Cisco Systems 3010 User manual

Category
Network switches
Type
User manual

This manual is also suitable for

Americas Headquarters
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
USA
http://www.cisco.com
Tel: 408 526-4000
800 553-NETS (6387)
Fax: 408 527-0883
Cisco IE 3010 Switch Hardware Installation
Guide
Revised October 12, 2012
Text Part Number: 78-19581-02
THE SPECIFICATIONS AND INFORMATION REGARDING THE PRODUCTS IN THIS MANUAL ARE SUBJECT TO CHANGE WITHOUT NOTICE. ALL
STATEMENTS, INFORMATION, AND RECOMMENDATIONS IN THIS MANUAL ARE BELIEVED TO BE ACCURATE BUT ARE PRESENTED WITHOUT
WARRANTY OF ANY KIND, EXPRESS OR IMPLIED. USERS MUST TAKE FULL RESPONSIBILITY FOR THEIR APPLICATION OF ANY PRODUCTS.
THE SOFTWARE LICENSE AND LIMITED WARRANTY FOR THE ACCOMPANYING PRODUCT ARE SET FORTH IN THE INFORMATION PACKET THAT
SHIPPED WITH THE PRODUCT AND ARE INCORPORATED HEREIN BY THIS REFERENCE. IF YOU ARE UNABLE TO LOCATE THE SOFTWARE LICENSE
OR LIMITED WARRANTY, CONTACT YOUR CISCO REPRESENTATIVE FOR A COPY.
The following information is for FCC compliance of Class A devices: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant
to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio-frequency energy and, if not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case users will be required
to correct the interference at their own expense.
The following information is for FCC compliance of Class B devices: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant
to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If the equipment causes interference to radio or television reception, which can be
determined by turning the equipment off and on, users are encouraged to try to correct the interference by using one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Modifications to this product not authorized by Cisco could void the FCC approval and negate your authority to operate the product.
The Cisco implementation of TCP header compression is an adaptation of a program developed by the University of California, Berkeley (UCB) as part of UCB’s public
domain version of the UNIX operating system. All rights reserved. Copyright © 1981, Regents of the University of California.
NOTWITHSTANDING ANY OTHER WARRANTY HEREIN, ALL DOCUMENT FILES AND SOFTWARE OF THESE SUPPLIERS ARE PROVIDED “AS IS” WITH
ALL FAULTS. CISCO AND THE ABOVE-NAMED SUPPLIERS DISCLAIM ALL WARRANTIES, EXPRESSED OR
IMPLIED, INCLUDING, WITHOUT
LIMITATION, THOSE OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT OR ARISING FROM A COURSE OF
DEALING, USAGE, OR TRADE PRACTICE.
Cisco and the Cisco logo are trademarks or registered trademarks of Cisco and/or its affiliates in the U.S. and other countries. To view a list of Cisco trademarks, go to this
URL:
www.cisco.com/go/trademarks. Third-party trademarks mentioned are the property of their respective owners. The use of the word partner does not imply a partnership
relationship between Cisco and any other company. (1110R)
Any Internet Protocol (IP) addresses used in this document are not intended to be actual addresses. Any examples, command display output, and figures included in the
document are shown for illustrative purposes only. Any use of actual IP addresses in illustrative content is unintentional and coincidental.
Cisco IE 3010 Switch Hardware Installation Guide
© 2010-2012 Cisco Systems, Inc. All rights reserved.
iii
Cisco IE 3010 Switch Hardware Installation Guide
78-19581-02
CONTENTS
Preface vii
Related Publications i-viii
Obtaining Documentation and Submitting a Service Request i-viii
CHAPTER
1 Product Overview 1-1
Switch Models 1-1
Cable Side 1-2
10/100 Fast Ethernet Ports 1-3
PoE Ports 1-3
Dual-Purpose Ports 1-4
SFP Modules 1-5
SFP Module Patch Cable 1-6
Power-Input Terminal 1-6
Alarm Ports 1-6
Alarm Input 1-7
Alarm Output 1-7
Management Ports 1-7
LEDs 1-8
Switch Panel LEDs 1-8
System LED 1-9
Power-Supply Module LEDs 1-9
Alarm LEDs 1-9
Console LEDs 1-10
Port LEDs 1-10
PoE LED 1-11
Dual-Purpose Port LEDs 1-11
SD Flash Memory Card LED 1-11
SD Flash Memory Card 1-11
Power-Supply Side 1-12
Power-Supply Side LEDs 1-13
Power Supply Features 1-14
Management Options 1-14
Network Configurations 1-14
Contents
iv
Cisco IE 3010 Switch Hardware Installation Guide
78-19581-02
CHAPTER
2 Switch Installation 2-1
Warnings 2-1
Installation Guidelines 2-3
Verifying Switch Operation 2-3
Installing the Switch 2-4
Rack-Mounting 2-4
Attaching Brackets for 19-Inch Racks 2-5
Attaching Brackets for 19-Inch Racks for IP-30 Compliance (Optional) 2-6
Attaching Brackets for 23-Inch Racks 2-12
Attaching Brackets for ETSI Racks 2-13
Rack-Mounting the Switch 2-14
Wall-Mounting 2-15
Attaching Brackets 2-16
Attaching Brackets for IP-30 Compliance (Optional) 2-16
Wall-Mounting the Switch 2-18
Installing and Removing SFP Modules 2-20
Installing SFP Modules 2-20
Removing SFP Modules 2-21
Inserting and Removing the SFP Module Patch Cable 2-21
Removing the SFP Module Patch Cable 2-22
Replacing the SD Flash Memory Card 2-23
Connecting Devices to the Ethernet Ports 2-25
Connecting to the 10/100 and 10/100/1000 Ports 2-25
Connecting to the 10/100 PoE Ports 2-26
Where to Go Next 2-27
CHAPTER
3 Power Supply Installation 3-1
Power-Supply Modules 3-1
Power-Supply Module Installation 3-3
Installation Guidelines 3-3
Installing a Power-Supply Module 3-4
Equipment That You Need 3-4
Grounding the Switch 3-4
Installing the Power-Supply Module in the Switch 3-6
Wiring the Power Source 3-7
Removing the Power-Supply Module 3-12
Contents
v
Cisco IE 3010 Switch Hardware Installation Guide
78-19581-02
CHAPTER
4 Troubleshooting 4-1
Diagnosing Problems 4-1
Switch POST Results 4-1
Switch LEDs 4-2
Switch Connections 4-2
Bad or Damaged Cable 4-2
Ethernet and Fiber-Optic Cables 4-2
Link Status 4-2
10/100 and 10/100/1000 Port Connections 4-3
10/100 PoE Port Connections 4-3
SFP Module 4-3
Interface Settings 4-3
Ping End Device 4-3
Spanning Tree Loops 4-4
Switch Performance 4-4
Speed, Duplex, and Autonegotiation 4-4
Autonegotiation and Network Interface Cards 4-4
Cabling Distance 4-4
Resetting the Switch to the Factory Default Settings 4-5
Finding the Switch Serial Number 4-5
APPENDIX
A Technical Specifications A-1
Switch Specifications A-1
Power-Supply Module Specifications A-4
Alarm Ratings A-5
APPENDIX
B Connector and Cable Specifications B-1
Connector Specifications B-1
10/100 B-1
SFP Module Connectors B-2
Dual-Purpose Ports B-3
Alarm Port B-3
Cables and Adapters B-4
SFP Module Cables B-4
Cable Pinouts B-6
Console Port Adapter Pinouts B-7
Contents
vi
Cisco IE 3010 Switch Hardware Installation Guide
78-19581-02
APPENDIX
C Configuring the Switch with the CLI Setup Program C-1
Accessing the CLI Through the Console Port C-1
RJ-45 Console Port C-1
USB Console Port C-3
Installing the Cisco Microsoft Windows USB Device Drivers C-4
Installing the Cisco Microsoft Windows XP USB Driver C-4
Installing the Cisco Microsoft Windows 2000 USB Driver C-4
Installing the Cisco Microsoft Windows Vista USB Driver C-5
Uninstalling the Cisco Microsoft Windows USB Drivers C-5
Uninstalling the Cisco Microsoft Windows XP and 2000 USB Driver C-5
Uninstalling the Cisco Microsoft Windows Vista USB Driver C-6
Entering the Initial Configuration Information C-7
IP Settings C-7
Completing the Setup Program C-7
I
NDEX
vii
Cisco IE 3010 Switch Hardware Installation Guide
78-19581-02
Preface
This guide describes the hardware features of the Cisco Industrial Ethernet (IE) 3010 switch. It describes
the physical and performance characteristics of the switch, explains how to install it, and provides
troubleshooting information.
This guide does not describe system messages that you might receive or how to configure your switch.
See the switch software configuration guide, the switch command reference, and the switch system
message guide on Cisco.com:
http://www.cisco.com/go/IE3010_docs
Note Means reader take note. Notes contain helpful suggestions or references to materials not contained in
this manual.
Caution Means reader be careful. In this situation, you might do something that could result in equipment
damage or loss of data.
Warning
IMPORTANT SAFETY INSTRUCTIONS
This warning symbol means danger. You are in a situation that could cause bodily injury. Before you
work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar
with standard practices for preventing accidents. Use the statement number provided at the end of
each warning to locate its translation in the translated safety warnings that accompanied this
device.
Statement 1071
SAVE THESE INSTRUCTIONS
viii
Cisco IE 3010 Switch Hardware Installation Guide
78-19581-02
Preface
Related Publications
The safety warnings for this product are translated into several languages in the Regulatory Compliance
and Safety Information for the Cisco IE 3010 Switch that ships with the product on the documentation
CD. The EMC regulatory statements are also included in that guide.
Related Publications
http://www.cisco.com/go/IE3010_docs
Note Before installing, configuring, or upgrading the switch, see the release notes on Cisco.com for
the latest information.
Release Notes for the Cisco IE 3010 Switch
Cisco IE 3010 Switch Getting Started Guide
Regulatory Compliance and Safety Information for the Cisco IE 3010 Switch
Cisco IE 3010 Switch Software Configuration Guide
Cisco IE 3010 Switch Command Reference
Cisco IE 3010 Switch System Message Guide
Cisco SFP documents:
http://www.cisco.com/en/US/products/hw/modules/ps5455/prod_installation_guides_list.html
SFP compatibility matrix documents:
http://www.cisco.com/en/US/products/hw/modules/ps5455/products_device_support_tables_list.html
Obtaining Documentation and Submitting a Service Request
For information on obtaining documentation, submitting a service request, and gathering additional
information, see the monthly What’s New in Cisco Product Documentation, which also lists all new and
revised Cisco technical documentation, at:
http://www.cisco.com/en/US/docs/general/whatsnew/whatsnew.html
Subscribe to the What’s New in Cisco Product Documentation as a Really Simple Syndication (RSS) feed
and set content to be delivered directly to your desktop using a reader application. The RSS feeds are a free
service and Cisco currently supports RSS version 2.0.
CHAPTER
1-1
Cisco IE 3010 Switch Hardware Installation Guide
78-19581-02
1
Product Overview
The Cisco IE 3010 switch provides a rugged and secure switching infrastructure for harsh environments.
It is suitable for industrial Ethernet applications, including process manufacturing, intelligent
transportation systems (ITSs), rail transportation, and other similar deployments.
In industrial environments, you can connect the switch to any Ethernet-enabled industrial
communication devices, including programmable logic controllers (PLCs), human-machine interfaces
(HMIs), drives, sensors, and input and output (IO) devices.
Switch Models, page 1-1
Cable Side, page 1-2
Power-Supply Side, page 1-12
Management Options, page 1-14
Switch Models
Table 1-1 Switch Models
Model Description
Cisco IE-3010-24TC 24 10/100 FastEthernet ports, 2 dual-purpose ports
(2 10/100/1000BASE-T copper ports and 2 SFP
1
module slots), and
2 AC and DC power-supply module slots.
1. SFP = small form-factor pluggable.
Cisco IE-3010-16S-8PC 16 100BASE-FX SFP-module slots; 8 10/100 FastEthernet PoE
2
ports,
2 dual-purpose ports (2 10/100/1000BASE-T copper ports and 2 SFP
module slots), and 2 AC and DC power-supply module slots.
2. PoE = Power over Ethernet.
1-2
Cisco IE 3010 Switch Hardware Installation Guide
78-19581-02
Chapter 1 Product Overview
Cable Side
Cable Side
The 10/100 Fast Ethernet downlink ports in Figure 1-1 are grouped in pairs. The first member of the pair
(port 1) is above the second member (port 2) on the left. Port 3 is above port 4, and so on.
The
dual-purpose ports are numbered 1 and 2.
Figure 1-1 Cisco IE-3010-24TC Cable-Side View
1 SD
1
flash memory card slot
1. SD = Secure Digital
6 RJ-45 console port
2 LEDs 7 USB (mini-Type B) console port
3 Express Setup button 8 Power-input terminal
4 10/100 ports 9 Alarm port
5 Dual purpose ports
7
4 92
1 3 5 6 8
208362
Cisco IE 3010
1-3
Cisco IE 3010 Switch Hardware Installation Guide
78-19581-02
Chapter 1 Product Overview
Cable Side
The100BASE-FX SFP ports and the 10/100 PoE ports are grouped in pairs. The first member of the pair
(port
1) is above the second member (port 2) on the left. Port 3 is above port 4, and so on.
The
dual-purpose ports are numbered 1 and 2.
Figure 1-2 Cisco IE-3010-16S-8PC Cable-Side View
10/100 Fast Ethernet Ports
You can set the 10/100 ports on the switch to operate in any combination of half duplex, full duplex, or
10 or 100 Mb/s. You can set the ports for speed and duplex autonegotiation. The default setting is
autonegotiate.
When set for autonegotiation, the switch determines the speed and duplex settings of the attached device
and advertises its own capabilities. If the connected device also supports autonegotiation, the switch
negotiates the best connection (the fastest line speed that both devices support and full-duplex
transmission if the attached device supports it) and configures itself accordingly. In all cases, the
attached device must be within 328 feet (100
meters).
PoE Ports
Warning
Voltages that present a shock hazard may exist on Power over Ethernet (PoE) circuits if
interconnections are made using uninsulated exposed metal contacts, conductors, or terminals.
Avoid using such interconnection methods, unless the exposed metal parts are located within a
restricted access location and users and service people who are authorized within the restricted
access location are made aware of the hazard. A restricted access area can be accessed only through
the use of a special tool, lock and key or other means of security.
Statement 1072
1 SD flash memory card slot 6 Dual purpose ports
2 LEDs 7 RJ-45 console port
3 Express Setup button 8 USB (mini-Type B) console port
4 100BASE-FX SFP ports 9 Power-input terminal
5 10/100 PoE ports 10 Alarm port
PO W ER
OVER
ET HER N ET
PO W ER
OVER
ET HER N ET
8
4
102
1 3 65 7 9
208363
Cisco IE 3010
1-4
Cisco IE 3010 Switch Hardware Installation Guide
78-19581-02
Chapter 1 Product Overview
Cable Side
The 10/100 PoE ports on the Cisco IE-3010-16S-8PC switches provide PoE support for devices that are
compliant with IEEE 802.3af. The Cisco prestandard PoE is also supported for Cisco IP
Phones and
Cisco
Aironet Access Points. The PoE ports on the switch deliver up to 15.4 W of PoE. Any four of the
eight ports are designated as high priority PoE ports, while the other four ports are designated as low
priority PoE ports. When both the power-supply modules are installed, the system has enough power to
support all eight ports as PoE ports. In case one of the power-supply modules fails, the power to the low
priority PoE ports is dropped, while power to the high priority PoE ports remains uninterrupted.
On a per-port basis, you control whether or not a port automatically provides power when an IP phone
or an access point is connected.
The 10/100 PoE ports use RJ-45 connectors with Ethernet pinouts. The maximum cable length is 328
feet (100 meters). The 100BASE-TX and 1000BASE-T traffic requires Category
5, Category 5e, or
Category
6 unshielded twisted pair (UTP) cable. The 10BASE-T traffic can use Category 3 or
Category 4 UTP cable.
For information about configuring and monitoring PoE ports, see the switch software configuration
guide on Cisco.com.
For information about port connections and port specifications, see the “Connecting Devices to the
Ethernet Ports” section on page 2-25 and the “Connector and Cable Specifications” section on page B-1.
Note The output of the PoE circuit has been evaluated as a Limited Power Source (LPS) per IEC 60950-1.
Dual-Purpose Ports
You can configure the dual-purpose ports on the switch as either 10/100/1000 ports or as SFP-module
ports. You can set the 10/100/1000 ports to autonegotiate, or you can configure them as fixed 10, 100,
or 1000 Mb/s (Gigabit) Ethernet ports.
By default, the switch selects the medium for each dual-purpose port (10/100/1000BASE-T or SFP).
When a link is achieved on one media type, the switch disables the other media type until the active link
goes down. If links are active on both media, the SFP-module port has priority, but you can use the
media-type interface configuration command to manually designate the port as an RJ-45 port or an SFP
port.
You can configure the speed and duplex settings consistent with the selected media type. For information
on configuring interfaces, see the switch software configuration guide.
1-5
Cisco IE 3010 Switch Hardware Installation Guide
78-19581-02
Chapter 1 Product Overview
Cable Side
SFP Modules
The switch Ethernet SFP modules provide connections to other devices. These field-replaceable
transceiver modules provide the uplink interfaces.The modules have LC connectors for fiber-optic
connections or RJ-45 connectors for copper connections. You can use any combination of the supported
SFP modules listed in
Table 1-2.
For information about SFP modules, see your SFP module documentation and the “Installing and
Removing SFP Modules” section on page 2-20. For cable specifications, see Appendix B, “SFP Module
Cables.
Table 1-2 Maximum Operating Temperature
Type of SFP Module Model
Rugged and Industrial SFPs
–40 to 140°F (–40 to 60°C)
GLC-SX-MM-RGD
GLC-LX-SM-RGD
GLC-FE-100LX-RGD
GLC-FE-100FX-RGD
GLC-ZX-SM-RGD
Commercial SFPs
32 to 113°F (0 to 45°C)
GLC-BX-D with DOM support
GLC-BX-U with DOM support
GLC-FE-100LX
GLC-FE-100BX-D
GLC-FE-100BX-U
GLC-FE-100FX
GLC-FE-100EX
GLC-FE-100ZX
CWDM SFP with DOM support
Extended temperature SFPs
23 to 140°F (–5 to 60°C)
SFP-GE-L with digital optical monitoring
(DOM) support
SFP-GE-S with DOM support
SFP-GE-Z with DOM support
GLC-EX-SMD with DOM support
1-6
Cisco IE 3010 Switch Hardware Installation Guide
78-19581-02
Chapter 1 Product Overview
Cable Side
SFP Module Patch Cable
The switch uses an SFP-module patch cable, a 0.5-meter, copper, passive cable with SFP module
connectors at each end (see Figure 1-3). The patch cable connects two switches in a cascaded
configuration.
Figure 1-3 SFP-Module Patch Cable
See the “Inserting and Removing the SFP Module Patch Cable” section on page 2-21 for information
about using the SFP module patch cable.
You can order this cable (part number CAB-SFP-50CM=).
Power-Input Terminal
The power-input terminal provides screw terminals for the AC and DC power connections. The switch
can operate with one or two power supplies. If one of the power sources fail, the other continues to power
the switch. See
Chapter 3, “Power Supply Installation, for information.
Figure 1-4 Power-Input Terminal
Alarm Ports
The switch has four alarm inputs and one alarm output. The alarm setting is open or closed.
Open means that the normal condition has current flowing through the contact (referred to as a
normally closed contact). The alarm is generated when the current stops.
Closed means that no current flows through the contact (referred to as a normally open contact). The
alarm is generated when the current flows.
126809
208415
1-7
Cisco IE 3010 Switch Hardware Installation Guide
78-19581-02
Chapter 1 Product Overview
Cable Side
Alarm Input
The alarm input is a dry-contact alarm port. You can connect up to four alarm inputs from devices, such
as a door, a temperature gauge, or a fire alarm, to the alarm port. You can use the CLI to set the alarm
severity to minor, major, or critical. An alarm generates a system message and turns on an LED. See the
Alarm LEDs” section on page 1-9 for the LED descriptions.
Alarm Output
The alarm output can be configured as a minor or major alarm. Output alarms often control an external
alarm, such as a bell or a light. To connect an external alarm device to the relay, you connect two relay
contact wires to complete the electrical circuit. See
Figure B-4 on page B-3 for information on the alarm
pinouts.
Management Ports
You can connect the switch to a PC running Microsoft Windows or to a terminal server through either
the RJ-45 console port or the USB console port.
RJ-45 console port. The RJ-45 connection uses an RJ-45-to-DB-9 female cable.
USB mini-Type B console port (5-pin connector). The USB connection uses a USB Type A-to-5-pin
mini-Type B cable.
The USB console interface speeds are the same as the RJ-45 console interface speeds.
To use the USB console port, you must install the Cisco Windows USB device driver on the device that
is connected to the USB console port (device running with Microsoft Windows).
Note For information about downloading the Cisco USB device driver, see the “Installing the Cisco Microsoft
Windows USB Device Drivers” section on page C-4.
With the Cisco Windows USB device driver, connecting and disconnecting the USB cable from the
console port does not affect Windows HyperTerminal operations. Mac OS X or Linux require no special
drivers.
Note The 5-pin mini-Type B connectors resemble the 4-pin mini-Type B connectors. They are not compatible.
Use only the 5-pin mini-Type B. See Figure 1-5.
Figure 1-5 USB Mini-Type B Port
The configurable inactivity timeout reactivates the RJ-45 console port if the USB console port is
activated, but no input activity occurs on it for a specified time period. When the USB console port
deactivates due to a timeout, you can restore its operation by disconnecting and reconnecting the USB
cable. For information on using the CLI to configure the USB console interface, see the switch software
guide.
253163
1-8
Cisco IE 3010 Switch Hardware Installation Guide
78-19581-02
Chapter 1 Product Overview
Cable Side
LEDs
You can use the switch system and port LEDs to monitor switch activity and performance.
Switch Panel LEDs
Figure 1-6 Switch LEDs (Cable Side)
1 SYS (system) 9 OUT (alarm output)
2 CON (RJ-45 console) 10 PSU1 (power supply 1)
3 USB (mini-USB console) 11 PSU2 (power supply 2)
4 SD (SD flash memory card) 12 PoE
1
1. Only on the Cisco IE-3010-16S-8PC switch.
5 IN1 (alarm input 1) 13 Express Setup button
6 IN2 (alarm input 2) 14 Ethernet ports
7 IN3 (alarm input 3) 15 SFP module port
8 IN4 (alarm input 4) 16 10/100/1000 port
207198
21 3 45678 9 10 11 12 13
14 15
16
1-9
Cisco IE 3010 Switch Hardware Installation Guide
78-19581-02
Chapter 1 Product Overview
Cable Side
System LED
Power-Supply Module LEDs
The switch power-supply module LEDs are labeled PSU1 and PSU2 (on the switch) and PSU OK (on
the power-supply module). They show whether power-supply modules 1 and 2 are receiving power. See
Figure 1-6 and Figure 1-9.
Alarm LEDs
Table 1-3 System LED
Color System Status
Off System is not powered on.
Blinking green POST
1
is in progress.
1. POST = power-on self-test.
Green System is operating normally.
Amber System is receiving power but is not functioning properly.
Table 1-4 Power-Supply Module LEDs
Color System Status
Off Power-supply module (1 or 2) is not installed.
Green Valid input is present, and the output is within the operating range.
Red Valid input is present, and the output is outside the operating range or is not present.
Blinking red Valid input is not present.
Table 1-5 Alarm Input LEDs
Color System Status
Off No alarm
Amber Minor alarm
Red Major alarm
Blinking red Critical alarm
Table 1-6 Alarm Output LED
Color System Status
Green No alarm
Red Relay closed, alarm present
1-10
Cisco IE 3010 Switch Hardware Installation Guide
78-19581-02
Chapter 1 Product Overview
Cable Side
Console LEDs
The console LEDs show which console port is in use. See Figure 1-6 and Figure 1-9 for the LED
locations.
If you connect a cable to a console port, the switch automatically uses that port for console
communication. If you connect two console cables, the USB console port has priority.
Port LEDs
RJ-45 ports and SFP-module slots have port LEDs. Port LEDs, as a group or individually, provide
information about the switch and about the individual ports.
Table 1-7 RJ-45 and USB Console Port LEDs
LED Color Description
RJ-45 console port Green RJ-45 console port is active.
USB console port LED is off.
Off Port is not active.
USB console port is active.
USB console port Green USB console port is active.
RJ-45 console port LED is off.
Off Port is not active.
RJ-45 console port is active.
Table 1-8 Meaning of Port LED Colors
LED Color Meaning
Off No link or port was administratively shut down.
Green Link present but not sending or receiving data.
Blinking green Activity. Port is sending or receiving data.
Alternating
green-amber
Link fault. Error frames can affect connectivity, and errors such as excessive
collisions, CRC errors, and alignment and jabber errors are monitored for link
faults.
Amber Port is blocked by Spanning Tree Protocol (STP) and is not forwarding data.
After a port is reconfigured, the port LED is amber for up to 30 seconds as STP
searches for loops.
1-11
Cisco IE 3010 Switch Hardware Installation Guide
78-19581-02
Chapter 1 Product Overview
Cable Side
PoE LED
Dual-Purpose Port LEDs
The dual-purpose port LEDs identify the connection as either a copper-based connector or an SFP
module. The ports can autonegotiate, or you can manually configure each dual-purpose port as either
10/100/1000 with copper connectors or as an SFP-module port, but not as both types at the same time.
See Table 1-8 for LED descriptions.
SD Flash Memory Card LED
SD Flash Memory Card
The switch ships with the Secure Digital (SD) flash memory card installed. See Figure 1-1 and
Figure 1-2. The switch stores the Cisco IOS software images and the switch configuration on the card.
You should not remove the card unless you want to use it in a replacement switch. You then do not have
to reconfigure the new switch. See the
“Replacing the SD Flash Memory Card” section on page 2-23 for
information.
Table 1-9 PoE LED
Color Meaning
Off PoE is not enabled.
Green PoE is enabled. Ports are functioning correctly.
Amber PoE is enabled, but an error is present.
Table 1-10 SD Flash Memory Card LED
Color System Status
Off / blinking green SD flash memory card transfer in progress.
Blinking amber SD flash memory card is not present (slow blinking).
Unsupported SD flash memory card is detected (fast blinking).
Amber Error accessing the SD flash memory card.
Cisco IOS boot image cannot be found.
Green SD flash memory card is functioning.
1-12
Cisco IE 3010 Switch Hardware Installation Guide
78-19581-02
Chapter 1 Product Overview
Power-Supply Side
Power-Supply Side
The power-supply side has the LED panel and two power-supply slots for the removable power supplies.
See
Figure 1-7 and Figure 1-8.
Figure 1-7 Switch with One Power-Supply Module
Figure 1-8 Switch with Both Power-Supply Modules
For a description of the PSU OK LED, see Table 1-4 on page 1-9.
1 LED panel 3 Power-supply slot 2
2 Power-supply slot 1
2
1
3
208365
Cisco
Sw itch Series
IE 3010
PW R-RGD-LOW -D C
1 PSU OK LED
208375
Cisco IE 3010
Sw itch Series
1
1
PW R-RGD-LOW -D C
PW R-RGD-LOW-DC
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100

Cisco Systems 3010 User manual

Category
Network switches
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI