Tecnoware FBBEVODS240/07 User manual

Type
User manual
Battery Box
FBBEVODS240/XX Type
User’s Manual
Index
1
Safety Warnings ............................................................................ 1
1.1 Product Disposal ......................................................................... 1
1.2 Lead Batteries ............................................................................ 1
2
Mechanical Drawings ...................................................................... 2
3
FBBEVODS240/07-11 ...................................................................... 3
4
FBBEVODS240/14-22 ...................................................................... 5
7
FBBEVODS240/21-33 ...................................................................... 7
6
Connections with the UPS ................................................................ 9
© Copyright 2010 TECNOWARE s.r.l. All rights reserved.
All trademarks are property of their respective owners.
TECNOWARE s.r.l.
Via Montetrini, 2E – Molino del Piano – Florence – Italy
www.tecnoware.com
This manual has been printed and edited by TECNOWARE s.r.l.
April 2010 edition – version 1.0
Battery Box Type FBBEVODS240/XX 1 User’s Manual
1 Safety Warnings
Risk of electric shock: if all the batteries are connected, inside the Battery Box there are
internal parts which are at a high Voltage and are potentially dangerous, capable of
causing injury or death by electric shock.
Any repair or maintenance work must be performed exclusively by qualified technical
personnel authorized by TECNOWARE. TECNOWARE declines any responsibility if this
warning is disregarded.
Battery fuses shall only be replaced with fuses of same rating or equivalent.
Danger of explosion and fire if the batteries of the wrong type or number are used.
Do not dispose of batteries in a fire. The batteries may explode. Do not open or mutilate
batteries. Released electrolyte is harmful to the skin and eyes. It may be toxic
The Battey Box is compliant with the European Community directives. Hence it is marked:
1.1 Product Disposal
This Battery Box cannot be disposed as an urban waste, but must be treated as a separate waste. Any
violation is indictable with financial sanctions as per in force regulations.
An incorrect waste disposal or an improper use of the same or of any parts can be damaging for the
environment and for human health.
A correct waste disposal of products having the dustbin symbol marked by a cross help to avoid
negative consequences to the environment and to human health.
1.2 Lead Batteries
The Battery Box may contain lead acid, sealed, maintenance free batteries.
This kind of batteries, if handled by non-experienced personnel, can cause electric shock or short-
circuit.
For this reason the batteries can be removed only by qualified technical personnel, specialized and
authorized by Tecnoware. Tecnoware declines any responsibilities if this rule is not followed.
The batteries cannot be disposed as an urban waste, but must be treated in conformity with
2006/66/CE European Directive; any violation is indictable with financial sanctions as established into
2006/66/CE European Directive.
User’s Manual 2 Battery Box Type FBBEVODS240/XX
2 Mechanical Drawings
Dimension (W x H x D) (25 x 50 x 79.5) cm
Net Weight without Batteries 45 Kg
Batteries Number 20 40 60
Net Weight with Batteries 7Ah 85 Kg 125 Kg 165 Kg
Net Weight with Batteries 11Ah 95 Kg 145 Kg 195 Kg
25 cm
50 cm
79
.5
cm
7 cm
Battery Box Type FBBEVODS240/XX 3 User’s Manual
3 FBBEVODS240/07-11
BOX BATTERY MODELS
Box Battery Code Description UPS Power
Battery
Capacity
Cables Section
Breaker Max
Current
FBBEVODS240/07
Battery Box Compatible with UPS
EVO DSP MM/MM
6 KVA 7Ah 6 mm
2
50 A
FBBEVODS240/11 10 KVA 11Ah 6 mm
2
50 A
BATTERIES
Battery Type Lead acid, sealed, free maintenance, 12 Vdc
Battery Number 1 x 20
Nominal Battery Voltage 240 Vdc
