FilterHousingReplaceableFilterHousingShowerhead
(Back)FilterCartridge(SLC)(Front)
INSTALLATION
1. Unscrewexisngshowerheadfromshowerarm.
2. Screwfilterhousing(Back)ontoshowerarm.
3. Screwshowerheadontofilterhousing(Front).
4. Donotusewithashut‐offvalve.
OPERATION
BEFOREENTERINGTHESHOWER
1. Acvatefilterbyrunninghotwaterthroughtheshower
system.
2. COOLTODESIREDTEMPERATUREBEFOREENTERING
SHOWER.
3. Replacethefiltercartridge(modelSLC)every10,000
gallonsor6months,whichevercomesfirst.
MAINTENANCE
1. TurnDial‐A‐Dateringtomonthofinstallaon.
2. ReplaceSLCfiltercartridgeevery10,000gallonsor6
months,whichevercomesfirst.
FILTERCARTRIDGEREPLACEMENT(SLC)Replacefiltercar‐
tridgeevery10,000gallonsor6months,whichevercomes
first.
1. Toopen,unscrewshowerfilterhousing.
2. Removeusedfiltercartridge.
3. CleanandlubricateO‐ringswithpetroleumjelly.
4. Toclose,screwhousingstogether.
RECYCLEFILTERCARTRIDGE
1. Carefullypokeaholeinthescreenofthe
filtercartridgeandemptycontentsintogarden
soil.
2. Placethefiltercartridgeinwithrecyclables.
SpriteIndustries,Inc.
TheShowerFilterCompany
1791RailroadSt,Corona,CA92880‐2511
Phone:800‐327‐9137Fax:951‐735‐1016
PERFORMANCEDATA:(ModelSL2)
RatedServiceFlow–2.5gallonsperminute/9.5litersper
minute
RatedServiceLifeforFreeChlorineremoval–10,000gallons/
37,854litersor6months(whichevercomesfirst)
MaximumWorkingPressure–125poundspersquareinch/
860kilopascals.
MaximumOperangTemperature‐120°Fahrenheit/49°Cel‐
sius.
• While tesƟng was performed under laboratory condiƟons.
Actual performance may vary.
• This system is not intended to be used as a drinking water
treatment unit.
• Both the system and installaƟon must comply with appli-
cable state and local regulaƟons.
ThisSpriteShowerFiltraonSystemhasbeentestedaccording
toNSF/ANSI177forreduconoffreechlorine.Theconcentra‐
on of free available chlorine in water entering the system
wasreducedtoaconcentraonlessthan
orequaltotheper‐
missiblelimitforwaterleavingthesystem,asspecifiedinNSF/
ANSI177.Thissystemhasnotbeenevaluatedforfreechlorine
reduconinthepresenceofchloramines.Freechlorinereduc‐
onperformancemaybeimpactedbythepresenceofchlora‐
minesin
thewatersupply.
NotesonNSFTestProtocol:
Minimum chlorine reducon per NSF/ANSI 177
shall be listed as≥50% free available chlorine
(FAC) when used with an influent challenge water
of2mg/L FAC. Averageconcentraonsshall bethe arithmec
meanofallreportedinfluentchallengeorproductwatercon‐
centraons(thedetecon
limitvalueshallbeusedforanynon
‐detectable concentraon). The specified average percent re‐
duconshallnot begreaterthanthe reducon calculatedus‐
ing the arithmec means of the influent challenge and the
productwaterconcentraonsrespecvely.
O‐ring O‐ring Dial‐A‐Date
USE&CAREINSTRUCTIONS
SLIM‐LINESHOWERFILTER
ModelSL2