Identification:
Technical Bulletin no:
Date:
Issuer:
Factory:
C08
PDD2005-10
18 May 2005
F. Fingolo (Ovens Customer Support Dept.)
PDD Vallenoncello - Italy
Subject
New boiler for AOS102G
Model
AOS 102 gas range
Problem
Low lifetime of burner gasket
Reason
Working temperature of the rubber close to its limits
Action in Factory
New boiler and protection of the gasket; optimized the distribution of
temperature in the combustion chamber. Modification in production from
SN 515.
Action in Field
In case of burnt gasket, the old boiler should be changed with the new
one.
The new boiler (0C2567) is interchangeable with the old one changing
also the pipe connecting burner and fan (0C2568), the ignition rod
(0C1866, changed the length of the cable from 970mm to 1040mm,
same spare part code, cleaned warehouse) and using another gasket
(0C2569) and the suitable insulation (0C2589)
New boiler with different dimensions
BOILER AOS102G
code: 0C2567
ELECTROLUX PROFESSIONAL SPA