Anolis Ambiane AP User manual

Type
User manual

Anolis Ambiane AP is a versatile LED lighting fixture designed for indoor use, offering a range of features for professional lighting applications. It boasts high-power LEDs, various control options, and adjustable color temperature, making it suitable for a variety of settings. With its compact design, easy installation, and energy efficiency, the Ambiane AP provides a reliable and flexible lighting solution.

Anolis Ambiane AP is a versatile LED lighting fixture designed for indoor use, offering a range of features for professional lighting applications. It boasts high-power LEDs, various control options, and adjustable color temperature, making it suitable for a variety of settings. With its compact design, easy installation, and energy efficiency, the Ambiane AP provides a reliable and flexible lighting solution.

1
User manual
Ambiane AP (RGBW, RGBA, TD, PW, TW)
The unit generates light by means of high power LEDs. The unit was designed for indoor use only.
1. Attention
 Theunitmustbeinstalledbyaqualiedelectricianinaccordancewithall
 nationalandlocalelectricalandconstructioncodesandregulations.
The unit was designed for indoor use only.
AvoidlookingdirectlyintotheLEDlightbeamatcloserange!
 Donotinstalltheunitnearhighlyinammableliquidsormaterials.
Do not allow anything to rest on the unit.
 Donotinstalltheunitnearanopename.
 Donotinstalltheunitindirty,dustyorbadlyventilatedlocation.
 Sucientairaccessingtothehousingoftheunithastobeensured,
there must not be any heat or anti-noise insulation within a 0.6m x 0.6m
 areaaroundtheunit(non-ICratedxture).
ImmunityoftheequipmentisdesignedforelectromagneticenvironmentsE1,E2,E3
 accordingtothestandardEN55103-2ed.2Electromagneticcompatibility.Productfamily
 standardforaudio,video,audiovisualandentertainmentlightingcontrolapparatusfor
 professionaluse.Part2:Immunity.
 Theproduct(coversandcables)mustnotbeexposedtoahighfrequencyelectromagneticeldhigher
 than3V/m.
 Theinstallationcompanyshouldchecklevelsofpossibleinterferencesabovethetestedlevels
 E1,E2,E3givenbythisstandard(e.g.transmittersinsurroundingarea)beforeinstallingtheequipment.
 EmissionoftheequipmentcomplieswiththestandardEN55032Electromagneticcompatibility
 ofmultimediaequipment–EmissionRequirementsaccordingtoclassB.
Suitableforfasteningon   Unsuitableforcoveringbyheatinsulation
 non-ammablesurfacesonly  material
Always switch o power supply of the unit before connecting or disconnecting the unit
2
2. Installation
1.Prepareacircularopeninginthelowerceiling(1)asshowninthepicturebelow.
2.InserttheAmbianeAPunitintotheopening.FastentheAmbianeAPbymeansoftwospringfasteners(2)
to the opening.
3.ConnectneededcablestotheAmbianeAP.Connectionblocks(4)areplacedonthePCBRB3727(3).The
PCBisunderplasticcover(5)whichisfastenedbymeansoftwoscrews(6).
Theprimarypowerinputservesforastandardpower(e.g.PowerSupplyforAmbianeAP).
Thesecondarypowerinputservesforabackuppower(incasethatprimarypowerfailed).
Ifbothpowerinputsareundervoltage,theprimarypowerhasapriorityandthesecondarypowerisdisabled.
Incaseofprimarypowerloss,thesecondarypowerisenabled.
IftheAmbianeAPissuppliedviathesecondarypower,thelightintensitycanbesetbythetrimmer(9).
TheAmbianeAPcanbecontrolledbyoneofthefollowingmethods:DMX512
DALI
        0-10V(AmbianePW,AmbianeTDonly)
TheAmbianeAPisequippedwithtwoDMXandDALIconnectionblocksforeasyconnectiontoDMXorDALI
chain(In/Outmethod).
3
DMX connection 0-10V connection Power connection
PCB Function PCB Function PCB Function
0V- Shield    0V 0V    + Power+
D+ Signal(+)   D+ +10V    - Power-
D- Signal(-)
RecommendeddiametersofconductorswithrespecttodistancebetweenAmbianeAPandpowersupplyunit
(AmbianePowerAP).
Distance/cable length 50m 100 m
Diameters of conductors 0.5mm21 mm2
3. DMX and DALI address setting and control
TheDIPswitch(7),locatednexttotheconnectionblocks,allowsyoutorunatestlightandswitchtheAmbiane
APtotheupdatemodeincaseofsoftwareupdate.
.
DIP10-ifswitchedtoON=testlight(3200KforRGBWandTWversion)
DIP11-selectionofxturecontrol:OFF=DMX512orDALI,ON=0-10V
DIP12-changefromOFFtoONpositionswitchestheAmbianeAPtotheupdatemode(switchingtotheupdate
modeisnotnecessaryiftheRobeUploaderisusedforAmbianeAPupdate).
DMX control
TheDMXstartaddress,istherstchannelusedtoreceiveinstructionsfromtheDMXcontroller.Theaddress
maybeanychannelfrom1to509.DMXaddresscanbeseteitherbyDIPswitchorbyRDM.DMXaddress
setbyRDMoverwritesaddresssetbyDIPswitchandviceversa.ThegreenLED(8)onthePCBsignalsway
ofDMXaddresssetting:
 LEDlights-DMXaddressissetbymeansoftheDIPswitch.
 LEDdoesnotlight-DMXaddressissetbymeansofRDM.
DIP11hastobesetinOFFposition.
ExampleofDMXaddresses:
DALI control
AddressingoftheAmbianeAPismadebymeansofanexternalDALIcontroller.TheexternalDALIcontroller
hastosendactivatingcommand(8=ON)ifyouneedtostartthepermanentcontroloftheAmbianeAP(Ambiane
4
APwillnotrespondtoDMXcommands)anddeactivatingcommand(0=OFF)tostopcontroloftheAmbianeAP.
DIP11hastobesetinOFFposition.
Note:IfDIP11=OFF(AmbianeAPiscontrolledbyDMXorDALI),therstcomingcommandswitchestheAm-
bianeAPtothecorrespondingoperationmode(DMXoperationbyaDMXcommand,DALIoperationbyaDALI
command).E.g.theAmbianeAPstaysinaDALIoperationandcomingDMXcommandswitchestheAmbiane
APtoDMXoperation.NextcommandisaDALIcommandandswitchestheAmbianeAPtotheDALIoperation
etc.IfyouneedthepermanentDALIoperation,youhavetosendaDALIcommand8totheAmbianeAP.
0-10V control
DIP11hastobesetinONposition.0-10VoperationhasprioritytoDALIcommands.Theoptionisapplicable
forAmbianePWandAmbianeTDonly.
4. RDM
ThisAmbianeAPsupportsRDMoperation.RDM(RemoteDeviceManagement)isabi-directionalcommunica-
tionprotocolforuseinDMX512controlsystems,itisthenewopenstandardforDMX512deviceconguration
and status monitoring.
RDMallowsyoutosetsomeoptionsasDMXaddress,selectDMXmodeandreadoutsoftwareversionofthe
AmbianeAPetc.
ViaRDMyoucanalsosetbehaviourofthextureincaseoflossofDMXsignal.Forthispurposeservethe
followingtwooptions:
DMXhold
 ValueOn(0)-thexturekeepslastreceivedDMXvaluesincaseofDMXloss(defaultsetting).
 ValueO(1)-itactivatestheoption"DMXlost".Tosettheoption"DMXhold"toO,youhavetosend
 avalue1viaRDM.
DMXlost
Theoptionisactiveonlyiftheoption"DMXhold"issetO.
 ValueOn(0)-thexturelightsatmax.lightoutputincaseofDMXloss(defaultsetting).
 ValueO(1)-ThelightoutputofthextureisclosedincaseofDMXloss.Tosettheoption"DMXlost"
 toO,youhavetosendavalue1atRDM.
RDMmodelIDfortheAmbianeAPis0x0114.
Parameter ID Discovery command SET command GET command
DISC_UNIQUE_BRANCH *
DISC_MUTE *
DISC_UN_MUTE *
DEVICE_INFO *
SUPPORTED_PARAMETERS *
SOFTWARE_VERSION_LABEL *
DMX_START_ADDRESS * *
IDENTIFY_DEVICE * *
DEVICE_MODEL_DESCRIPTION *
MANUFACTURER_LABEL *
DEVICE_LABEL * *
SENSOR_DEFINITION *
SENSOR_VALUE *
RESET_DEVICE *
DMX_PERSONALITY * *
DMX_PERSONALITY_DESCRIPTION *
SENSOR_VALUE * *
SENSORDEFINITION *
5
5. Anti-glare ring installation
Inserttheanti-glarering(1)intotheAmbianeAPuntilthreelocks(2)snapintoslots(3).
6. Adapter ring installation
1.Removebothspringfasteners(2)byunscrewingthefourscrewsM4x10(1).
2.Slidetheadapterring(4)ontothehousingoftheAmbianeAP.Screwthenewfasteners(3)onthehousing.
UseoriginalscrewsM4x10(1).
6
7. DMX protocols
Ambiane RGBW , Ambiane RGBA
Version1.2
Mode 1
Channel
Mode 2
Channe
Mode 3
Channe
Mode 4
Channe
Mode 5
Channe Value Function Type of
control
1 1 1 - 1 0-255
Red
RedLEDssaturationcontrol0%-->100% proportional
- - 2- - 0-255
Red Fine
RedLEDssaturationcontrolfrommin.-->max. proportional
2 2 3 -20-255
Green
GreenLEDssaturationcontrol0%-->100% proportional
- - 4- - 0-255
Green Fine
GreenLEDssaturationcontrolfrommin.-->max. proportional
3 3 5 -30-255
Blue
BlueLEDssaturationcontrol0%-->100% proportional
- - 6 - - 0-255
Blue Fine
BlueLEDssaturationcontrolfrommin.-->max. proportional
4-7-40-255
White/Amber
White(Amber)LEDssaturationcontrol0%-->100% proportional
- - 8- - 0-255
White/Amber Fine
White(Amber)LEDssaturationcontrolmin.-->max. proportional
- - 91 -
0
1-127
128
129-255
Green White Fine
Uncorrectedwhite
Minusgreen-->uncorrectedwhite
Uncorrectedwhite(128=default)
Uncorrectedwhite-->plusgreen
step
proportional
step
proportional
- - 10 2-
0
1-10
11-20
21-255
Colour temperature correction (CTC)
Nofunction(default)
Tungstendimming3200K
Tungstendimming(3200K)
Colourtemperaturechanging2700K-6500K
(21=2700K, 64-3200K, 128=4200K, 192-5600K,
255=6500K)
step
step
step
proportional
- - 11 3 5 0-255
Dimmer
Lightintensitycoarse0%-->100% proportional
- - 12 - 6 0-255
Dimmer Fine
Lightintensityfrommin.-->max. proportional
Ambiane PW, Ambiane TD
Version1.1
Mode 1
Channel
Mode 2
Channel Value Function Type of control
1 1 0-255
Dimmer
Lightintensitycoarse0%-->100% proportional
-20-255
Dimmer Fine
Lightintensityfrommin.-->max. proportional
Ambiane TW
Version1.3
Mode 1
Channel
Mode 2
Channel
Mode 2
Channel
Mode 2
Channel Value Function Type of
control
1 - 1 - 0-255
White colour selection
Whitefrom2700K-->4000K proportional
- 1 - 1 0-255
Warm White
WarmWhiteLEDssaturationcontrol0%-->100% proportional
-2-20-255
Cool White
CoolWhiteLEDssaturationcontrol0%-->100% proportional
2 3 2 3 0-255
Dimmer coarse
Lightintensitycoarse0%-->100% proportional
- - 3 4 0-255
Dimmer Fine
Lightintensityfrommin.-->max. proportional
7
8. Technical specications
Inputvoltage:     48VDC
Protectionclass:    CE: (ClassIII)
      ETL:Class2orLVLE
Max.powerconsumption:   50W
Beamangle:     67°,80°withanti-glarering
Colourtemperature:
 AmbianePW    2700K,4000K
 AmbianeTW    2700K-4000K
AmbianeTD    3200K
Control:
 AmbianeRGBW,AmbianeTW  DMX,DALI,RDMcompatible
 AmbianePW,AmbianeTD  DMX,DALI,0-10V,RDMcompatible
DMXchannels:    
 AmbianeRGBW   4(Mode1),3(Mode2),12(Mode3),3(Mode4),6(Mode5)
 AmbianePW,AmbianeTD  1(Mode1),2(Mode2)
 AmbianeTW    2(Mode1),3(Mode2)
TypicalLumenmaintenance:   70%@50,000hours
Ledlifeexpectancy:    minimum50,000hours
Operatingambienttemp.range:  -20°C/+45°C(-4F/+113F)
Operatingtemperature:   75°C@Ambient+35°C(167°F@Ambient+95°F)
Totalheatdissipation:    136BTU/h(calculated)
Cooling:     convection
Housing:     alluminium
Weight:     1.9kg|(4.19lbs)
Installationmethod:    viatwospringfasteners
ICrating:     non-ICrated
Power/DMX/DALIconnection:   terminalblocks
Protectionfactor:    IP20(withoutdiuserglass),IP20/IP54(withDiuserGlass)
AmbianeAPwithoutDiuserGlass   AmbianeAPwithDiuserGlass
9.Included items
1xAmbianeAP
1x Anti-GlareRing(P/N10980386)
1xSetofcableconnectors
1 x User manual
10. Optional Accessories
AmbianePowerAP(P/N10063994)
Anti-GlareRing(P/N10980386)
AdapterRing(235-255mm)(P/N10980388)
8
11. Dimensions
mm[inch]
12. Maintenance
KeeptheAmbianeAPclean,especiallylightsourceandtheribbedhousing.
9
13. Software update
SoftwareupdateofthexturecanbedonebymeansoftheROBEUploader.Itisasoftwareforautomatized
softwareupdateofRobeandAnolisxtures.IttakesadvantageofRDMsupport.
Thextureshavetobeconnectedinadaisy-chain(max.32xtures)andvia
the
RobeUniversalInterface/
RobeUniversalInterfaceWTX
andaUSBcableconnectedtothecontrolPCwiththeRobeUploaderrunning.
ThecontrolPCshouldbeconnectedtotheInternet.
Note:
IfyoudothesoftwareupdatebymeansoftheRobeUploader,switchingxturestotheupdatemode(andfrom
theupdatemode)ismadeautomatically,withoutneedtoswitchtheDIP12toONposition(updatemode).
TheRobeUploadersoftwarecannotbeusedifxturesareconnectedbymeansofDALIconnection.
10
TheRobeUploadersoftwareandusermanualisavailableat:
https://www.robe.cz/robe-uploader/
Version1.8
November22,2021
Specications are subject to change without notice.
Made in CZECH REPUBLIC by ROBE LIGHTING s.r.o. Palackeho 416/20 CZ 75701 Valasske Mezirici
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10

Anolis Ambiane AP User manual

Type
User manual

Anolis Ambiane AP is a versatile LED lighting fixture designed for indoor use, offering a range of features for professional lighting applications. It boasts high-power LEDs, various control options, and adjustable color temperature, making it suitable for a variety of settings. With its compact design, easy installation, and energy efficiency, the Ambiane AP provides a reliable and flexible lighting solution.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI