Alpic Air CS285U-12F5 User manual

Category
Mobile air conditioners
Type
User manual
Before using your air conditioner, please read
this manual carefully and keep it for future reference.
ROOM AIR CONDITIONER
Before using your air conditioner, please read
this manual carefully and keep it for future reference.
ROOM AIR CONDITIONER
Before using your air conditioner, please read
this manual carefully and keep it for future reference.
ROOM AIR CONDITIONER
Before using your air conditioner, please read
this manual carefully and keep it for future reference.
ROOM AIR CONDITIONER
Before using your air conditioner, please read
this manual carefully and keep it for future reference.
ROOM AIR CONDITIONER
Before using your air conditioner, please read
this manual carefully and keep it for future reference.
ROOM AIR CONDITIONER
Before using your air conditioner, please read
this manual carefully and keep it for future reference.
ROOM AIR CONDITIONER
Before using your air conditioner, please read
this manual carefully and keep it for future reference.
ROOM AIR CONDITIONER
Before using your air conditioner, please read
this manual carefully and keep it for future reference.
ROOM AIR CONDITIONER
Before using your air conditioner, please read
this manual carefully and keep it for future reference.
ROOM AIR CONDITIONER
Before using your air conditioner, please read
this manual carefully and keep it for future reference.
ROOM AIR CONDITIONER
Before using your air conditioner, please read
this manual carefully and keep it for future reference.
ROOM AIR CONDITIONER
Read This Manual
Keep this manual where the operator can easily
find them. Inside you will find many helpful hints
on how to use and maintain your air conditioner
properly. Just a little preventative care on your
part can save you a great deal of time and money
over the life of your air conditioner. You'll find many
answers to common problems in the chart of
troubleshooting tips. If you review the chart of
Troubleshooting Tips first, you may not need
to call for service.
The design and specifications are subject to change without prior notice for
product improvement. Consult with the sales agency or manufacturer for details.
SPLIT-TYPE
CS285U-12F5
16122000A03952
20160715
11
22
CONTENTS
DISPOSAL: Do not dispose of this product as unsorted municipal waste. Collection of such waste
separately for special treatment is necessary.
It is prohibited to dispose of this appliance in domestic household waste. For disposal, there are
several possibilities:
A) The municipality has established collection systems, where electronic waste can
be disposed of at least free of charge to the user.
B) When buying a new product, the retailer will take back the old product at least
free of charge.
C) The manufacturer will take back the old appliance for disposal at least free of
charge to the user.
D) As old products contain valuable resources, they can be sold to scrap metal
dealers.
Wild disposal of waste in forests and landscapes endangers your health when hazardous
substances leak into the ground-water and find their way into the food chain.
When using this air conditioner in the European countries, please read the
following information:
SAFETY PRECAUTIONS
NAMES OF PARTS
OPERATING INSTRUCTIONS
CARE AND MAINTENANCE
TROUBLESHOOTING TIPS
Warning .....................................................................................................................................3
Caution ......................................................................................................................................4
.
Indoor unit ........... .....................................................................................................................5
outdoor unit ...............................................................................................................................5
Indication lamp...........................................................................................................................5
Special functions .......................................................................................................................6
Operating temperature................................................................................................................7
Manual operation ......................................................................................................................7
Airflow direction control ............................................................................................................8
How the air conditioner works ..................................................................................................9
Before maintenance...... ...........................................................................................................10
Cleaning the unit.......................................................................................................................10
Cleaning the air filter and air freshening filter ..........................................................................10
Replacement of the air filter and air freshening filter ...............................................................11
Preparation for extended non-operation....................................................................................11
Pre-season inspection...............................................................................................................11
Normal function of the air conditioner.......................................................................................12
Troubleshooting guide .............................................................................................................14
This appliance can be used by children aged from 8 years and above and persons with
reduced physical, sensory or mental capabilities, or lack of experience and knowledge if they
have been given supervision or instruction concerning use of the appliance in a safe way and
understand the hazards involved. Children shall not play with the appliance. Cleaning and user
maintenance shall not be made by children without supervision.
SAFETY PRECAUTIONS
SAFETY PRECAUTIONS
To prevent injury to the user or other people and property damage, the following instructions
must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage.
The seriousness is classified by the following indications.
This symbol indicates the possibility of death or serious injury.
Meanings of symbols used in this manual are as shown below.
WARNING
Be sure to follow the instructions.
Strictly prohibited.
CAUTION
This symbol indicates the possibility of injury or damage to property.
Do not extend the cable and never use
multiple plugs. A poor electrical connection,
poor insulation or voltage which is higher
than permitted can cause fire.
Do not expose your body directly to the cool
air for prolonged period.
Never poke fingers, sticks or other objects
in the air inlet and outlet vents.
Never attempt to repair, relocate, modify the
air conditioner yourself. Always contact your
service provider if required.
Never pull the plug out by pulling on the
cable. Hold the plug firmly and pull it out of
the plug socket, otherwise there is a risk of
damaging the cable.
Do not operate your air conditioner in a wet
room such as a bathroom or laundry room.
Never actuate any switches with a wet
hand. It may cause an electric shock.
Never use the device for any other
purpose than the intended use. Never
place food, precision instruments, plants,
animals, paint, etc. on the unit.
Do not expose plants or animals directly
to the air flow.
Never clean the air conditioner with water.
Never use combustible cleaning agents
as these could cause a fire or deformation.
Never place any burning objects close to
the device if they could be directly affected
by the emitted air.
Never step onto the outdoor unit and
never place anything on it.
Never use an unsteady or rusty base.
Never install the air conditioner in places
where combustible gas can be emitted.
Emmitted gas may collect and cause an
explosion.
Never allow the air conditioner to run for
too long with the doors or windows open,
or if the humidity is very high.
Remove all dirt from the power plug and
plug it firmly. Soiled plugs can cause fire
or an electric shock.
In the event of any abnormalities such
as smell of burning, immediately switch
off the device and pull the plug. Contact
your service provider.
Always switch off the device and pull the
plug before you start to clean it.
Use specified power cord.
Contact the authorized installer for
installation of this unit.
Contact an authorized service technician
for repair or maintenance of this unit.
This appliance is not intended for use by
persons(including children) with reduced
physical, sensory or mental capabilities, or
lack of experience and knowledge, unless
they have been given supervision or
instruction concerning use of the appliance
by a person responsible for their safety.
Children should be supervised to ensure
that they do not play with the air
conditioner.
If the air conditioner is to be used in
conjunction with other heaters, the air
should be refreshed periodically, otherwise
there is a risk of lack of oxygen.
Always pull out the power plug if the unit
is not going to be used for any lengthy
period of time. Collections of dust can
cause fire.
Always switch off the air conditioner and
pull out the power plug during a storm,
otherwise, electrical parts may get
damaged.
Check that the drainage line is correctly
connected. If not, water will escape.
Check that the condensation water can
run off unhindered. It may cause water
damage if the condensation water cannot
run off properly.
The air conditoner must be earthed in
accordance with the local codes.
For electrical safety purposes we
recommend that you install an earth-
leakage circuit-breaker.
If the power cord is damaged, it must be
replaced by the manufacturer, its service
agent or similary qualified persons in order
to avoid a hazard.
WARNING
CAUTION
33
44
OPERATING INSTRUCTIONS
8. Connecting pipe
9. Connecting cable
10. Stop valve
Outdoor unit
Air inlet(rear)
Air inlet(side)
Air outlet
1. Front panel
2. Air inlet
3. Air filter
4. Air outlet
5. Horizontal air flow grille
6. Vertical air flow louver(inside)
7. Display panel
Indoor unit
RUN indication lamp
This lamp illuminates when the air
conditioner is in operation.
TIMER indication lamp
Lights up during Timer operation.
DEFROST indication lamp
(Enabled on cooling & heating models only):
Lights up when the air conditioner starts
defrosting automatically or when the warm
air control feature is activated in heating
operation.
4
3
5
2
6
1
9
10
7
TEMPERATURE indication lamp
Displays the temperature settings when the
air conditioner is operational.
Displays the malfunction code when fault
occurs .
FRESH indication lamp(optional)
Lights up when Clean Air feature is
activated.
NAMES OF PARTS
Indication lamp
Indication lamp
NOTE:
All the pictures in this manual are for
explanation purposes only. The actual shape
of the indoor unit you purchased may be slightly
different on front panel and display window. The
actual shape shall prevail.
Names of parts
(A)
(B)
FRESH DEFROST RUN TIMER
FRESH DEFROST RUN TIMER
Model B
Model A
Special functions
Improving the quality of indoor air is one
of the purposes of an air conditioner.
This air conditioner is equipped with
ionizer or Plasma Dust Collector(model
dependent). With the anions generated
by Ionizer, the air circulation of the air
conditioner fills the room with refreshing,
natural and healthy air. The Plasma Dust
Collector generates a high voltage
ionization zone, through which the air is
converted to plasma. Inside the air most
of the dust, smoke, and pollen particles
are captured by the electrostatic filter.
CLEAN AIR function(Optional)
Airborne bacteria use the moisture on the
indoor heat exchanger to grow. Regular
drying of the exchanger prevents this
growth. By simply pressing the SELF
CLEAN button, the system will automatically
manage the process. This cleaning action
may be done as frequently as desired.
For cooling models, only the indoor fan is
active in low speed for 30 minutes and the
unit turns off automatically.
For cooling & heating models, the unit will
operate as in the following sequence :
FAN mode at Low fan speed--Heating
operation with LOW fan speed ---FAN
operation--Stop Operation---Turn off.
Note:
This function is only activated in COOLING
or DRY mode.
Before activation the air conditioner, it is
recommended to run the air conditioner
under cooling operation for about 30
minutes.
Pressing the SELF CLEAN or ON/OFF
button again during the cleaning cycle will
cancel the operation and turn the unit off.
SELF CLEAN function(Optional)
Refrigerant Leakage Detection (Optional)
When refrigerant leakage is detected,
the indoor unit will display EC code or
flash LEDs(model dependent).
,
,
Louver Angle Memory Function
(optional):
Within the scope of safety angle, the
horizontal louver angle is memorised
and will return to the position last
selected by user. If it exceeds, it will
memorize the boundary of safety angle.
This will not happen when Turbo or
manual control buttons are pressed or
after a power interruption. So we
strongly suggest that the open angle of
the horizontal louver should not be set
too small, in case the condensed water
forms and drips from the horizontal louver.
After 240 hours of operation, the indoor
display window will display and flash CL ,
this feature is a reminder to clean the Air
Filter for more efficient operation. After 15
seconds, the system will revert back to the
previous display again. When the CL
indicator appears and flashes, please
press the LED button on remote controller
for 4 times or press the Manual control
button for 3 or more times to clear the
registered hours, otherwise the CL
indicator will display and flash again for
another 15 seconds at the next time of
tarting the unit.
Cleaning filter reminding function
(Optional)
,
,
,
,
,
,
After 2880 hours of operation, the indoor
display window will display and flash nF ,
this feature is a reminder to replace the Air
Filter for more efficient operation. After 15
seconds, the system will revert back to the
previous display again. When the nF
indicator appears and flashes, please
press the LED button on remote controller
for 4 times or press the Manual control
button for 3 or more times to clear the
registered hours, otherwise the nF
indicator will display and flash again for
another 15 seconds at the next time of
starting the unit.
Replacing filter reminding function
(Optional)
,
,
,
,
,
,
8
The display panel of the indoor unit
may look like one of the following:
55
66
OPERATING INSTRUCTIONS
Airflow direction control
Adjust the air flow direction properly, otherwise it might
cause discomfort or cause uneven room temperatures.
Adjust the horizontal louver using the remote controller.
Adjust the vertical louver manually or using the remote
controller(depending on models).
To set the vertical air flow(Up--Down) direction
Perform this function while the unit is in operation.
Use the remote controller to adjust the air flow
direction. The horizontal louver can be moved at
O
a range of 6 for each press, or swing up and down
automatically. Please refer to the REMOTE
CONTROLLER OPERATION MANUAL for details.
To set the horizontal air flow direction (left - right)
Move the deflector rod manually to adjust the air flow
in the direction you prefer.
IMPORTANT:Do not put your fingers into the panel of
blower and suction side.The high-speed fan inside may
cause danger.
For some models, the vertical louver can be adjusted
by using the remote controller. Please refer to the
REMOTE CONTROLLER OPERATION MANUAL
for details.
,,
,,
,,
,,
OPERATING INSTRUCTIONS
NOTE: This manual does not include Remote Controller Operations, see the
<<Remote Controller Instruction>> packed with the unit for details.
Operating temperature
Mode
Cooling operation
Heating operation
Drying operation
Temperature
1. Optimum performance will be achieved within these operating temperatures. If air
conditioner is used outside of the above conditions, certain safety protection features
might come into operation and cause the unit to function abnormally.
2. Room relative humidity less than 80%. If the air conditioner operates in excess of this
figure, the surface of the air conditioner may attract condensation. Please sets the vertical
air flow louver to its maximum angle (vertically to the floor), and set HIGH fan mode.
Room temperature
Outdoor temperature
NOTE:
( For the models with low
temperature cooling system
(For special tropical models)
(For special tropical models)
Range
Range
Deflector rod
AUTO/COOL
Suspension bars
AUTO/COOL
(1)
(2)
Units are equipped with a switch to run emergency operation mode. It can be accessed by
opening the front panel. This switch is used for manual operation in case the remote controller
fails to work or maintenance necessary.
Manual operation
Hold the panel sides and lift the front panel
up to an angle until it remains fixed with a
clicking sound. For some models, please
use suspension bars to prop up the panel.
Once you push the manual switch, the
operation mode is shifted in an order as:
AUTO, COOL, OFF. The temperature will
OO
be set at 24 C/76 F and the fan on Auto.
After operation, close the panel firmly to its
original position.
1
3
2
Manual switch
Manual switch
This switch is used for testing purposes
only. You had better not choose it.
To restore the remote controller operation,
use the remote controller directly.
CAUTION:
Do not operate the air conditioner for long periods with
the air flow direction set downward in cooling or
dehumidifying mode. Otherwise, condensation may
occur on the surface of the horizontal louver causing
moisture to drop on to the floor or on furnishings.
When the air conditioner is started immediately after it
was stopped, the horizontal louver might not move for
approximately 10 seconds.
Open angle of the horizontal louver should not be set
too small, as COOLING or HEATING performance may
be impaired due to too restricted air flow area.
Do not move the horizontal louver manually, otherwise
the horizontal louver will be out of sync. Please cease
operating, unplug power for a few seconds,then restart
the air conditioner.
CAUTION
NOTE:
Best working conditions(the energy efficiency can be
affected if not set under these conditions):
The best angle of louvers is the default angle of cooling
mode
The best way of setting the angle of louvers at heating
mode is: run the unit for 5 minutes and then use the
remote controller to set the louvers at the default angle
of cooling mode.
77
88
OO
17 C~32 C
(62 )
OO
F~90 F
OO
18 C~43 C
(64 )
OO
F~109 F
OO
18 C~54 C(64 )
OO
F~129 F
OO
18 C~54 C(64 )
OO
F~129 F
OO
11 C~43 C
(52 )
OO
F~109 F
OO
-7 C~24 C
(20 )
OO
F~76 F
OO
-7 C~43 C(20 )
OO
F~109 F
OO
0 C~30 C
(32 )
OO
F~86 F
OO
10 C~32 C
OO
(50 F~90 F)
CARE AND MAINTENANCE
Care and Maintenance
Filter Handle
OPERATING INSTRUCTIONS
How the air conditioner works
1 hour
1 hour
Set
Temperature
Set
Temperature
Cooling
Heating
SLEEP operation
1 hour
1 hour
SLEEP operation
7 hours timer off
7 hours timer off
AUTO operation
When you set the air conditioner in AUTO mode, it will
automatically select cooling, heating(cooling/heating
models only), or fan only operation depending on set
temperature and the room temperature.
The air conditioner will control room temperature
automatically to the temperature point you set.
If you feel uncomfortable in the AUTO mode, you can set
your desired temperature.
SLEEP operation
When you push SLEEP button on remote controller
during cooling, heating(cooling & heating models only),
or AUTO operation , the air conditioner will
automatically increase (cooling) or decrease (heating)
OO
1 C/2 F per hour for the first 2 hours, then hold
steadily for the next 5 hours, after that it will switch off.
This mode saves you energy and brings you comfort
at night.
DRYING operation
The temperature is regulated while dehumidifying by
repeating turning on and off of the cooling operation or
fan only. The fan speed is LOW.
Optimal operation
To achieve optimal performance, please note the
following:
Adjust the air flow direction correctly so that it is not
towards people.
Adjust the temperature to achieve the highest comfort
level. Do not adjust the unit to excessive temperature
levels.
Close doors and windows on COOL or HEAT modes,
or performance may be reduced.
Use TIMER ON button on the remote controller to
select a time you want to start your air conditioner.
Do not put any object near air inlet or air outlet, as the
efficiency of the air conditioner may be reduced and
the air conditioner may stop running.
Clean the air filter periodically, otherwise cooling or
heating performance may be reduced.
Do not operate unit with horizontal louvre in closed
position.
Before mainatenance
A cloth dampened with cold water may be used
on the indoor unit if it is very dirty, after that, the
unit should be dried with a dry cloth.
Do not use a chemically treated cloth or duster to
clean the unit.
Do not use benzine, thinner, polishing powder, or
similar solvents for cleaning. These may cause
the plastic surface to crack or deform.
Never use water hotter than 40 C/104 F to clean
the front panel, it could cause deformation of
discolouration.
CAUTIONS
Turn the system off before cleaning. To clean, wipe with
a soft, dry cloth. Do not use bleach or abrasives.
NOTE: Power supply must be disconnectd before
cleaning the indoor unit.
Cleaning the air filter and air freshening filter
A clogged air filter reduces the cooling efficiency of
this unit. Please clean the filter once every 2 weeks.
1. Lift the indoor unit panel up to an angle until it
stops with a clicking sound.For some models,
please use suspension bars to prop up the panel.
2. Take hold of the handle of the air filter and lift it
up slightly to take it out from the filter holder,
then pull it downwards.
3. Remove the AIR FILTER from the indoor unit.
Clean the AIR FILTER once two weeks.
Clean the AIR FILTER with a vacuum cleaner
or water, then dry it up in cool place.
4. Remove the Air Freshening Filter from its supporting
frame (on some models).
Clean the air freshening filter at least once a
month, and replace it every 4-5 months.
Clean it with vacuum cleaner, then dry it in cool
place.
Air freshen
ing filter
99
1010
CARE AND MAINTENANCE
The following events may occur during normal operation.
1. Protection of the air conditioner.
Compressor protection
The compressor can't restart for 3-4 minutes after it stops.
Anti-cold air (Cooling and heating models only)
The unit is designed not to blow cold air on HEAT mode, when the indoor heat exchanger is in
one of the following three situations and the set temperature has not been reached.
A) When heating has just started.
B) Defrosting.
C) Low temperature heating.
The indoor or outdoor fan stop running when defrosting (Cooling and heating models only).
Defrosting (Cooling and heating models only)
Frost may be generated on the outdoor unit during heat cycle when outdoor temperature is low
and humidity is high resulting in lower heating efficiency of the air conditioner.
During this condition air conditioner will stop heating operation and start defrosting automatically.
The time to defrost may vary from 4 to 10 minutes according to the outdoor temperature and
the amount of frost built up on the outdoor unit.
2. A white mist coming out from the indoor unit
A white mist may generate due to a large temperature difference between air inlet and air outlet
on COOL mode in an indoor environment that has a high relative humidity.
A white mist may generate due to moisture generated from defrosting process when the air
conditioner restarts in HEAT mode operation after defrosting.
3. Low noise of the air conditioner
You may hear a low hissing sound when the compressor is running or has just stopped running.
It is the sound of the refrigerant flowing or coming to a stop.
You can also hear a low "squeak" sound when the compressor is running or has just stopped
running. This is caused by heat expansion and cold contraction of the plastic parts in the unit
when the temperature is changing.
A noise may be heard due to louver restoring to its original position when power is turned on.
4. Dust is blown out from the indoor unit.
This is a normal condition when the air conditioner has not been used for a long time or during first
use of the unit.
5. A peculiar smell comes out from the indoor unit.
This is caused by the indoor unit giving off smells permeated from building material, from furniture,
or smoke.
6. The air conditioner turns to FAN only mode from COOL or HEAT mode (For cooling and
heating models only) .
When indoor temperature reaches the temperature setting on air conditioner, the compressor will
stop automatically, and the air conditioner turns to FAN only mode. The compressor will start again
when the indoor temperature rises on COOL mode or falls on HEAT mode (For cooling and heating
models only) to the set point.
Preparation for extended non-operation
Pre-season inspection
If you plan to idle the unit for a long time, perform
the following:
(1) Clean the indoor unit and filters.
(2) Operate the fan for about half a day to dry the
inside of the unit.
(3) Stop the air conditioner and disconnect power.
(4) Remove the batteries from the remote controller.
The outdoor unit requires periodic maintenance
and cleaning. Do not attempt to do this yourself.
Contact your dealer or service provider.
Check that the wiring is not broken off or
disconnected.
Clean the indoor unit and filters.
Check that the air filter is installed.
Check if the air outlet or inlet is blocked after the
air conditioner has not been used for a long time.
Do not touch the metal parts of the unit when
removing the filter. Injuries can occur when
handling sharp metal edges.
Do not use water to clean inside the air conditioner.
Exposure to water can destroy the insulation,
leading to possible electric shock.
When cleaning the unit, first make sure that the
power and circuit breaker are turned off.
Do not wash air filter with hot water at more than
O
40 C . Shake off moisture completely and dry
it in the shade. Do not expose it directly to the sun,
it may shrink.
O
/104 F
Caution
5. Install the air freshening filter back into position.
6. Insert the upper portion of air filter back into the
unit, taking care that the left and right edges line
up correctly and place filter into position.
Replacement of air filter and air freshening filter
1. Remove the air filter.
2. Remove the air freshening filter.
3. Install a new air freshening filter.
4. Reinstall the air filter and securely close the front
panel.
Normal function of the air conditioner
TROUBLESHOOTING TIPS
1111
1212
TROUBLESHOOTING TIPS
Malfunctions
Unit does not
start
Unit not cooling
or heating
(Cooling/ heating
models only)
room very well
while air flowing
out from the air
conditioner
Cause
Power cut
Unit may have become unplugged
Fuse may have blown.
Battery in Remote controller may
have been exhausted.
The time you have set with timer
is incorrect.
Wait for power to be restored.
Check that plug is securely in wall
receptacle.
Replace the fuse.
Replace the battery.
Wait or cancel timer setting.
Set temperature correctly. For
detailed method please refer to
"Using remote control" section.
Clean the air filter.
Close the doors or windows.
Clear obstructions away first, then
restart the unit.
Wait.
Inappropriate temperature
setting.
Air filter is blocked.
Doors or Windows are open.
Air inlet or outlet of indoor or
outdoor unit has been blocked.
Compressor 3 or 4 minutes
protection has been activated.
If the trouble has not been corrected, please contact a local dealer or the nearest customer
service center. Be sure to inform them of the detailed malfunctions and unit model number.
Notes: Do not attempt to repair the unit yourself.
Always consult an authorized service provider.
What should be done?
TROUBLESHOOTING TIPS
Troubleshooting guide
8. Dripping water may generate on the surface of the indoor unit when cooling in a high
relatively humidity (relative humidity higher than 80%). Adjust the horizontal louver to
the maximum air outlet position and select HIGH fan speed.
9. Heating mode (For cooling and heating models only)
The air conditioner draws in heat from the outdoor unit and releases it via the indoor unit
during heating operation. When the outdoor temperature falls, heat drawn in by the air
conditioner decreases accordingly. At the same time, heat loading of the air conditioner
increases due to larger difference between indoor and outdoor temperature. If a
comfortable temperature can't be achieved by the air conditioner, we suggest you use a
supplementary heating device.
10. Auto-restart function
Power failure during operation will stop the unit completely.
For the unit without Auto-restart feature, when the power restores, the OPERATION indicator
on the indoor unit starts flashing. To restart the operation, push the ON/OFF button on the
remote controller. For the unit with Auto-restart feature, when the power restores, the unit
restarts automatically with all the previous settings preserved by the memory function.
7.The air conditioner runs function after turning off the unit.
When turning off the unit under COOL(AUTO COOL, FORCED COOL) and DRY mode, the air
conditioner will run function for 7-10 minutes, then stop the operation and turn
off the unit automatically.
Anti-mildew
Anti-mildew
Fuse blows frequently or circuit breaker trips
frequently .
Other objects or water fall into the air conditioner.
Terrible odors are smelled or abnormal sounds
are heard.
Trouble
OPERATION(RUN) indicator or other
indicators continue flashing.
If one of the following code appears on the
display area : E0,E1,E2,E3.....or P0,P1,P2,
P3...., or F1,F2,F3.......
The unit may stop operation or continue to
run in a safety condition (depending on
models). Waiting for about 10 minutes, the
fault may be recovered automatically, if
not, disconnect the power and then
connect it in again. If the problem still
exists, disconnect the power and contact
the nearest customer service center.
Stop the air conditioner immediately,
disconnect the power and contact the
nearest customer service center.
Displays the special functions in the following ways(for some models only):
Displays for three seconds when Timer ON, Fresh, Swing, Turbo
or Silence feature is activated.
Displays for three seconds when Timer OFF is set.
Displays for three seconds when Fresh, Swing, Turbo or Silence
feature is cancelled.
Displays under defrosting operation.
Displays when anti-cold air feature is
activated under heating mode.
Displays during self clean operation(if applicable).
O
Displays under 8 C heating operation(if applicable).
,
,
,
,
,
,
,
,
,
,
,
,
,
,
11. Special function display
1313
1414
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Alpic Air CS285U-12F5 User manual

Category
Mobile air conditioners
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI