Samsung FH140GZXC Operating instructions

Category
Vacuum cleaners
Type
Operating instructions

This manual is also suitable for

USERS MANUAL
FH105EZAC/FH105GZXC
FH140EZAC/FH140GZXC
FH175EZAC/FH175GZXC
System Air Conditioner
(Cooling and Heating)
FH105EZAC_E_IB.indd 15 2007-02-14 ソタタ・10:42:19
E-2
Safety Precautions
The following safety precautions must be taken when using your air conditioner.
WARNING
Risk of electric shock can cause injury or death.
Disconnect all remote electric power supplies before servicing, installing or cleaning.
This must be done by the manufacturer or its service agent or a similar qualified
person in order to avoid a hazard.
DURING OPERATION
Users of this product are cautioned not to attempt repair of this product
at their own discretion. Instead, they are requested to directly contact a
designated service center or the outlet at which the product was
purchased.
Never spill any kind of liquid into the unit. Should this happen, unplug
or main switch off the unit and contact an authorized service center.
Do not insert anything between the air outlet blades because the inner
fan may be damaged and could cause injury. Keep children away from
the unit.
Do not place any obstacles in front of the unit.
Do not spray liquid of any kind into the indoor unit. Should this happen,
switch off the breaker used for your air conditioner and contact your
installation specialist.
Make sure that the unit is correctly ventilated at all times:
Do not place clothing or other materials over it.
If the wireless remote control will not be used for a long time, remove
the batteries. (If applicable)
When using a wireless remote control, the distance should not be more
than 7 meters from the air conditioner. (If applicable)
DISPOSING OF THE UNIT
Before throwing out the device, it is necessary to pull back the battery
cells and get rid of them safely for recycling reasons.
When you need to dispose of the unit, consult your dealer. If pipes are
removed incorrectly, refrigerant may blow out and come into contact
with your skin, causing injury. Releasing refrigerant into the atmosphere
also damages the environments.
Please recycle or dispose of the packaging material for this product in
an environmentally responsible manner.
OTHERS
Never store or ship the air conditioner upside down or sideways to
avoid damage to the compressor.
The appliance is not intended for use by young children or infirm
persons without supervision: Young children should be supervised to
ensure that they do not play with the appliance.
Max current is measured according to IEC standard for safety and
current is measured according to ISO standard for energy efficiency.
Register your product at www.samsung.com/global/register
FH105EZAC_E_IB.indd 2 2007-02-14 ソタタ・10:42:12
E-3
PREPARING YOUR AIR CONDITIONER
View of the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Wireless Remote Controller-Buttons and Display . . . . . . . . . . . . . . . . 5
RECOMMENDATIONS FOR USE
Adjusting the Air Flow Direction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Operating Recommendations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Temperature and Humidity Ranges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Cleaning Your Air Conditioner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Troubles and Causes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Troubles and Causes (Concerning Remote Controller) . . . . . . . . . . 11
Contents
FH105EZAC_E_IB.indd 3 2007-02-14 ソタタ・10:42:12
E-4
View of the Unit
C
<Display Panel>
a
b
c
d
e
f
Notice
The chart based on one model of our product is for reference only, which may be different from the unit
you purchased.
Names and functions
Ceiling & Floor Type
indoor unit
installation part
outdoor unit
air-out
remote controller
a
operation lamp
air-in
b
timer indicator
air flow louver (at air outlet)
c
FAN/DEF indicator (For cooling and heating type, its, DEF,
for cooling only type, its, FAN)
connecting pipe
d
alarm indicator
drain hose
e
temporary button
air inlet (with air filter in it)
f
infrared signal receiver
FH105EZAC_E_IB.indd 4 2007-02-14 ソタタ・10:42:13
E-5
1
Mode setting
5
ON/OFF
7
Horiz swing
9
Time setting
6
Air direction setting
8
Vert. swing
11
Time OFF
10
Time ON
Adjust
2
Fan speed setting
4
Adjust
1
3
RESET
Cool/heat
Lock
Reset
15
13
12
14
Confirm button
16
Economic operation
TIME ON
TIME O
FF
CLO
CK
SWI
NG
AIR DIRECTION
OK
EC
O
SWI
NG
MO
DE
FA
N
SPE
ED
AUTO
COO
L
DRY
HEAT
FAN
TEMP
SET
CLOCK
SET
HOUR
FAN SPEED
LOCK
C/H
Wireless Remote Controller-Buttons and Display
Buttons and their functions
FH105EZAC_E_IB.indd 5 2007-02-14 ソタタ・10:42:15
E-6
Adjusting the Air Flow Direction
The following is how to adjust air flow direction when air outlet part
(separately saled) is used with the indoor unit.
Cooling
To effectively cool the whole room, please set the louver so that
the air can come out horizontally.
Heating
To effectively heat the bottom of the room, please set the louver
so that the air can come out downwards.
FH105EZAC_E_IB.indd 6 2007-02-14 ソタタ・10:42:17
E-7
Operating Recommendations
Here are a few recommendations that you should follow when operating your air
conditioner.
Topic Recommendation
Heating
performances
The heat pump function of the air conditioner absorbs
heat from outside air and brings it indoors. As the
temperature of the outside air drops, the heating
performance of air conditioner will decrease. If you find
that the room is not warm enough, using an additional
heating appliance is recommended.
Frost When outside temperature is low but humidity is high,
frost may form on the outdoor unit at HEAT mode.
If this happens:
The heating operation stops.

The defrost mode will be triggered automatically for
about 10 minutes.
No intervention is required ; after about 10 minutes,
the air conditioner operates again normally.
High indoor and
outdoor temperatures
If both indoor and outdoor temperatures are high
and the air conditioner is running at HEAT mode,
the outdoor unit’s fan and compressor may stop at
times.
This is normal ; simply wait until the air conditioner
switches on again.
Power failure Power failure during operation will stop the unit
completely.
The OPERATION lamp on the indoor unit will start
flashing when power is restored.
To restart operation, push the ON/OFF button on the
remote controller.
Lightning or a car wireless telephone operating nearby
may cause the unit to malfunction.
Disconnect the unit with the power and then connect the
unit with the power again. Push the ON/OFF button on the
remote controller to restart operation.
FH105EZAC_E_IB.indd 7 2007-02-14 ソタタ・10:42:17
E-8
Temperature and Humidity Ranges
The following table indicates the temperature and humidity ranges, within which
the air conditioner can be used.
If the air conditioner is used at...
Then...
High temperature
The automatic protection feature may be
triggered and the air conditioner stopped.
Low temperature A water leakage or some other malfunction
may happen if the heat exchanger freezes.
High humidity levels Water may condense on and drip from the
surface of the indoor unit if it is used for a long
period.
Mode Outdoor Temperature Indoor Temperature Indoor Humidity
Heating -7°C to 24°C approx. 0°C to 30°C approx. -
Cooling
17°C to 43°C approx. 17°C to 32°C approx. 80% or less
Drying 11°C to 43°C approx. 17°C to 30°C approx.
-
The standardized temperature for heating is 7°C.
If the outdoor temperature drops to 0°C or below, the heating capacity can be
reduced depending on the temperature condition.
If the cooling operation is used at over 32°C(indoor temperature), it does not
cool at its full capacity.
FH105EZAC_E_IB.indd 8 2007-02-14 ソタタ・10:42:17
E-9
Cleaning Your Air Conditioner
To get the best possible use out of your air conditioner, you must clean it
regularly to remove the dust that accumulates on the air filter.
CAUTION Before cleaning your air conditioner, ensure that you have
switched off the electric circuit breaker used for the unit.
1
Open the air-in grill.
Push the grill switches towards the middle simultaneously as indicated in
follow figure sketch. Then pull down the air-in grill.
CAUTION
The control box cables ,which are originally connected with the
main body electrical terminators must be pulled off before
doing as indicated above.
2
Take out the air-in grill.
3
Dismantle the air filter.
4
Clean the air filter (Vacuum cleaner or pure water may be used to clean the
air filter. If the dust accumulation is too heavy , please use soft brush and mild
detergent to clean it and dry out in cool place) .
The air-in side should face up when using vacuum cleaner. (See Fig. 1)
The air-in side should face down when using water. (See Fig. 2)
CAUTION
Do not dry out the air filter under direct sunshine or with fire.
5
Re-install the air filter.
6
Install and close the air-in grill in the reverse order of step 1 and 2 and connect
the control box cables to the corresponding terminators of the main body .
Note
High-static Pressure Parvis Split Type has no air filter.
Fig. 1
Fig. 2
FH105EZAC_E_IB.indd 9 2007-02-14 ソタタ・10:42:18
E-10
Troubles and Causes
Before you ask for servicing or repairs, check the following points.
Recheck Inoperative.
The power fuse is blown or the circuit breaker has been tripped.
The batteries in the remote controller are exhausted.
The timer is set.
Does not cool or heat well.
The air inlet or outlet of the outdoor unit is blocked.
Doors or windows are open.
The air filter is clogged with dust.
The louver is not at the correct position.
The fan speed is set to low.
The temperature setting is too high or too low.
These are not failures Room air is smelly.
A bad odor comes from the air conditioner.
- Smells impregnated in the wall, carpet, furniture, clothing, or furs,
are coming out. A white mist of chilled air or water is generated from the
outdoor unit.
CAUTION
If any of the following conditions occur, stop the air conditioner immediately, set to off the
power switch, and contact the dealer:
The indicator lamps flash rapidly (five times per second), you disconnect the unit with
the power and then connect the unit with the power again after two or three minutes but
the lamps still flash.
Switch operations are erratic.
The fuse is blown frequently or the circuit breaker is tripped frequently.
Foreign matter or water has fallen inside the air conditioner.
Any other unusual condition is observed.
FH105EZAC_E_IB.indd 10 2007-02-14 ソタタ・10:42:18
E-11
Troubles and Causes
(Concerning Remote Controller)
Before you ask for servicing or repairs, check the following points.
Problem Symptoms Causes Reason and Disposal
Setting Change is
Impossible
The fan speed can not be
changed.
Check whether the MODE
indicated on the display is
AUTO”
When the automatic mode is
selected, the air conditioner
automatically selects the fan speed.
Check whether the MODE
indicated on the display is
“DRY”
When dry operation is selected,
the air conditioner automatically
select the fan speed. The fan speed
can be selected during “COOL and
“FAN ONLY”, and “HEAT.
The Transmission
Indicator
“ Never
Comes On
The remote control
signal is not transmitted
even when the ON/OFF
button is pushed.
Check whether the
batteries in the remote
controller are exhausted.
Check whether the batteries in the
remote controller are exhausted.
Problem Symptoms Causes Reason
The Display Never
Comes On
The TEMP. indicator does
not come on.
Check whether the MODE
indicated on the display is
“FAN ONLY”.
The temperature cannot be
set during fan only operation.
The Display Goes Off The indication on the
display disappears after a
lapse of time.
Check whether the timer
operation has come to an
end when the OFF TIMER
is indicated on the display.
The air conditioner operation
stops since the set time elapsed.
The ON TIMER indicators
go off after a lapse of
certain time.
Check whether the timer
operation is started when
the ON TIMER is indicated
on the display.
When the time set to start the
air conditioner is reached, the
air conditioner will automatically
start and the appropriate indicator
will go off.
Problem Symptoms Causes Disposal
The Signal Receiving
Tone does Not
Sound
No receiving tone sounds
from the indoor unit
even when the ON/OFF
button is pushed.
Check whether the signal
transmitter of the remote
controller is properly
directed to the receiver of
the indoor unit when the
ON/OFF button is pushed.
Direct the signal transmitter of
the remote controller to the
receiver of the indoor unit, and
then repeatly push the ON/OFF
button twice.
Buttons on the remote
controller don’t work.
Press Reset button.
FH105EZAC_E_IB.indd 11 2007-02-14 ソタタ・10:42:18
E-12
MEMO
FH105EZAC_E_IB.indd 12 2007-02-14 ソタタ・10:42:18
E-13
MEMO
FH105EZAC_E_IB.indd 13 2007-02-14 ソタタ・10:42:19
Samsung Electronics Co., Ltd. All Rights Reserved.
C
Contact SAMSUNG WORLD WIDE
If you have any comments or questions regarding a Samsung product, contact the SAMSUNG customer care center.
Country Customer Care Center Web Site
RUSSIA 8-800-200-0400 www.samsung.ru
KAZAHSTAN
8-800-080-1188 www.samsung.kz
UZBEKISTAN
8-800-120-0400 www.samsung.uz
UKRAINE
8-800-502-0000 www.samsung.com/ur
LITHUANIA
8-800-77777 www.samsung.lt
LATVIA
800-7267 www.samsung.com/lv
ESTONIA
800-7267 www.samsung.ee
FH105EZAC_E_IB.indd 14 2007-02-14 ソタタ・10:42:19
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14

Samsung FH140GZXC Operating instructions

Category
Vacuum cleaners
Type
Operating instructions