Raymarine Remote Keypad User manual

  • Hello! I am an AI chatbot trained to assist you with the Raymarine Remote Keypad User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
SeaTalk
Remote
Keypad
Owner’s
Handbook
Document number: 81073_5
Date: 1February 2003
073_5cov.p65 1/22/2003, 10:11 AM1
© Copyright Raymarine Limited 2003
073_5cov.p65 1/22/2003, 10:11 AM2
SeaTalk Remote Keypad Owner’s Handbook
i
Contents
Package Contents ................................................................ iii
Chapter 1: Operation ............................................................. 1
1.1 Introduction ................................................................. 1
EMC conformance ...................................................... 3
1.2 Basic operation ........................................................... 3
Key functions .............................................................. 3
Remote indicators........................................................ 3
1.3 General information .................................................... 4
Chapter 2: Maintenance & Fault Finding ............................ 5
2.1 Maintenance ................................................................ 5
Servicing and safety .................................................... 5
Cabling ........................................................................ 5
Assistance .................................................................... 5
2.2 Fault finding ................................................................ 5
Chapter 3 Installation ........................................................... 7
3.1 Planning your installation ........................................... 7
EMC installation guidelines ........................................ 7
Suppression Ferrites .............................................. 8
Connections to other equipment ............................ 8
Tools ............................................................................ 8
Site requirements ......................................................... 8
3.2 Procedure .................................................................... 9
Connecting to SeaTalk............................................... 10
Autopilot connections ............................................... 10
3.3 Check before going to sea ......................................... 11
EMC conformance .................................................... 11
073_5con.p65 1/22/2003, 10:18 AM1
ii SeaTalk Remote Keypad Owners Handbook
Chapter 4: Setup................................................................... 13
2.1 Introduction to instrument grouping ......................... 13
2.2 Grouping standard instruments ................................. 13
2.2 Grouping ST80 MaxiView instruments .................... 16
Chapter 5: Specification ...................................................... 19
073_5con.p65 1/22/2003, 10:18 AM2
SeaTalk Remote Keypad Owners Handbook
iii
Package Contents
1. Remote keypad 5. SeaTalk cable
2. Thumb nuts (2) 6. Installation template.
3. Fixing studs (2) 7. Owner’s Handbook (this book)
4. Sun cover 8. Quick Reference Guide
D4545-3
32
5
1
4
8
7
6
073_5con.p65 1/22/2003, 10:18 AM3
iv SeaTalk Remote Keypad Owners Handbook
073_5con.p65 1/22/2003, 10:18 AM4
Chapter 1: Operation
1
Chapter 1: Operation
1.1 Introduction
The SeaTalk Remote Keypad enables you to remotely operate the
following instruments on a SeaTalk system:
Standard (110 mm x 110 mm) ST60 instruments.
Standard and MaxiView ST80 instruments.
The Remote Keypad has:
A group of six keys, used to control standard instruments.
A group of four keys, used to control ST80 MaxiView instruments.
D1945-6
Controls
for MaxiView
instruments
Controls
for standard
instruments
SeaTalk Remote Keypad
Instruments can be organised in groups, up to a maximum of eight
groups each of eight instruments, to allow specified groups to be
operated from different Remote Keypads (see Chapter 4, Setup). For
optimum system flexibility, you can also use more than one Remote
Keypads to operate any group of instruments.
Typical ways of using instrument groups are shown in the following
illustration.
073_5txt.p65 1/22/2003, 10:07 AM1
2 SeaTalk Remote Keypad Owner’s Handbook
Examples of typical uses for instrument groups
Port
steering
station
SeaTalk link
Starboard
steering
station
120 120
6060
9090
3030
Port and starboard steering
stations on a catamaran
Flybridge and cabin steering
stations on a power vessel
Cabin
steering
station
Flybridge
steering
station
D4536-2
SeaTalk link
073_5txt.p65 1/22/2003, 10:07 AM2
Chapter 1: Operation
3
EMC conformance
All Raymarine equipment and accessories are designed to the best
industry standards for use in the leisure marine environment.
Their design and manufacture conforms to the appropriate
Electromagnetic Compatibility (EMC) standards, but correct
installation is required to ensure that performance is not compromised.
1.2 Basic operation
Key functions
The following illustration shows the functions assigned to each key or
key sequence.
Select required ST80 MaxiView
Cycle chapters on selected ST80 MaxiView
Cycle pages in selected ST80 MaxiView chapter
Select required standard instrument
These four keys duplicate the functions
of the respective keys on the selected
standard instrument.
D2353-4
Key functions for normal operation
Remote indicators
When the or key is pressed, each individual instrument in the
associated instrument group is selected in turn, on successive key
presses. As each instrument is selected, it displays a remote indication,
during which time you can control it from the Remote Keypad. The
manner in which the remote indication is displayed depends on the type
of instrument:
On ST80 instruments, the display changes to reverse video (white
on black).
On ST60 digital instruments, a REMOTE indicator is displayed.
073_5txt.p65 1/22/2003, 10:07 AM3
4 SeaTalk Remote Keypad Owners Handbook
On ST60 analogue instruments, either one or both of the TRUE /MAG
or TRUE/APP indicators flash on and off.
After 8 seconds, the remote indicator is removed, and the ability to
remotely control the instrument is suspended, until you again press a
remote key to re-display the remote indication.
D2354-2
ST60
ST80
Typical remote indications
1.3 General information
The Remote Keypad beeps when a key is pressed.
The Remote Keypad is permanently illuminated to facilitate
operation in all lighting conditions. The level of brightness is
determined by the system illumination setting.
073_5txt.p65 1/22/2003, 10:07 AM4
Chapter 2: Maintenance & Fault Finding 5
Chapter 2: Maintenance & Fault Finding
2.1 Maintenance
All Raymarine equipment and accessories are designed to the best
industry standards for use in the leisure marine environment.
Servicing and safety
Raymarine equipment should be serviced only by authorised
Raymarine service engineers. They will ensure that service
procedures and replacement parts used will not affect performance.
There are no user serviceable parts in any Raymarine product.
Some products generate high voltages, and so never handle the
cables/connectors when power is being supplied to the equipment.
Always report any EMC related problem to your nearest Raymarine
dealer. We will use any such information to improve our quality
standards.
Cabling
Periodically examine all cables for chafing or other damage to the outer
shield. When necessary, replace and secure damaged cables.
Assistance
For advice or further information regarding this product, please contact
the Raymarine Product Support Department or your own National
Distributor.
2.2 Fault finding
All Raymarine products are subjected to a comprehensive test
procedure prior to packing and shipping. In the unlikely event that a
fault does occur with your Remote Keypad, use the following check list
to help identify and rectify the problem.
073_5txt.p65 1/22/2003, 10:07 AM5
6 SeaTalk Remote Keypad Owners Handbook
Keypad does not operate
Make sure the cable connecting the keypad to SeaTalk is connected
properly.
Make sure the cable is not damaged. Replace the cable if it is
damaged.
Instruments do not operate in a logical sequence
Instruments and keypad are not grouped. Refer to Chapter 4, Setup
chapter for grouping details.
All instruments operate at the same time
Instruments are not grouped. Refer to Chapter 4, Setup chapter for
grouping details.
Instruments cannot be remotely controlled
Not in a keypad group. Refer to Chapter 4, Setup chapter for
grouping details.
073_5txt.p65 1/22/2003, 10:07 AM6
Chapter 3: Installation 7
Chapter 3 Installation
3.1 Planning your installation
Before installing your SeaTalk Remote Keypad, spend some time
considering the best position. It should be fitted in a position which
gives optimum accessibility while at the same time satisfying the EMC
installation guidelines and the other Site requirements, described
below. Ensure that you have all the necessary components, templates
and tools for the job.
EMC installation guidelines
All Raymarine equipment and accessories are designed to the best
industry standards for use in the leisure marine environment.
Their design and manufacture conforms to the appropriate
Electromagnetic Compatibility (EMC) standards, but correct
installation is required to ensure that performance is not compromised.
Although every effort has been taken to ensure that they will perform
under all conditions, it is important to understand what factors could
affect the operation of the product.
To minimise the risk of operating problems:
All Raymarine equipment and cables connected to it should be:
At least 1 m (3 feet) from any equipment transmitting or cables
carrying radio signals, e.g. VHF radios, cables and antennas. In
the case of SSB radios, the distance should be increased to
2 m (7 ft).
More than 2 m (7 ft) from the path of a radar beam. A radar
beam can normally be assumed to spread 20 degrees above and
below the radiating element.
The equipment should be supplied from a different battery than the
one used for engine start. Voltage drops below 10 V in the power
supply to our products can cause the equipment to reset. This will
not damage the equipment, but will cause the loss of some
information and can change the operating mode.
Raymarine specified cables should be used at all times. Cutting and
rejoining these cables can compromise EMC performance and so
should be avoided unless doing so is detailed in the installation
manual.
073_5txt.p65 1/22/2003, 10:07 AM7
8 SeaTalk Remote Keypad Owners Handbook
If a suppression ferrite is attached to a cable, this ferrite should not
be removed. If the ferrite has to be removed during installation it
must be reassembled in the same position.
Suppression Ferrites
The following illustration shows the typical range of suppression
ferrites fitted to Raymarine equipment. Always use the ferrites
specified by Raymarine.
Connections to other equipment
If your Raymarine equipment is going to be connected to other
equipment using a cable not supplied by Raymarine, a suppression
ferrite MUST always be fitted to the cable close to the Raymarine unit.
Tools
5 mm twist drill 45 mm (1.77 in) tank cutter/hole saw
Power drill Screwdrivers
Site requirements
The SeaTalk Remote Keypad must be installed:
In a flat, smooth location.
At least 230 mm (9 in) away from your vessels steering compass
and 500 mm (20 in) from radio equipment.
So there is sufficient space behind the facia to accommodate the
cables, fixing studs and thumb nuts.
If you intend siting the keypad next to an instrument or another
keypad, make sure that they are separated by at least 3 mm to enable
sun covers to be fitted, when required.
073_5txt.p65 1/22/2003, 10:07 AM8
Chapter 3: Installation 9
D2756-6
3.2 Procedure
Install your SeaTalk Remote Keypad as follows:
1. Apply the fitting template (supplied near the rear of this handbook)
to the intended location, using adhesive tape if necessary. Mark the
centres for the fixing stud clearance holes (2) and the aperture (3)
for the rear of the keypad.
D4546-3
Mounting the SeaTalk Remote Keypad
123456
073_5txt.p65 1/22/2003, 10:07 AM9
10 SeaTalk Remote Keypad Owners Handbook
2. Drill the two 5 mm (3/16 in) fixing stud clearance holes (2).
3. Cut out the 45 mm aperture (3), then remove the template.
4. Remove any rough edges from the bulkhead.
5. Peel off the protective sheet from the self-adhesive gasket (4) then
stick the gasket into position on the rear of the instrument.
6. Screw the two fixing studs (1) into the keypad.
7 Offer up the assembled keypad, gasket and studs to the bulkhead,
and plug the SeaTalk cables (6) into the back of the keypad as
shown.
8. Fit the keypad to the bulkhead, by inserting the fixing studs (1)
through the drilled holes (2) and securing with the thumb nuts (5).
Tighten the thumb nuts BY HAND, until the keypad is secure. Do
NOT use a wrench to tighten the nuts.
Connecting to SeaTalk
Connect your SeaTalk Remote Keypad to SeaTalk by plugging the
supplied SeaTalk cable into a convenient 3-Way SeaTalk connector
block.
D2352-5
Daisy-chain or extension cable
Remote Keypad connected to the SeaTalk bus
Power cable
3-way SeaTalk connector block
Autopilot connections
When the associated instrument system is configured for use with an
autopilot, a SeaTalk link between the instrumentation and the course
computer is required.
073_5txt.p65 1/22/2003, 10:07 AM10
Chapter 3: Installation 11
D2423-2
Active Compass
Course Computer
Autopilot Keypad
Masterview
SeaTalk
3-Way SeaTalk
Connector Block
Autopilot connections
If you require extension cables, please refer to the display head
installation chapter for a list of options.
3.3 Check before going to sea
EMC conformance
Always check the installation before going to sea to make sure that it
is not affected by radio transmissions, engine starting etc.
In some installations, it may not be possible to prevent the
equipment from being affected by external influences. In general
this will not damage the equipment but can lead to it resetting, or
momentarily may result in faulty operation.
073_5txt.p65 1/22/2003, 10:07 AM11
12 SeaTalk Remote Keypad Owners Handbook
073_5txt.p65 1/22/2003, 10:07 AM12
Chapter 4: Setup 13
Chapter 4: Setup
4.1 Introduction to instrument grouping
When a Remote Keypad is first installed, all instruments respond
simultaneously to the Remote Keypad button presses.
Although this simultaneous operation may be suitable for installations
with a small number of instruments, in larger installations, it is often
more convenient to organise instruments into groups.
Once a Remote Keypad and instruments have been grouped, the up and
down keys are used to select individual instruments. An instrument can
then be operated remotely using the appropriate Remote Keypad
buttons.
You can create up to eight standard instrument and eight ST80
MaxiView instrument groups:
Each group can have up to eight instruments.
Each group must have at least one Remote Keypad grouped to it.
Each Remote Keypad can only be grouped with one ST80
MaxiView and one standard instrument group.
Each instrument in a group has a unique alphanumeric identity (e.g.
A1, where A defines the group and 1 the instrument sequence
number within the group). Standard instruments are assigned group
letters from A to H. ST80 MaxiView instruments are assigned group
letters from J to Q. Ungrouped instruments have a dash (-) in place
of a group letter.
The instrument sequence number range is from 1 to 8.
4.2 Grouping standard instruments
To define a group of standard (110 mm) instruments:
1. At any Remote Keypad, press and hold the lower and
keys for 4 seconds. All the standard instruments will enter group
setup mode, with the selected instrument showing a remote
indication, as follows:
On selected ST80 instruments, the display shows reverse video
(white on black).
073_5txt.p65 1/24/2003, 10:25 AM13
14 SeaTalk Remote Keypad Owners Handbook
On selected ST60 digital instruments, a REMOTE indicator is
displayed.
On selected ST60 analogue instruments, either one or both of
the TRUE /MAG or TRUE/APP indicators flash on and off.
Group setup indications - identifying instruments
D2357-3
Typical ST60 digital
Typical ST60 analogue
ST60 Tridata
Typical ST80 digital
Typical ST80 analogue
2. Use the or key to select a instrument to be the first in the
group.
3. Referring to the following illustration, use the appropriate keys to
allocate a group letter and sequence number to the selected
instrument. When the instrument has been properly identified, it
should display its group letter and sequence number, e.g. A2.
Select the required standard instrument
Select either:
group setup or
sequence number setup
(toggle action)
Press to set the identity you want, either:
A to H for group identity, or
1 to 8 for instrument sequence number
D2358-4
Note: In group setup mode, all standard instruments are selectable.
073_5txt.p65 1/22/2003, 10:07 AM14
/