  • Hello! I am an AI chatbot trained to assist you with the Taylor Technologies K-1505 Owner's manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
COMPONENTS:
1 x 5225 Instruction
1 x 9198B Sample Tube, Graduated (25 mL) w/ cap & blue dot, plastic
1 x R-0614-C Hardness Reagent A, 2 oz w/ blue cap, DB
1 x R-0615-I Hardness Reagent B, 10 g w/ blue dot
1 x R-0683-C Hardness Reagent, 2 oz, DB
1 x R-0806-C Hardness Reagent, 2 oz, DB
TO ORDER REPLACEMENT PARTS AND REAGENTS CALL TOLL-FREE
800-TEST KIT (800-837-8548).
PROCEDURE:
CAREFULLY READ AND FOLLOW PRECAUTIONS ON REAGENT LABELS.
KEEP REAGENTS AWAY FROM CHILDREN.
NOTE: When dispensing reagents from dropper bottles, always hold bottle in a
vertical position.
Total Hardness Test
For 1 drop = 2 ppm Calcium Carbonate
1.Rinseandll25mLsampletube(#9198B)to25mLmarkwithwatertobetested
(Fig.1).
NOTE: Forresultsingrainspergallon(gpg),llto14.6mLmark.
2.Add5dropsR-0614HardnessReagentA.Swirltomix.
3.Add1dipperR-0615HardnessReagentB.Swirluntildissolved.Samplewillturn
red(Fig.2)ifhardnessispresent.
4.AddR-0806HardnessReagentdropwise,swirlingandcountingaftereachdrop,
untilcolorchangesfromredtoblue(Fig.3).
DROP TEST
TOTAL HARDNESS (1 drop = 2 or 10 ppm)
5.MultiplydropsofR-0806HardnessReagentby2.Recordaspartspermillion(ppm)
totalhardnessascalciumcarbonate.
NOTE: For14.6mLsample,multiplydropsofR-0806HardnessReagentby0.2.
Recordasgrainspergallon(gpg)totalhardnessascalciumcarbonate.
For 1 drop = 10 ppm Calcium Carbonate
1.Rinseandll25mLsampletube(#9198B)to25mLmarkwithwatertobetested
(Fig.1).
NOTE: Forresultsingrainspergallon(gpg),llto14.6mLmark.
2.Add5dropsR-0614HardnessReagentA.Swirltomix.
3.Add1dipperR-0615HardnessReagentB.Swirluntildissolved.Samplewillturn
red(Fig.2)ifhardnessispresent.
4.AddR-0683HardnessReagentdropwise,swirlingandcountingaftereachdrop,
untilcolorchangesfromredtoblue(Fig.3).
5.MultiplydropsofR-0683HardnessReagentby10.Recordaspartspermillion
(ppm)totalhardnessascalciumcarbonate.
NOTE: For14.6mLsample,recorddropsofR-0683HardnessReagentasgrains
pergallon(gpg)totalhardnessascalciumcarbonate.
Fig. 1
Fig. 2
Fig. 3
Instr. #5225
31LovetonCircle,Sparks,MD21152U.S.A.
800-TESTKIT(837-8548)•410-472-4340
www.taylortechnologies.com 8/16
/