ENVIRONMENTAL CONDITIONS
Storage Temperature Range -25°C to +55°C (15°C to 40°C recommended for longer Battery life)
Operating Temperature Range 0°C to +40°C (20°C to 25°C recommended for longer Battery life)
Relative Humidity Range 0% - 95% (non condensing)
Max. Altitude without Derating 1000 meters
User’s Manual 4 Battery Box Type FBBEVODS240/XX
+
REAR SIDE
FRONT SIDE
THIRD
BATTERY
SHELF
UP
RED
(+ BATTERY)
TOP VIEW OF SHELVES
-
+
-
60 54
10
62
9 40 39 38 37 36 35 34 33 32
11 12 52 53
55 56 57 58 59
10A 9A 8A 7A 6A 5A 4A 3A 1A
11A 12A 13A 14A 15A 16A 17A 18A 19A 20A
BLACK
(
-
BATTERY)
SELECTOR
FIRST
BATTERY
SHELF
SECOND
BATTERY
SHELF
50cm
30cm
15cm
40cm
50cm
10cm
10C 9C 20B 19B 18B 17B 16B 15B 14B 13B 12B
11C
12C 12A 13A 14A 15A 16A 17A 18A 19A 20A
CHARGER
ON ON
OFF OFF
A = FIRST BLOCK
2A
50cm
+
-
NH
FUSE
7A
BATTERY
CHARGER INPUT
L
N
G
Battery Box Type FBBEVODS240/XX 5 User’s Manual
4 FBBEVODS240/14-22
BOX BATTERY MODELS
Box Battery Code Description UPS Power
Battery
Capacity
Cables Section
Breaker Max
Current
FBBEVODS240/14
Battery Box Compatible with UPS
EVO DSP MM/MM
6 KVA 7Ah 6 mm
2
50 A
FBBEVODS240/22 10 KVA 11Ah 6 mm
2
50 A
5
BATTERIES
Battery Type Lead acid, sealed, free maintenance, 12 Vdc
Battery Number 2 x 20
Nominal Battery Voltage 240 Vdc
6
ENVIRONMENTAL CONDITIONS
Storage Temperature Range -25°C to +55°C (15°C to 40°C recommended for longer Battery life)
Operating Temperature Range 0°C to +40°C (20°C to 25°C recommended for longer Battery life)
Relative Humidity Range 0% - 95% (non condensing)
Max. Altitude without Derating 1000 meters
User’s Manual 6 Battery Box Type FBBEVODS240/XX
+
REAR SIDE
FRONT SIDE
THIRD
BATTERY
SHELF
UP
RED
(+ BATTERY)
TOP VIEW OF SHELVES
-
+
-
10A 9A 8A 7A 6A 5A 4A 3A 1A
11A 12A 13A 14A 15A 16A 17A 18A 19A 20A
BLACK
(
-
BATTERY)
SELECTOR
FIRST
BATTERY
SHELF
SECOND
BATTERY
SHELF
50cm
30cm
15cm
40cm
50cm
10cm
CHARGER
ON ON
OFF OFF
A = FIRST BLOCK
B = SECOND BLOCK
2A
2B 10B
11B
9B
12B 13B 14B
8B 7B 6B
15B 16B
5B 4B
17B 18B 19B
3B 1B
20B
50cm
80cm
40cm
+
-
NH
FUSE
7A
BATTERY
CHARGER INPUT
L
N
G
Battery Box Type FBBEVODS240/XX 7 User’s Manual
7 FBBEVODS240/21-33
BOX BATTERY MODELS
Box Battery Code Description UPS Power
Battery
Capacity
Cables Section
Breaker Max
Current
FBBEVODS240/21
Battery Box Compatible with UPS
EVO DSP MM/MM
6 KVA 7Ah 6 mm
2
50 A
FBBEVODS240/33 10 KVA 11Ah 6 mm
2
50 A
8
BATTERIES
Battery Type Lead acid, sealed, free maintenance, 12 Vdc
Battery Number 3 x 20
Nominal Battery Voltage 240 Vdc
9
ENVIRONMENTAL CONDITIONS
Storage Temperature Range -25°C to +55°C (15°C to 40°C recommended for longer Battery life)
Operating Temperature Range 0°C to +40°C (20°C to 25°C recommended for longer Battery life)
Relative Humidity Range 0% - 95% (non condensing)
Max. Altitude without Derating 1000 meters
User’s Manual 8 Battery Box Type FBBEVODS240/XX
+
-
-
+
REAR SIDE
FRONT SIDE
THIRD
BATTERY
SHELF
UP
RED
(+ BATTERY)
TOP VIEW OF SHELVES
60 54
13C 14C 15C 16C 17C 18C 19C
CHARGER
1C 2C 3C 4C
5C
6C 7C 8C
10
62
9 40 39 38 37 36 35 34 33 32
11 12 52 53
55 56 57 58 59
31 30 29 28 27 26 25 24 23 22 21
41 42 43 44 45 46 47 48 49 50 51
BLACK
(
-
BATTERY)
SELECTOR
FIRST
BATTERY
SHELF
SECOND
BATTERY
SHELF
25cm
50cm
30cm
15cm
40cm
50cm
100cm
25cm
50cm
30cm
80cm
80cm
10cm
40cm
80cm
80cm
20C
ON ON
OFF OFF
11B 10B 9B 8B 7B 6B 5B 4B 3B 2B 1B
1A 2A 3A 4A 5A 6A 7A 8A 9A 10A 11A
A = FIRST BLOCK
B= SECOND BLOCK
C = THIRD BLOCK
11C
12C 12A 13A 14A 15A 16A 17A 18A 19A 20A
12B 13B 14B 15B 16B 17B 18B 19B 20B 9C 10C
+
-
NH
FUSE
7A
BATTERY
CHARGER INPUT
L
N
G
Battery Box Type FBBEVODS240/XX 9 User’s Manual
6 Connections with the UPS
+
-
+
BATTERY
-
BATTERY
+
BATTERY
-
BATTER
Y
BATTERY BOX
BATTERY
CONNECTOR
UPS
-
BATTER
Y
+
BATTER
Y
OTHER
BATTERY BOX
TECNOWARE s.r.l.
www.tecnoware.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14

Tecnoware FBBEVODS240/07 User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI