Delta Electronics PG-02 User manual

Category
Power generators
Type
User manual

This manual is also suitable for

2007-07-12
5011606104-PGE
4
PG-02
Pulse Generator Card for VFD-B Series
Installation Instruction
Installation
1 to 2HP (0.75kW to 1.5kW)
P
G-
0
2
C
o
n
t
r
o
l
b
o
a
r
d
P
l
a
s
t
ic
S
t
a
n
d
o
f
f
P
G
C
a
r
d
T
e
r
m
i
n
a
l
I
n
s
u
l
a
t
i
on
s
p
a
c
e
r
P
G
-
0
2
C
o
n
t
r
o
l
b
o
a
r
d
P
G
C
a
r
d
T
e
r
m
i
n
a
l
I
n
s
u
l
a
t
i
o
n
s
p
a
c
e
r
7.5HP (5.5kW) and above
P
G
-
0
2
P
l
a
s
t
i
c
S
t
a
n
d
o
f
f
P
G
C
a
r
d
T
e
r
m
i
n
a
l
I
n
s
u
l
a
t
i
o
n
s
p
a
c
e
r
OC
5V
TP
12V
A
/O
B/O
COM
VP
DCM
A
B
PG-02
FSW2 FSW1
Connect to VFD-B
series control board
Wiring Terminals
Select the power
source and output
of Pulse Generator
A
B
3 to 5HP (2.2kW to 3.7kW)
Control Terminals Block Designations
2
PG Card and Pulse Generator
A. Basic Wiring Diagram
R/L1
S/L2
T/L3
NFB
U/T1
V/T2
W/T3
IM
3~
Motor
PG
A
B
VP
DCM
PG-02
+12V
GND
A
B
OC
5V
TP
12V
Factory
Default
PG-02 and Pulse Generator Connections
Pulse Generator
Output 12V DC
A
B
A
B
R/L 1
S/L2
T/L3
E
R/L1
S/L2
T/L3
NFB
U/T1
V/T2
W/T3
IM
3~
VP
COM
VFD-B
+5V
GND
OC
5VTP
12V
PG-02 and Pulse Generator Connections
A/O
B/O
RPM meter
DCM
PG
A
B
A
B
A
B
A
B
R/L1
S/L2
T/L3
E
E
None Fused Breaker
Motor
C. When Pulse Generators is Open Collector type, please wire as following.
R/L 1
S/L 2
T/L3
NFB
U/T 1
V/T2
W/T3
IM
3~
Motor
PG
A
B
VP
DCM
PG-02
+12V
GND
A
OC
5V
TP
12V
Factory
Default
PG-02 and Pulse Generator Connections
Pulse Generator
Output 12V DC
A
B
R/L 1
S/L 2
T/L3
E
B
B. Basic Wiring Diagram with RPM
Meter Attached.
3
PG-02 Terminal Descriptions
Terminals
Terminal Symbols Descriptions
VP
Power source of PG-02 (FSW1 can be switched to 12V or 5V)
Output Voltage: (+12VDC ±5% 200mA) or (+5VDC ±2% 400mA)
DCM Power source (VP) and input signal (A, B) common
Input signal from Pulse Generator. Input type is selected by FSW2.
Maximum 500KP/Sec
A/O, B/O
PG-02 output signal for use with RPM Meter.
Maximum DC24V 300mA
COM PG-02 output signal (A/O, B/O) common.
Wiring Notes
The control, power supply and motor leads must be laid separately. They
must not be fed through the same cable conduit / trunking.
1. Please use a shield cable to prevent interference. Do not run control wire parallel to any
high voltage AC power line (220 V and up).
2. Connect shielded wire to E only.
3. Recommended wire size 0.21 to 0.81mm
2
(AWG24 to AWG18).
4. Wire length:
Types of Pulse
Generators
Maximum Wire Length Wire Gauge
Output Voltage 50m
Open Collector 50m
Line Driver 300m
Complementary 70m
1.25mm
2
(AWG16) or above
4
Types of Pulse Generators
FSW1 and FSW2 switches
Types of Pulse Generators
5V
12V
Output Voltage
O/P
0V
VCC
OC
5
V
TP
12V
FSW2 FSW1
FSW2 FSW1
OC
5V
TP
12V
Open collector
O/P
0V
VCC
FSW2 FSW1
OC
V
TP
12V
FSW2 FSW1
OC
5V
TP
12V
Line driver
Q
Q
FSW2 FSW1
OC
5
V
TP
12V
FSW2 FSW1
OC
5V
TP
12V
Complimentary
O/P
0V
VCC
FSW2 FSW1
OC
5
V
TP
12V
FSW2 FSW1
OC
5V
TP
12V
ASIA
DELTA ELECTRONICS, INC.
TAOYUAN Plant/
31-1, SHIEN PAN ROAD,
KUEI SAN INDUSTRIAL ZONE
TAOYUAN 333
TEL: 886-3-362-6301
FAX: 886-3-362-7267
NORTH/SOUTH AMERICA
DELTA PRODUCTS
CORPORATION
Sales Office/
P.O. BOX 12173
5101 DAVIS DRIVE
RTP, NC 27709 U. S. A.
TEL: 1-919-767-3813
FAX: 1-919-767-3969
EUROPE
DELTRONICS (Netherlands) B.V.
Sales Office/
Industriegebied Venlo Nr. 9031
Columbusweg 20
NL-5928 LC Venlo
The Netherlands
TEL: 31-77-324-1930
FAX: 31-77-324-1931
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Delta Electronics PG-02 User manual

Category
Power generators
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI