Symmons Industries S-3501-CYL-B-BBZ-1.5-TRM, S-3501-CYL-B-1.5, S-3501-CYL-B-1.5-TRM, S-3501-CYL-B-STN, S-3501-CYL-B-STN-TRM Installation guide

  • Hello! I am an AI chatbot trained to assist you with the Symmons Industries S-3501-CYL-B-BBZ-1.5-TRM Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Warranty
Limited Lifetime - to the original end purchaser in
consumer installations
5 years - for commercial installations
Location:
Dia
Model Numbers
S-3501-CYL-B
Shower System with Symmons Temptrol
®
mixing valve
p/n 4000-BODY
S-3501-CYL-B-TRM
Trim only, valve must be ordered separately
S-4001-BODY
Symmons Temptrol
®
mixing valve without trim
S-4001-X-BODY
Symmons Temptrol
®
valve without trim. Valve includes
integral service stops to allow water shut-o for service
Standards / Certifications
ASME A112.18.1-2005 / CSA B125.1-05
Americans with Disabilities Act (ADA) compliant
Finish Options / Modifications
Append appropriate -sux to model number
-STN
Satin nickel
-
Polished chrome (standard nish)
Options / Modifications
Append appropriate -sux to model number
-IPS
IPS connections: 1/2 inch female IPS
connections on Temptrol
®
mixing valve
(not available with service stops, sux -X)
-X
Service Stops: Temptrol
®
mixing valve
includes integral service stops to allow water
shut-o for service, p/n S-4001-X-BODY
(available when ordering model S-3501-CYL)
-CHKS
Check Stops: Temptrol
®
mixing valve
includes integral check stops
(Requires integral service stop, sux -X
. Used
in installations where a positive shut-o device is
used downstream of mixing valve.)
-REV
Reverse core: Temptrol® mixing valve
with reverse core. (Requires integral service
stop, sux -X . Used in back-to-back system
installations. HOT on the right, COLD on the le)
Delete
Suffix B
Chrome plastic escutcheon
chrome plastic escutcheon is supplied instead
of standard brass escutcheon
-2.0
Flow rate restrictor, 2.0 gpm (7.6 L/min)
-1.5
Flow rate restrictor, 1.5 gpm (5.7 L/min)
-L/HD
Showerhead not included,
Includes mounting bracket and ange
352SH-3
Showerhead is three-mode in place of
standard single mode
-LR -LP
-LR
Lever handle
-LP
Loop style lever handle
Handle Options / Modifications
Append appropriate -sux to model number
Specification Submittal
Shower System
S-3501-CYL-B
Standard Feature Highlights
Shower System with Symmons Temptrol
®
pressure-balancing
mixing valve with adjustable stop screw to limit handle turn
Screwless brass escutcheon (-B)
Cylinder (CYL) style lever handle
Showerhead, single mode #352SH
Mounting bracket and ange for showerhead
Standard ow rate is 2.5 gpm (9.5 L/min)
Optional lower ow rate restrictor available
Polished chrome nish (standard)
Print
Email
Reset Form
2-7/8
±
½"
(72 mm
±
13 mm)
7-3/4" dia
(197 mm)
nished wall
Floor
hot / cold
supply
showerhead
supply
5/8" (16 mm)
2-1/2" dia
(64 mm)
tub spout
supply plug
1/2"-14 NPT
mounting plate
p/n T-177
*
Note (1)
Temptrol
control valve
*
Notes:
(1) Walls for using T-177 mounting plate (MP)
Wall is 1/16" (2 mm) min • 1/2" (13 mm) max
Fiber or acrylic walls (MP required)
Plaster or other type walls 1/2" or less (MP optional)
Protective shield usage (optional)
(2) Dry wall, plaster or other type walls 1/2" or greater
Protective shield is required; snaps on end of valve spindle...
(3) Dimensions subject to change without notice
Wall cutout hole size
3-1/2" (89 mm) min
4" (101 mm) min
approx
27"
(686 mm)
approx
48"
(1219 mm)
Finished wall to rear of valve
3-1/2"
±
1/2" (89 mm
±
13 mm
Finished wall to pipe centerline
2-3/8"
±
1/2" (60 mm
±
13 mm)
*See note (2)
Protective
Shield
p/n T-176
6-5/8" ±1/2"
(167 mm ±13 mm)
5-1/4"
(133 mm)
3"
(76 mm)
Dimensions Dia Shower System, S-3501-CYL-B
Symmons Industries, Inc. 31 Brooks Drive Braintree, MA 02184 (800)796-6667, (781)848-2250 Fax: (800)961-9621, (781)664-1300
©2012 Symmons Industries, Inc. Printed in U.S.A. www.symmons.com [email protected] 062112
/