Delta Electronics PG-02, Pulse Generator Card PG-02 User manual

  • Hello! I am an AI chatbot trained to assist you with the Delta Electronics PG-02 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
2007-07-12
5011606104-PGE
4
PG-02
Pulse Generator Card for VFD-B Series
Installation Instruction
Installation
1 to 2HP (0.75kW to 1.5kW)
P
G-
0
2
C
o
n
t
r
o
l
b
o
a
r
d
P
l
a
s
t
ic
S
t
a
n
d
o
f
f
P
G
C
a
r
d
T
e
r
m
i
n
a
l
I
n
s
u
l
a
t
i
on
s
p
a
c
e
r
P
G
-
0
2
C
o
n
t
r
o
l
b
o
a
r
d
P
G
C
a
r
d
T
e
r
m
i
n
a
l
I
n
s
u
l
a
t
i
o
n
s
p
a
c
e
r
7.5HP (5.5kW) and above
P
G
-
0
2
P
l
a
s
t
i
c
S
t
a
n
d
o
f
f
P
G
C
a
r
d
T
e
r
m
i
n
a
l
I
n
s
u
l
a
t
i
o
n
s
p
a
c
e
r
OC
5V
TP
12V
A
/O
B/O
COM
VP
DCM
A
B
PG-02
FSW2 FSW1
Connect to VFD-B
series control board
Wiring Terminals
Select the power
source and output
of Pulse Generator
A
B
3 to 5HP (2.2kW to 3.7kW)
Control Terminals Block Designations
2
PG Card and Pulse Generator
A. Basic Wiring Diagram
R/L1
S/L2
T/L3
NFB
U/T1
V/T2
W/T3
IM
3~
Motor
PG
A
B
VP
DCM
PG-02
+12V
GND
A
B
OC
5V
TP
12V
Factory
Default
PG-02 and Pulse Generator Connections
Pulse Generator
Output 12V DC
A
B
A
B
R/L 1
S/L2
T/L3
E
R/L1
S/L2
T/L3
NFB
U/T1
V/T2
W/T3
IM
3~
VP
COM
VFD-B
+5V
GND
OC
5VTP
12V
PG-02 and Pulse Generator Connections
A/O
B/O
RPM meter
DCM
PG
A
B
A
B
A
B
A
B
R/L1
S/L2
T/L3
E
E
None Fused Breaker
Motor
C. When Pulse Generators is Open Collector type, please wire as following.
R/L 1
S/L 2
T/L3
NFB
U/T 1
V/T2
W/T3
IM
3~
Motor
PG
A
B
VP
DCM
PG-02
+12V
GND
A
OC
5V
TP
12V
Factory
Default
PG-02 and Pulse Generator Connections
Pulse Generator
Output 12V DC
A
B
R/L 1
S/L 2
T/L3
E
B
B. Basic Wiring Diagram with RPM
Meter Attached.
3
PG-02 Terminal Descriptions
Terminals
Terminal Symbols Descriptions
VP
Power source of PG-02 (FSW1 can be switched to 12V or 5V)
Output Voltage: (+12VDC ±5% 200mA) or (+5VDC ±2% 400mA)
DCM Power source (VP) and input signal (A, B) common
Input signal from Pulse Generator. Input type is selected by FSW2.
Maximum 500KP/Sec
A/O, B/O
PG-02 output signal for use with RPM Meter.
Maximum DC24V 300mA
COM PG-02 output signal (A/O, B/O) common.
Wiring Notes
The control, power supply and motor leads must be laid separately. They
must not be fed through the same cable conduit / trunking.
1. Please use a shield cable to prevent interference. Do not run control wire parallel to any
high voltage AC power line (220 V and up).
2. Connect shielded wire to E only.
3. Recommended wire size 0.21 to 0.81mm
2
(AWG24 to AWG18).
4. Wire length:
Types of Pulse
Generators
Maximum Wire Length Wire Gauge
Output Voltage 50m
Open Collector 50m
Line Driver 300m
Complementary 70m
1.25mm
2
(AWG16) or above
4
Types of Pulse Generators
FSW1 and FSW2 switches
Types of Pulse Generators
5V
12V
Output Voltage
O/P
0V
VCC
OC
5
V
TP
12V
FSW2 FSW1
FSW2 FSW1
OC
5V
TP
12V
Open collector
O/P
0V
VCC
FSW2 FSW1
OC
V
TP
12V
FSW2 FSW1
OC
5V
TP
12V
Line driver
Q
Q
FSW2 FSW1
OC
5
V
TP
12V
FSW2 FSW1
OC
5V
TP
12V
Complimentary
O/P
0V
VCC
FSW2 FSW1
OC
5
V
TP
12V
FSW2 FSW1
OC
5V
TP
12V
ASIA
DELTA ELECTRONICS, INC.
TAOYUAN Plant/
31-1, SHIEN PAN ROAD,
KUEI SAN INDUSTRIAL ZONE
TAOYUAN 333
TEL: 886-3-362-6301
FAX: 886-3-362-7267
NORTH/SOUTH AMERICA
DELTA PRODUCTS
CORPORATION
Sales Office/
P.O. BOX 12173
5101 DAVIS DRIVE
RTP, NC 27709 U. S. A.
TEL: 1-919-767-3813
FAX: 1-919-767-3969
EUROPE
DELTRONICS (Netherlands) B.V.
Sales Office/
Industriegebied Venlo Nr. 9031
Columbusweg 20
NL-5928 LC Venlo
The Netherlands
TEL: 31-77-324-1930
FAX: 31-77-324-1931
/