9
CoolAir SPX1200I Installation
• The supplied assembly parts must not be modified during installation.
• The ventilation slots (grill) may not be covered (minimum distance from other
attachment parts: 10 cm).
• You can connect the unit to the battery via the lorry's terminal block or
directly. The terminal block is to be preferred for the connection. On some
vehicles, larger consumers connected to the terminal block are switched off
after a short while if the power requirement is too high. Ask your vehicle
manufacturer for the specifications of the terminal block.
• Observe the body manufacturer's guidelines with regard to installation of the
unit and its electrical connection.
6.3 Determining the installation position
The system's installation position must meet the following criteria:
• All maintenance work must be easy to perform.
• Sufficient space must be available for the refrigerant line.
• The refrigerant line must be long enough (approx. 2.1 m) for connection of
the condenser and evaporator unit. The line must not be routed under
tension (fig. 3).
• The fastening surface should be as flat as possible. Use spacer sleeves for
uneven surfaces. If spacer sleeves are used, appropriately longer fastening
screws with sufficient tensile strength (not included in the assembly set) must
then be used.
I
NOTE
The fastening screws M6 x 40 mm included are designed for use with the
spacer sleeves, l = 25 mm, (e.g. MAN TGX).
The fastening screws M6 x 110 mm included are designed for use with the
spacer sleeves, l = 40 mm, (e.g. Volvo FH as of construction year 2013) (two
spacer sleeves for each screw).
By combining the spacer sleeves, different distances between the rear wall of
the cab and inner trim can be achieved.
The screw overhang beyond the nut must not exceed 15 mm.
If spacer sleeves are not to be used or if other ones are to be used, the fastening
screws have to then be adapted to match them. Otherwise the unit housing
may be damaged.