Quatech DS-100 User manual

Category
Label printers
Type
User manual

This manual is also suitable for

DS-100
Two Channel RS-232 Asynchronous
Serial Adapter
for ISA compatible machines
User's Manual
QUATECH, INC. TEL: (330) 655-9000
5675 Hudson Industrial Parkway FAX: (330) 655-9010
Hudson, Ohio 44236 http://www.quatech.com
INTERFACE CARDS FOR IBM PC/AT AND PS/2
Warranty Information
Quatech Inc. warrants the DS-100 to be free of defects for
one (
5) years from the date of purchase. Quatech Inc. will repair or replace any adapter that fails to perform under normal
operating conditions and in accordance with the procedures outlined in this document during the warranty period. Any damage
that results from improper installation, operation, or general misuse voids all warranty rights.
The authors have taken due care in the preparation of this document and any associated software program(s). In no
event will Quatech Inc. be liable for damages of any kind, incidental or consequential, in regard to or arising out of the
performance or form of the materials presented herein and in the program(s) accompanying this document. No representation is
made regarding the suitability of this product for any particular purpose.
Quatech Inc. reserves the right to edit or append to this document or the product(s) to which it refers at any time and
without notice.
Please complete the following information and retain for your records. Have this information available when requesting warranty
service.
Date of purchase:
Model Number: DS-100
Product Description: Two Channel RS-232 Asynchronous Serial Adapter
Serial Number:
i Quatech Inc.
© 2001, Quatech, Inc.
NOTICE
The information contained in this document cannot be reproduced in any form without
the written consent of Quatech, Inc. Likewise, any software programs that might accompany this
document can be used only in accordance with any license agreement(s) between the purchaser
and Quatech, Inc. Quatech, Inc. reserves the right to change this documentation or the product to
which it refers at any time and without notice.
The authors have taken due care in the preparation of this document and every attempt
has been made to ensure its accuracy and completeness. In no event will Quatech, Inc. be liable
for damages of any kind, incidental or consequential, in regard to or arising out of the
performance or form of the materials presented in this document or any software programs that
might accompany this document.
Quatech, Inc. encourages feedback about this document. Please send any written
comments to the Technical Support department at the address listed on the cover page of this
document.
IBM PC
TM
, PC-AT
TM
, PS/2™, and Micro Channel™ are trademarks of International Business Machines
Corporation.
ii Quatech Inc.
Declaration of Conformity
Manufacturer's Name: Quatech Inc.
Manufacturer's Address: 5675 Hudson Industrial Parkway
Hudson, Ohio 44236 (USA)
Application of Council Directive: 89/336/EEC
Standards to which
Conformity is Declared: * EN50082-1
EN61000-4-2, EN61000-4-3, EN61000-4-4 * CISPR 22 (EN55022)
Type of Equipment: Information Technology Equipment
Equipment Class: Commercial, Residential, & Light
Industrial
Product Name: ISA Communications Card
Model Number : DS-100
iii Quatech Inc.
Table of Contents
8-1
9. Troubleshooting
....................................................
6-4
8. Specifications
.......................................................
6-1
7. External Connections
...............................................
5-26.1 Interrupt Sharing ....................................................
5-1
6. Interrupt Level (IRQ)
...............................................
4-35.2 Enabling or disabling ports ............................................
4-15.1 Setting the address ...................................................
4-1
5. Addressing Ports
....................................................
3-184.2 Viewing and Changing Resources with Device Manager .....................
3-164.1 Using the Add New Hardware Wizard ...................................
3-16
4. Windows 95 Configuration
..........................................
3-13.1 Using the Add New Hardware Wizard ....................................
3-1
3. Windows 2000 Configuration
........................................
2-1
2. Installation
.........................................................
1-1
1. General Information
................................................
iv Quatech Inc.
1. General Information
The Quatech, Inc. DS-100 provides two RS-232 asynchronous serial communication interfaces
for IBM-compatible personal computer systems using the 16-bit ISA (Industry Standard
Architecture) expansion bus.
The DS-100's serial ports are implemented using 16550 Universal Asynchronous
Receiver/Transmitters (UARTs). The 16550 UARTs enable the DS-100 to transmit and receive
data at a rate of up to 115.2 kbaud. The 16550 contains a 16-byte hardware buffer that reduces
processing overhead. To use the 16550’s buffering capabilities, the software must be aware of
the UART's presence. Otherwise, it will act as a 16450 UART.
The DS-100 is highly flexible with respect to addressing and interrupt level use. The serial ports
are individually addressed and can be placed anywhere within the range of 0000 hex to FFF8 hex
at 0008 hex intervals. Available interrupt levels include IRQ2 to IRQ7, IRQ10 to IRQ12,
IRQ14, or IRQ15.
Both ports on the DS-100 can share one interrupt level or an interrupt level can be shared with
another Quatech adapter that supports interrupt sharing. The shared interrupt feature minimizes
the system resources consumed by the adapter.
In order to support the use of the shared interrupt feature of the DS-100, Quatech has developed
device drivers for several popular operating systems and environments. The sales department
can be contacted for details on current offerings.
1-1 Quatech Inc.
(This Page Intentionally Left Blank)
1-2 Quatech Inc.
2. Installation
If the default address and interrupt settings are sufficient, the DS-100 can be quickly installed and
put to use. The factory defaults are listed in Figure 1.
YES32F8 hexSerial 1
YES43F8 hexSerial 0
ENABLEDIRQADDRESSPORT
Figure 1 --- Default address and IRQ settings for DS-100
The output of the DS-100 is two 9-pin D-connectors labeled CN1 (serial 0) and CN2 (serial 1).
1. If the default settings are correct, skip to step 2, otherwise refer to sections 4 and 5 of this
document for detailed information on how to set the address and IRQ level.
2. Turn off the power of the computer system in which the DS-100 is to be installed.
3. Remove the system cover according to the instructions provided by the computer
manufacturer.
4. Install the DS-100 in any vacant expansion slot. The board should be secured by
installing the Option Retaining Bracket (ORB) screw.
5. Replace the system cover according to the instructions provided by the computer
manufacturer.
6. Attach and secure the cable connectors to the desired equipment.
2-1 Quatech Inc.
IRQ2
IRQ3
IRQ4
IRQ5
IRQ6
IRQ7
IRQ10
IRQ11
IRQ12
IRQ14
IRQ15
(Diagram not to scale)
SW2
Serial 0
SW1
Serial 0
SW3
Serial 1
SW4
Serial 1
J3
J4
Serial 0
Serial 1
J2
J5
J6
Serial 0
Serial 1
CN1
CN2
16750
UART
16750
UART
RN1
RN2
RN3
RN4
14.7456
OSC
QUATECH INC
DS-100 REV I
Figure 2 --- Diagram of DS-100
2-2 Quatech Inc.
3. Windows 2000 Configuration
Windows 2000 maintains a registry of all known hardware installed in the computer. Inside the
hardware registry Windows 2000 keeps track of all of the system resources, such as I/O
locations, IRQ levels, and DMA channels. The “Add New Hardware Wizard” utility in
Windows is designed to add new hardware and update this registry.
Windows 2000 will not
automatically configure the DS-100. The user is required to manually
configure Windows 2000 to match the resources set on the card.
3.1 Using the Add New Hardware Wizard
The following instructions provide a step-by-step instructions on installing the DS-100 Enhanced
Serial Adapter in Windows 2000 using the “Add New Hardware” wizard.
1. Select Start>Settings>Controll Panel.
3-1 Quatech Inc.
2. Double click on the “Add New Hardware” icon.
3-2 Quatech Inc.
3. The next window will be the “Welcome to the Hardware Wizard”, click “Next”.
4. Next choose the “Add/Troublshoot a device” radio button, click “Next”.
3-3 Quatech Inc.
3-4 Quatech Inc.
3-5 Quatech Inc.
3-6 Quatech Inc.
7. Next select “Ports (COM & LPT)”, click “Next”.
3-7 Quatech Inc.
8. In the next window under manufacture select “(Standard port types), and under Models select
“Communications Port.
Because Windows will not detect plug and play you will have to manually enter the settings.
Click “OK”.
3-8 Quatech Inc.
9. Next you will have to change the “Input/Output Range” to a setting that is not in use “No
conflicts” by choosing a different “Basic Configuration”.
.
3-9 Quatech Inc.
10. The “Input Request” (IRQ) must be set to corresponds with the jumpers setting on the
DS-100 board.
3-10 Quatech Inc.
Once you have chosen the IRQ that corresponds with the setting on the Quatech DS-100 card the
window will display “no conflicts” and the red circle with a slash of the “Input/Output Range”
will not be present.
3-11 Quatech Inc.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42

Quatech DS-100 User manual

Category
Label printers
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI