker output terminal [OUTPUT –40 dBV]
Connect this terminal to the PC's microphone
input.
5. Microphone input volume control [INPUT]
Adjusts the microphone input volume.
6. Speaker output volume control [OUTPUT]
Adjusts the speaker output volume.
7. Speech Indicator
Lights when a remote party is allowed to speak.
8. Auto/Manual selector switch [AUTO/MANUAL]
Setting this switch to the AUTO position permits
the remote party to speak without requiring Talk
key operation.
The MANUAL position only permits the party to
speak when the Talk key is pressed.
9. Talk key [TALK]
Used to enable speech when the Auto/Manual
Selector switch is set to the MANUAL position.
Speech is alternately enabled and disabled with
each press of this key.
[Rear]
10 11 12
10. Line connection cord
Connect this cord to the Central unit or to the
next preceding linked conference unit.
11. Line connection terminal [LINE]
Connect this terminal to the following linked
conference unit.
12. Control output terminal
[CONTROL OUTPUT]
Output is closed ("make") when in speech mode.
(24 V DC, Max. 50 mA)
12
6. OPERATING CHAIRMAN AND DELEGATE UNITS
This section explains how to operate these units when the All Mic-On function is set to OFF (default setting).
When this function is set to ON, speakers can talk anytime from any conference unit with no need to operate
any switches or keys.
To enable or disable this function, use the Test/All Mic-On switch on the Central unit. (Refer to p. 17.)
6.1. Making Speech
Step 1. Press the TALK key once.
The microphone in-use indicator lights, and the
microphone turns on.
Notes
No sound is output from the internal speaker of the
operated unit while the Microphone in-use indicator
remains lit. However, audio signal is output from the
Recording/Headphone output terminal.
While the Chairman unit is in priority speech mode
(see page 13), other unit's microphones do not turn on
even if their Talk keys are pressed.
The microphones of some Delegate units may not turn
on even if their Talk keys are pressed, depending on
the setting of the Speaker Restriction function (see
page 16).
Step 2. Speak into the microphone.
Step 3. Press the Talk key again after speech completion.
The Microphone in-use indicator extinguishes and sound
is audible from the operated unit's speaker.
[Example: TS-772 Delegate unit]
TS-772
TALK
Microphone in-use indicator: Lights.
TS-772
TALK
Microphone in-use indicator: Extinguishes.
13
6.2. Making Priority Speech (Chairman Unit TS-771 Only)
Holding down the priority key on the Chairman unit gives that unit speech priority and allows it to interrupt
other delegate units.
Step 1. Press the Priority key.
The microphone in-use indicator lights, and the microphone
turns on. Pressing this key causes a single tone chime to
sound at the remaining conference units.
Note
No sound is output from the internal speaker of the
operated unit while the Microphone in-use indicator remains
lit. However, audio signal is output from the
Recording/Headphone output terminal.
Step 2. Speak while holding down the Priority key.
No delegate units can be used while the Priority key is
pressed.
Step 3. The microphone in-use indicator extinguishes, turning on
the built-in speaker.
Notes
In the system employing 2 or 3 chairman units, even while 1 unit is making priority speech, other chairman
unit(s) can also make priority speech by pressing the Priority key although a single-tone chime is not
sounded.
Any previous speech that has been interrupted by the priority speech is not restored even after priority
speech completion. Press the Talk key again, and make a speech after microphone in-use indicator lights.
When the Remote Delegate Interface unit is set to Auto mode, if the Chairman unit's priority key is pressed
while a remote party is speaking, the Chairman unit can speak but cannot interrupt the remote party's
speech in progress.
Microphone in-use indicator: Lights.
TS-771
PRIORITY TALK
14
7. HOLDING REMOTE CONFERENCES
Using the TS-775 Remote Delegate Interface unit instead of the Delegate unit permits a remote party to
participate in conferences via telephone or PC.
7.1. Remote Conference Procedures
Step 1. Set the telephones or PCs in both the conference room and remote locations to conversation mode,
then connect the telephone or PC in the conference room to the Remote Delegate Interface unit.
For details, refer to p. 26.
Step 2. Set the Remote Delegate unit's Auto/Manual Selector switch to "AUTO" or "MANUAL," whichever is
suitable for the type of conference. Depending on the selected switch position, the method of enabling
speech differs.
However, when the Central unit's All Mic-On function is set to ON, any conference unit can speak at
any time without requiring any key operation.
Auto/Manual Selector switch
( : AUTO)
TS-775
Remote Delegate Interface Unit
7.2. Speech Operation When the Remote Delegate Interface Unit Is Set to AUTO Mode
Speak while nobody else is speaking.
The speech indicator lights.
TS-775
Remote Delegate Interface Unit
[Conference room] [Remote location]
Shift to the "AUTO."
If speech is initiated while nobody else is speaking, the Remote Delegate Interface unit detects the speaker's
audio signal and automatically switches to speech mode (the unit's Speech indicator lights). After speech is
completed, the speech mode is reset and the Speech indicator extinguishes.
Regardless of the setting of the Speaker Restriction function (see page 16), provided nobody else is speaking,
the speaker's audio signal is detected and the speaker is allowed to speak.
Speech made through the Remote Delegate Interface unit is not interrupted even if the Chairman unit's priority
key (see the next page) is pressed during the speech.
Note
This unit is disabled for speech if another party is already speaking.
15
7.3. Speech Operation When the Remote Delegate Interface Unit Is Set to MANUAL Mode
Speak while the Talk key is
turned on.
The speech indicator lights.
Shift to the "MANUAL."
Press the Talk key.
TS-775
Remote Delegate Interface Unit
[Conference room] [Remote location]
The remote party is permitted to speak when the Remote Delegate Interface unit's Talk key is pressed, and
cannot speak when the key is pressed again.
Set the unit to MANUAL mode to enable the chairman or other parties in the conference room to prevent a
remote party from freely speaking. In the MANUAL mode, the number of simultaneously operable Delegate
units can be limited (Speaker Restriction function - see page 16).
7.4. Setting Examples
Step 1. Select MANUAL mode to extinguish the speech indicator when it is desirable to prohibit remote
conference participants from speaking.
Step 2. When a remote participant requests permission to speak, press the Talk key to enable speech or shift
the AUTO/MANUAL Selector switch to the AUTO position so that the participant may speak at any
time. Select either position according to the circumstances.
Speaking is prohibited.
Speech indicator is extinguished.
Shift to the "MANUAL."
TS-775
Remote Delegate Interface Unit
[Remote location][Conference room]
Make speech.
The speech indicator lights if the Talk key is pressed.
Shift to the "MANUAL."
Press the Talk key.
TS-775
[Conference room]
[Remote location]
The Speech indicator lights if a remote participant speaks.
Shift to the "AUTO."
or
16
8. FUNCTION SETTINGS
8.1. Speaker Restriction Function
8.1.1. Setting procedure
Using the TS-770 Central Unit's speaker restriction switch, set the number of simultaneously-usable delegate
units (TS-772). Set the switch to 0, 1, 3, or 6 depending on the type of conference.
Delegate units cannot speak if the number is set to "0." (Chairman Priority mode)
TS-770 Central Unit
Speaker restriction switch
(Factory default: 6)
CENTRAL UNIT TS-770
Note
When multiple Central units are connected, different settings cannot be applied for each unit. If settings differ
among these Central units, only the setting of the unit with its Expansion switch set to MAIN takes effect.
8.1.2. Restricted number of simultaneously operable Delegate units and each conference unit's operation
Shown below is the relationship between the Speaker Restriction function and each conference unit's speech
capability.
[Chairman unit]
Chairman units can speak at any time regardless of the setting of the Speaker Restriction function.
[Delegate unit]
Up to the set number of Delegate units can speak simultaneously.
When the full set number of Delegate units are in use (their microphones have been turned on), no
microphones of other Delegate units can be turned on, even if their Talk keys are pressed.
[Remote Delegate Interface unit]
Speech capability differs depending on the Auto/Manual selector switch setting.
• Auto position: A remote party can speak regardless of the setting of the Speaker Restriction function,
provided another conference unit is not currently in use.
Manual position: The Remote Delegate Interface unit is also recognized as one of the Delegate units. Up to
the set number of Delegate units, inclusive of the Remote Delegate Interface unit, can be
simultaneously used.
17
8.2. Automatic Mic-Off Function
Using the Automatic mic-off setting switch of the TS-770 Central Unit, the automatic mic-off function can be
set. Whenever a break in speech exceeds a specified period of time, the Central unit presumes speech
completion and automatically turns off the microphone. Delegate unit's microphone turns off after the preset
period of time even if a speaker forgets to turn it off after use.
The break time can be set for either 20 (20s position) or 40 (40s position) seconds. Set the switch to OFF if
this function is unnecessary.
TS-770 Central Unit
Automatic mic-off setting switch
(Factory default: OFF)
CENTRAL UNIT TS-770
8.3 All Mic-On Function
It is possible to turn on the microphones of all connected conference units by setting the Central unit's All Mic-
On switch to ON. In this event, no sound is output from Chairman and Delegate unit's internal speakers,
however audio signals are output from their Recording/Headphone Output terminals.
All conference units can speak at any time without requiring Talk key operation, regardless of the Speaker
Restriction function setting. The All Mic-On function is especially useful when wishing to record small
conferences or broadcast conference contents to other areas.
Note
When the All Mic-On function is enabled and it is desirable to have a remote party speak by way of the
Remote Delegate Interface unit, be sure to set the unit's Auto/Manual Selector switch to MANUAL. The party
cannot speak if the switch is set to AUTO.
TS-770 Central Unit
All Mic-On switch (Factory preset: OFF)
All Mic-On indicator
CENTRAL UNIT TS-770
Notes
When the automatic mic-off function is selected, any break in speech exceeding the preset time during
speech will automatically turn off the microphone. Therefore, for conferences in which long breaks in speech
are expected, set the automatic mic-off setting switch to the OFF position.
In areas with high levels of background noise, the Central unit may mistake the noise to be speech and the
automatic mic-off function will not operate correctly. In such cases, this function should be disabled by
placing the switch in the OFF position.
In the system employing 2 or 3 Central units, it is not possible to operate the units with each different setting.
Perform the same setting for all connected Central units.
18
9. RECORDING
The contents of the conference can be recorded by connecting an Alternate Cassette Recorder or other
recording equipment to the TS-770 Central Unit, TS-771 Chairman Unit, or TS-772 Delegate Unit.
9.1. Recording with the Central Unit
Step 1. Connect the recording output on the rear panel of the TS-770 Central Unit to the recorder's recording
input.
There are 2 types of recording output terminals: one is of a phone jack and the other is of RCA jacks.
Select either type of jack according to equipment to be connected.
Note
Prepare the connection cables separately.
Phone plug
Pin plug
or
To the recorder's recording
input terminal
To the recorder's recording
input terminal
Recording output terminals
(RCA jacks)
Recording output terminal
(Phone jack)
TS-770 Central Unit
Step 2. Connect a set of headphones into the recorder's monitor output to confirm that the contents of the
conference are being recorded correctly.
If the recording device is equipped with a recording level control, adjust it to an appropriate recording
level.
For use of recording device, refer to the instruction manual supplied with the device.
9.2. Recording with the Chairman Unit or Delegate Unit
Using the Recording/Headphone Output terminals on the side panel, recordings can be made in the same
manner used for the Central unit.
Recording/Headphone output terminals
TS-771 Chairman unit or
TS-772 Delegate unit
Mini plug
To the recorder's recording
input terminal
To 1 or 2
Notes
If either of Recording/Headphone jacks 1 and 2 is used, no sound is output from the unit's speaker.
Sound volume from the recording output of the Chairman and Delegate units can be adjusted using the
Central unit's Line Volume control. Setting the line volume control to the minimum position makes it
impossible to record from the recording output of the Chairman and Delegate units. When wishing to record
conference contents without amplifying the sound output from the Chairman and Delegate unit speakers,
use the Central unit's Recording Output terminals.
19
10. INSTALLATION AND CONNECTION
10.1. Connection Example
TS-770 Central unit
TS-770 Central unit
TS-770 Central unit
TS-771 Chairman unit
TS-771 Chairman unit
TS-771 Chairman unit
PC
PC
TS-772 Delegate units
TS-772 Delegate unit
TS-772 Delegate unit
Telephone body
Telephone handset
Handset modular
connector
TS-775 Remote Delegate
Interface unit
TS-775 Remote Delegate
Interface unit
PABX
C/O
Internet
20
10.2. Installation Procedures
1. Connect the Delegate units to the Central unit (see page 9).
2. Perform function settings for the Central unit, and volume adjustment, etc. for
the Chairman and Delegate units
(see page 21).
4. Make connections between Central units (see page 25).
3. Repeat Steps 1 and 2 above for each Central unit (see page 25).
5. Establish speech connections with remote participants through PCs or
telephones, then adjust their sound volume
(see page 26).
Basic System Installation
If using multiple Central units:
If using the Remote Delegate Interface
units (remote conferencing):
(1 Central unit and up to 70 Delegate units)
(Up to 3 Central Units and up to 210 conference units)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32

TOA TS-771 User manual

Category
Microphones
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI