Emerson 65, a reliable surge protector, offers comprehensive protection for your critical business systems. Its flexible mounting options and universal panelboard compatibility make it easy to integrate with existing electrical setups. With surge current capacities ranging from 65,000 amps to 130,000 amps per phase, it ensures superior protection against power surges and electrical noise. Advanced features like real-time status monitoring, isolated dry contacts, and optional audible alarms and transient counters provide enhanced visibility and control.

Emerson 65, a reliable surge protector, offers comprehensive protection for your critical business systems. Its flexible mounting options and universal panelboard compatibility make it easy to integrate with existing electrical setups. With surge current capacities ranging from 65,000 amps to 130,000 amps per phase, it ensures superior protection against power surges and electrical noise. Advanced features like real-time status monitoring, isolated dry contacts, and optional audible alarms and transient counters provide enhanced visibility and control.

Surge Protection
For Business-Critical Continuity
The Liebert PanelGuard Extension is
an add-on device for integration with
panelboards
a
a
t
t
t
t
h
h
e
e
j
j
o
o
b
b
s
s
i
i
t
t
e
e
for
enhanced surge suppression.
Liebert PanelGuard Extension
minimizes data corruption, errors,
system re-boots and component
failure. Sine wave tracking circuitry
filters high frequency electrical line
noise. Patented component level
monitoring, including neutral to
ground, allows status detection in
real time.
Features & Benefits
Flexible mounting (top or bottom)
to virtually any panelboard.
Universal panelboard application
can be used with most major
manufacturers.
UL 1449 and UL 1283
Surge current capacity
levels from
130kA per phase to 200kA per phase.
S
t
andard features
inc
lu
de all modes
of protection, unit status indicators
and isolated form C dry contacts.
O
p
ti
o
ns include:
a
u
d
ib
le alarm,
transient counter.
Liebert
®
PanelGuard
Extension
Clean Power Distribution For Electronic Panelboards
Emerson Network Power.com
Emerson Network Power.
The global leader in enabling
Business-Critical Continuity
.
AC Power
Connectivity
DC Power
Embedded Computing
Embedded Power
Monitoring
Outside Plant
Power Switching & Controls
Precision Cooling
Racks & Integrated Cabinets
Services
Surge Protection
Liebert Corporation
1050
Dearborn Drive
P.O.
Box 29186
Col
umbus, Ohio 43229
800 877 9222
Phone (U.S. &
Canada Onl
y)
614 888 0246 Phone (Outside U.S.)
614 841 6022 FAX
Via Leonardo Da Vinci 8
Zona
Industriale Tognana
35028
Piove Di Sacco (PD)
Ital
y
39 049 971
9 111 Phone
39 049 584
1 257 FAX
Emerson Network Power Asia Pacific
7/F., Dah Sing Financial Centre
108 G
loucester Rd, Wanchai
Hong Kong
852 2572
2201 Phone
852 28029250 FAX
liebert.com
Technical Support
800 288 6169 Toll-Free
607 724 2484 Phone
607 722 8713 Fax
UL 1449 RATINGS
Line to Line to Line Neutral
System Voltage Neutral Ground to Line to Ground
120/208 or 120/240 400 V 400 V 800 V 400 V
208, 240, 277 or 277/480 800 V 800 V 1500 V 800 V
Specifications
Surge Current Capacity
Minimum Tested
Single Pulse Surge Current Capacity
Protection Mode Impulses Per Mode Model 100 Model 80 Model 65
Line
-to-Neutral > 3,500 > 100,000 A > 80,000 A > 65,000 A
Line
-to-Ground > 3,500 > 100,000 A > 80,000 A > 65,000 A
Neutral-to-Ground > 3,500 > 100,000 A > 80,000 A > 65,000 A
Line
-to-Line > 3,500 > 100,000 A > 80,000 A > 65,000 A
P
e
r Phase > 7,000 > 200,000 A > 160,000 A > 130,000 A
Enclosure
NEMA 1 rated.
Surface mount dimensions are 12” x 20” x 6”.
Flush mount unit is 12” x 21.5” x 6”.
W
e
i
ght is 15 lb
s
.
EMI/RFI Noise Rejection Values
Single Unit Frequency System Installation
34 dB
100 kHz 51 dB
51 dB 1 MHz 94 dB
54 dB 10 MHz 114 dB
48 dB 100 MHz 120 dB
H
o
w T
o O
r
der Liebert Liebert PanelGuard
Ex
t
e
nsi
o
n
Duty life cycle tested to survive 20kV, 10kA, IEEE C62.41 Category C3 surge current
with less than 5% degradation of clamping voltage.
All systems EMI-RFI noise or attenuation rejection values are in compliance with test
and evaluation procedures outlined in NEMA LS 1-1992, paragraphs 2.2.11 and 3.11.
P
h
as
e c
o
nfiguration Code
1 P
h, 3W+G
. 12
0
/
240 VAC 120S
3 P
h, 4W+G
. 12
0
/
208 VAC 120Y
3 P
h, 4W+G
. 27
7
/
480 VAC 277Y
Other phase configurations available.
Please consult factory.
kA p
e
r m
od
e/per phase Code
65 kA pe
r mode
, 130 kA pe
r ph
ase 65
80 kA pe
r mode
, 160 kA pe
r ph
ase 80
100 kA pe
r mode
, 200 kA pe
r ph
ase 100
T
rim t
yp
e
Code
Sur
f
ac
e mo
unt trim S
F
lu
sh mo
un
t trim F
M
o
nit
o
rin
g options Code
S
t
and
ar
d S
tatus LEDs only -00
LEDs
, A
u
d
ibl
e Alarm, Counter -01
LEDs
, A
u
d
ibl
e Alarm -02
LEDs
, C
o
un
t
er -03
H
o
w t
o c
onstruct a Liebert PanelGuard
Ex
t
e
nsi
on (LPGE) model # Code
1. Li
e
be
r
t PanelGuard Extension LPGE
2. P
h
a
s
e configuration 120S
3. kA pe
r mod
e
/
per phase 65
4. T
r
im t
y
pe: surface mount S
5. M
onit
or
ing op
tions -01
Sample model #: LPGE120S65S-01
Whi
l
e e
v
e
r
y precaution has been taken to ensure accuracy and
c
om
pl
e
t
e
ne
s
s in this lit
erature, Liebert Corporation assumes no
r
esponsibility, and disclaims all liability for damages resulting
f
r
om u
s
e o
f this information or for any errors or omissions.
© 2008 Liebert Corporation. All rights reserved throughout
the world. Specifications subject to change without notice.
All names referred to are trademarks or registered trademarks
o
f their respective owners.
® Liebert is a registered trademark of the Liebert Corporation.
SL
-22065 (R06/08) Pr
in
ted in USA
B
usiness-Critical Continuity
, Eme
rson Network
P
o
w
e
r an
d the Eme
rson Network Power logo are
trademarks and service marks of Emerson
Electric Co. ©2008 Emerson Electric Co.
800 288 6169 Toll-Free
607 721 8865 Phone
607 722 8713 Fax
  • Page 1 1
  • Page 2 2

Emerson 65 User manual

Category
Surge protectors
Type
User manual

Emerson 65, a reliable surge protector, offers comprehensive protection for your critical business systems. Its flexible mounting options and universal panelboard compatibility make it easy to integrate with existing electrical setups. With surge current capacities ranging from 65,000 amps to 130,000 amps per phase, it ensures superior protection against power surges and electrical noise. Advanced features like real-time status monitoring, isolated dry contacts, and optional audible alarms and transient counters provide enhanced visibility and control.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI