Wacker Neuson PSA22203L User manual

Category
Water pumps
Type
User manual

This manual is also suitable for

Operator’s Manual
Pump
PS2-1503L / 2203L
PSA2-1503L / 2203L
Type PS2-1503L / 2203L, PSA2-1503L / 2203L
Document 5000184994
Date
1215
Version 04
Language
EN
5000184994
Copyright notice
© Copyright 2015 by Wacker Neuson Production Americas LLC
All rights, including copying and distribution rights, are reserved.
This publication may be photocopied by the original purchaser of the
machine. Any other type of reproduction is prohibited without express
written permission from Wacker Neuson Production Americas LLC.
Any type of reproduction or distribution not authorized by Wacker
Neuson Production Americas LLC represents an infringement of valid
copyrights. Violators will be prosecuted.
Trademarks
All trademarks referenced in this manual are the property of their
respective owners.
Manufacturer
Wacker Neuson Production Americas LLC
N92W15000 Anthony Avenue
Menomonee Falls, WI 53051 U.S.A.
Tel: (262) 255-0500 · Fax: (262) 255-0550 · Tel: (800) 770-0957
www.wackerneuson.com
Original instructions
This Operator’s Manual presents the original instructions. The original
language of this Operator’s Manual is American English.
Foreword
wc_tx001295gb.fm 3
Foreword
SAVE THESE INSTRUCTIONS—This manual contains important instructions for
the machine models below. These instructions have been written expressly by
Wacker Neuson Production Americas LLC and must be followed during installation,
operation, and maintenance of the machines.
Machines
covered by
this manual
Machine
documentation
Keep a copy of the Operator’s Manual with the machine at all times.
Use the separate Parts Book supplied with the machine to order replacement
parts.
Refer to the separate Repair Manual for detailed instructions on servicing and
repairing the machine.
If you are missing any of these documents, please contact Wacker Neuson
Corporation to order a replacement or visit www.wackerneuson.com.
When ordering parts or requesting service information, be prepared to provide
the machine model number, item number, revision number, and serial number.
Expectations
for
information in
this manual
This manual provides information and procedures to safely operate and main-
tain the above Wacker Neuson model(s). For your own safety and to reduce the
risk of injury, carefully read, understand, and observe all instructions described
in this manual.
Wacker Neuson Corporation expressly reserves the right to make technical
modifications, even without notice, which improve the performance or safety
standards of its machines.
The information contained in this manual is based on machines manufactured
up until the time of publication. Wacker Neuson Corporation reserves the right
to change any portion of this information without notice.
Machine Item Number Machine Item Number
PS2 1503L 0620461
0620462
PSA2 1503L 0620463
PS2 2203L 0620464
0620465
PSA2 2203L 0620466
Foreword
4 wc_tx001295gb.fm
Manufacturers
approval
This manual contains references to approved parts, attachments, and
modifications. The following definitions apply:
Approved parts or attachments are those either manufactured or provided by
Wacker Neuson.
Approved modifications are those performed by an authorized Wacker Neu-
son service center according to written instructions published by Wacker Neu-
son.
Unapproved parts, attachments, and modifications are those that do not
meet the approved criteria.
Unapproved parts, attachments, or modifications may have the following
consequences:
Serious injury hazards to the operator and persons in the work area
Permanent damage to the machine which will not be covered under warranty
Contact your Wacker Neuson dealer immediately if you have questions about
approved or unapproved parts, attachments, or modifications.
2015-CE-PS2-xxxx_en_FM10_new.fm
EC Declaration of Conformity
Manufacturer
Wacker Neuson Production Americas LLC, N92W15000 Anthony Avenue,
Menomonee Falls, Wisconsin 53051 USA
Product
Product
Product category
Product function
Item number
PST2 400, PS2 500, PSA2 500, PS2 800, PSA2 800, PS2 1503, PS2 1500,
PS2 1503L, PSA2 1503L, PS2 2203, PS2 2203L, PSA2 2203L, PS2 3703
Water Pump Units
To pump fluid
5000009173, 5000009175, 5000008786, 5000008788, 5000008789,
5000008793, 5000008794, 5000008796, 5000009176, 5000009178,
5000008787, 5000008790, 5000008792, 5000009179, 5000009181,
5000620438, 5000620439, 5000620452, 5000620449, 5000620450,
5000620458, 5000009186, 5000008802, 5000008803, 5000009190,
5000009190, 5000008814, 5000008815, 5000008826, 5000008827,
5000620461, 5000620462, 5000620463, 5000620464, 5000620465,
5000620466
Directives and Standards
We hereby declare that this product meets and complies with the relevant regulations and
requirements of the following directives and standards:
2006/42/EC, 2006/95/EC, 2004/108/EC, EN 809, EN ISO 12100, EN 60204-1,
EN 60335-1, EN 60335-2-41, EN 62233, EN 61000-6
Authorized Person for Technical Documents
Leo Goeschka, Wacker Neuson Produktion GmbH & Co. KG, Preußenstraße 41,
80809 München
Menomonee Falls, WI, USA, 27.04.15
Original Declaration of Conformity
Dan Domanski
Technical Director
For Wacker Neuson
Travis Pound
Manager, Product Engineering
For Wacker Neuson
Keith Herr
Managing Director
For Wacker Neuson
wc_bo5000184994_03TOC.fm 7
Table of ContentsPS2/PSA2 1503L/2203L
Foreword 3
EC Declaration of Conformity 5
1 Safety Information 9
1.1 Signal Words Used in this Manual ....................................................... 9
1.2 Machine Description and Intended Use ............................................. 10
1.3 Operating and Electrical Safety .......................................................... 11
1.4 Labels ................................................................................................. 12
2 Operation 13
2.1 Names of Parts ................................................................................... 13
2.2 Prior to Operation ............................................................................... 14
2.3 Preparing for Installation .................................................................... 14
2.4 Preparing for installation ..................................................................... 15
2.5 Installation .......................................................................................... 16
2.6 Checks to Make Before Installation .................................................... 17
2.7 Electrical Wiring .................................................................................. 18
2.8 Cable Assembly ................................................................................. 19
2.9 Electrical Circuit Diagram ................................................................... 20
2.10 Operation ............................................................................................ 21
2.11 Operating Water Level ....................................................................... 22
2.12 Starting Water Level (PSA2 models) .................................................. 23
2.13 Circle Thermal Protector .................................................................... 26
2.14 Emergency Shutdown Procedure ....................................................... 26
3 Maintenance 28
3.1 Periodic Maintenance Table ............................................................... 28
3.2 Maintenance and Inspection .............................................................. 29
3.3 Storage ............................................................................................... 29
3.4 Lubrication Inspection and Changing Procedures .............................. 30
3.5 Replacement Parts ............................................................................. 31
3.6 Disassembly/Reassembly .................................................................. 31
3.7 Disassembly ....................................................................................... 32
3.8 Reassembly ........................................................................................ 33
3.9 Troubleshooting .................................................................................. 34
8 wc_bo5000184994_03TOC.fm
Table of Contents PS2/PSA2 1503L/2203L
4 Technical Data 35
4.1 Standard Specifications .......................................................................35
4.2 Operating Specifications .....................................................................36
4.3 Dimensions .........................................................................................37
5 AEM Safety Manual 38
wc_si000366gb.fm
9
PS2/PSA2 1503L/2203L Safety Information
1 Safety Information
1.1 Signal Words Used in this Manual
This manual contains DANGER, WARNING, CAUTION, NOTICE, and NOTE
signal words which must be followed to reduce the possibility of personal injury,
damage to the equipment, or improper service.
NOTICE: Used without the safety alert symbol, NOTICE indicates a situation
which, if not avoided, could result in property damage.
Note: A Note contains additional information important to a procedure.
This is the safety alert symbol. It is used to alert you to potential personal hazards.
f Obey all safety messages that follow this symbol.
DANGER
DANGER indicates a hazardous situation which, if not avoided, will result in death
or serious injury.
f To avoid death or serious injury from this type of hazard, obey all safety
messages that follow this signal word.
WARNING
WARNING indicates a hazardous situation which, if not avoided, could result in
death or serious injury.
f To avoid possible death or serious injury from this type of hazard, obey all safety
messages that follow this signal word.
CAUTION
CAUTION indicates a hazardous situation which, if not avoided, could result in
minor or moderate injury.
f To avoid possible minor or moderate injury from this type of hazard, obey all
safety messages that follow this signal word.
wc_si000366gb.fm
10
Safety Information PS2/PSA2 1503L/2203L
1.2 Machine Description and Intended Use
This machine is a submersible water pump. The Wacker Neuson Submersible Pump
consists of an electric motor, an impeller, a strainer, and a metal casing with ports for
water suction and discharge. Power is supplied to the pump through a corded plug or a
hard-wired connection, depending on the installation. The operator connects hoses to
the pump and routes them so that water is pumped from the work area and discharged
into an appropriate location.
This machine is intended to be used for general de-watering applications. This machine
is intended for the pumping of clear water, or water containing solids up to the size
stated within the product’s specifications, and up to the flow, head, and suction lift limits
also stated within the product’s specifications.
This machine has been designed and built strictly for the intended use described
above. Using the machine for any other purpose could permanently damage the
machine or seriously injure the operator or other persons in the area. Machine damage
caused by misuse is not covered under warranty.
The following are some examples of misuse:
Pumping flammable, explosive, or corrosive fluids
Pumping hot or volatile fluids that result in pump cavitation
Operating the pump outside of product specifications due to incorrect diameter
hoses, incorrect length hoses, other inlet or outlet restrictions, or excessive
suction lift or head
Using the machine as a ladder, support, or work surface
Using the machine to carry or transport passengers or equipment
Operating the machine outside of factory specifications
Operating the machine in a manner inconsistent with all warnings found on the
machine and in the Operator’s Manual.
This machine has been designed and built in accordance with the latest global safety
standards. It has been carefully engineered to eliminate hazards as far as practicable
and to increase operator safety through protective guards and labeling. However, some
risks may remain even after protective measures have been taken. They are called
residual risks. On this machine, they may include exposure to:
Electric shock from improper electrical connections or high voltage
Personal injury from improper lifting techniques
Projectile hazard from discharge
To protect yourself and others, make sure you thoroughly read and understand the
safety information presented in this manual before operating the machine.
wc_si000366gb.fm
11
PS2/PSA2 1503L/2203L Safety Information
Operator
qualifications
Only trained personnel are permitted to start, operate, and shut down the machine.
They also must meet the following qualifications:
have received instruction on how to properly use the machine
are familiar with required safety devices
The machine must not be accessed or operated by:
children
people impaired by alcohol or drugs
Personal
Protective
Equipment
(PPE)
Wear the following Personal Protective Equipment (PPE) while operating this
machine:
Close-fitting work clothes that do not hinder movement
Safety glasses with side shields
Hearing protection
Safety-toed footwear
1.3 Operating and Electrical Safety
To reduce risk of electric shock, connect only to a properly grounded, grounding-
type receptacle.
Risk of electric shock—this pump has not been investigated for use in swimming
pool areas.
An acceptable motor-control switch shall be provided at the time of installation
according to local codes and regulations.
To reduce risk of electric shock, follow instructions in this manual for proper
installation.
CAUTION: This pump may automatically restart. Prior to working on the pump or
control panel, all supply circuits must be disconnected.
CAUTION: Risk of shock—do not remove cord and strain relief.
WARNING
wc_si000366gb.fm
12
Safety Information PS2/PSA2 1503L/2203L
1.4 Labels
Wacker Neuson machines use international pictorial labels where needed. These
labels are described below.
A nameplate listing the model number, item number, revi-
sion number, and serial number is attached to each unit.
Please record the information found on this nameplate so it
will be available should the nameplate become lost or dam-
aged. When ordering parts or requesting service informa-
tion, you will always be asked to specify the model number,
item number, revision number, and serial number of the
unit.
CAUTION
Do not attempt to operate this product before reading the
Operator’s Manual and understanding its contents. Mishan-
dling of this product may result in explosion, fire, or electri-
cal shock.
Do not pull on the power cord or use the power cord to lift
the pump.
Always use a dedicated ground leakage circuit breaker.
Be sure to install the ground wire securely.
Be sure to disconnect the power supply before handling
or inspecting the pump.
Never insert your hand into the pump inlet holes while the
pump is connected to the power supply.
JAPAN
JAPAN
wc_tx001296gb.fm
13
PS2/PSA2 1503L/2203L Operation
2 Operation
2.1 Names of Parts
1
14
13
5
12
11
10
7
6
9
15
wc_
g
r01049
9
Ref Description Ref Description
1 Lifting handle 9 Lubricant
2 Coupling 10 Seal-dust (V-ring)
3 Protective packing 11 Shaft sleeve
4 Oil plug 12 Rear liner
5 Pump casing 13 Oil casing
6 Strainer stand 14 Impeller
7 Cable assembly 15 Electrode (if equipped)
8 Seal-mechanical
wc_tx001296gb.fm
14
Operation PS2/PSA2 1503L/2203L
2.2 Prior to Operation
When the pump is delivered, first perform the following checks:
Inspection
While unpacking, inspect the product for damage during shipment, and make sure
all bolts and nuts are tightened properly.
Specification check
Check the model number to make sure it is the product that was ordered. Be
certain it is the correct voltage and frequency.
Note: If there is any problem with the product as shipped, contact your nearest
dealer or Wacker Neuson representative at once.
Product specifications
Do not operate this product under any conditions other than those for which it is
specified. Failure to observe this precaution can lead to electrical shock, current
leakage, fire, water leakage, or other problems.
2.3 Preparing for Installation
Preparing for
Installation
Observe the following points when preparing to install the pump.
Be aware that leakage of pump lubricants may cause pollution of water.
An appropriate plug or electrical connection must be provided according to local
codes and standards. Refer to the wiring diagram.
Use with a power supply voltage within ±5% of the rated voltage.
Operating
Safety
Do not operate the pump if the maximum water pressure in the area exceeds
0.3 MPa–discharge pressure.
Do not use this pump in liquids other than water, such as oil, salt water, or
organic solvents. Contact your Wacker Neuson dealer with questions about
specific fluids.
Do not use in water temperatures outside the range of 0–40°C (32–104°F)
which can lead to failure, electrical leakage, or shock.
Do not use in the vicinity of explosive or flammable materials.
Do not operate the pump if any parts are loose or missing.
CAUTION
wc_tx001296gb.fm
15
PS2/PSA2 1503L/2203L Operation
2.4 Preparing for installation
Before installing the pump at a work site, you will need to have the following tools
and instruments ready:
Insulation resistance tester (megohmmeter)
AC voltmeter
AC ammeter (clamp-on type)
Bolt and nut tighteners
Power supply connection tools (screwdriver or box wrench)
Note: Please also read the instructions that come with each of the test instruments.
Measure
resistance
Use a megohmmeter to measure the insulation resistance between each core lead
and the ground lead to verify the insulation resistance of the motor.
Reference insulation resistance: 20MΩ or greater
Note: The reference insulation resistance (20M
Ω
or greater) is the value when the
pump is new or has been repaired. For the reference value after installation, see
“Periodic Maintenance Table.”
wc_gr007262
Description Description
U Power Lead (Brown) W Power Lead (Black)
V Power Lead (Blue or Gray) G Ground (Green/Yellow)
wc_tx001296gb.fm
16
Operation PS2/PSA2 1503L/2203L
2.5 Installation
If the pump is used for outdoor fountains, garden ponds and similar places, or to
drain a swimming pool, the pump must be supplied by an isolating transformer or
connected to a Residual Current Device (RCD) with a residual operating current
not exceeding 30 mA.
The pump must not be used when people are in the water.
Leakage of pump lubricants may cause pollution of water.
Proper plug must be provided according to local codes and standards. Refer to
wiring diagram.
Do not use this pump in liquids other than water, such as oil, salt water, or organic
solvents.
Use with a power supply voltage within ±5% of the rated voltage.
Do not use in water temperatures outside the range of 0–40°C
(32–104°F) which can lead to failure, electrical leakage or shock.
Do not use in the vicinity of explosive or flammable materials.
Use only in fully assembled state.
Note: Consult your local dealer or Wacker Neuson representative before using
with any liquids other than those indicated in this manual.
WARNING
wc_tx001296gb.fm
17
PS2/PSA2 1503L/2203L Operation
2.6 Checks to Make Before Installation
When a grounded plug is used:
Use the megohmmeter to measure the insulation resistance between the cable
assembly prongs and ground.
When connection leads are used:
With the megohmmeter, measure the insulation resistance between each core lead
and the ground lead.
Reference insulation resistance: 20MΩ or greater
Note: The reference insulation resistance (20M
Ω
or greater) is the value when the
pump is new or has been repaired. For the reference value after installation, see
“Periodic Maintenance Table.”
Improper ways to measure insulation resistance
All models 1 Between the plug prongs.
PSA2 1503L
PSA2 2203L
2 Between the electrode and the pump body.
3 Between the electrode and each lead wire.
1
wc_gr007330
2
3
wc_tx001296gb.fm
18
Operation PS2/PSA2 1503L/2203L
2.7 Electrical Wiring
General
information
Electrical wiring should be performed by a qualified electrician in accord with all
applicable regulations. Failure to observe this precaution not only risks breaking
the law, but is extremely hazardous.
Make sure the pump is equipped with the specified overload protectors, fuses,
and/or breakers. These items are designed to guard against electrical shock
from a current leak or pump malfunction.
Operate within the capacity of the power supply and wiring.
Grounding the
pump
Do not use the pump without first grounding it properly.
Do not attach the grounding wire to a gas pipe, water pipe, lightning rod, or
telephone grounding wire.
Connecting
the power
supply
Before connecting leads to the terminal strip, make certain the power supply is
disconnected (i.e. through circuit breakers) to avoid electrical shock, shorting, or
unexpected starting of the pump.
Do not use the pump with the cable assembly connected loosely.
Draw power from a dedicated power outlet rated at 15 A or above. Sharing the
outlet with other equipment may cause overheating at the branch outlet and
could result in fire.
Use a dedicated power supply with a ground leakage circuit breaker.
Tighten the ends of the cable assembly securely against the terminal board.
WARNING
An improperly wired pump can result in current leakage, personal injury, electrical
shock, fire, or permanent equipment damage.
f Observe the safety considerations below when performing electrical wiring.
wc_gr007264
Description Description
U Power Lead (Brown) W Power Lead (Black)
V
Power Lead (Blue or Gray)
G Ground (Green/Yellow)
wc_tx001296gb.fm
19
PS2/PSA2 1503L/2203L Operation
2.8 Cable Assembly
Extending the
cable
If it is necessary to extend the cable assembly, use a core size equal to or larger
than the original. This is necessary to avoid a performance drop and cable
overheating which may result in current leakage, electrical shock, or fire.
Avoiding
cable damage
Do not suspend the pump by the cable.
Make sure the cable does not become excessively bent or twisted.
Do not allow the cable to rub against a structure in a way that might damage it.
Repair or replace a cut or damaged cable immediately.
Submerging
the cable
Do not submerge a cable with cut insulation or other damage.
If it is necessary to submerge the connection wires of the cable assembly in
water, first seal the wires completely in a molded protective sleeve.
Do not allow the cable assembly wires or power supply plug to become wet.
WARNING
Current leakage, electrical shock, or fire hazards.
f Observe the safety considerations below when handling the cable assembly.
wc_tx001296gb.fm
20
Operation PS2/PSA2 1503L/2203L
2.9 Electrical Circuit Diagram
If connected to a circuit protected by a fuse, use a time-delay fuse with this pump.
wc_gr007099
1
2
3
Br
L-Gr
B
G/Y
Ref. Description Ref. Description
1 Circle thermal protector 3 Ground
2Coil
Wire Colors
B Black V Violet Or Orange
G Green W White Pr Purple
L Blue Y Yellow Sh Shield
P Pink Br Brown LL Light Blue
R Red Cl Clear G/Y Green/Yellow
T Tan Gr Gray L-Gr Blue or Gray
CAUTION
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52

Wacker Neuson PSA22203L User manual

Category
Water pumps
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI