The New York Brick Oven Company 140-GW–WD-G is a commercial oven that has been tested to UL Subject 2162 and ANSI Z83.11 standards. It is a solid fuel/gas oven that is designed for use in food service establishments. The oven has a number of features that make it a good choice for commercial use including:

  • It is made of durable materials that are designed to withstand the high temperatures and heavy use that is common in commercial kitchens.
  • It has a large cooking capacity, which makes it ideal for cooking large batches of food.
  • It has a variety of cooking modes, which gives you the flexibility to cook a wide range of foods.

The New York Brick Oven Company 140-GW–WD-G is a commercial oven that has been tested to UL Subject 2162 and ANSI Z83.11 standards. It is a solid fuel/gas oven that is designed for use in food service establishments. The oven has a number of features that make it a good choice for commercial use including:

  • It is made of durable materials that are designed to withstand the high temperatures and heavy use that is common in commercial kitchens.
  • It has a large cooking capacity, which makes it ideal for cooking large batches of food.
  • It has a variety of cooking modes, which gives you the flexibility to cook a wide range of foods.
New York Brick Oven Company
N e w Y o r k B r i c k O v e n C o m p a n y t h e W o r l d ’ s B e s t O v e n s
1 7 1 8 H y l a n B l v d S t a t e n I s l a n d N e w Y o r k 1 0 3 0 5 ( 7 1 8 ) 9 8 7 - 2 4 2 2
READ ALL INSTUCTIONS BEFORE INSTALLING OR USING THIS
PRODUCT
Commercial Oven Installation and Operation Manual
Installation and Operating Instructions for New York Brick Oven Models: 140-GWWD-G
125-GW-WD-G 105-GW-WD-G 85-GW-G-W
Model(s) 140 W WG G 125 W WG G 105 W WG
G 85 W WG G
Listed Solid Fuel/Gas Oven
Tested to UL Subject 2162, ANSI Z83.11(year)
Food Service Equipment
READ THE ENTIRE MANUAL BEFORE YOU INSTALL THE OVEN
WARNING
A MAJOR CAUSE OF OVEN-RELATED FIRE IS FAILURE TO
MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO
COMBUSTIBLE MATERIALS. IT IS OF UTMOST
IMPORTANCE THAT THIS OVEN BE INSTALLED ONLY IN
ACCORDANCE WITH THESE INSTRUCTIONS.
IF THIS OVEN IS NOT PROPERLY INSTALLED A FIRE MAY
RESULT. TO REDUCE THE RISK OF FIRE, FOLLOW ALL
INSTALLATION INSTRUCTIONS WITH IN THIS MANUAL .
Contact the Factory, or a Local Service Company to Perform Maintenance
and Repairs.
Electrical diagrams are located on the motor control box directly at bottom of
oven.
For an additional copy of this manual or response to service or maintenance
questions please contact New York Brick Oven Company 1718 Hylan Blvd.
Staten Island New York 10305 (718) 668- 2310
PLEASE READ THE ENTIRE MANUAL BEFORE YOU INSTALL THE OVEN
DO NOT THROW THIS MANUAL AWAY
New York Brick Oven Company
N
N e w Y o r k B r i c k O v e n C o m p a n y t h e W o r l d ’ s B e s t O v e n s
1 7 1 8 H y l a n B l v d S t a t e n I s l a n d N e w Y o r k 1 0 3 0 5 ( 7 1 8 ) 9 8 7 - 2 4 2 2
WARNING
FOR YOUR SAFETY. DO NOT STORE OR USE ANY FLAMABLE LIQUIDS IN
THE VICINITY OF OVEN. KEEP THE AREA UNDERNEATH THE OVEN
CLEAN AND FREE FROM ANY COMBUSTIBLE MATERIALS
FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY
DAMAGE, BODILY HARM OR EVEN DEATH CONTACT YOUR LOCAL
BUILDING OR FIRE OFFICAILS ABOUT RESTRICTIONS AND
INSTALLATIONS INSPECTION IN YOUR AREA. IMPROPER
INSTALATION, ALTERATION, SERVICE OR MAINTENACE CAN
RESULT IN PROPERTY DAMAGE, INJURY, OR DEATH. IT IS
ESSENTAIL TO USE BUILDING MATERAILS SPECIFIDE FOR
INSTALLATION Read the installation, operation and maintenance
instructions thoroughly before installing or servicing this equipment.
IMPORTANT: Consult your local gas supplier for a statement outlining a
procedure to be followed in the event you smell gas. Post the
statement in a prominent location.
Always Disconnect the Power Supply to the Appliance Before Servicing or
Cleaning. Contact your local building or fire officials for clarification
on any restrictions on installation of this oven in your area, or need
for inspection of the oven installation.
WARNING THE OVEN IS HOT WHILE IN OPERATION. KEEP CHILDREN, CLOTHING AND
FURNITURE AWAY. CONTACT MAY CAUSE SKIN BURNS OR COMBUSTION. DO NOT
BURN FLAMMABLE FLUIDS. DO NOT BURN WOOD ON ROTATING DECK.
USE WOOD CHAMBER FOR WOOD BURNING OVENS ONLY DESIGNATED WITH “W” OR
“WG” OVENS ONLY. NEVER USE WOOD IN MODLES DESINATED (G) ONLY
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
IMPORTANT USE FIRE WOOD ONLYDO NOT USE CHARCOAL, CHIPPED WOOD
PRODUCTS, SAPPY WOOD PRODUCTS LAMINATED WOOD or any
material other than dry medium or hard firewood.DO NOT USE Gasoline,
lantern oil, kerosene or any similar liquids to start or maintain a fire
.BEWARE of very high temperatures in the oven and use long oven gloves
and mitts to handle pots and tools. DO NOT put unprotected hands or
arms inside oven.
Dispose of ashes in a fire rated metal bin with a tightly fitting lid. The
container should be stored on a non-combustible surface, away from all
combustible materials. Ensure ashes are completely cold and extinguished
before disposing.
WARNING DO NOT PACK REQUIRED AIR SPACES WITH INSULATION OR
OTHER MATERAILS. This appliance is for indoor use only.
SAVE THESE INSTRUCTIONS
New York Brick Oven Company
N e w Y o r k B r i c k O v e n C o m p a n y t h e W o r l d ’ s B e s t O v e n s
1 7 1 8 H y l a n B l v d S t a t e n I s l a n d N e w Y o r k 1 0 3 0 5 ( 7 1 8 ) 9 8 7 - 2 4 2 2
Table of Contents
Delivery and installation Page 1
Clearances to combustibles and non-combustibles Page 2-4
Ventilation Page 5-7
Gas Specifications Page 8-10
Electrical Specifications Page 11
Operating and Maintenance Instructions Page 12-14
Understanding the Gas Control system’s Page 15-18
Floor speed controls Page 19
Sanitation Practices Page 20 -21
Warranty Page 22-23
Oven Diagrams size and weight Page 25-32
Installation Supplement
New York Brick Oven Company
N
N e w Y o r k B r i c k O v e n C o m p a n y t h e W o r l d ’ s B e s t O v e n s
1 7 1 8 H y l a n B l v d S t a t e n I s l a n d N e w Y o r k 1 0 3 0 5 ( 7 1 8 ) 9 8 7 - 2 4 2 2
Delivery and Installation of Ovens
Factory Assembled On location
The Oven Shall only be assembled by a factory authorized technician of
The New York Brick Oven Company Only. The complete oven shall be
installed on a noncombustible surface that is capable of supporting the
distributed load of the specific oven. We recommend ¼ x 8x8 steel foot
plates to be installed under legs to help distribute the weight. Check with
local engineers for all floor ratings and approvals before installation. The
oven must also be installed on a noncombustible surface. Read clearance
section for details and warnings.
PAGE 1
New York Brick Oven Company
N e w Y o r k B r i c k O v e n C o m p a n y t h e W o r l d ’ s B e s t O v e n s
1 7 1 8 H y l a n B l v d S t a t e n I s l a n d N e w Y o r k 1 0 3 0 5 ( 7 1 8 ) 9 8 7 - 2 4 2 2
Oven Clearances to Combustible and Noncombustible
Materials
WARNING A MAJOR CAUSE OF OVEN-RELATED FIRED IS FAILURE TO MAINTAIN
REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS OF
UTMOST IMPORTANCE THAT THIS OVEN BE INSTALLED ONLY IN ACCORDANCE WITH
THESE INSTRUCTIONS.
DO NOT PUT WOOD AND DRYWALL IN CONTACT WITH THE OVEN. IF YOU NEED TO
ENCLOSE YOUR OVEN FRONT, USE NON-COMBUSTIBLE METAL STUDS AND
CONCRETE BACKER BOARD. For Use Only On Noncombustible
Floors.
It is essential to maintain clearance space between the oven components
and any combustible material, such as walls and ceilings. Failure to
maintain these clearances can result in fire.
Combustible Wall Clearance
Figure 1 Noncombustible on all sides of oven 2”
Noncombustible from top 24’’
Page 2
New York Brick Oven Company
N
N e w Y o r k B r i c k O v e n C o m p a n y t h e W o r l d ’ s B e s t O v e n s
1 7 1 8 H y l a n B l v d S t a t e n I s l a n d N e w Y o r k 1 0 3 0 5 ( 7 1 8 ) 9 8 7 - 2 4 2 2
WARNING: DO NOT PACK REQUIRED AIR SPACE WITH INSULATION
The oven must have a minimum 2” clearance to combustibles from all sides. And
24” clearance to combustibles from the oven top. Figure 1
Clearances
Combustible Construction Non Combustible
Back
2’’
2’’
Right Side
2’’
2’’
Left Side
2’’
2’’
Top
24’’
24’’
facade
Only Noncombustible
FRONT FAÇADE AREA MUST BE COMPOSED OF ALL NONCOMBUSTIBLE
MATERAILS, ANY building materials that contact the oven, must be completely
noncombustible and framed with metal studs. Please note that drywall commonly
referred to as “sheet rock” is considered a combustible material and not safe to
use in any contact with oven.
The areas directly above the door way entrance and the entire front of the oven
must be framed completely with noncombustible materials. The front facade is
considered to be the entirety of the oven front: from floor to ceiling of the oven
front and any openings below .The entire area below the oven entrance or any
access louver door if used must be noncombustible. Any façade coverings above
door and to within 12” to the sides of the doors must be constructed with
noncombustible materials. See Figure 2 below next Page
Page 3
New York Brick Oven Company
N e w Y o r k B r i c k O v e n C o m p a n y t h e W o r l d ’ s B e s t O v e n s
1 7 1 8 H y l a n B l v d S t a t e n I s l a n d N e w Y o r k 1 0 3 0 5 ( 7 1 8 ) 9 8 7 - 2 4 2 2
Figure 2
Install this oven only on a non-combustible floor, which extends at least 36” in
front of and 30” to either side of the door. If you are enclosing the oven front be
sure to leave room for listing marks attached to motor box door.
Air space clearance is required between the bottom of the oven and any wood
storage container. The air space is important to keep the oven working properly
never completely enclose the oven bottom. An access of 36’’ x 36’’ min wide
open is needed to service the oven and allow proper air flow to the oven.
The Minimum clearance between two ovens is 4’’
Wood Storage area is not recommended at oven bottom.
If the oven installation uses a Type 1 Hood, there must be a minimum of 3 inches
of clearance between the hood and any combustible surface.
Page 4
New York Brick Oven Company
N
N e w Y o r k B r i c k O v e n C o m p a n y t h e W o r l d ’ s B e s t O v e n s
1 7 1 8 H y l a n B l v d S t a t e n I s l a n d N e w Y o r k 1 0 3 0 5 ( 7 1 8 ) 9 8 7 - 2 4 2 2
Ventilation
This information is provided to assist in safe and functional installation of all New
York Brick Oven ovens. All oven models must be installed in accordance with all
relevant local and national codes, and in a manner acceptable to the local
authority having jurisdiction.
It is never appropriate to use "B vent" in any part of an exhaust system
connected to any New York Brick Oven Models. Due to the possibility of sparks
entering the duct, exhaust systems serving Solid Fuel equipment SHOULD NOT
be combined with exhaust systems serving other (non-solid- fuel) cooking
equipment. Submit you venting plans to your local authorities before proceeding
with your installation, as there may be additional requirements in your area.
There are two venting options for all New York Brick Oven Model ovens.
These methods are Direct Connection of a Grease Duct or UL103 Type HT listed
chimney (Direct Venting) and a Type 1 Exhaust Hood installed according to
NFPA 96 and the UMC with Grease Duct venting.
VERY IMPORTANT! SUBMIT ALL VENTING PLANS TO LOCAL CODE AUTHORITIES
BEFORE PROCEEDING WITH INSTALLATION.
Most cities accept the U.L. listed Direct Connection method; however a few cities
may require the use of a Type I grease hood over the oven opening and vent.
Check with your local building department to determine which method or
methods are acceptable follow all codes.
Direct Connection Venting For all Models Listed UL103 Type
HT or Grease Duct/Building Heating Appliance Chimney may be connected to
the integral steel vent opening at the top of the oven. A field built grease duct,
constructed and installed to the specifications of a grease duct as detailed in
NFPA 96 or the International Mechanical Code, may also be used. For Grease
Duct installation requirements refer to the Selkirk Metalbestos Model PS and IPS
Grease Duct Installation Instructions or Metal-Fab IPIC Installation Instructions.
For UL103 Commercial Oven Installation and Operation Manual.
Type-1 Exhaust Hood. Type-1 Exhaust Hood Installed per NFPA 96. If
required, a Type 1 hood can be installed above the oven opening. This
installation method meets the standard for ventilation control and fire protection
for commercial cooking operations.
Page 5
New York Brick Oven Company
N e w Y o r k B r i c k O v e n C o m p a n y t h e W o r l d ’ s B e s t O v e n s
1 7 1 8 H y l a n B l v d S t a t e n I s l a n d N e w Y o r k 1 0 3 0 5 ( 7 1 8 ) 9 8 7 - 2 4 2 2
The grease filters must be positioned at the rear of the exhaust hood and must
be of the steel baffle type (Mesh type grease filters must not be used).
The front of the exhaust hood must set forward 20” from the front of the oven
face. The face of the filter must be a minimum of 42 inches from the oven hearth
per the Uniform Mechanical Codes. (UMC) or 48” per NFPA 96. The sides of the
exhaust hood must extend a minimum of 6” to either side of the oven door
openings.
There must be a minimum of 3 inches of clearance between the hood and any
combustible surface
Always refer to the exhaust hood manufactures recommendations for
inspection maintenance and cleaning.
FIRE SUPPRESSION Check with your local code officials to see if fire
suppression is required in your area. If fire suppression is required, you must
vent the oven using a Type 1 hood, constructed and installed in accordance with
NFPA 96. Use Listed Exhaust hoods for our ovens that are pre-piped for ANSUL
R-102 fire suppression. We do not recommend aiming any fire suppression
nozzles into the cooking chamber of the oven. All installations are subject to the
approval of the local authority having jurisdiction.
IMPORTANT SAFETY CONSIDERATIONS Creosote
Formation and need for removal. When wood is burned slowly, it produces
tar and other organic vapors that combine with expelled moisture to form
creosote Solid-fuel exhaust contain creosote and other substances that
accumulate in ducting, creating a risk of fire. The creosote vapors condense
in a relatively cool oven flue and exhaust hood of a slow burning fire.
The accumulation will vary with respect to flue gas temperature, wood type and
moisture content. When ignited, this creosote makes an extremely hot fire.
Frequent, regularly scheduled, thorough flue cleaning is the best way to minimize
the risk of flue fires. The flue should be inspected at least twice a year to
determine the rate of creosote buildup. When creosote accumulates, it should be
removed to reduce the risk of fire. Always refer to local codes for cleaning
schedules that are mandatory and applicable.
PROPER AIRFLOW (Gas Models MARKED “G” or “GW)
Building your oven into a decorative enclosure can create the potential for
venting problems and can result in poor burner performance.
The basic airflow guidelines to follow regarding oven venting that will help ensure
proper operation and performance of Burner systems
Page 6
New York Brick Oven Company
N
N e w Y o r k B r i c k O v e n C o m p a n y t h e W o r l d ’ s B e s t O v e n s
1 7 1 8 H y l a n B l v d S t a t e n I s l a n d N e w Y o r k 1 0 3 0 5 ( 7 1 8 ) 9 8 7 - 2 4 2 2
Venting Continued
Guide Lines to Follow.
1 The ONLY opening for air to enter the space beneath the oven should be at the
front of the oven. This will eliminate the chance of air movement or cross drafts
beneath the oven that can disrupt the oven burner system. You must enclose the
oven in accordance to clearances this clearance. A 36’’ x36’’ opening from the
floor up at the center of the legs is required for air flow.
2 DO NOT block the flow of air underneath the oven. It is necessary to provide
combustion air to the oven burner systems to function properly. If louver doors
are to be used they need to be noncombustible.
3. DO NOT install an enclosure around the oven chamber that has two air intake
openings. Air moving equipment outside the oven enclosure can create a low
pressure zone that can result in air movement that can disrupt proper operation.
Page 7
New York Brick Oven Company
N e w Y o r k B r i c k O v e n C o m p a n y t h e W o r l d ’ s B e s t O v e n s
1 7 1 8 H y l a n B l v d S t a t e n I s l a n d N e w Y o r k 1 0 3 0 5 ( 7 1 8 ) 9 8 7 - 2 4 2 2
Gas Specifications
Gas Specifications (gas models MARKED “G “OR ‘GW”)
All New York Brick Oven Models are equipped with a 1/2" NPT gas connection.
Have a licensed gas installer provide the hook-up and test all fittings and pipe
connections for leaks. Use approved gas leak detectors (soap solutions or
equivalent) over and around the fittings and pipe connections.
The burner manifold pressures have been adjusted and tested at the factory. A
variety of factors can influence these pressures, so be sure to test the individual
burner manifold pressures and adjust the valves as necessary to achieve the
required pressures. Note: The gas valves are shipped in the 'on' position.
Gas Supply Pressure
Natural Gas: 5 to 8 inches WC
Propane (LP): 12 to 15 inches WC LP (Propane) Use The gas supply must be turned
off at the L-P gas supply cylinder when this appliance is not in use.
the gas supply must be capable of providing at least 116,000 BTUs at listed
pressures. 171,000 for propane
The New York Brick Oven Company recommends that the appliance’s individual
shutoff valve (supplied by others) be left readily accessible. The New York Brick
Oven Company also recommends that inspection and maintenance of the
burners and gas piping connections of this appliance be performed at regularly
scheduled intervals and only by professional gas appliance service agencies.
Gas Code Limitations
The installation of this appliance must conform with local codes, or in the
absence of local codes, with the National Fuel Gas Code, ANSI Z223.1, /NFPA 54
The Natural Gas installation Code CAN/CGA-B149.1 or the Propane Installation
Code, CAN/CGA-B149.2, as applicable including:
The appliance and its individual shutoff valve (supplied by others) must be
disconnected from the gas supply piping system during any pressure testing of
that system at test pressures in excess of 1/2 psi (3.45 kPa).
The appliance must be isolated from the gas supply piping system by closing its
individual manual shutoff valve (supplied by others) during any pressure testing
of the gas supply piping system at test pressure, equal to or less than 1/2 psi
(3.45 kPa).
Page 8
New York Brick Oven Company
N
N e w Y o r k B r i c k O v e n C o m p a n y t h e W o r l d ’ s B e s t O v e n s
1 7 1 8 H y l a n B l v d S t a t e n I s l a n d N e w Y o r k 1 0 3 0 5 ( 7 1 8 ) 9 8 7 - 2 4 2 2
This appliance is capable of operating with natural gas
or propane
How to Switch from Natural Gas to Propane
The small screw cap located inside the Gas Burner System on the Venture burner can
be set by simply turning the valve to the left for Propane LPG or right for Natural Gas
Page 9
New York Brick Oven Company
N e w Y o r k B r i c k O v e n C o m p a n y t h e W o r l d ’ s B e s t O v e n s
1 7 1 8 H y l a n B l v d S t a t e n I s l a n d N e w Y o r k 1 0 3 0 5 ( 7 1 8 ) 9 8 7 - 2 4 2 2
.
Page 10
New York Brick Oven Company
N
N e w Y o r k B r i c k O v e n C o m p a n y t h e W o r l d ’ s B e s t O v e n s
1 7 1 8 H y l a n B l v d S t a t e n I s l a n d N e w Y o r k 1 0 3 0 5 ( 7 1 8 ) 9 8 7 - 2 4 2 2
Electrical Specifications Form Gas Models Electrical diagrams
are located on the motor control box center directly at bottom of oven.
Have a licensed electrician install (1) 115V- 15 amp outlet with proper
grounds and (1) 115V-NEMA L530R 30 amp separate line.
Electrical Code Limitations
ELECTRICAL GROUNDING: This appliance must be electrically grounded in
accordance with local codes, or in the absence of local codes, with the National
Electrical code, ANSI/NFPA 70.
WARNING
Electrical Grounding Instructions
This appliance is equipped with 2 three-prong (grounding) plug for your
protection against shock hazard and should be plugged directly into a
properly grounded three-prong receptacle. Do not cut or remove the
grounding prong from these plugs.
Page 11
New York Brick Oven Company
N e w Y o r k B r i c k O v e n C o m p a n y t h e W o r l d ’ s B e s t O v e n s
1 7 1 8 H y l a n B l v d S t a t e n I s l a n d N e w Y o r k 1 0 3 0 5 ( 7 1 8 ) 9 8 7 - 2 4 2 2
OPERATING AND MAINTENANCE INSTRUCTIONS
Operations FIRING THE OVEN
The Gas or Wood Fired Pizza Oven is an open hearth appliance designed to
cook with high heat and a live fire. The oven may be utilized for a variety of
cooking techniques such as high heat roasting, as a bake oven and of course a
pizza oven. No matter what style of cooking you intend on using, the oven must
always be pre-heated and then regulated to the desired operating temperature
following these instructions. The Oven is a High temperature oven and is not to
be considered for cooking below 500f.
WARNING
READ ALL INSTRUCTIONS CAREFULLY. IMPROPER USE
OF THIS APPLIANCE MAY RESULT IN A BUILDING FIRE
OR PERSONAL INJURY. INSTRUCTIONS SHOULD BE
THOROUGHLY UNDERSTOOD BY ALL OPERATING AND
SUPERVISING PERSONNEL.THIS OVEN IS INTENDED FOR
OPERATION BY TRAINED AND QUALIFIED PERSONNEL
ONLY.DO NOT OVER FIRE. IF FLAMES EXTEND BEYOND
THE OVEN DOOR OPENING, YOU ARE OVER-FIRING.DO
NOT USE PRODUCTS NOT SPECIFIED FOR USE WITH
THIS OVEN.NEVER USE WATER OR ICE TO LOWER
TEMPERATURE INSIDE THE OVEN DO NOT LOAD OVEN
WOOD CHAMBER PAST THE HIEGHT OF THE STEEL
SUPPORT LOGS. DO NOT PLACE WOOD ON REVOLVING
FLOOR.
Page 12
New York Brick Oven Company
N
N e w Y o r k B r i c k O v e n C o m p a n y t h e W o r l d ’ s B e s t O v e n s
1 7 1 8 H y l a n B l v d S t a t e n I s l a n d N e w Y o r k 1 0 3 0 5 ( 7 1 8 ) 9 8 7 - 2 4 2 2
Correct Hight of wood at Maximum loading Do Not Stack Hire Then Steel Rods.
Wood Only Ovens -Models Designated With: W
Use only dry seasoned medium or hard woods in wood chamber area.
Open small wood door with glass window by handle. Place small amount
of kindling in fire pit area directly on the grate light with gas match. As fire
begins to catch add more kindling until a small bed of lit coals begins to
form. Then add dry seasoned med split or hard fire wood. Add one piece
at a time until they ignite. Add more wood as needed to reach oven
temperatures. The oven will take approximately 1.5 hours to reach proper
cooking temperatures for wood fire cooking only. Continue to feed logs as
needed to keep the fire lit. At Nights End let fire die out naturally do not
extinguish with water. Close both doors one for the fire entrance and one
for pizza loading door. Then close heat shields to keep all radiant heat in
the oven. How To Monitor Wood oven temperature The Best method
is to use an-“Inferred Laser Temperature Monitoring Gun, the Gun
should be able to read up to 750 f. .Check revolving deck
temperature and dome temperatures to assure correct cooking
temperatures. The two surfaces will vary due to the fact that heat
rises. Find your perfect operating floor temperature and continue to
add wood as needed to keep the cooking cycle regulated.
For Gas/ Wood Model: Designated With “ G-WD:GAS WOOD Turn on oven
Gas with front loading door removed, (See Operation of Gas Burner System
page ) It is never recommended to use oven door while gas is in use The oven
door can be placed on mantel after ignition of flames but always open 1 “ or
more. Place dry seasoned logs in wood chamber area. Close wood door and let
wood dry out until ignition of wood. If wood continues to smolder use a small
piece of paper put directly on wood to ignite. Add wood as needed to maintain
the fire. Do not over stuff oven with wood or place any wood on revolving floor.
Wood use with gas ovens should be minimal just to keep flame lit in wood
chamber. At Nights End let fire die out naturally do not extinguish with water.
Close both doors one for the fire entrance and one for pizza loading door. Then
close heat shields to keep all radiant heat in the oven.
Page 13
New York Brick Oven Company
N e w Y o r k B r i c k O v e n C o m p a n y t h e W o r l d ’ s B e s t O v e n s
1 7 1 8 H y l a n B l v d S t a t e n I s l a n d N e w Y o r k 1 0 3 0 5 ( 7 1 8 ) 9 8 7 - 2 4 2 2
Disposal of Ashes Ashes are to be removed from ash dump draw. Pull out
draw and be sure to place ashes directly in fire proof metal container with a tight-
fitting lid. The closed container of ashes should be placed on a non-combustible
floor or on the ground, well away from all combustible materials, pending final
disposal. When the ashes are disposed by burial in soil or otherwise locally
dispersed, they should be retained in the closed container until all cinders have
thoroughly cooled. Ashes should be cleaned out daily to keep oven working
properly. Ashes should be dumped daily.
.
Page 14
New York Brick Oven Company
N
N e w Y o r k B r i c k O v e n C o m p a n y t h e W o r l d ’ s B e s t O v e n s
1 7 1 8 H y l a n B l v d S t a t e n I s l a n d N e w Y o r k 1 0 3 0 5 ( 7 1 8 ) 9 8 7 - 2 4 2 2
Understanding and Operating the Gas Controls
For All Gas Model Units Designated With A “G” Or GW Gas
or Gas- Wood Combinations
All New York Brick Ovens come equipped with the “Spitfire” gas system designed
specifically for baking great pizza. The table below shows all functions and
controls of the oven. The Burner systems are factory preset for proper
performance for your particular oven.
Page 15
New York Brick Oven Company
N e w Y o r k B r i c k O v e n C o m p a n y t h e W o r l d ’ s B e s t O v e n s
1 7 1 8 H y l a n B l v d S t a t e n I s l a n d N e w Y o r k 1 0 3 0 5 ( 7 1 8 ) 9 8 7 - 2 4 2 2
The Spitfire gas burner system is a sophisticated gas controller that can be
used in either a Manual or Automatic mode or with a Set Point. In addition, the
size of the flame can be regulated independently of the oven temperature.
Explanation of Gas Controls The System Power button (located in the
bottom right corner of the burner control panel ) Is to be turned on first.
POWER BUTTON (1)
The power switch is the button in the top left corner of the control box. A green
light will be illumined when the burner is on.
OVEN TEMPERATURE (4)
The oven temperature is display with LED numbers in the middle of the control
box. The Spitfire burner system reads the oven temperature in front of the burner
using a thermal couple. While this number is accurate, it is primarily used as
A guide for setting the burner not for cooking. See Cooking Environments for
details.
SET POINT (10)
The Set button is pressed to change the ‘Target temperature’ or set point of the
burner when in Auto mode. Press Set and then use the up and down arrows to
change the set point. Press set again to lock in the set point. The Spitfire burner
will automatically raise and lower the flame to maintain that temperature.
NOTE: The actual temperature inside the oven will be different than the
temperature displayed on the control box. This Set Point should be used in
conjunction with an infrared thermometer to balance the oven for the desired
cooking environment. Test various set points in 20 degree increments to
determine the set point that achieves the desired floor temperature.
RESET BUTTON (15)
If the oven loses its flame, the Reset button will be illumined. Press the Reset
button to relight the burner.
If the burner goes out three times in a row contact The New York Brick Oven
Company service department to help rectify the problem.
FIRE CONTROL (16-6)
The size or intensity of the flame can be changed by pressing the up or down
arrows to achieve the desired flame.
MAX BUTTON (7)
Press the Max button to allow the oven to run at maximum power. The flame can
be adjusted manually by using the Fire Control up and down arrows.
AUTO BUTTON (9)
Press the Auto button to manage the oven based on the set point. See Set Point
for details.
Page 16
New York Brick Oven Company
N
N e w Y o r k B r i c k O v e n C o m p a n y t h e W o r l d ’ s B e s t O v e n s
1 7 1 8 H y l a n B l v d S t a t e n I s l a n d N e w Y o r k 1 0 3 0 5 ( 7 1 8 ) 9 8 7 - 2 4 2 2
MIN BUTTON (17)
Press the Min button to run the oven with the smallest flame. Use this mode
when pre-heating an oven or
To keep a hot oven stable between lunch and dinner service
Note To use the oven in accordance with NSF/ANSI Standard 4, only pizza and
bread products may be cooked directly on the floor of the oven. Other types of
food may be cooked in the oven but only in pans, pots trays or other suitable
containers to prevent spillage onto the oven deck
DAILY OPERATIONS
The goal for daily service is to have an oven that is pre-heated with a live flame.
With cooking temperatures regulated to provide you with ease of operation and a
cooking environment that works with your operation. The oven can be used in the
Manual mode or in the Automatic mode by pressing the appropriate buttons.
Either mode requires a handheld infrared thermometer set to read Fahrenheit to
Accurately read the floor temperature where you are cooking. The floor
temperature will vary from the dome temperature that is normal operation for all
high temperature ovens.
DAILY START UP
Remove oven door and remove any debris using the floor brush.
PRE-HEAT OVEN (1) Press the power button to turn the oven on. The ambient
air temperature is shown in Fahrenheit.
AUTOMATIC MODE (9)
Press the Auto button to put the oven in automatic mode. The oven will now self-
regulate according to the ‘Target Temperature’ or set point. Pressing the
Set button will display the set point. Press and hold the Set button to change the
set point using the up and down arrows. Press set again to lock in the set
point. Remember, the set point is used to regulate the burner and is not an
accurate measurement of the cooking surface so just use it as a guide.
Perfection comes with practice!
MANUAL MODE (17) Press the Min button to fire the oven with the lowest flame
setting.
Press the Max button (7) to fire the oven with the highest flame setting.
Use the up and down arrows to ramp the flame up or down to the desired size.
Spitfire rates the size of the flame as a percentage of the maximum flame.
NOTE: At any time you may press the up and down arrows to change the size of
the flame.
Page 17
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35

New York Brick Oven Company 140-GW–WD-G Operating instructions

Category
Ovens
Type
Operating instructions
This manual is also suitable for

The New York Brick Oven Company 140-GW–WD-G is a commercial oven that has been tested to UL Subject 2162 and ANSI Z83.11 standards. It is a solid fuel/gas oven that is designed for use in food service establishments. The oven has a number of features that make it a good choice for commercial use including:

  • It is made of durable materials that are designed to withstand the high temperatures and heavy use that is common in commercial kitchens.
  • It has a large cooking capacity, which makes it ideal for cooking large batches of food.
  • It has a variety of cooking modes, which gives you the flexibility to cook a wide range of foods.