knudsen Chirp 3204 User manual

Type
User manual

This manual is also suitable for

CHIRP 3200 SERIES
USER MANUAL
D101-05530
Revision 1
Knudsen Engineering Limited
10 Industrial Road
Perth, Ontario, Canada
K7H 3P2
Phone: 613-267-1165
Fax: 613-267-7085
www.knudsenengineering.com
info@knudsenengineering.com
CONTENTS
1 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.1 About this manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.2 Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.3 Unpacking Shipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2 DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2.1 System Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2.2 Physical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3 INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3.1 System Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3.2 Software Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3.3 Connector Panel Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
3.3.1 Input Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
3.3.2 Analog Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
3.3.3 Sync In / Out . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
3.3.4 Transmit (TX) Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
3.3.5 USB Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
3.4 System Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3.4.1 Peripherals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3.4.2 Data Logging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3.5 Transducer Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3.5.1 Over-the-Side . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3.5.2 Through Hull . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3.5.3 Sea Chest . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
4 SYSTEM OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
4.1 Factory Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
4.2 Basic Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
4.2.1 Shallow Water Hints . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
4.2.2 Deep Water Hints . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
5 TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
5.1 Power Indicator is Off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
5.2 No Output to Transducer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
5.3 No Connection to PC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
6 CABLE CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
D101-05530 2 of 11
1 INTRODUCTION
1.1 About this manual
This manual describes the basic setup and operation of the Chirp 3200 Series Echosounder and includes the 3200,
3202, and Chirp 3204. For more detailed operation of the SounderSuite software package please download the
Software User’s Manual from the website listed below.
1.2 Technical Support
For technical support or to report problems please contact your local representative or:
Technical Support
Knudsen Engineering Limited
10 Industrial Road
Perth, Ontario
K7H 3P2
Voice: (613) 267-1165 8:30 am to 5:00 pm E.S.T. Core Hours
Fax: (613) 267-7085
E-Mail: support@knudsenengineering.com
WebSite: http://knudsenengineering.com/
1.3 Unpacking Shipment
The Chirp 3200 Series Echosounder is securely packed in a plastic shipping/storage case. In the standard
shipment will be the following items:
! Chirp 3200 Series Echosounder
! AC power cable
! Transducer cable connectors (unless already installed on transducers)
! USB cable
! SounderSuite Software CD-ROM
D101-05530 3 of 11
2 DESCRIPTION
2.1 System Overview
The Chirp 3200 Series Echosounder can be configured with up to four channels (Chirp 3204) with two of the
channels capable of up to 2kW of output power and two capable of up to 1kW of output power.
2.2 Physical Characteristics
The Chirp 3200 Series Echosounder is housed in a standard 3U rack case. A summary of significant dimensions
and weights of the Echosounder follows:
Length 533 mm
Width 483 mm
Height 133 mm
Weight 11kg
D101-05530 4 of 11
3 INSTALLATION
The Chirp 3200 Series Echosounder is housed in a standard 3U rack case. It can be installed to the rack using the
provided mounting holes on the front panel (dimensions shown below). It is also recommended to use rack
supports, especially with the Chirp 3204 Quad Channel system.
It is recommended, but not mandatory, to provide clearance above and below the Chirp 3200 installation in the
rack for ventilation.
3.1 System Overview
The Chirp 3200 is a “black box” echosounder that utilizes a PC to allow the user to control all system parameters,
manage peripherals, record entire echogram data, as well as internal and external data logging. The
communication link from the Chirp 3200 to the PC is via USB (full speed 2.0).
3.2 Software Installation
Once installed in the CD-ROM drive of your PC the SounderSuite-USB installation wizard will guide the user
through the installation. For a more detailed explanation of the entire software installation please refer to the
following manual:
SounderSuite - USB Windows Installation and Firmware Upgrades (part number D101-04383)
D101-05530 5 of 11
3.3 Connector Panel Overview
The image below shows the connector panel located on the rear of the Chirp 3200 Series Echosounder. This image
is for a Chirp 3202 Dual Channel system with the possible expansion ports to upgrade to a Chirp 3204 Quad
Channel system.
3.3.1 Input Power
The Chirp 3200 needs to be powered from a AC source. The input voltage range is 90-264 VAC (nominal
120VAC). The power consumption of the Chirp 3202 is 60W and the Chirp 3204 is 100W.
3.3.2 Analog Output
These are standard BNC connections which provide direct access to the analog signal after bandpass anti-aliasing
filters. This interface is useful for oscilloscope viewing of the output signal. The expected signal levels are between
0-5 volts.
3.3.3 Sync In / Out
The Sync In allows the output transmit of the Chirp 3200 to be synced to another piece of equipment. The SYNC
IN looks for a high-to-low-to-high transition with a low cycle hold time of at least 1ms but less than 50ms (min
ping rate). The transmit will occur on the rising edge on the sync signal. The SYNC OUT will provide a signal
from Channel 1.
3.3.4 Transmit (TX) Output
The TX Output connection transfers the high voltage transmit output signal to the transducer as well as the return
echo to the echosounder. CAUTION: Make sure that the Chirp 3200 is not transmitting while connecting or
disconnecting the transducer to the Tx Output connection.
3.3.5 USB Interface
D101-05530 6 of 11
The USB interface provides communication from the Chirp 3200 to the PC. It is a full speed 2.0 (12Mbps)
connection. The connection will mate with any standard USB cable.
3.4 System Connection
3.4.1 Peripherals
All peripherals are connected directly to the PC and the setup for each is via the EchoControl Client software
application.
3.4.2 Data Logging
Same as the peripherals, any connection to an external data logger is done through the PC. There also is the
capability to run the data logging package on the same PC that your EchoControl software is operating on.
3.5 Transducer Installation
The correct transducer installation is essential to maintain good system performance. Three are three common
types of transducer installations:
1) Over-the-side
2) Through Hull
3) Sea Chest
3.5.1 Over-the-Side
The method of mounting the transducer over the side of the boat is primarily used for temporary installations. This
usually entails the transducer mounted to the end of a pole that is fastened to the side of the boat. The majority of
the transducers that are sold by Knudsen Engineering Limited have the option to be purchased with a mounting
adapter. The adapter provides a small mounting stem made of a 1-1/4" aluminum pipe with a standard pipe thread.
The longer pipe and the means to fasten it to the boat are not provided as they change with every installation. It is
very important that the transducer will be completely submerged below the water surface at all times.
3.5.2 Through Hull
A more permanent means of mounting the transducer is through the hull. This will require modifications to be
made to the hull of the boat. The face of the transducer will become the “wet end” in direct contact with the water
and the cable end of the transducer will become the “dry end” inside the hull of the boat. The location of where the
transducer goes through the hull has to be selected to prevent any type of aeration coming in contact with the
transducer face. Any modifications that are to be done to the boat to install the transducer through the hull should
be made by a qualified individual.
D101-05530 7 of 11
3.5.3 Sea Chest
Another permanent means of transducer installation in using a sea chest. The chest is located on the inside of the
hull and the transducer transmits and receives either through the hull itself or through an acoustic window. The sea
chest will need to be filled with water and may need a stand pipe to provide proper pressure to the transducer to
avoid cavitation. The following illustration is an example of a sea chest transducer installation.
D101-05530 8 of 11
4 SYSTEM OPERATION
Your PC will automatically recognize the Chirp 3200 upon power up. The SounderSuite installation CD will have
installed applications shortcuts to the desktop of the PC. The EchoControl Server application needs to be started
first and once running a “K” will appear in the task bar. After the EchoControl Server is running the EchoControl
Client application can be started. NOTE : Running EchoControl Client will auto-run EchoControl Server. For a
complete explanation on the operation of the EchoControl Server and EchoControl Client please refer to the
following manual:
SounderSuite - USB EchoControl Client (part number D101-04380)
4.1 Factory Setup
The Chirp 3200 features up to four frequency agile channels that the user can configure to any frequency between
3.5 and 210kHz. The system’s operating frequencies will be preset at the factory to match a specific transducer,
either supplied with purchase or requested by purchaser.
4.2 Basic Controls
For a complete explanation of all EchoControl Client controls please refer to the following manual:
SounderSuite - USB EchoControl Client (part number D101-04380)
Some of the basic controls that the user will need to understand to operate the Chirp 3200 are Tx Power, Gain,
Pulse Length, Range, Phase, and Tx Blanking.
The Tx Power, Gain, and Pulse Length directly affect the strength of the output signal and thus the return echo.
There are four power settings each approximately 25% of the configured total output power. The Gain can be
selected manually or automatically (recommended). Shorter pulse lengths are to be used in shallow waters and
longer pulse lengths in deeper water. Longer pulse lengths may be used in shallow water if the user is sub-bottom
profiling.
The Range and Phase settings will tell the echosounder what the extents of the search window are. The Range
determines the size of the search window and the Phase determines where in the water column to search. For
example: (assuming Meters as units) Range 100 Phase 1
The search window will be from 0 to 100M. If the Phase changes to 2 the search window will shift down the water
column and now be 50-150M. The same amount of information (100M) remains as the Range did not change.
There is an AutoPhase control that will allow the echosounder to change to the proper phase as the bottom
approaches either extent of the search window.
The Tx Blanking setting allows the user to block out any transducer ringing near the surface that may appear as a
return and possibly confuse the system’s bottom tracking. The Tx Blanking can be set by observing the amount of
ringing present on your data when in a primary search window (0-10, 0-50, etc).
4.2.1 Shallow Water Hints
For operation in shallow water set the Power setting to 1 or 2. Set the Gain to AGC (Automatic Gain Control) and
set the pulse length to its lowest setting. Make sure that the Tx Blanking settings is at a level that will function in
your desired water depth. Set your Phase to 1 and your range to a level just larger than your desired water depth.
D101-05530 9 of 11
4.2.2 Deep Water Hints
For operation in deeper water you need to increase your Power to a level of 3 or 4. Leave the Gain set to AGC and
increase your pulse length. The Tx Blanking setting should also be increased as the higher power and longer pulse
lengths will increase the transducer ringing.
5 TROUBLESHOOTING
5.1 Power Indicator is Off
Confirm proper input voltage applied to echosounder. If the input is okay then connect to PC to confirm operation.
It may be that the LED has failed. If problem continues, contact Knudsen Engineering Limited.
5.2 No Output to Transducer
Confirm that the proper transducer has been connected to the echosounder. Then check the transducer cable for
any bends, breaks, or other visible damage.
5.3 No Connection to PC
The Chirp 3200 will be automatically recognized by Windows upon successful communication. If the Power
Indicator is ON but the system is not recognized by the PC then first try changing USB cables and then try a
different USB port on the PC. If the problem continues, contact Knudsen Engineering Limited.
D101-05530 10 of 11
6 CABLE CONNECTIONS
Input Power
Pin L - Line
Pin N - Neutral
Pin G - Ground
Transmit Output
Pin A: Out +
Pin B: Shield
Pin C: Out -
Mating Cable End
Manufacturer: AMPHENOL
Part Number: MS3476W12-3P
USB
Pin 1: Power
Pin 2: Data +
Pin 3: Data -
Pin 4: Shield
L
N
G
A
B
C
Front View
D101-05530 11 of 11
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11

knudsen Chirp 3204 User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI