Johnson Controls UPSPNL550-0 Installation guide

Category
Uninterruptible power supplies (UPSs)
Type
Installation guide
UPSPNL550-0 Panel Installation Instructions
1
Applications
The UPSPNL550-0 provides temporary backup power to computers, networking devices, and other devices of
similar load demand where power interruptions cause outages. The UPS supplies power long enough for
equipment to safely and correctly shut down. Follow all power ratings and load requirement limitations for best
results. Test units periodically for performance compliance because performance degrades with time and the
number of charge and discharge cycles.
North American Emissions Compliance
United States
Canada
Installation and Operation
For details on installation and operation of the CyberPower UPS, refer to the CyberPower User’s Manual on the
inside of the panel door.
Special Tools Needed
Use standard panel mounting tools.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in
a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning the equipment
off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
This Class (B) digital apparatus meets all the requirements of the Canadian Interference-Causing Equipment
Regulations.
Cet appareil numérique de la Classe (B) respecte toutes les exigences du Règlement sur le matériel brouilleur
du Canada.
UPSPNL550-0 Panel
Installation Instructions
24-11092-00007, Rev. A
24- 11092- 00007, Rev. A
Part No. 24-11092-00007, Rev. A
Issued June 2018
(barcode for factory use only)
UPSPNL550-0 Panel Installation Instructions
2
Mounting
Location Considerations
Avoid areas subject to excessive vibrations and the effects of radiant heat.
Ensure that enclosure vents are not blocked or installed in a manner that hinders air flow.
Mount the panel as close as possible to protected equipment. Mount to a suitable solid surface to minimize
vibration and use the designated mounting holes on the back plane of the enclosure.
Wiring
Use the appropriate personal protective equipment, such as gloves and protective goggles. For electrical operation
purposes, use the appropriate electrical protection equipment and tools.
Risk of Electric Shock.
UPS equipment outputs remain live when the main disconnect to the panel is in the Off position or when the panel
is without power. Contact with the UPS equipment outputs can cause electric shock and may result in serious
personal injury or death. To avoid injury, use the appropriate personal protective equipment.
Risque de décharge électrique.
Les sorties des blocs d ’alimentation sans coupure (ASSC) restent alimentées lorsque l’interrupteur principale est
en position Arrêt ou lorsque le panneau est sans alimentation électrique. Tout contact avec les sorties des blocs d
’alimentation sans coupure (ASSC) est susceptible de provoquer un choc électrique et d'entraîner des blessures
graves, voire mortelles. Pour éviter tout risque de blessure, portez l’équipement de protection individuelle
approprié.
Risk of Property Damage.
Do not apply power to the system before checking all wiring connections. Short circuited or improperly connected
wires may result in permanent damage to the equipment.
Risque de dégâts matériels.
Ne pas mettre le système sous tension avant d'avoir vérifié tous les raccords de câblage. Des fils formant un
court-circuit ou connectés de façon incorrecte risquent d'endommager irrémédiablement l'équipement.
UPSPNL550-0 Panel Installation Instructions
3
General Precautions
UPS equipment may continue to supply power at 120 V when power mains are switched off. Only trained
personnel can service this equipment. To reduce the risk of property damage, serious injury, or death, read these
instructions thoroughly and follow all warnings, cautions, notices, and important messages that are included in all
documents that accompany this product.
Johnson Controls shall not assume any liability for injuries or damage caused by not following the steps outlined or
described in these instructions. Unauthorized modifications to Johnson Controls products are prohibited for the
following reasons:
They may create hazards that could result in death, serious injury, or equipment damage.
They void product warranties.
They may invalidate product regulatory certifications.
They may violate OSHA standards.
IMPORTANT: Only qualified personnel should install or service Johnson Controls products. These instructions are
a guide for such personnel. Carefully follow all instructions in this document and all instructions for the CyberPower
UPS.
For power supply requirements, see Technical Specifications
.
Wiring the UPS
To wire the UPS, complete the following steps:
1. Provide a supply voltage to the UPS unit from a qualified source and ensure that the breaker supplying power
is in the off position. Refer to the wire diagram located on the inside of the panel cover.
Note: Ensure that the UPS power cord is plugged into the outlet inside the enclosure. One of the outlets is a
spare. Ensure that the breaker switch inside the panel is in the off position.
2. Wire the supply line voltage to the breaker (hot) and to the terminal block TB-1 (ground and neutral).
3. Wire the field load to TB-2 (hot, neutral, ground) as indicated on the terminal block.
Note: Ensure that the TB-2 wire plug is installed to the surge/battery side outlet of the UPS.
4. While wearing the proper protective apparel, switch the supply breaker to the on position.
5. Switch the breaker switch inside the panel to the on position.
6. Press the power button on the UPS for approximately two seconds and release it after a short beep. A green
light signifies that power is on.
Risk of Property Damage.
Do not run low-voltage cable in the same conduit or wiring troughs with high-voltage wires. Running low- and
high-voltage wires in the same conduit or wiring troughs may damage the equipment or cause system
malfunction.
Risque de dégâts matériels.
Ne pas faire courir un câble basse tension dans les mêmes gaines ou goulottes électriques que des câbles haute
tension. L'installation de fils basse tension et haute tension dans les mêmes gaines ou goulottes électriques
risque d'endommager l'équipement ou de provoquer des dysfonctionnements du système.
UPSPNL550-0 Panel Installation Instructions
4
7. Place the cover on the enclosure. The unit is ready for charging and is able to function as designed after the
proper amount of charging time.
IMPORTANT: See the enclosed CyberPower User’s Manual for the proper charging time, discharge time, load
characteristics, and all other relevant information for the UPS.
Piping
When installing, follow the standard electrical practices per local codes. Make the necessary enclosure conduit
connections using standard tools. You may need to make the conduit entry hole for the field. Do not interfere with
the vents on the side of the unit when making an opening. Ensure that no loose metal filings rest on the internal
components in the enclosure. Remove any containments and clean the inside of the enclosure as needed.
Setup and Adjustments
To set up the panel and UPS, follow the CyberPower User’s Manual, which is included with the enclosure.
Operation
To operate the panel and UPS, follow the CyberPower User’s Manual, which is included with the enclosure.
Repair Information
If the UPSPNL550-0 fails to operate within its specifications, replace the defective component. For a replacement,
contact the nearest Johnson Controls® representative.
Replacing the UPS
To replace the CyberPower UPS, complete the following steps while wearing the appropriate personal protective
equipment:
1. Place the main breaker that is supplying power to the panel in the Off position.
2. Remove the panel cover.
3. Place the breaker inside the panel in the Off position.
4. Turn off the CyberPower UPS by pressing its power button for approximately two seconds. Release it after you
hear two short beeps.
5. Unplug the CyberPower UPS from the AC power outlet inside the panel.
Note: Make a note of the electrical connections.
6. Remove the existing CyberPower UPS unit.
7. Place the new UPS in the panel and install the necessary electrical connections.
8. While wearing the appropriate personal protective equipment, switch the main supply breaker to the On
position.
9. Turn on the breaker that is inside the panel.
10. Press the power button on the CyberPower UPS for approximately two seconds and release it after you hear a
short beep. A green light signifies that power is on.
11. Reinstall the panel cover.
Published in U.S.A. www.johnsoncontrols.com
UPSPNL550-0 Panel Installation Instructions
Metasys® and Johnson Controls® are registered trademarks of Johnson Controls.
All other marks herein are the marks of their respective owners. © 2018 Johnson Controls.
Building Technologies & Solutions
507 E. Michigan Street, Milwaukee, WI 53202
5
European Single Point of Contact: NA/SA Single Point of Contact: APAC Single Point of Contact:
JOHNSON CONTROLS
WESTENDHOF 3
45143 ESSEN
GERMANY
JOHNSON CONTROLS
507 E MICHIGAN ST
MILWAUKEE WI 53202
USA
JOHNSON CONTROLS
C/O CONTROLS PRODUCT MANAGEMENT
NO. 22 BLOCK D NEW DISTRICT
WUXI JIANGSU PROVINCE 214142
CHINA
Technical Specifications
The performance specifications are nominal and conform to acceptable industry standard. For application at conditions beyond these
specifications, consult the local Johnson Controls office. Johnson Controls shall not be liable for damages resulting from misapplication or misuse
of its products.
UPSPNL550-0 Panel
Dimensions (H x W x D) 14 x 16 x 6 in. (355.6 x 406.4 x 152.4 mm) vented
Backup time 2 minutes at full load 550 VA/330 W, 8 minutes at half load
Input 96 VAC – 140 VAC 10 A
UPS Output 550 VA/330 W
Frequency 50/60 Hz
Environmental RoHS compliant
Temperature rating 32°F – 104°F (0°C – 40°C)
Temperature See the CyberPower User’s Manual, which is included with the enclosure
Humidity See the CyberPower User’s Manual, which is included with the enclosure
Operating Rh% 0% – 90% non-condensing
Enclosure NEMA type 1
Breaker 10 A
Wire Connections Terminal block
Mounting considerations Wall mounted or other substantial, non-movable structure
Compliance United States cULus Listed; UL File E61466 CCN:NITW, Under UL 508A, Industrial Control Panels
FCC compliant to CFR47, Part 15, Subpart B, Class B
Canada cULus Listed; UL File E61466 CCN:NITW7, Under CAN/CSA C22.2 No. 14-05,
Industrial Control Panels
Industry Canada Compliant to ICES-003, Class B
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5

Johnson Controls UPSPNL550-0 Installation guide

Category
Uninterruptible power supplies (UPSs)
Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI