CAME WA01 Owner's manual

Type
Owner's manual

CAME WA01 is an automated home control system that provides users with a range of features to enhance convenience and security in their homes. With its ability to interface with the WI08 digital electronic card, users can control various aspects of their home automation system. The device operates on a 120-230V AC power supply and has a maximum power load of 5A 230V AC/24V DC for resistive loads and 1.5A 230V AC for inductive loads.

CAME WA01 is an automated home control system that provides users with a range of features to enhance convenience and security in their homes. With its ability to interface with the WI08 digital electronic card, users can control various aspects of their home automation system. The device operates on a 120-230V AC power supply and has a maximum power load of 5A 230V AC/24V DC for resistive loads and 1.5A 230V AC for inductive loads.

WAVE
AUTOMATED HOME CONTROL SYSTEM
32
32
°
C
10:55
10
:55
INSTALLATION MANUAL
WA01
2
The data and information shown in this manual may be changed by CAME cancelli automatici s.p.a. at any time without prior warning
EN
INDEX
1. Legend of symbols.......................................................3
2. Intended use and restrictions.......................................3
2.1 Intended use........................................................3
2.2 Usage restrictions...............................................3
3. Regulatory framework.................................................4
4. Description..................................................................4
4.1 230V a.c. Control system...................................4
4.2 Technical Data....................................................4
4.3 General Description............................................5
5. Installation..................................................................6
5.1 Preliminary checks.............................................6
5.2 Tools and materials.............................................6
5.3 Dimensions, centre distance and securing holes.7
5.4 Introduction to the functioning logic...................8
5.5 Connecting cables...............................................9
5.6 Wall mounting...................................................10
6. Programming............................................................11
6.1 Description of commands and the display.11
6.2 Browsing the menu............................................12
6.3 Menu Structure - Main.......................................13
6.3.1 Menu-Settings-Language.........................14
6.3.2 Menu -Settings-Temperature...................15
6.3.3 Menu -Settings-Screensaver....................15
6.4 Menu-Modify user.............................................16
6.5 Menu-New user..................................................18
6.6 Menu-Remove user............................................19
6.7 Menu-TX Radio..................................................20
6.8 Menu-Timer.......................................................21
6.9 Menu-Alarm clock.............................................22
6.10 Menu-Thermostat............................................23
6.11 Menu-Clock......................................................24
6.12 Menu-Key functions.........................................24
6.13 Menu-Password...............................................25
7.Maintenance........................................................28
8.Phasing out and Disposal.....................................28
9.Manufacturer’s statement....................................29
3
EN
The data and information shown in this manual may be changed by CAME cancelli automatici s.p.a. at any time without prior warning
Automated home control system featuring a stand alone function – will interface with the WI08 digital, electronic
card.
This symbol tells you to read the section with particular care.
This symbol tells you that the sections concern safety issues.
This symbol tells you what to say to the end-users.
2.1 Intended use
2.2 Restrictions
Secure the apparatus in areas free from accidental impacts.
2 Intended use and restrictions
1 Legend of symbols
“IMPORTANT INSTALLATION, SAFETY INSTRUCTIONS”
“CAUTION: IMPROPER INSTALLATION MAY CAUSE SERIOUS DAMAGE, FOLLOW ALL INSTALLATION INSTRUCTIONS CAREFULLY”
THIS MANUAL IS ONLY FOR PROFESSIONAL OR QUALIFIED INSTALLERS
4
The data and information shown in this manual may be changed by CAME cancelli automatici s.p.a. at any time without prior warning
EN
This product complies with the following standards: EN 60730-1, EN 60950-1.
3 Reference Standards
Control panel
Power supply: 120/230V - 50÷60 Hz.
Max Power: 30 mA AC
Power draw when idle: 20 mA AC
Max power load of accessories: 5A 230V AC/24V DC (resistant) ; 1,5A 230V AC (inductive).
Protection rating: IP40
Isolation class: II
Temperature variance: ± 1°C
Material: ABS Support /PC/ - PA6 – PMMA Plate
Radio Frequency: 433.92 MHz
Estimated radio range: 30m (inside building)
Operating temperature:
#
#
Home automation control system powered by 120-230V a.c.; 50÷60 frequency.
CAME projects and produces entirely in Italy.
It fi ts all embedded door wall boxes.
4.2 Technical features
4.1 230V a.c. control system
4 Description
5
EN
The data and information shown in this manual may be changed by CAME cancelli automatici s.p.a. at any time without prior warning
,,
6!#
#/- /54
!"'.$ #.#./
32
32
°C
10:55
10:55
4.3 General description
1
2
4
3
5
6
7
1- Temperature gauge sensor
2- Command keypad
3- Display
4- Hole cover-plate
5- Power terminals
6- Terminals for connecting the WI08
7- Automation connection terminals (relays).
6
The data and information shown in this manual may be changed by CAME cancelli automatici s.p.a. at any time without prior warning
EN
Before installing, do the following:
Make sure that the sport where the device will be secured is protected from impacts. Secure the device using
suitable screws, plugs, and so on for the type of surface;
Make sure you have a suitable omnipolar cut-off device with contacts more than 3 mm apart, and independent
(sectioned off) power supply;
Make sure that any connections inside the case (that provide continuance to the protective circuit) be fi tted
with extra insulation as compared to the other conductive parts inside;
Make sure you have suitable tubing and conduits for the electrical cables to pass through and be protected against
mechanical damage;
5 .1 Preliminary checks
5.2 Tools and materials
Make sure you have all the tools and materials you will need for the installation at hand to work in total safety and
compliance with the current standards and regulations. The following figure illustrates the minimum equipment
needed by the installer.
5 Installation
7
EN
The data and information shown in this manual may be changed by CAME cancelli automatici s.p.a. at any time without prior warning
5.3 Dimensions, centre distances and securing holes
117
80
46.5
9.5
37
75.5
50
83.5
38
8
The data and information shown in this manual may be changed by CAME cancelli automatici s.p.a. at any time without prior warning
EN
5.4 Introduction to the functioning logic
Transponder
RS 485
Radio
Relay
IN OUT
Keys
Thermostat
Timer
IN
Wave allows you to associate an “IN” command such as:
Transponder, keys, thermostat and timer to an “OUT” instruction such as a radio code or a relay plug or to the
connection of another device (only for the WI08).
For example: you may control the garden lights with either the timer or keys and transponder.
9
EN
The data and information shown in this manual may be changed by CAME cancelli automatici s.p.a. at any time without prior warning
,,
6!#
#/- /54
!"'.$ #.#./
5.5 Connecting cables
230 V. a.c. power source
Relay socket
Serial connection sockets for WI08 card
10
The data and information shown in this manual may be changed by CAME cancelli automatici s.p.a. at any time without prior warning
EN
5.6 Wall mounting
1 2
3
11
EN
The data and information shown in this manual may be changed by CAME cancelli automatici s.p.a. at any time without prior warning
32
32
°C
10:55
10:55
The ENTER key
32 C
10:55
is for :
- Accessing the menu
- Confi rming and memorising the set value
The ESC key
32 C
10:55
is for :
- Exiting the menu
- Cancelling changes
- Go back in the editable menus
The key
32 C
10:55
32 C
10:55
are for:
- Shift from one menu item to another
- Increase and decrease a value
6 Programming
6.1 Description of commands and display
MENU
MENU
Setup
Setup
Edit User
Edit User
New User
New User
Delete User
Delete User
Status indicator (shows which menu you are browsing)
}
Selected item
Menu items: can be selected using arrow keys
32 C
10:55
Set Thermostat
Set Timer
Set Alarm clock
Active local relay
12
The data and information shown in this manual may be changed by CAME cancelli automatici s.p.a. at any time without prior warning
EN
32
32
°C
10:55
10:55
6.2 Browsing Menu
To enter the main
menu, keep the
ENTER key pressed
MENU
MENU
Setup
Setup
Edit User
Edit User
New User
New User
Delete User
Delete User
To chose the selected item, shift
using the ARROWS
MENU
Setup
Edit User
New User
Delete User
CONFIRM (YES)
CONFIRM (YES)
New User
New User
?
MENU
MENU
Setup
Setup
Edit User
Edit User
New User
Delete User
Delete User
CONFIRM (NO)
CONFIRM (NO)
New User
New User
?
To enter the sub-
menu, press the
ENTER key
To select, shift using the
ARROWS
Pressing the Esc key
takes you to the pre-
vious menu
CONFIRM (YES)
CONFIRM (YES)
New User
New User
?
Press ENTER to con-
fi r m
13
EN
The data and information shown in this manual may be changed by CAME cancelli automatici s.p.a. at any time without prior warning
6.3 Structure - Main Menu
Setup
Setup
Edit User
Edit User
New User
New User
Delete User
Delete User
TX Radio
TX Radio
Timer
Timer
Alarm
Alarm
Thermostat
Thermostat
Clock
Clock
Key Function
Key Function
Password
Password
Pressing the Enter key for a few seconds takes you into
the main menu (main level)
To shift from one item to another use the ARROWS
Press Enter to confi rm (this takes you to the second level)
Pressing Esc takes
you back to the
previous menu
14
The data and information shown in this manual may be changed by CAME cancelli automatici s.p.a. at any time without prior warning
EN
6.3.1 Menu – Settings – Language
ENGLISH
ENGLISH
FRENCH
FRENCH
GERMAN
GERMAN
SPANISH
SPANISH
NEDERLANDS
NEDERLANDS
TemperatureTemperature
Screen SaverScreen Saver
Setup
Setup
ITALIAN
ITALIAN
32 C
10:55
Language
Language
32 C
10:55
Edit User
Edit User
New User
New User
32 C
10:55
Choose the selected language and confi rm by pressing ENTER
15
EN
The data and information shown in this manual may be changed by CAME cancelli automatici s.p.a. at any time without prior warning
6.3.2 Menu – Settings – Temperature
6.3.3 Menu – Settings – Screensaver
Select the unit of measure for the temperature and confi rm by pressing ENTER
Temperature
Temperature
Screen SaverScreen Saver
Celsius
Celsius
LanguageLanguage
Fahrenheit
Fahrenheit
Setup
Setup
32 C
10:55
Edit User
Edit User
New User
New User
32 C
10:55
32 C
10:55
Select the screensaver and conform by pressing ENTER
TemperatureTemperature
Screen Saver
Screen Saver
Setup
Setup
Hour
Hour
32 C
10:55
LanguageLanguage
32 C
10:55
Date
Date
Logo CAME
Logo CAME
32 C
10:55
Edit User
Edit User
New User
New User
16
The data and information shown in this manual may be changed by CAME cancelli automatici s.p.a. at any time without prior warning
EN
SELECT USER
SELECT USER
New n..
New n..
New00
New00
2
New001
New001
6.4 Menu – Change user
Edit User
Edit User
OUTPUT
OUTPUT
NAME
NAME
CODE
CODE
Change user: Allows you to change the details of a single user (code, name, kind of exit)
SetupSetup
Edit User
Edit User
New User
New User
32 C
10:55
32 C
10:55
Select the use to change by
using the arrows. Confi rm by
pressing ENTER
New001
New001
32 C
10:55
32 C
10:55
In the single user
change menu, you
may choose the
parameters to change
using the arrows.
Once you have chosen
which to change
confi rm by pressing
Enter
17
EN
The data and information shown in this manual may be changed by CAME cancelli automatici s.p.a. at any time without prior warning
CODE
CODE
Edit User
Edit User
New001
New001
NEW CODE
NEW CODE
NAME
NAME
Edit User
Edit User
new001
new001
new 001
n
Press ENTER
32 C
10:55
to :
- To go to the next letter that needs changing
- Confi rm the changes (keeping it pressed)
Press ESC
32 C
10:55
to :
- Go back to the previous letter
- Go back to the previous level, without saving any
changes (keeping it pressed)
Keep the arrow keys pressed
32 C
10:55
32 C
10:55
to:
- Change letter
Selecting the NAME item
takes you into the user
change area.
6.4 Change user - Menu
32 C
10:55
32 C
10:55
You may memorise a transponder code and
associate it to a chosen user, by approaching
the card to the Wave device which enables code
recognition within 10 s
18
The data and information shown in this manual may be changed by CAME cancelli automatici s.p.a. at any time without prior warning
EN
OUTPUT
OUTPUT
new001
new001
OUTPUT
OUTPUT
LOCAL RELAY
LOCAL RELAY
Edit User
Edit User
To select the output to
associate shift using the
arrow keys and confi rm by
pressing Enter
6.4 Change user - Menu
EXIT associates a command to a user. It can be of two types: the fi rst is defi ned as local exit and is a physical
socket (NO, NC); the second is a radio socket
(up to four different ones can be inserted).
6.5 New user - Menu
CONFIRM (NO)
CONFIRM (NO)
Neu User
Neu User
?
New user : to create a new user
shift using the arrow keys to YES
and confi rm by pressing Enter.
The change menu is activated
automatically. To set the date
see chapter 6.4.
Edit User
Edit User
New User
New User
32 C
10:55
Delete User
Delete User
32 C
10:55
32 C
10:55
19
EN
The data and information shown in this manual may be changed by CAME cancelli automatici s.p.a. at any time without prior warning
6.6 Eliminate User - Menu
CONFIRM (NO)
CONFIRM (NO)
Delete User
Delete User
New002
New002
?
Eliminate User: Eliminates a present user.
SELECT USER
SELECT USER
New n..
New n..
New00
New00
2
New001
New001
SetupSetup
Edit User
Edit User
New User
New User
32 C
10:55
32 C
10:55
Delete User
Delete User
32 C
10:55
TX RadioTX Radio
To confi rm the operation shift to YES using the arrow keys and confi rm using Enter.
20
The data and information shown in this manual may be changed by CAME cancelli automatici s.p.a. at any time without prior warning
EN
6.7 Radio TX - Menu
TX Radio
TX Radio
RADIO CHNL:1
RADIO CHNL:1
WAIT
WAIT
To select the radio channel
to be memorised shift using
the arrow and confi rm by
pressing Enter
TX Radio
TX Radio
1
RADIO CHNL
RADIO CHNL
Delete User
Delete User
TX Radio
TX Radio
32 C
10:55
TimerTimer
32 C
10:55
From the RADIO TX menu you can associate a CAME transmitter code to an output, so as to “repeat” it and
control the automated devices directly through the keyboard or transponder from WAVE.
Send the radio code by transmitter
within 10 seconds (as shown in
gure). Memorisation is confi rmed
when code is shown on display.
Use transmitters of the
following series: Top
433.92MHz or Tam
433.92MHz
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30

CAME WA01 Owner's manual

Type
Owner's manual

CAME WA01 is an automated home control system that provides users with a range of features to enhance convenience and security in their homes. With its ability to interface with the WI08 digital electronic card, users can control various aspects of their home automation system. The device operates on a 120-230V AC power supply and has a maximum power load of 5A 230V AC/24V DC for resistive loads and 1.5A 230V AC for inductive loads.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI