Savant SEM-1024-00 Reference guide

Type
Reference guide
SEM-1024 | 009-0358-05 | 170208
Copyright 2018 Savant Systems, LLC
45 Perseverance Way, Hyannis, MA 02601
Savant.com | 508.683.2500
1 of 2
Box Contents
Specifications
Environmental
Temperature 32° to 104° F (0° to 40° C)
Humidity 5% to 95% Relative Humidity (non-condensing)
Maximum BTU’s 27 BTU/hr
Cooling 1 cubic feet per minute (CFM) recommended
Dimensions and Weight
Height 12.51 in (31.78 cm)
Width 6.48 in (16.46 cm)
Depth 1.30 in (3.30 cm)
Weight Chassis 4 lb (1.81 kg) Shipping: 6.0 lb (2.72 kg)
Power
Input Power 12V AC
Max Power 8 Watts
Left Panel
Input ports for each Current Transformer installed in the system.
Sixteen ports are available on the left panel and an additional
eight ports are available on the right panel. Total Inputs = 24
Status
LED
O - SEM-1024 is either not powered or is booting the
embedded firmware.
Green Flashing - Provisioned to the local network (has
IP address) but not yet communicating with the Host.
Green - Provisioned to the local network and commu-
nicating with the Savant System Host.
Red - Savant System Host has determined a firmware
update is required. However, a problem occurred
during the update process that will initiate a reset.
Red Flashing - Embedded firmware is running but has
not received an IP Address.
Amber - Firmware is updating.
Amber Flashing - A link-local IP Address is established
and SEM-1024 is waiting to connect to the Host.
A
B
Reset Button
Press and hold for five seconds then release to
clear the network settings. After the reset, the
default DHCP mode is restored.
B
Data Speed
LED
10/100 Base-T auto-negotiating
Green - 100 Mb speed
O - 10 Mb speed
Data Activity
LED
10/100 Base-T auto-negotiating
Orange - Ethernet data activity
RS-232 Port Reserved for future use
12V AC Input
Connect the included power supply between
120V AC and the 12V AC port.
Gnd
Connect a #18 AWG wire between this Gnd
screw and a good grounding point. Making this
connection will achieve a greater level of safety
from electrical hazards and electromagnetic
interference (EMI). Savant recommends making
Gnd screw connection.
Voltage
Sensors
Voltage sensor input ports. Input port for the
SEM-VT01 voltage sensor.
Input
Channels
Additional Current Transformer input ports.
A
C
D
E
F
G
H
Right Panel
Optional Accessories
SEM-VT01 - SmartEnergy Voltage Sensors
CON-SDC2 - 2 pin screw-down connectors (25 pack)
Split Core Current Transformers (clamp-on style)
IMPORTANT! The SEM-250A1, SEM-400A1 and SEM-600A1 are
supported from da Vinci 5.2.3 and higher.
SEM-020A5 20A 8 ft leads (5 pack)
SEM-050A5 50A 8 ft leads (5 pack)
SEM-150A1 150A 8 ft leads (1 pack)
SEM-150A5 150A 8 ft leads (5 pack)
SEM-250A1 250A 8 ft leads (1 pack)
SEM-400A1 400A 8 ft leads (1 pack)
SEM-600A1 600A 8 ft leads (1 pack)
Minimum Supported Release
SEM-1024
da Vinci 4.3.3 and higher
Current Transformers
20, 50, and 150 Amps
Current Transformers
250, 400, and 600 Amps
da Vinci 5.2.3 and higher
Regulatory
Safety and Emissions
FCC Part 15
RoHs Compliant
Additional Information
Important Information
Current Transformer and Voltage Sensor Input Polarity
Additional Information is available on the Customer Community.
The polarity of the inputs for the Current Transformer and Voltage
Sensor inputs on the SEM-1024 are shown below.
SEM-1024 SmartEnergy Technical Specifications (009-0521-xx)
SEM-1024 SmartEnergy Deployment Guide (009-1024-xx)
SEM-1024 SmartEnergy Monitor Deployment Guide (009-0419-xx)
SEM-1024 SmartEnergy User Guide (009-0420-xx)
All wiring in the United States must be installed in accordance with
the latest adopted edition of the National Electrical Code (ANSI/
NFPA 70, NEC).
All wiring in Canada must be installed in accordance with the latest
adopted edition of the Canadian Electrical Code (CSA C222.2 CEC,
Part 1) and any provincial or local requirements.
The SEM-1024 supports services that are 600 amps or less. Verify
the main circuit breaker in your panel is not larger than 600 amps.
The maximum diameter of the wires feeding the main breaker
cannot exceed 1 inch. The SEM-1024 can not operate with larger
conductors.
Only 500 MCM conductors or smaller are supported.
TIP! MCM is unique to North America and represents the diameter
of a wire. Common MCM sizes are 500, 350, and 250.
Maximum length for leads on each current transformer should not
exceed 8 feet. Longer lengths will cause inaccurate readings.
If required, the leads on the current transformers can be shortened.
The SEM-1024I (International) supports 230V AC 50Hz services.
1 2 3 4 6 7 8 9 10 11 12 13 14 15 165
Input Channels
Status
A
B
Data
Reset
RS232
12VAC
Voltage Sensor
Input Channels
A
E F G
H
D
B
C
1
2
3
24
23 22 21 20 19 18
17
(1) SmartEnergy Monitor (SEM-1024-xx)
(1) Installation Kit Energy Monitor (075-0101-xx)
(1) Power Supply 12V AC 1A (025-0187-xx)
(24) Screw down plug-in 2 pin connectors (028-9394-xx)
(4) Screw M3 x 8mm Flat Phil Black (039-0017-xx)
(2) Side Mount Chassis Bracket (071-0628-xx)
(1) SEM Current Transformer ID Labels (1 sheet) (083-0042-xx)
(1) Quick Reference Guide (this document)
POS(+)
GND (-)
Current Transformer Input
POS (+) - White or red wire from Current
Transformer.
GND (-) - Black wire from Current Transformer
POS(+)
GND (-)
Voltage Sensor Input
POS (+) - Connect to the positive (+) output
on Voltage Sensor. See diagram in the Install
Voltage Sensors section.
GND (-) - Connect to the GND output of a
Voltage Sensor (SEM-1024). See diagram in
Install Voltage Sensors.
For Product Info
Savant® SmartEnergy Monitor (SEM-1024)
Quick Reference Guide
SEM-1024 | 009-0358-05 | 170208
Copyright 2018 Savant Systems, LLC
45 Perseverance Way, Hyannis, MA 02601
Savant.com | 508.683.2500
2 of 2
Three Phase System
One Phase System
The One Phase system diagram shown below should be used as a
reference when making connections.
The Three Phase system diagram shown below should be used as a
reference when making connections.
Install Voltage Sensor
Install Current Transformers
Voltage Sensor (SEM-VT01)
SAFETY CAUTIONS! Before beginning the installation process,
read through the following precautions.
The installation of a Current Transformer requires making con-
nections within an electrical panel. Savant recommends that a
licensed electrician perform the installation.
The install should obey all local electrical codes.
Only Current Transformers oered from Savant are supported.
These CT’s are internally shunted and safer than other commer-
cially available Current Transformers.
Mounting
Mounts to either a wall or similar using the included chassis mounted
side brackets and supplied
M3 x 8mm flat head screws. Mount chassis
in a place that is dry, well ventilated, and out of direct sunlight.
1. Remove side brackets and M3 x 8mm screws from shipping box.
2. Align the holes in the bracket with threaded holes on the two
short sides of the SEM-1024 energy monitor.
3. Screw bracket to chassis using the supplied M3 x 8mm screws. Do
not over-tighten.
4. Set the SEM-1024 onto the wall where it will be mounted. The
SEM-1024 can be positioned with ports facing vertically or hori-
zontally. Level the unit and mark on the wall the mounting holes in
the two brackets.
5. If there is a sub-wall to screw into, screw unit to wall using appro-
priate screws. If no sub-wall is available, wall anchors can be used.
Alternatively, the chassis can be set into a rack, cabinet, or similar.
Ensure the SEM-1024 is secured to a solid, flat, level surface.
Connecting Current Transformers
Follow instructions below when installing the current transformers into
an electrical breaker panel.
1. Remove power from electrical panel by switching the main break-
er to the O position.
2. Remove the electrical panel front cover and set aside. With a volt-
age tester, verify power was removed to the individual breakers.
3. Install the Current Transformers over each conductor being
monitored. Depending on the current transformer being used will
determine how it is installed. See below.
20 and 50 Amp Current Transformers
A. Pry the clip on the side of the Current Transformer away from
the housing and hinge open the Current Transformer.
B. Position the conductor being measured into the opening of the
Current Transformer. Close the Current Transformer ensuring
the clip on the side snaps into place. See images to the right.
IMPORTANT! To observe proper polarity, install the 20 and 50A
current transformers with arrows pointing in the direction
of current flow (towards the load).
C. Route the wire through a pre-installed cable clamp on the side
of the panel and run wire to the SEM-1024 chassis.
150 Amp Current Transformers
A. Squeeze the handle on side of Current Transformer until the
opposite end opens.
B. Position the open end of Current Transformer over the conduc-
tor and release the handle so the wire settles inside the opening
of Current Transformer.
IMPORTANT! To observe proper polarity, install the 150A or larger
current transformers with the label on the Current Trans-
former facing the source of the power.
C. Route the wire through a pre-installed cable clamp on the side
of the panel and run wire to the SEM-1024.
4. Following steps below, install the supplied 2-pin screw down con-
nector onto the wires of each Current Transformer.
A. With a small slotted screwdriver, turn the screws on the con-
nector counterclockwise (CCW) until the silver crimps open
enough to slide the stripped wire into the square slots.
B. Strip back insulation on each wire to 1/4 inch and insert the
stripped wire into proper connection. See the Current Trans-
former and Voltage Sensor Input Polarity section for polarity
information.
C. Turn screws clockwise (CW) until the crimps tighten around
each wire. Tug on wire a bit to verify they are secure. Continue
until all Current Transformers have a connector added to it.
5. Plug the connector into the appropriate Current Transformer input
on the SEM-1024.
6. Replace the breaker panel front cover once all Current Transform-
ers are installed.
7. Switch main breaker to the ON position.
The SEM-VT01 is a highly accurate voltage transformer that reduces
the input voltage by a factor of .001. For example, if the input voltage
is 120V AC, the output of the SEM-VT01 will be .120V AC. By reducing
the voltage, the SEM-1024 can monitor individual circuits with excep-
tional accuracy.
Important Information !
Voltage sensors must be used in 3 Phase systems and when mea-
suring bi-directional circuits.
One voltage sensor is required for each phase.
The SEM-VT01 is not required for Single Phase Circuits unless high-
er accuracy is required.
Install SEM-VT01 voltage sensor as close as possible to the electric
breaker panel.
Savant requires a licensed electrician be used to connect the SEM-
VT01 to the high voltage side. Follow instructions below to install. The
instructions assume the electrical outlet boxes are mounted and an
electric circuit is run into the box.
1. Switch the circuit breaker to the circuit that the SEM-VT01 is being
added to.
2. Using diagram below, make high voltage connections.
3. Screw the SEM-VT01 into the electrical box.
4. Using the supplied 2-pin screw down connectors and #18 AWG
wire, install the wires into the 2-pin connector. Refer to the con-
nector diagrams below when wiring.
5. For instructions on how to install wires into the 2-pin connectors,
refer to step 4 of the Install Current Transformers section.
Voltage Sensor Connection on
the SEM-VT01
Voltage Sensor Connection on
the SEM-1024
POS(+)GND (-)
POS(+)
GND (-)
From 3-Phase
Electrical Panel
Connect Voltage
Sensor to each Phase
6. Once all connections are made, switch the breaker back ON.
7. With the SEM-1024 and any optional accessories installed, the
system can now be programmed into RacePoint Blueprint and
deployed. Refer to the documents in the Additional Information
section above. Any of these documents are available on the Sa-
vant Customer Community.
  • Page 1 1
  • Page 2 2

Savant SEM-1024-00 Reference guide

Type
Reference guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI