Kichler Lighting 45033DAG User manual

Type
User manual

This manual is also suitable for

IMPORTANT SAFETY INSTRUCTIONS
LIGHTED BULB IS HOT!
WARNING: To reduce the risk of FIRE or INJURY TO PERSON:
• Turnoffandallowtocoolbeforereplacingbulb.
• BulbgetsHOTQUICKLY!Contactswitchonlywhenturningoff.
• DONOTremaininlightifskinfeelswarm.(Lightisintense,
maycause“sunburn”)
• DONOTlookdirectlyatlightedbulb.
• Keepmaterialsawayfrombulbthatmayburn.
• UseONLYwithwattagespeciedorlower.
• DONOTtouchbulbatanytime,useasoftcloth.Oilfromskin
maydamagebulb.
• DONOToperatexturewithmissingordamagedglass.
1) TURN OFF POWER.
IMPORTANT:Beforeyoustart,NEVERattemptanywork
withoutshuttingofftheelectricityuntiltheworkisdone.
a) Gotothemainfuse,orcircuitbreaker,boxinyour
home.Placethemainpowerswitchinthe“OFF”
position.
b) Unscrewthefuse(s),orswitch“OFF”thecircuitbreaker
switch(s),thatcontrolthepowertothextureorroom
thatyouareworkingon.
c) Placethewallswitchinthe“OFF”position.Ifthexture
tobereplacedhasaswitchorpullchain,placethosein
the“OFF”position.
2) Findtheappropriatethreadedholesonmountingstrap.
Assemblemountingscrewsintothreadedholes.
3) Attachmountingstraptooutletbox.(Screwsnotprovided).
Mountingstrapcanbeadjustedtosuitpositionofxture.
4) Groundinginstructions:(SeeIllus.AorB).
A) Onxtureswheremountingstrapisprovidedwithahole
andtworaisedimples.Wrapgroundwirefromoutlet
boxaroundgreengroundscrew,andthreadintohole.
B) Onxtureswhereacuppedwasherisprovided.Attach
groundwirefromoutletboxundercuppedwasherand
greengroundscrew,andthreadintomountingstrap.
Ifxtureisprovidedwithgroundwire.Connectxture 
groundwiretooutletboxgroundwirewithwireconnector.
(Notprovided.)Afterfollowingtheabovesteps.Neverconnect
groundwiretoblackorwhitepowersupplywires.
5) Makewireconnections(connectorsnotprovided.)Reference
chartbelowforcorrectconnectionsandwireaccordingly.
6) Pushxturetowall,carefullypassingmountingscrews
throughholesincanopy.
7) Screwthreadedballsontoendsofmountingscrews.
Tightenthreadedballstosecurexturetowall.
8) Setglassthenspacerdownoversocket.
9) Threadsocketringontosocket.(DONOTovertighten.)
10) Insertrecommendedbulb.CAUTION: DONOTtouchbulb
withbarehands.Ifthishappens,cleanbulbwithdenatured
alcoholandalintfreecloth.
11) Lowerglasssleevedownoverbulb.Carefullythreadglass
sleeveontosocket.(DONOTovertighten.)
DateIssued:1/11/13 IS-45038-US
GREEN GROUND
SCREW
CUPPED
WASHER
A
B
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
(NOT PROVIDED)
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
Connect Black or
Red Supply Wire to:
Connect
White Supply Wire to:
Black White
*Parallel cord (round & smooth) *Parallel cord (square & ridged)
Clear, Brown, Gold or Black
without tracer
Clear, Brown, Gold or Black
with tracer
Insulated wire (other than green)
with copper conductor
Insulated wire (other than green)
with silver conductor
*Note: When parallel wires (SPT I & SPT II)
are used. The neutral wire is square shaped
or ridged and the other wire will be round in
shape or smooth (see illus.)
Neutral Wire
FIXTURE
ARTEFACTO
GLASS
VIDRIO
SEE OTHER SIDE FOR SPANISH TRANSLATIONS.
VEA EL OTRO LADO DE TRADUCCIONES AL ESPAÑOL.
MOUNTINGSTRAP
PLANCHAPARA
MONTAR
THREADEDBALL
BOLAROSCADO
BULB
BOMBILLA
GLASSSLEEVE
CAMISADEVIDRIO
SOCKETRING
ANILLODELCASQUILLO
We’re here to help 866-558-5706
Hrs: M-F 9am to 5pm EST
SPACER
ESPACIADOR
IMPORTANT SAFETY INSTRUCTIONS
LIGHTED BULB IS HOT!
WARNING: To reduce the risk of FIRE or INJURY TO PERSON:
• Turnoffandallowtocoolbeforereplacingbulb.
• BulbgetsHOTQUICKLY!Contactswitchonlywhenturningoff.
• DONOTremaininlightifskinfeelswarm.(Lightisintense,
maycause“sunburn”)
• DONOTlookdirectlyatlightedbulb.
• Keepmaterialsawayfrombulbthatmayburn.
• UseONLYwithwattagespeciedorlower.
• DONOTtouchbulbatanytime,useasoftcloth.Oilfromskin
maydamagebulb.
• DONOToperatexturewithmissingordamagedglass.
1) TURN OFF POWER.
IMPORTANT:Beforeyoustart,NEVERattemptanywork
withoutshuttingofftheelectricityuntiltheworkisdone.
a) Gotothemainfuse,orcircuitbreaker,boxinyour
home.Placethemainpowerswitchinthe“OFF”
position.
b) Unscrewthefuse(s),orswitch“OFF”thecircuitbreaker
switch(s),thatcontrolthepowertothextureorroom
thatyouareworkingon.
c) Placethewallswitchinthe“OFF”position.Ifthexture
tobereplacedhasaswitchorpullchain,placethosein
the“OFF”position.
2) Findtheappropriatethreadedholesonmounting
strap.Assemblemountingscrewsintothreadedholes.
3) Attachmountingstraptooutletbox.(Screwsnotprovided).
Mountingstrapcanbeadjustedtosuitpositionofxture.
4) Makewireconnections(connectorsnotprovided.)Reference
chartbelowforcorrectconnectionsandwireaccordingly.
5) Pushxturetowall,carefullypassingmountingscrews
throughholesincanopy.
6) Screwthreadedballsontoendsofmountingscrews.
Tightenthreadedballstosecurexturetowall.
7) Setglassthenspaceroversocket.
8) Insertrecommendedbulb.CAUTION: DONOTtouchbulb
withbarehands.Ifthishappens,cleanbulbwithdenatured
alcoholandalintfreecloth.
9) Lowerglasssleevedownoverbulb.Carefullythreadglass
sleeveontosocket.(DONOTovertighten.)
IMPORTANTES CONSIGNES DE SÉCURITÉ
UNE AMPOULE ALLUMÉE EST BRÛLANTE !
AVERTISSEMENT: Pour réduire les risques D’INCENDIE ou DE
BLESSURE:
• Éteindreetlaisserrefroidiravantderemplacerl’ampoule.
• LesampouleschauffentTRÈSRAPIDEMENT!N’éteindrequ’à
l’aidedel’interrupteur.
• NEPASresterdanslalumièresiunesensationdechaleurest
ressentiesurlapeau.(Lalumièreestintenseetpeutprovoquer
descoupsdesoleil).
• NEJAMAISregarderdirectementuneampouleallumée.
• Tenirlesmatériauxàl’écartd’uneampoulepouréviterqu’ils
nebrûlent.
• UtiliserUNIQUEMENTdesampoulesàlapuissancenominale
indiquée(watts)ouàunepuissanceinférieure.
• NEJAMAIStoucherl’ampouleàmainnue,seservird’untissu
doux.L’huiledelapeaupeutendommagerl’ampoule.
1) COUPERLECOURANT.
IMPORTANT:TOUJOURScouperl’électricitéavantde
commencerletravail.
a) Localiserlecoffretàfusiblesouledisjoncteurdu
domicile.Mettrel’interrupteurprincipalenposition
d’Arrêt.
b) Dévisserleoulesfusibles(oumettreledisjoncteursur
Arrêt)quicontrôlentl’alimentationversleluminaireoula
piècedanslaquelleletravailesteffectué.
Connect Black or
Red Supply Wire to:
Connect
White Supply Wire to:
Black White
*Parallel cord (round & smooth) *Parallel cord (square & ridged)
Clear, Brown, Gold or Black
without tracer
Clear, Brown, Gold or Black
with tracer
Insulated wire (other than green)
with copper conductor
Insulated wire (other than green)
with silver conductor
*Note: When parallel wires (SPT I & SPT II)
are used. The neutral wire is square shaped
or ridged and the other wire will be round in
shape or smooth (see illus.)
Neutral Wire
DateIssued:1/11/13 IS-45038-CB
INSTRUCTIONS
For Assembling and Installing Fixtures in Canada
Pour L’assemblage et L’installation Au Canada
THREADEDBALL
BOULEFILETE
c) Mettrel’interrupteurmuralenpositiond’Arrêt.Sileluminaire
àremplacerestdotéd’uninterrupteuroud’unechaîne
connectéeàl‘interrupteur,placercesélémentsen
positiond’Arrêt.
2) Trouverlestrousletésappropriéssurlabarrettedemontage.
Vissezlesvisdemontagedanslestrousletés.
3) Visserlabarrettedemontageàlaboitedejonction.(Vis
nonfournies).Labarrettedemontagepeutetreajustéepour
conveniràlapositiondel’applique.
4) Connecterlesls(connecteursnonfournis).Sereporterau
tableauci-dessouspourfairelesconnexions.
5) Plaquezleluminairecontrelemur,enpassantsoigneusement
lesvisdemontagedanslestrousdanslecache.
6) Visserlesboulesletéesdanslesextrémitésdesvisdemontage.
Serrerlesboulesletéespourxerleluminaireaumur.
7) Placerleverrepuisl’entretoisesurladouille.
8) Introduirel’ampoulerecommandée.ATTENTION:NEPAS
toucherl’ampouleàmainnue.Silapeauentreencontact
avecl’ampoule,nettoyerl’ampouleavecdel’alcooldénaturé
etuntissunonpelucheux.
9) Passerlemanchondeverresurlalampe.Visserdélicatement
lemanchondeverredansladouille.(NEPASserreravec
excès).
MOUNTINGSTRAP
COLLLIERDEFIXATION
Connecter le fil noir ou
rouge de la boite
Connecter le fil blanc de la boîte
A Noir A Blanc
*Au cordon parallèle (rond et lisse)
*Au cordon parallele (à angles droits el strié)
Au bransparent, doré, marron, ou
noir sans fil distinctif
Au transparent, doré, marron, ou
noir avec un til distinctif
Fil isolé (sauf fil vert) avec
conducteur en cuivre
Fil isolé (sauf fil vert) avec
conducteur en argent
*Remarque: Avec emploi d’un fil paralléle
(SPT I et SPT II). Le fil neutre est á angles
droits ou strié et l’autre fil doit étre rond ou
lisse (Voir le schéma).
Fil Neutre
GLASS
VERRE
BULB
L’AMPOULE
GLASSSLEEVE
MANCHONDEVERRE
SOCKETRING
ANNEAUDELADOUILLE
SPACER
ENTRETOISE
We’re here to help 866-558-5706
Hrs: M-F 9am to 5pm EST